Merge "PowerMax Docs - Xena release notes"
This commit is contained in:
commit
18f7bd3800
@ -13,28 +13,36 @@ PowerMax storage management software. They use the Requests HTTP library to
|
||||
communicate with a Unisphere for PowerMax instance, using a RESTAPI interface
|
||||
in the backend to perform PowerMax and VMAX storage operations.
|
||||
|
||||
.. _VMAX-Hybrid:
|
||||
|
||||
.. note::
|
||||
|
||||
DEPRECATION NOTICE: The VMAX Hybrid series will not be supported from the
|
||||
``Z`` release of OpenStack. Also, any All Flash array
|
||||
running HyperMaxOS 5977 will no longer be supported from the ``Z``
|
||||
release onwards.
|
||||
|
||||
|
||||
.. note::
|
||||
|
||||
While ``PowerMax`` will be used throughout this document, it will be used
|
||||
to collectively categorize the following supported arrays, PowerMax 2000,
|
||||
8000, VMAX All Flash 250F, 450F, 850F and 950F and VMAX Hybrid. Please note
|
||||
there will be extended support of the VMAX Hybrid series until further
|
||||
notice.
|
||||
8000, VMAX All Flash 250F, 450F, 850F and 950F and VMAX-Hybrid_.
|
||||
|
||||
|
||||
System requirements and licensing
|
||||
=================================
|
||||
|
||||
The Dell EMC PowerMax Cinder driver supports the VMAX-3 hybrid series, VMAX
|
||||
All-Flash series and the PowerMax arrays.
|
||||
The Dell EMC PowerMax Cinder driver supports the VMAX-Hybrid_ series,
|
||||
VMAX All-Flash series and the PowerMax arrays.
|
||||
|
||||
The array operating system software, Solutions Enabler 9.2.1 series, and
|
||||
Unisphere for PowerMax 9.2.1 series are required to run Dell EMC PowerMax
|
||||
The array operating system software, Solutions Enabler 9.2.2 series, and
|
||||
Unisphere for PowerMax 9.2.2 series are required to run Dell EMC PowerMax
|
||||
Cinder driver for the Wallaby release. Please refer to support-matrix-table_
|
||||
for the support matrix of previous OpenStack versions.
|
||||
|
||||
Download Solutions Enabler and Unisphere from the Dell EMC's support web site
|
||||
(login is required). See the `Dell EMC Solutions Enabler 9.2.1 Installation
|
||||
(login is required). See the `Dell EMC Solutions Enabler 9.2.2 Installation
|
||||
and Configuration Guide` and `Dell EMC Unisphere for PowerMax Installation
|
||||
Guide` at the `Dell EMC Support`_ site.
|
||||
|
||||
@ -53,6 +61,8 @@ Guide` at the `Dell EMC Support`_ site.
|
||||
+-----------+------------------------+-------------+
|
||||
| OpenStack | Unisphere for PowerMax | PowerMax OS |
|
||||
+===========+========================+=============+
|
||||
| Xena | 9.2.2 | 5978.711 |
|
||||
+-----------+------------------------+-------------+
|
||||
| Wallaby | 9.2.1 | 5978.711 |
|
||||
+-----------+------------------------+-------------+
|
||||
| Victoria | 9.2.x | 5978.669 |
|
||||
@ -67,9 +77,9 @@ Guide` at the `Dell EMC Support`_ site.
|
||||
.. note::
|
||||
|
||||
A Hybrid array can only run HyperMax OS 5977, and is still supported until
|
||||
further notice. Some functionality will not be available in older versions
|
||||
of the OS. If in any doubt, please contact your local PowerMax
|
||||
representative.
|
||||
the ``Z`` release of OpenStack. Some functionality will not be available
|
||||
in older versions of the OS. If in any doubt, please contact your local
|
||||
PowerMax representative.
|
||||
|
||||
.. note::
|
||||
|
||||
@ -103,7 +113,7 @@ or the F package plus the SRDF a la carte add on is required.
|
||||
Hybrid
|
||||
~~~~~~
|
||||
|
||||
There are five Dell EMC Software Suites sold with the VMAX Hybrid arrays:
|
||||
There are five Dell EMC Software Suites sold with the VMAX-Hybrid_ arrays:
|
||||
|
||||
- Base Suite
|
||||
- Advanced Suite
|
||||
@ -314,7 +324,7 @@ contains ``child`` storage groups for each configured
|
||||
SRP/slo/workload/compression-enabled or disabled/replication-enabled or
|
||||
disabled combination.
|
||||
|
||||
PowerMax, VMAX All Flash and Hybrid
|
||||
PowerMax, VMAX All Flash and VMAX-Hybrid_
|
||||
|
||||
Parent storage group:
|
||||
|
||||
@ -606,15 +616,15 @@ associated with any service level).
|
||||
|
||||
.. note::
|
||||
|
||||
PowerMax and Hybrid support ``Diamond``, ``Platinum``, ``Gold``, ``Silver``,
|
||||
``Bronze``, ``Optimized``, and ``None`` service levels. VMAX All Flash
|
||||
running HyperMax OS (5977) supports ``Diamond`` and ``None``. Hybrid and All
|
||||
Flash support ``DSS_REP``, ``DSS``, ``OLTP_REP``, ``OLTP``, and ``None``
|
||||
workloads, the latter up until ucode 5977. Please refer to Stein PowerMax
|
||||
online documentation if you wish to use ``workload``. There is no support
|
||||
for workloads in PowerMax OS (5978) or greater. These will be silently
|
||||
ignored if set for VMAX All-Flash arrays which have been upgraded to
|
||||
PowerMax OS (5988).
|
||||
PowerMax and VMAX-Hybrid_ support ``Diamond``, ``Platinum``, ``Gold``,
|
||||
``Silver``, ``Bronze``, ``Optimized``, and ``None`` service
|
||||
levels. VMAX All Flash running HyperMax OS (5977) supports ``Diamond``
|
||||
and ``None``. VMAX-Hybrid_ and All Flash support ``DSS_REP``, ``DSS``,
|
||||
``OLTP_REP``, ``OLTP``, and ``None`` workloads, the latter up until
|
||||
ucode 5977. Please refer to Stein PowerMax online documentation if you
|
||||
wish to use ``workload``. There is no support for workloads in PowerMax
|
||||
OS (5978) or greater. These will be silently ignored if set for VMAX
|
||||
All-Flash arrays which have been upgraded to PowerMax OS (5988).
|
||||
|
||||
|
||||
7. Interval and retries
|
||||
@ -1296,8 +1306,9 @@ Use case 2 - Retype from compression disabled to compression enabled
|
||||
that storage group.
|
||||
|
||||
.. note::
|
||||
If extra spec ``storagetype:disablecompression`` is set on a Hybrid, it is
|
||||
ignored because compression is not an available feature on a VMAX3 Hybrid.
|
||||
If extra spec ``storagetype:disablecompression`` is set on a VMAX-Hybrid_,
|
||||
it is ignored because compression is not an available feature on a
|
||||
VMAX-Hybrid_.
|
||||
|
||||
|
||||
12. Oversubscription support
|
||||
@ -1765,8 +1776,8 @@ Assumptions, restrictions and prerequisites
|
||||
|
||||
- ODE in the context of this document refers to extending a volume where it
|
||||
is in-use, that is, attached to an instance.
|
||||
- The ``allow_extend`` is only applicable on Hybrid arrays or All Flash arrays
|
||||
with HyperMax OS. If included elsewhere, it is ignored.
|
||||
- The ``allow_extend`` is only applicable on VMAX-Hybrid_ arrays or All Flash
|
||||
arrays with HyperMax OS. If included elsewhere, it is ignored.
|
||||
- Where one array is a lower uCode than the other, the environment is limited
|
||||
to functionality of that of the lowest uCode level, i.e. if R1 is 5978.444
|
||||
and R2 is 5978.221, expanding a metro volume is not supported, both R1 and
|
||||
@ -2105,18 +2116,19 @@ Configure a single replication target
|
||||
* ``sync_retries`` How many times to retry RDF sync checks during Cinder
|
||||
PowerMax SRDF operations. Default is 200 retries.
|
||||
|
||||
* ``allow_extend`` Only applicable to Hybrid arrays or All Flash arrays
|
||||
running HyperMax OS (5977). It is a flag for allowing the extension of
|
||||
replicated volumes. To extend a volume in an SRDF relationship, this
|
||||
relationship must first be broken, the R1 device extended, and a new
|
||||
device pair established. If not explicitly set, this flag defaults to
|
||||
``False``.
|
||||
* ``allow_extend`` Only applicable to VMAX-Hybrid_ arrays or All Flash
|
||||
arrays running HyperMax OS (5977). It is a flag for
|
||||
allowing the extension of replicated volumes. To extend a volume in
|
||||
an SRDF relationship, this relationship must first be broken, the R1
|
||||
device extended, and a new device pair established. If not explicitly set,
|
||||
this flag defaults to ``False``.
|
||||
|
||||
.. note::
|
||||
|
||||
As the SRDF link must be severed, due caution should be exercised when
|
||||
performing this operation. If absolutely necessary, only one source and
|
||||
target pair should be extended at a time (only only applicable to
|
||||
Hybrid arrays or All Flash arrays with HyperMax OS).
|
||||
VMAX-Hybrid_ arrays or All Flash arrays with HyperMax OS).
|
||||
|
||||
|
||||
#. Create a ``replication-enabled`` volume type. Once the
|
||||
@ -2135,9 +2147,9 @@ Configure a single replication target
|
||||
group on the target array with the same service level and workload
|
||||
combination as the primary. However, if this combination is unavailable
|
||||
on the target (for example, in a situation where the source array is a
|
||||
Hybrid, the target array is an All Flash, and an All Flash incompatible
|
||||
service level like Bronze is configured), no service level will be
|
||||
applied.
|
||||
VMAX-Hybrid_, the target array is an All Flash, and an All
|
||||
Flash incompatible service level like Bronze is configured), no service
|
||||
level will be applied.
|
||||
|
||||
Configure multiple replication targets
|
||||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||
@ -2302,7 +2314,7 @@ Most features are supported, except for the following:
|
||||
to the user specific size.
|
||||
* Alternatively, ensure that the ``allow_extend`` option in the
|
||||
``replication_device parameter`` is set to ``True``. This is only
|
||||
applicable to Hybrid arrays or All Flash array with HyperMax OS.
|
||||
applicable to VMAX-Hybrid_ arrays or All Flash array with HyperMax OS.
|
||||
|
||||
|
||||
Failover host
|
||||
|
Loading…
x
Reference in New Issue
Block a user