@@ -15,28 +15,28 @@ to perform VMAX storage operations.
.. note::
KNOWN ISSUE:
Workload support was dropped in ucode 5978. If a VMAX All Flash array is
upgraded to 5978 or greater and existing volume types leveraged workload
e.g. DSS, DSS_REP, OLTP and OLTP_REP, attaching and detaching will no
longer work and the volume type will be unusable. Refrain from upgrading
to ucode 5978 or greater on an All Flash until a fix is merged. Please
contact your Dell EMC VMAX customer support representative if in any
doubt.
Workload support was dropped in PowerMax OS 5978. If a VMAX All Flash array
is upgraded to PowerMax OS 5978 or greater and existing volume types
leveraged workload i.e. DSS, DSS_REP, OLTP and OLTP_REP, attaching and
detaching will no longer work and the volume type will be unusable.
Refrain from upgrading to PowerMax OS 5978 or greater on an All Flash
until a fix is merged. Please contact your Dell EMC VMAX customer support
representative if in any doubt.
System requirements and licensing
=================================
The Dell EMC VMAX Cinder driver supports the VMAX-3 hybrid series and VMAX
All-Flash arrays.
The Dell EMC VMAX Cinder driver supports the VMAX-3 hybrid series, VMAX
All-Flash series and the PowerMax arrays.
The array operating system software, Solutions Enabler 8.4.0.7 or later, and
Unisphere for VMAX 8.4.0.15 or later are required to run Dell EMC VMAX Cinder
driver.
The array operating system software, Solutions Enabler 9.0.0.0 or later, and
Unisphere for PowerMax 9.0.0.6 or later are required to run Dell EMC VMAX
Cinder driver.
You can download Solutions Enabler and Unisphere from the Dell EMC's support
web site (login is required). See the ``Solutions Enabler 8.4.0 Installation
and Configuration Guide`` and ``Unisphere for VMAX 8.4.0 Installation Guide``
at ``support.emc.com``.
Download Solutions Enabler and Unisphere from the Dell EMC's support web site
(login is required). See the ``Dell EMC Solutions Enabler 9.0 Installation
and Configuration Guide`` and ``Dell EMC Unisphere for PowerMax Installation
Guide`` at ``support.emc.com``.
Required VMAX software suites for OpenStack
-------------------------------------------
@@ -110,6 +110,7 @@ VMAX drivers support these operations:
- Volume replication SRDF/S, SRDF/A and SRDF Metro
- Quality of service (QoS)
- Manage and unmanage volumes and snapshots
- List Manageable Volumes/Snapshots
VMAX drivers also support the following features:
@@ -119,8 +120,14 @@ VMAX drivers also support the following features:
- Oversubscription
- Service Level support
- SnapVX support
- Compression support(All Flash only)
- Compression support(All Flash and PowerMax)
- Deduplication support(PowerMax)
- CHAP Authentication
- Multi-attach support
- Volume Metadata in logs
- Encrypted Volume support
- Extending attached volume
- Replicated volume retype support
.. note::
@@ -186,7 +193,7 @@ contains ``child`` storage groups for each configured
SRP/slo/workload/compression-enabled or disabled/replication-enabled or
disabled combination.
VMAX All Flash and Hybrid
PowerMax, VMAX All Flash and Hybrid
Parent storage group:
@@ -205,6 +212,11 @@ Child storage groups:
CD and RE are only set if compression is explicitly disabled or replication
explicitly enabled. See the compression and replication sections below.
.. note::
For PowerMax and any All Flash with PowerMax OS (5978) or greater, workload
is NONE
VMAX Driver Integration
=======================
@@ -219,16 +231,15 @@ VMAX Driver Integration
Solutions Enabler can be installed on a physical server, or as a Virtual
Appliance (a VMware ESX server VM). Additionally, starting with HYPERMAX
OS Q3 2015, you can manage VMAX3 arrays using the Embedded Management
(eManagement) container application. See the ``Solutions Enabler 8.4.0
Installation and Configuration Guide`` on ``support.emc.com`` for more
details.
(eManagement) container application. See the ``Dell EMC Solutions Enabler
9.0 Installation and Configuration Guide`` on ``support.emc.com`` for
more details.
.. note::
You must discover storage arrays before you can use the VMAX drivers.
Follow instructions in ``Solutions Enabler 8.4.0 Installation and
Configuration Guide`` on ``support.emc.com`` for more
details.
Follow instructions in ```Dell EMC Solutions Enabler 9.0 Installation
and Configuration Guide`` on ``support.emc.com`` for more details.
#. Download Unisphere from ``support.emc.com`` and install it.
@@ -236,8 +247,8 @@ VMAX Driver Integration
- i.e., on the same server running Solutions Enabler; on a server
connected to the Solutions Enabler server; or using the eManagement
container application (containing Solutions Enabler and Unisphere for
VMAX). See ``Unisphere for VMAX 8.4.0 Installation Guide`` at
``support.emc.com``.
VMAX). See ``Dell EMC Solutions Enabler 9.0 Installation and Configuration
Guide`` at ``support.emc.com``.
2. FC Zoning with VMAX
@@ -296,6 +307,8 @@ complex and open-zoning would raise security concerns.
Service Level and workload can be added to the cinder.conf when the
backend is the default case and there is no associated volume type.
This not a recommended configuration as it is too restrictive.
Workload is NONE for PowerMax and any All Flash with PowerMax OS
(5978) or greater.
+-----------------+------------------------+---------+----------+
| VMAX parameter | cinder.conf parameter | Default | Required |
@@ -422,6 +435,8 @@ complex and open-zoning would raise security concerns.
is the additional property which has to be set and is of the format:
``<ServiceLevel>+<Workload>+<SRP>+<Array ID>``.
This can be obtained from the output of the ``cinder get-pools--detail``.
Workload is NONE for PowerMax or any All Flash with PowerMax OS (5978)
or greater.
.. code-block:: console
@@ -465,9 +480,12 @@ complex and open-zoning would raise security concerns.
.. note::
VMAX Hybrid supports Optimized, Diamond, Platinum, Gold, Silver, Bronze,
and NONE service levels. VMAX All Flash supports Diamond and None. Both
support DSS_REP, DSS, OLTP_REP, OLTP, and None workloads.
PowerMax and Hybrid support Optimized, Diamond, Platinum, Gold, Silver,
Bronze, and NONE service levels. VMAX All Flash supports Diamond and None.
Hybrid and All Flash support DSS_REP, DSS, OLTP_REP, OLTP, and None
workloads, the latter up until ucode 5977. There is no support for
workloads in PowerMax OS (5978) or greater.
7. Interval and Retries
-----------------------
@@ -1087,7 +1105,8 @@ uncompressed.
.. note::
This feature is only applicable for All Flash arrays, 250F, 450F or 850F.
This feature is only applicable for All Flash arrays, 250F, 450F, 850F
and 950F and PowerMax 2000 and 8000.
Use case 1 - Compression disabled create, attach, detach, and delete volume
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
@@ -1193,8 +1212,11 @@ Live migration configuration
Please refer to the following for more information:
https://docs.openstack.org/nova/queens/admin/live-migration-usage.html
https://docs.openstack.org/nova/queens/admin/configuring-migrations.html
https://docs.openstack.org/nova/latest/admin/live-migration-usage.html
and
https://docs.openstack.org/nova/latest/admin/configuring-migrations.html
.. note::
@@ -1373,6 +1395,55 @@ We then decide to detach the volume from Multi-attach-Instance-B on HostB:
storage group. The non-FAST managed storage group is cleaned up,
if required.
.. note::
Known issue - the multi-attach flag is still false after a retype. This
is being addressed in https://bugs.launchpad.net/cinder/+bug/1790840
15. Volume Encryption support
-----------------------------
Please refer to the following:
https://docs.openstack.org/cinder/latest/configuration/block-storage/volume-encryption.html
16. Volume metadata in logs
---------------------------
If debug is enabled in the default section of the cinder.conf, VMAX Cinder
driver will log additional volume information in the Cinder volume log,
on each successful operation. The facilitates bridging the gap between
OpenStack and the Array by tracing and describing the volume from a VMAX/
PowerMax view point.
.. code-block:: console
+-------------------------+---------------------------------------------------------+
| Key | Value |
+-------------------------+---------------------------------------------------------+
| service_level | Gold |
| is_compression_disabled | no |
| vmax_driver_version | 3.2.0 |
| identifier_name | OS-819470ab-a6d4-49cc-b4db-6f85e82822b7 |
| openstack_release | 13.0.0.0b3.dev3 |
| volume_id | 819470ab-a6d4-49cc-b4db-6f85e82822b7 |
| vmax_model | PowerMax_8000 |
| operation | delete |
| default_sg_name | OS-DEFAULT_SRP-Gold-NONE-SG |
| device_id | 01C03 |
| unisphere_version | V9.0.0.9 |
| workload | NONE |
| openstack_version | 13.0.0 |
| volume_updated_time | 2018-08-03 03:13:53 |
| platform | Linux-4.4.0-127-generic-x86_64-with-Ubuntu-16.04-xenial |
| python_version | 2.7.12 |
| volume_size | 20 |
| srp | DEFAULT_SRP |
| openstack_name | 91_Test_Vol56 |
| vmax_firmware_version | 5978.143.144 |
| serial_number | 000197600196 |
+-------------------------+---------------------------------------------------------+
Cinder supported operations
@@ -1626,6 +1697,15 @@ retype, follow these steps:
$ cinder retype --migration-policy on-demand <volume> <volume-type>
.. note::
With the Rocky release the following is now supported
- Retype non-replicated volume to a replicated volume type
- Retype replicated volume to a non-replicated volume type
- Retype a replicated volume to a different replicated volume type
Generic volume group support
----------------------------
@@ -2105,6 +2185,55 @@ the VMAX backend will have the ``OS-`` prefix removed to indicate it is no
longer OpenStack managed. In the example above, the snapshot after unmanaging
from OpenStack will be named ``VMAXSnapshot`` on the storage backend.
List manageable volumes and snapshots
-------------------------------------
Manageable volumes
~~~~~~~~~~~~~~~~~~
Volumes that can be managed by and imported into Openstack.
List manageable volume is filtered by:
- Volume size should be 1026MB or greater (1GB VMAX Cinder Vol = 1026 MB)
- Volume size should be a whole integer GB capacity
- Volume should not be a part of masking view.
- Volume status should be ``Ready``
- Volume service state should be ``Normal``
- Volume emulation type should be ``FBA``
- Volume configuration should be ``TDEV``
- Volume should not be a system resource.
- Volume should not be ``private``
- Volume should not be ``encapsulated``
- Volume should not be ``reserved``
- Volume should not be a part of an RDF session
- Volume should not be a snapVX Target
- Volume identifier should not begin with ``OS-``.
Manageable snaphots
~~~~~~~~~~~~~~~~~~~
Snapshots that can be managed by and imported into Openstack
List manageable snapshots is filtered by:
- The source volume should be marked as SnapVX source.
- The source volume should be 1026MB or greater
- The source volume should be a whole integer GB capacity.
- The source volume emulation type should be ``FBA``.
- The source volume configuration should be ``TDEV``.
- The source volume should not be ``private``.
- The source volume should be not be a system resource.
- The snapshot identifier should not start with ``OS-`` or ``temp-``.
- The snapshot should not be expired.
- The snapshot generation number should npt be greater than 0.
.. note::
There is some delay in the syncing of the Unisphere for PowerMax database
when the state/properties of a volume is modified using ``symcli``. To
prevent this it is preferrable to modify state/properties of volumes within
Unisphere.
Upgrading from SMI-S based driver to RESTAPI based driver
=========================================================