Merge "PowerMax Docs - corrections and improvements" into stable/train
This commit is contained in:
commit
6d78cc979b
|
@ -1,5 +1,5 @@
|
||||||
======================================
|
======================================
|
||||||
Dell EMC POWERMAX iSCSI and FC drivers
|
Dell EMC PowerMax iSCSI and FC drivers
|
||||||
======================================
|
======================================
|
||||||
|
|
||||||
The Dell EMC PowerMax drivers, ``PowerMaxISCSIDriver`` and
|
The Dell EMC PowerMax drivers, ``PowerMaxISCSIDriver`` and
|
||||||
|
@ -37,9 +37,50 @@ Download Solutions Enabler and Unisphere from the Dell EMC's support web site
|
||||||
and Configuration Guide`` and ``Dell EMC Unisphere for PowerMax Installation
|
and Configuration Guide`` and ``Dell EMC Unisphere for PowerMax Installation
|
||||||
Guide`` at ``support.emc.com``.
|
Guide`` at ``support.emc.com``.
|
||||||
|
|
||||||
|
.. note::
|
||||||
|
|
||||||
|
While it is not explicitly documented which OS versions should be
|
||||||
|
installed on a particular array, it is recommended to install the latest
|
||||||
|
PowerMax OS as supported by Unisphere for PowerMax, that the PowerMax
|
||||||
|
driver supports for a given OpenStack release.
|
||||||
|
|
||||||
|
+-----------+------------------------+-------------+
|
||||||
|
| OpenStack | Unisphere for PowerMax | PowerMax OS |
|
||||||
|
+===========+========================+=============+
|
||||||
|
| Train | 9.1.x | 5978.444 |
|
||||||
|
+-----------+------------------------+-------------+
|
||||||
|
| Stein | 9.0.x | 5978.221 |
|
||||||
|
+-----------+------------------------+-------------+
|
||||||
|
|
||||||
|
However, a Hybrid array can only run HyperMax OS 5977, and is still
|
||||||
|
supported until further notice. Some functionality will not be available
|
||||||
|
in older versions of the OS. If in any doubt, please contact your customer
|
||||||
|
representative.
|
||||||
|
|
||||||
|
|
||||||
|
|
||||||
Required PowerMax software suites for OpenStack
|
Required PowerMax software suites for OpenStack
|
||||||
-----------------------------------------------
|
-----------------------------------------------
|
||||||
|
|
||||||
|
The storage system requires a Unisphere for PowerMax (SMC) eLicense.
|
||||||
|
|
||||||
|
PowerMax
|
||||||
|
~~~~~~~~
|
||||||
|
There are two licenses for the PowerMax 2000 and 8000:
|
||||||
|
|
||||||
|
- Essentials software package
|
||||||
|
- Pro software package
|
||||||
|
|
||||||
|
The Dell EMC PowerMax cinder driver requires the Pro software package.
|
||||||
|
|
||||||
|
All Flash
|
||||||
|
~~~~~~~~~
|
||||||
|
For full functionality including SRDF for the VMAX All Flash, the FX package,
|
||||||
|
or the F package plus the SRDF a la carte add on is required.
|
||||||
|
|
||||||
|
Hybrid
|
||||||
|
~~~~~~
|
||||||
|
|
||||||
There are five Dell EMC Software Suites sold with the VMAX Hybrid arrays:
|
There are five Dell EMC Software Suites sold with the VMAX Hybrid arrays:
|
||||||
|
|
||||||
- Base Suite
|
- Base Suite
|
||||||
|
@ -55,13 +96,11 @@ Suite and the Local Replication Suite) for the VMAX Hybrid.
|
||||||
Using PowerMax Remote Replication functionality will also require the Remote
|
Using PowerMax Remote Replication functionality will also require the Remote
|
||||||
Replication Suite.
|
Replication Suite.
|
||||||
|
|
||||||
For full functionality including SRDF for the VMAX All Flash, the FX package,
|
|
||||||
or the F package plus the SRDF ``a la carte`` add on is required.
|
|
||||||
|
|
||||||
The storage system also requires a Unisphere for PowerMax (SMC) eLicence.
|
.. note::
|
||||||
|
|
||||||
Each are licensed separately. For further details on how to get the
|
Each are licensed separately. For further details on how to get the
|
||||||
relevant license(s), reference eLicensing Support below.
|
relevant license(s), reference eLicensing Support below.
|
||||||
|
|
||||||
|
|
||||||
eLicensing support
|
eLicensing support
|
||||||
|
@ -129,16 +168,9 @@ PowerMax drivers also support the following features:
|
||||||
- Extending attached volume
|
- Extending attached volume
|
||||||
- Replicated volume retype support
|
- Replicated volume retype support
|
||||||
- Retyping attached(in-use) volume
|
- Retyping attached(in-use) volume
|
||||||
- Unisphere high availability(HA) support
|
- Unisphere High Availability(HA) support
|
||||||
- Online device expansion of a metro device
|
- Online device expansion of a metro device
|
||||||
- Rapid tdev deallocation of deletes
|
- Rapid TDEV deallocation of deletes
|
||||||
|
|
||||||
.. note::
|
|
||||||
|
|
||||||
VMAX All Flash array with Solutions Enabler 8.3.0.11 or later have
|
|
||||||
compression enabled by default when associated with Diamond Service Level.
|
|
||||||
This means volumes added to any newly created storage groups will be
|
|
||||||
compressed.
|
|
||||||
|
|
||||||
|
|
||||||
PowerMax naming conventions
|
PowerMax naming conventions
|
||||||
|
@ -156,8 +188,8 @@ PowerMax naming conventions
|
||||||
1. Perform md5 hash on the shortHostName
|
1. Perform md5 hash on the shortHostName
|
||||||
2. Convert output of 1. to hex
|
2. Convert output of 1. to hex
|
||||||
3. Take last 6 characters of shortHostName and append output of 2.
|
3. Take last 6 characters of shortHostName and append output of 2.
|
||||||
4. If the length of output of 3. exceeds 16 characters
|
4. If the length of output of 3. exceeds 16 characters, join the
|
||||||
5. Add the first 8 characters and last 8 characters together
|
first 8 characters and last 8 characters.
|
||||||
|
|
||||||
.. note::
|
.. note::
|
||||||
|
|
||||||
|
@ -171,8 +203,8 @@ PowerMax naming conventions
|
||||||
1. Perform md5 hash on the portgroup_name
|
1. Perform md5 hash on the portgroup_name
|
||||||
2. Convert output of 1. to hex
|
2. Convert output of 1. to hex
|
||||||
3. Take last 6 characters of portgroup_name and append output of 2.
|
3. Take last 6 characters of portgroup_name and append output of 2.
|
||||||
4. If the length of output of 3. exceeds 12 characters
|
4. If the length of output of 3. exceeds 12 characters, join the
|
||||||
5. Add the first 6 characters and last 6 characters together
|
first 6 characters and last 6 characters.
|
||||||
|
|
||||||
|
|
||||||
Masking view names
|
Masking view names
|
||||||
|
@ -180,7 +212,7 @@ Masking view names
|
||||||
|
|
||||||
Masking views are dynamically created by the PowerMax FC and iSCSI drivers
|
Masking views are dynamically created by the PowerMax FC and iSCSI drivers
|
||||||
using the following naming conventions. ``[protocol]`` is either ``I`` for
|
using the following naming conventions. ``[protocol]`` is either ``I`` for
|
||||||
volumes attached over iSCSI or ``F`` for volumes attached over Fiber Channel.
|
volumes attached over iSCSI or ``F`` for volumes attached over Fibre Channel.
|
||||||
|
|
||||||
.. code-block:: text
|
.. code-block:: text
|
||||||
|
|
||||||
|
@ -196,7 +228,7 @@ each new attach volume operation, the PowerMax driver retrieves the initiators
|
||||||
(either WWNNs or IQNs) from OpenStack and adds or updates the contents of the
|
(either WWNNs or IQNs) from OpenStack and adds or updates the contents of the
|
||||||
Initiator Group as required. Names are of the following format. ``[protocol]``
|
Initiator Group as required. Names are of the following format. ``[protocol]``
|
||||||
is either ``I`` for volumes attached over iSCSI or ``F`` for volumes attached
|
is either ``I`` for volumes attached over iSCSI or ``F`` for volumes attached
|
||||||
over Fiber Channel.
|
over Fibre Channel.
|
||||||
|
|
||||||
.. code-block:: console
|
.. code-block:: console
|
||||||
|
|
||||||
|
@ -245,15 +277,16 @@ Child storage groups:
|
||||||
.. note::
|
.. note::
|
||||||
|
|
||||||
CD and RE are only set if compression is explicitly disabled or replication
|
CD and RE are only set if compression is explicitly disabled or replication
|
||||||
explicitly enabled. See the compression and replication sections below.
|
explicitly enabled. See the compression `11. All Flash compression support`_
|
||||||
|
and replication `Volume replication support`_ sections below.
|
||||||
|
|
||||||
.. note::
|
.. note::
|
||||||
|
|
||||||
For PowerMax and any All Flash with PowerMax OS (5978) or greater, workload
|
For PowerMax and any All Flash with PowerMax OS (5978) or greater, workload
|
||||||
is NONE
|
if set will be ignored and set to NONE
|
||||||
|
|
||||||
|
|
||||||
PowerMax Driver Integration
|
PowerMax driver integration
|
||||||
===========================
|
===========================
|
||||||
|
|
||||||
1. Prerequisites
|
1. Prerequisites
|
||||||
|
@ -286,7 +319,7 @@ PowerMax Driver Integration
|
||||||
Configuration Guide`` at ``support.emc.com``.
|
Configuration Guide`` at ``support.emc.com``.
|
||||||
|
|
||||||
|
|
||||||
2. FC Zoning with PowerMax
|
2. FC zoning with PowerMax
|
||||||
--------------------------
|
--------------------------
|
||||||
|
|
||||||
Zone Manager is required when there is a fabric between the host and array.
|
Zone Manager is required when there is a fabric between the host and array.
|
||||||
|
@ -296,8 +329,8 @@ complex and open-zoning would raise security concerns.
|
||||||
3. iSCSI with PowerMax
|
3. iSCSI with PowerMax
|
||||||
----------------------
|
----------------------
|
||||||
|
|
||||||
- Make sure the ``iscsi-initiator-utils`` package is installed on all Compute
|
- Make sure the ``open-iscsi`` package (or distro equivalent) is installed
|
||||||
nodes.
|
on all Compute nodes.
|
||||||
|
|
||||||
.. note::
|
.. note::
|
||||||
|
|
||||||
|
@ -305,15 +338,16 @@ complex and open-zoning would raise security concerns.
|
||||||
masking view. An attach operation creates this masking view.
|
masking view. An attach operation creates this masking view.
|
||||||
|
|
||||||
|
|
||||||
4. Configure Block Storage in cinder.conf
|
|
||||||
|
4. Configure block storage in cinder.conf
|
||||||
-----------------------------------------
|
-----------------------------------------
|
||||||
|
|
||||||
.. note::
|
.. note::
|
||||||
|
|
||||||
VMAX driver was rebranded to PowerMax in Stein, so some of the driver
|
VMAX driver was rebranded to PowerMax in Stein, so some of the driver
|
||||||
specific tags have also changed. Legacy tags like vmax_srp, vmax_array,
|
specific tags have also changed. Legacy tags like ``vmax_srp``,
|
||||||
vmax_service_level and vmax_port_group, as well as the old driver
|
``vmax_array``, ``vmax_service_level`` and ``vmax_port_group``, as well
|
||||||
location, will continue to work until the 'V' release.
|
as the old driver location, will continue to work until the 'V' release.
|
||||||
|
|
||||||
|
|
||||||
.. config-table::
|
.. config-table::
|
||||||
|
@ -322,13 +356,6 @@ complex and open-zoning would raise security concerns.
|
||||||
cinder.volume.drivers.dell_emc.powermax.common
|
cinder.volume.drivers.dell_emc.powermax.common
|
||||||
|
|
||||||
|
|
||||||
.. note::
|
|
||||||
|
|
||||||
For security and backend uniformity, the use of the XML file for PowerMax
|
|
||||||
backend configuration was deprecated in Queens and removed entirely
|
|
||||||
in Rocky.
|
|
||||||
|
|
||||||
|
|
||||||
.. note::
|
.. note::
|
||||||
|
|
||||||
``san_api_port`` is ``8443`` by default but can be changed if
|
``san_api_port`` is ``8443`` by default but can be changed if
|
||||||
|
@ -363,7 +390,7 @@ complex and open-zoning would raise security concerns.
|
||||||
+--------------------+----------------------------+---------+----------+
|
+--------------------+----------------------------+---------+----------+
|
||||||
|
|
||||||
|
|
||||||
Configure Block Storage in cinder.conf
|
Configure block storage in cinder.conf
|
||||||
|
|
||||||
Add the following entries to ``/etc/cinder/cinder.conf``:
|
Add the following entries to ``/etc/cinder/cinder.conf``:
|
||||||
|
|
||||||
|
@ -459,7 +486,7 @@ section describing unique parameters for connections, drivers and the
|
||||||
``cinder.conf`` backend stanza.
|
``cinder.conf`` backend stanza.
|
||||||
|
|
||||||
|
|
||||||
6. Create Volume Types
|
6. Create volume types
|
||||||
----------------------
|
----------------------
|
||||||
|
|
||||||
Once the ``cinder.conf`` has been updated, :command:`openstack` commands
|
Once the ``cinder.conf`` has been updated, :command:`openstack` commands
|
||||||
|
@ -515,15 +542,16 @@ associated with any service level).
|
||||||
|
|
||||||
.. note::
|
.. note::
|
||||||
|
|
||||||
PowerMax and Hybrid support Optimized, Diamond, Platinum, Gold, Silver,
|
PowerMax and Hybrid support ``Optimized``, ``Diamond``, ``Platinum``,
|
||||||
Bronze, and NONE service levels. VMAX All Flash supports Diamond and
|
``Gold``, ``Silver``, ``Bronze``, and ``NONE`` service levels. VMAX
|
||||||
None. Hybrid and All Flash support DSS_REP, DSS, OLTP_REP, OLTP, and None
|
All Flash supports ``Diamond`` and `None. Hybrid and All Flash support
|
||||||
workloads, the latter up until ucode 5977. Please refer to Stein PowerMax
|
``DSS_REP``, ``DSS``, ``OLTP_REP``, ``OLTP``, and None workloads, the
|
||||||
online documentation if you wish to use ``workload``. There is no support
|
latter up until ucode 5977. Please refer to Stein PowerMax online
|
||||||
|
documentation if you wish to use ``workload``. There is no support
|
||||||
for workloads in PowerMax OS (5978) or greater.
|
for workloads in PowerMax OS (5978) or greater.
|
||||||
|
|
||||||
|
|
||||||
7. Interval and Retries
|
7. Interval and retries
|
||||||
-----------------------
|
-----------------------
|
||||||
|
|
||||||
By default, ``interval`` and ``retries`` are ``3`` seconds and ``200`` retries
|
By default, ``interval`` and ``retries`` are ``3`` seconds and ``200`` retries
|
||||||
|
@ -554,32 +582,32 @@ Add the following lines to the PowerMax backend in the cinder.conf:
|
||||||
interval = 1
|
interval = 1
|
||||||
retries = 700
|
retries = 700
|
||||||
|
|
||||||
8. CHAP Authentication Support
|
8. CHAP authentication support
|
||||||
------------------------------
|
------------------------------
|
||||||
|
|
||||||
This supports one way initiator CHAP authentication functionality into the
|
This supports one-way initiator CHAP authentication functionality into the
|
||||||
PowerMax backend. With CHAP one-way authentication, the storage array
|
PowerMax backend. With CHAP one-way authentication, the storage array
|
||||||
challenges the host during the initial link negotiation process and expects
|
challenges the host during the initial link negotiation process and expects
|
||||||
to receive a valid credential and CHAP secret in response. When challenged,
|
to receive a valid credential and CHAP secret in response. When challenged,
|
||||||
the host transmits a CHAP credential and CHAP secret to the storage array.
|
the host transmits a CHAP credential and CHAP secret to the storage array.
|
||||||
The storagearray looks for this credential and CHAP secret which stored in
|
The storage array looks for this credential and CHAP secret which stored in
|
||||||
the host initiator's initiator group (IG) information in the ACLX database.
|
the host initiator's initiator group (IG) information in the ACLX database.
|
||||||
Once a positive authentication occurs, the storage array sends an acceptance
|
Once a positive authentication occurs, the storage array sends an acceptance
|
||||||
message to the host. However, if the storage array fails to find any record
|
message to the host. However, if the storage array fails to find any record
|
||||||
of the credential/secret pair, it sends a rejection message, and the link is
|
of the credential/secret pair, it sends a rejection message, and the link is
|
||||||
closed.
|
closed.
|
||||||
|
|
||||||
Assumptions, Restrictions and Pre-Requisites
|
Assumptions, restrictions and prerequisites
|
||||||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||||
|
|
||||||
#. The host initiator IQN is required along with the credentials the host
|
#. The host initiator IQN is required along with the credentials the host
|
||||||
initiator will use to log into the storage array with. The same credentials
|
initiator will use to log into the storage array with. The same credentials
|
||||||
should be used in a multi node system if connecting to the same array.
|
should be used in a multi node system if connecting to the same array.
|
||||||
|
|
||||||
#. Enable one way CHAP authentication for the iscsi initiator on the storage
|
#. Enable one-way CHAP authentication for the iSCSI initiator on the storage
|
||||||
array using SYMCLI. Template and example shown below. For the purpose of
|
array using SYMCLI. Template and example shown below. For the purpose of
|
||||||
this setup, the credential/secret used would be my_username/my_password
|
this setup, the credential/secret used would be my_username/my_password
|
||||||
with iscsi initiator of iqn.1991-05.com.company.lcseb130
|
with iSCSI initiator of iqn.1991-05.com.company.lcseb130
|
||||||
|
|
||||||
.. code-block:: console
|
.. code-block:: console
|
||||||
|
|
||||||
|
@ -593,7 +621,7 @@ Assumptions, Restrictions and Pre-Requisites
|
||||||
|
|
||||||
|
|
||||||
|
|
||||||
Settings and Configuration
|
Settings and configuration
|
||||||
~~~~~~~~~~~~~~~~~~~~~~~~~~
|
~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||||
|
|
||||||
#. Set the configuration in the PowerMax backend group in cinder.conf using the
|
#. Set the configuration in the PowerMax backend group in cinder.conf using the
|
||||||
|
@ -765,8 +793,8 @@ Prerequisites - PowerMax
|
||||||
Volume is created against volume type and QoS is enforced with the parameters
|
Volume is created against volume type and QoS is enforced with the parameters
|
||||||
above.
|
above.
|
||||||
|
|
||||||
USE CASE 2 - Preset limits
|
USE CASE 2 - Pre-set limits
|
||||||
~~~~~~~~~~~~~~~~~~~~~~~~~~
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||||
|
|
||||||
Prerequisites - PowerMax
|
Prerequisites - PowerMax
|
||||||
|
|
||||||
|
@ -889,8 +917,8 @@ The output of the command contains the xml below. It is found between the
|
||||||
</iotune>
|
</iotune>
|
||||||
|
|
||||||
|
|
||||||
USE CASE 3 - Preset limits
|
USE CASE 3 - Pre-set limits
|
||||||
~~~~~~~~~~~~~~~~~~~~~~~~~~
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||||
|
|
||||||
Prerequisites - PowerMax
|
Prerequisites - PowerMax
|
||||||
|
|
||||||
|
@ -1145,7 +1173,10 @@ uncompressed.
|
||||||
.. note::
|
.. note::
|
||||||
|
|
||||||
This feature is only applicable for All Flash arrays, 250F, 450F, 850F
|
This feature is only applicable for All Flash arrays, 250F, 450F, 850F
|
||||||
and 950F and PowerMax 2000 and 8000.
|
and 950F and PowerMax 2000 and 8000. It was first introduced Solutions
|
||||||
|
Enabler 8.3.0.11 or later and is enabled by default when associated with
|
||||||
|
a Service Level. This means volumes added to any newly created storage
|
||||||
|
groups will be compressed.
|
||||||
|
|
||||||
Use case 1 - Compression disabled create, attach, detach, and delete volume
|
Use case 1 - Compression disabled create, attach, detach, and delete volume
|
||||||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||||
|
@ -1195,7 +1226,7 @@ Please refer to the following:
|
||||||
:doc:`/admin/blockstorage-over-subscription`.
|
:doc:`/admin/blockstorage-over-subscription`.
|
||||||
|
|
||||||
|
|
||||||
13. Live Migration support
|
13. Live migration support
|
||||||
--------------------------
|
--------------------------
|
||||||
|
|
||||||
Non-live migration (sometimes referred to simply as 'migration'). The instance
|
Non-live migration (sometimes referred to simply as 'migration'). The instance
|
||||||
|
@ -1222,7 +1253,7 @@ Architecture
|
||||||
|
|
||||||
In PowerMax, A volume cannot belong to two or more FAST storage groups at the
|
In PowerMax, A volume cannot belong to two or more FAST storage groups at the
|
||||||
same time. To get around this limitation we leverage both cascaded storage
|
same time. To get around this limitation we leverage both cascaded storage
|
||||||
groups and a temporary non FAST storage group.
|
groups and a temporary non-FAST storage group.
|
||||||
|
|
||||||
A volume can remain 'live' if moved between masking views that have the same
|
A volume can remain 'live' if moved between masking views that have the same
|
||||||
initiator group and port groups which preserves the host path.
|
initiator group and port groups which preserves the host path.
|
||||||
|
@ -1236,7 +1267,7 @@ on the volume:
|
||||||
#. The volume is added to the FAST storage group within the destination
|
#. The volume is added to the FAST storage group within the destination
|
||||||
parent storage group of the destination masking view. At this point the
|
parent storage group of the destination masking view. At this point the
|
||||||
volume belongs to two storage groups.
|
volume belongs to two storage groups.
|
||||||
#. One of two things happens:
|
#. One of two things happen:
|
||||||
|
|
||||||
- If the connection to the destination instance is successful, the volume
|
- If the connection to the destination instance is successful, the volume
|
||||||
is removed from the non-FAST storage group in the originating masking
|
is removed from the non-FAST storage group in the originating masking
|
||||||
|
@ -1251,11 +1282,12 @@ Live migration configuration
|
||||||
|
|
||||||
Please refer to the following for more information:
|
Please refer to the following for more information:
|
||||||
|
|
||||||
https://docs.openstack.org/nova/latest/admin/live-migration-usage.html
|
https://docs.openstack.org/nova/latest/admin/configuring-migrations.html
|
||||||
|
|
||||||
and
|
and
|
||||||
|
|
||||||
https://docs.openstack.org/nova/latest/admin/configuring-migrations.html
|
https://docs.openstack.org/nova/latest/admin/live-migration-usage.html
|
||||||
|
|
||||||
|
|
||||||
.. note::
|
.. note::
|
||||||
|
|
||||||
|
@ -1326,7 +1358,7 @@ For our use case shown below, we have three hosts with host names HostA, HostB
|
||||||
and HostC. HostA is the compute node while HostB and HostC are the compute
|
and HostC. HostA is the compute node while HostB and HostC are the compute
|
||||||
nodes. The following were also used in live migration.
|
nodes. The following were also used in live migration.
|
||||||
|
|
||||||
- 2 gb bootable volume using the cirros image.
|
- 2 gb bootable volume using the CirrOS image.
|
||||||
- Instance created using the 2gb volume above with a flavor m1.small using
|
- Instance created using the 2gb volume above with a flavor m1.small using
|
||||||
2048 RAM, 20GB of Disk and 1 VCPU.
|
2048 RAM, 20GB of Disk and 1 VCPU.
|
||||||
|
|
||||||
|
@ -1390,7 +1422,7 @@ hosts/servers simultaneously. Please see
|
||||||
:doc:`/admin/blockstorage-volume-multiattach`
|
:doc:`/admin/blockstorage-volume-multiattach`
|
||||||
for configuration information.
|
for configuration information.
|
||||||
|
|
||||||
Multi-attach Architecture
|
Multi-attach architecture
|
||||||
~~~~~~~~~~~~~~~~~~~~~~~~~
|
~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||||
|
|
||||||
In PowerMax, a volume cannot belong to two or more FAST storage groups at the
|
In PowerMax, a volume cannot belong to two or more FAST storage groups at the
|
||||||
|
@ -1405,7 +1437,7 @@ no service level, workload, or SRP specified).
|
||||||
backend is required – the volume is attached to and detached from each
|
backend is required – the volume is attached to and detached from each
|
||||||
host as normal.
|
host as normal.
|
||||||
|
|
||||||
Example Use Case
|
Example use case
|
||||||
~~~~~~~~~~~~~~~~
|
~~~~~~~~~~~~~~~~
|
||||||
|
|
||||||
Volume ``Multi-attach-Vol-1`` (with a multi-attach capable volume type, and
|
Volume ``Multi-attach-Vol-1`` (with a multi-attach capable volume type, and
|
||||||
|
@ -1435,21 +1467,22 @@ We then decide to detach the volume from ‘Multi-attach-Instance-B’ on HostB:
|
||||||
storage group. The non-FAST managed storage group is cleaned up,
|
storage group. The non-FAST managed storage group is cleaned up,
|
||||||
if required.
|
if required.
|
||||||
|
|
||||||
.. note::
|
|
||||||
|
|
||||||
Known issue - the multi-attach flag is still false after a retype. This
|
15. Volume encryption support
|
||||||
is being addressed in https://bugs.launchpad.net/cinder/+bug/1790840
|
|
||||||
|
|
||||||
|
|
||||||
15. Volume Encryption support
|
|
||||||
-----------------------------
|
-----------------------------
|
||||||
|
|
||||||
Please refer to the following:
|
Please refer to the following:
|
||||||
:doc:`/configuration/block-storage/volume-encryption`.
|
:doc:`/configuration/block-storage/volume-encryption`.
|
||||||
|
|
||||||
|
|
||||||
16. Volume metadata in logs
|
16. Volume metadata
|
||||||
---------------------------
|
-------------------
|
||||||
|
|
||||||
|
Volume metadata is returned to the user in both the Cinder Volume logs and
|
||||||
|
with volumes and snapshots created in Cinder via the UI or CLI.
|
||||||
|
|
||||||
|
16.1 Volume metadata in logs
|
||||||
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||||
|
|
||||||
If debug is enabled in the default section of the cinder.conf, PowerMax Cinder
|
If debug is enabled in the default section of the cinder.conf, PowerMax Cinder
|
||||||
driver will log additional volume information in the Cinder volume log,
|
driver will log additional volume information in the Cinder volume log,
|
||||||
|
@ -1485,7 +1518,36 @@ PowerMax view point.
|
||||||
| serial_number | 000123456789 |
|
| serial_number | 000123456789 |
|
||||||
+------------------------------------+---------------------------------------------------------+
|
+------------------------------------+---------------------------------------------------------+
|
||||||
|
|
||||||
17. Unisphere high availability(HA) support
|
16.2 Metadata in the UI and CLI
|
||||||
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||||
|
|
||||||
|
By default metadata will be set on all volume and snapshot objects created in
|
||||||
|
Cinder. This information represents the state of the object on the backend
|
||||||
|
PowerMax and will change when volume attributes are changed by performing
|
||||||
|
actions on them such as re-type or attaching to an instance.
|
||||||
|
|
||||||
|
.. code-block:: console
|
||||||
|
|
||||||
|
demo@openstack-controller:~$ cinder show powermax-volume
|
||||||
|
|
||||||
|
+--------------------------------+------------------------------------------------------------+
|
||||||
|
| Property | Value |
|
||||||
|
+--------------------------------+------------------------------------------------------------+
|
||||||
|
| metadata | ArrayID : 000123456789 |
|
||||||
|
| | ArrayModel : PowerMax_8000 |
|
||||||
|
| | CompressionDisabled : False |
|
||||||
|
| | Configuration : TDEV |
|
||||||
|
| | DeviceID : 0012F |
|
||||||
|
| | DeviceLabel : OS-d87edb98-60fd-49dd-bb0f-cc388cf6f3f4 |
|
||||||
|
| | Emulation : FBA |
|
||||||
|
| | ReplicationEnabled : False |
|
||||||
|
| | ServiceLevel : Diamond |
|
||||||
|
| | Workload : None |
|
||||||
|
| name | powermax-volume |
|
||||||
|
+--------------------------------+------------------------------------------------------------+
|
||||||
|
|
||||||
|
|
||||||
|
17. Unisphere High Availability(HA) support
|
||||||
-------------------------------------------
|
-------------------------------------------
|
||||||
|
|
||||||
This feature facilitates high availability of Unisphere for PowerMax servers,
|
This feature facilitates high availability of Unisphere for PowerMax servers,
|
||||||
|
@ -1564,7 +1626,7 @@ restarted for changes to take effect.
|
||||||
used by the PowerMax driver.
|
used by the PowerMax driver.
|
||||||
|
|
||||||
|
|
||||||
18. Rapid TDEV Deallocation
|
18. Rapid TDEV deallocation
|
||||||
---------------------------
|
---------------------------
|
||||||
|
|
||||||
The PowerMax driver can now leverage the enhanced volume delete feature-set
|
The PowerMax driver can now leverage the enhanced volume delete feature-set
|
||||||
|
@ -1579,7 +1641,7 @@ compliant volume deletion sequence based on the connected PowerMax array’s
|
||||||
metadata.
|
metadata.
|
||||||
|
|
||||||
|
|
||||||
19. PowerMax Online (in-use) Device Expansion
|
19. PowerMax online (in-use) device expansion
|
||||||
---------------------------------------------
|
---------------------------------------------
|
||||||
|
|
||||||
.. table::
|
.. table::
|
||||||
|
@ -1589,27 +1651,27 @@ metadata.
|
||||||
+----------------+----------------+--------------+--------------+-------------+
|
+----------------+----------------+--------------+--------------+-------------+
|
||||||
| R1 uCode Level | R2 uCode Level | Sync | Async | Metro |
|
| R1 uCode Level | R2 uCode Level | Sync | Async | Metro |
|
||||||
+================+================+==============+==============+=============+
|
+================+================+==============+==============+=============+
|
||||||
| 5979 | 5979 | Y | Y | Y |
|
| 5978.444 | 5978.444 | Y | Y | Y |
|
||||||
+----------------+----------------+--------------+--------------+-------------+
|
+----------------+----------------+--------------+--------------+-------------+
|
||||||
| 5979 | 5978 | Y | Y | N |
|
| 5978.444 | 5978.221 | Y | Y | N |
|
||||||
+----------------+----------------+--------------+--------------+-------------+
|
+----------------+----------------+--------------+--------------+-------------+
|
||||||
| 5978 | 5978 | Y | Y | N |
|
| 5978.221 | 5978.221 | Y | Y | N |
|
||||||
+----------------+----------------+--------------+--------------+-------------+
|
+----------------+----------------+--------------+--------------+-------------+
|
||||||
|
|
||||||
|
|
||||||
Assumptions, Restrictions and Pre-Requisites
|
Assumptions, restrictions and prerequisites
|
||||||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||||
|
|
||||||
- ODE in the context of this document refers to extending a volume where it
|
- ODE in the context of this document refers to extending a volume where it
|
||||||
is in-use, that is, attached to an instance.
|
is in-use, that is, attached to an instance.
|
||||||
- The ``allow_extend`` is only applicable on Hybrid arrays or All Flash arrays
|
- The ``allow_extend`` is only applicable on Hybrid arrays or All Flash arrays
|
||||||
with HyperMax OS. If included elsewhere, it is ignored.
|
with HyperMax OS. If included elsewhere, it is ignored.
|
||||||
- Extending a Metro volume is blocked for all replication sessions where both
|
- Extending a Metro volume is blocked for all replication sessions where both
|
||||||
R1 and R2 arrays are not PowerMax OS 5979 or newer.
|
R1 and R2 arrays are not PowerMax OS 5978.444 or newer.
|
||||||
- Where one array is a lower uCode than the other, the environment is limited
|
- Where one array is a lower uCode than the other, the environment is limited
|
||||||
to functionality of that of the lowest uCode level, i.e. if R1 is 5979 and
|
to functionality of that of the lowest uCode level, i.e. if R1 is 5978.444
|
||||||
R2 is 5978, expanding a metro volume is not supported, both R1 and R2 need
|
and R2 is 5978.221, expanding a metro volume is not supported, both R1 and
|
||||||
to be on 5979 uCode.
|
R2 need to be on 5978.444 uCode.
|
||||||
|
|
||||||
Cinder supported operations
|
Cinder supported operations
|
||||||
===========================
|
===========================
|
||||||
|
@ -1690,7 +1752,7 @@ Configure the source and target arrays
|
||||||
|
|
||||||
* ``remote_port_group`` is the name of a PowerMax port group that has been
|
* ``remote_port_group`` is the name of a PowerMax port group that has been
|
||||||
pre-configured to expose volumes managed by this backend in the event
|
pre-configured to expose volumes managed by this backend in the event
|
||||||
of a failover. Make sure that this portgroup contains either all FC or
|
of a failover. Make sure that this port group contains either all FC or
|
||||||
all iSCSI port groups (for a given back end), as appropriate for the
|
all iSCSI port groups (for a given back end), as appropriate for the
|
||||||
configured driver (iSCSI or FC).
|
configured driver (iSCSI or FC).
|
||||||
|
|
||||||
|
@ -1749,7 +1811,7 @@ Configure the source and target arrays
|
||||||
``replication_device`` parameter has been entered in the PowerMax
|
``replication_device`` parameter has been entered in the PowerMax
|
||||||
backend entry in the ``cinder.conf``, a corresponding volume type
|
backend entry in the ``cinder.conf``, a corresponding volume type
|
||||||
needs to be created ``replication_enabled`` property set. See
|
needs to be created ``replication_enabled`` property set. See
|
||||||
above ``Setup PowerMax drivers`` for details.
|
above `6. Create volume types`_ for details.
|
||||||
|
|
||||||
.. code-block:: console
|
.. code-block:: console
|
||||||
|
|
||||||
|
@ -1791,6 +1853,11 @@ Most features are supported, except for the following:
|
||||||
Failover host
|
Failover host
|
||||||
~~~~~~~~~~~~~
|
~~~~~~~~~~~~~
|
||||||
|
|
||||||
|
.. note::
|
||||||
|
|
||||||
|
Failover and Failback operations are not applicable in Metro
|
||||||
|
configurations.
|
||||||
|
|
||||||
In the event of a disaster, or where there is required downtime, upgrade
|
In the event of a disaster, or where there is required downtime, upgrade
|
||||||
of the primary array for example, the administrator can issue the failover
|
of the primary array for example, the administrator can issue the failover
|
||||||
host command to failover to the configured target:
|
host command to failover to the configured target:
|
||||||
|
@ -1799,22 +1866,38 @@ host command to failover to the configured target:
|
||||||
|
|
||||||
# cinder failover-host cinder_host@POWERMAX_FC_REPLICATION
|
# cinder failover-host cinder_host@POWERMAX_FC_REPLICATION
|
||||||
|
|
||||||
If the primary array becomes available again, you can initiate a failback
|
After issuing Cinder failover-host command Cinder will set the R2 array as the
|
||||||
using the same command and specifying ``--backend_id default``:
|
target array for Cinder, however to get existing instances to use this new
|
||||||
|
array and paths to volumes it is necessary to first shelve Nova instances and
|
||||||
|
then unshelve them, this will effectively restart the Nova instance and
|
||||||
|
re-establish data paths between Nova instances and the volumes on the R2 array.
|
||||||
|
|
||||||
|
.. code-block:: console
|
||||||
|
|
||||||
|
# nova shelve <server>
|
||||||
|
# nova unshelve [--availability-zone <availability_zone>] <server>
|
||||||
|
|
||||||
|
When a host is in failover mode performing normal volume or snapshot
|
||||||
|
provisioning will not be possible, failover-host mode simply provides access
|
||||||
|
to replicated volumes to minimise environment down-time. The primary objective
|
||||||
|
whilst in failover mode should be to get the R1 array back online. When the
|
||||||
|
primary array becomes available again, you can initiate a failback using the
|
||||||
|
same failover command and specifying --backend_id default:
|
||||||
|
|
||||||
.. code-block:: console
|
.. code-block:: console
|
||||||
|
|
||||||
# cinder failover-host cinder_host@POWERMAX_FC_REPLICATION --backend_id default
|
# cinder failover-host cinder_host@POWERMAX_FC_REPLICATION --backend_id default
|
||||||
|
|
||||||
.. note::
|
After issuing the failover command to revert to the default backend host it is
|
||||||
|
necessary to re-issue the Nova shelve and unshelve commands to restore the
|
||||||
|
data paths between Nova instances and their corresponding back end volumes.
|
||||||
|
Once reverted to the default backend volume and snapshot provisioning
|
||||||
|
operations can continue as normal.
|
||||||
|
|
||||||
Failover and Failback operations are not applicable in Metro configurations.
|
Asynchronous and metro replication management groups
|
||||||
|
|
||||||
|
|
||||||
Asynchronous and Metro replication management groups
|
|
||||||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||||
|
|
||||||
Asynchronous and Metro volumes in an RDF session, i.e. belonging to an SRDF
|
Asynchronous and metro volumes in an RDF session, i.e. belonging to an SRDF
|
||||||
group, must be managed together for RDF operations (although there is a
|
group, must be managed together for RDF operations (although there is a
|
||||||
``consistency exempt`` option for creating and deleting pairs in an Async
|
``consistency exempt`` option for creating and deleting pairs in an Async
|
||||||
group). To facilitate this management, we create an internal RDF management
|
group). To facilitate this management, we create an internal RDF management
|
||||||
|
@ -1827,7 +1910,7 @@ group. For this reason, it is imperative that the RDF group specified in the
|
||||||
Metro support
|
Metro support
|
||||||
~~~~~~~~~~~~~
|
~~~~~~~~~~~~~
|
||||||
|
|
||||||
SRDF/Metro is a High Availabilty solution. It works by masking both sides of
|
SRDF/Metro is a high availability solution. It works by masking both sides of
|
||||||
the RDF relationship to the host, and presenting all paths to the host,
|
the RDF relationship to the host, and presenting all paths to the host,
|
||||||
appearing that they all point to the one device. In order to do this,
|
appearing that they all point to the one device. In order to do this,
|
||||||
there needs to be multipath software running to manage writing to the
|
there needs to be multipath software running to manage writing to the
|
||||||
|
@ -1854,7 +1937,7 @@ Known issues
|
||||||
replication volume type.
|
replication volume type.
|
||||||
|
|
||||||
|
|
||||||
Volume retype - storage assisted volume migration
|
Volume retype - storage assisted volume migration
|
||||||
--------------------------------------------------
|
--------------------------------------------------
|
||||||
|
|
||||||
Volume retype with storage assisted migration is supported now for
|
Volume retype with storage assisted migration is supported now for
|
||||||
|
@ -1866,7 +1949,7 @@ retype, follow these steps:
|
||||||
another, use volume retype with the migration-policy to on-demand. The
|
another, use volume retype with the migration-policy to on-demand. The
|
||||||
target volume type should have the same volume_backend_name configured and
|
target volume type should have the same volume_backend_name configured and
|
||||||
should have the desired pool_name to which you are trying to retype to
|
should have the desired pool_name to which you are trying to retype to
|
||||||
(please refer to ``Setup PowerMax Drivers`` for details).
|
(please refer to `6. Create volume types`_ for details).
|
||||||
|
|
||||||
.. code-block:: console
|
.. code-block:: console
|
||||||
|
|
||||||
|
@ -1884,7 +1967,7 @@ retype, follow these steps:
|
||||||
|
|
||||||
.. note::
|
.. note::
|
||||||
|
|
||||||
With the Stein release, In Use (attached) volume retype is supported
|
With the Stein release, in-use (attached) volume retype is supported
|
||||||
|
|
||||||
|
|
||||||
Generic volume group support
|
Generic volume group support
|
||||||
|
@ -1944,7 +2027,7 @@ without failing over the entire host. See below for usage.
|
||||||
A generic volume group can be both consistent group snapshot enabled and
|
A generic volume group can be both consistent group snapshot enabled and
|
||||||
consistent group replication enabled.
|
consistent group replication enabled.
|
||||||
|
|
||||||
Storage Group Names
|
Storage group names
|
||||||
~~~~~~~~~~~~~~~~~~~
|
~~~~~~~~~~~~~~~~~~~
|
||||||
|
|
||||||
Storage groups are created on the PowerMax as a result of creation of generic
|
Storage groups are created on the PowerMax as a result of creation of generic
|
||||||
|
@ -1956,113 +2039,22 @@ name.
|
||||||
|
|
||||||
TruncatedGroupName_GroupUUID or GroupUUID
|
TruncatedGroupName_GroupUUID or GroupUUID
|
||||||
|
|
||||||
Group type operations
|
Group type, group and group snapshot operations
|
||||||
~~~~~~~~~~~~~~~~~~~~~
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||||
|
|
||||||
- Create a group type
|
Please refer to the following section for the most up to date group type
|
||||||
|
group and group replication operations https://docs.openstack.org/cinder/latest/admin/blockstorage-groups.html
|
||||||
.. code-block:: console
|
|
||||||
|
|
||||||
cinder --os-volume-api-version 3.11 group-type-create GROUP_TYPE
|
|
||||||
|
|
||||||
- Show a group type
|
|
||||||
|
|
||||||
.. code-block:: console
|
|
||||||
|
|
||||||
cinder --os-volume-api-version 3.11 group-type-show GROUP_TYPE
|
|
||||||
|
|
||||||
- List group types
|
|
||||||
|
|
||||||
.. code-block:: console
|
|
||||||
|
|
||||||
cinder --os-volume-api-version 3.11 group-type-list
|
|
||||||
|
|
||||||
- Delete group type
|
|
||||||
|
|
||||||
.. code-block:: console
|
|
||||||
|
|
||||||
cinder --os-volume-api-version 3.11 group-type-delete GROUP_TYPE
|
|
||||||
|
|
||||||
- Set/unset a group spec
|
|
||||||
|
|
||||||
.. code-block:: console
|
|
||||||
|
|
||||||
cinder --os-volume-api-version 3.11 group-type-key GROUP_TYPE set consistent_group_snapshot_enabled="<is> True"
|
|
||||||
|
|
||||||
- List group types and group specs:
|
|
||||||
|
|
||||||
.. code-block:: console
|
|
||||||
|
|
||||||
cinder --os-volume-api-version 3.11 group-specs-list
|
|
||||||
|
|
||||||
Group operations
|
|
||||||
~~~~~~~~~~~~~~~~
|
|
||||||
|
|
||||||
- Create a group:
|
|
||||||
|
|
||||||
.. code-block:: console
|
|
||||||
|
|
||||||
cinder --os-volume-api-version 3.13 group-create --name GROUP GROUP_TYPE VOLUME_TYPE1,VOLUME_TYPE2
|
|
||||||
|
|
||||||
- Show a group:
|
|
||||||
|
|
||||||
.. code-block:: console
|
|
||||||
|
|
||||||
cinder --os-volume-api-version 3.13 group-show GROUP
|
|
||||||
|
|
||||||
- List all groups:
|
|
||||||
|
|
||||||
.. code-block:: console
|
|
||||||
|
|
||||||
cinder --os-volume-api-version 3.13 group-list
|
|
||||||
|
|
||||||
- Create a volume and add it to a group at the time of creation:
|
|
||||||
|
|
||||||
.. code-block:: console
|
|
||||||
|
|
||||||
cinder --os-volume-api-version 3.13 create --volume-type VOLUME_TYPE1 --group-id GROUP_ID 1
|
|
||||||
|
|
||||||
- Modify a group to add or remove volumes:
|
|
||||||
|
|
||||||
.. code-block:: console
|
|
||||||
|
|
||||||
cinder --os-volume-api-version 3.13 group-update --add-volumes UUID1,UUID2 --remove-volumes UUID3,UUID4 GROUP
|
|
||||||
|
|
||||||
- Delete a group
|
|
||||||
|
|
||||||
.. code-block:: console
|
|
||||||
|
|
||||||
cinder --os-volume-api-version 3.13 group-delete --delete-volumes GROUP
|
|
||||||
|
|
||||||
Group snapshot operations
|
|
||||||
~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
||||||
|
|
||||||
- Create a group snapshot:
|
|
||||||
|
|
||||||
.. code-block:: console
|
|
||||||
|
|
||||||
cinder --os-volume-api-version 3.14 group-snapshot-create --name GROUP_SNAPSHOT GROUP
|
|
||||||
|
|
||||||
- Delete group snapshot(s):
|
|
||||||
|
|
||||||
.. code-block:: console
|
|
||||||
|
|
||||||
cinder --os-volume-api-version 3.14 group-snapshot-delete GROUP_SNAPSHOT
|
|
||||||
|
|
||||||
- Create a group from a group snapshot:
|
|
||||||
|
|
||||||
.. code-block:: console
|
|
||||||
|
|
||||||
$ cinder --os-volume-api-version 3.14 group-create-from-src --group-snapshot GROUP_SNAPSHOT --name GROUP
|
|
||||||
|
|
||||||
- Create a group from a source snapshot:
|
|
||||||
|
|
||||||
.. code-block:: console
|
|
||||||
|
|
||||||
$ cinder --os-volume-api-version 3.14 group-create-from-src --source-group SOURCE_GROUP --name GROUP
|
|
||||||
|
|
||||||
Group replication operations
|
Group replication operations
|
||||||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||||
|
Generic volume group operations no longer require the user to specify the
|
||||||
|
Cinder CLI version, however, performing generic volume group replication
|
||||||
|
operations still require this setting. When running generic volume group
|
||||||
|
commands set the value --os-volume-api-version to 3.38.
|
||||||
|
These commands are not listed in the latest Cinder CLI documentation so
|
||||||
|
will remain here until added to the latest Cinder CLI version or
|
||||||
|
deprecated from Cinder.
|
||||||
|
|
||||||
|
|
||||||
- Enable group replication
|
- Enable group replication
|
||||||
|
|
||||||
|
@ -2090,7 +2082,7 @@ Group replication operations
|
||||||
--secondary-backend-id default
|
--secondary-backend-id default
|
||||||
|
|
||||||
|
|
||||||
Manage and Unmanage Volumes
|
Manage and unmanage Volumes
|
||||||
---------------------------
|
---------------------------
|
||||||
|
|
||||||
Managing volumes in OpenStack is the process whereby a volume which exists
|
Managing volumes in OpenStack is the process whereby a volume which exists
|
||||||
|
@ -2110,7 +2102,7 @@ OpenStack, the following prerequisites must be met:
|
||||||
|
|
||||||
- The volume must a whole GB e.g. 5.5GB is not a valid size
|
- The volume must a whole GB e.g. 5.5GB is not a valid size
|
||||||
|
|
||||||
- The volume cannot be a snapvx target
|
- The volume cannot be a SnapVX target
|
||||||
|
|
||||||
|
|
||||||
For a volume to exist in a Cinder managed pool, it must reside in the same
|
For a volume to exist in a Cinder managed pool, it must reside in the same
|
||||||
|
@ -2137,7 +2129,7 @@ the same format:
|
||||||
- The PowerMax serial number (12 digit numerical)
|
- The PowerMax serial number (12 digit numerical)
|
||||||
|
|
||||||
|
|
||||||
Manage Volumes
|
Manage volumes
|
||||||
~~~~~~~~~~~~~~
|
~~~~~~~~~~~~~~
|
||||||
|
|
||||||
With your pool name defined you can now manage the volume into OpenStack, this
|
With your pool name defined you can now manage the volume into OpenStack, this
|
||||||
|
@ -2171,7 +2163,7 @@ the same way as any other OpenStack PowerMax volume.
|
||||||
PowerMax driver on a manage operation.
|
PowerMax driver on a manage operation.
|
||||||
|
|
||||||
|
|
||||||
Managing Volumes with Replication Enabled
|
Managing volumes with replication enabled
|
||||||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||||
|
|
||||||
Whilst it is not possible to manage volumes into OpenStack that are part of a
|
Whilst it is not possible to manage volumes into OpenStack that are part of a
|
||||||
|
@ -2183,7 +2175,7 @@ volume type as the chosen volume type. Once managed, replication will be
|
||||||
enabled for that volume.
|
enabled for that volume.
|
||||||
|
|
||||||
|
|
||||||
Unmanage Volume
|
Unmanage volume
|
||||||
~~~~~~~~~~~~~~~
|
~~~~~~~~~~~~~~~
|
||||||
|
|
||||||
Unmanaging a volume is not the same as deleting a volume. When a volume is
|
Unmanaging a volume is not the same as deleting a volume. When a volume is
|
||||||
|
@ -2212,7 +2204,7 @@ the 'OS-' prefix has been removed, this is another visual indication that
|
||||||
the volume is no longer managed by OpenStack.
|
the volume is no longer managed by OpenStack.
|
||||||
|
|
||||||
|
|
||||||
Manage/Unmanage Snapshots
|
Manage/unmanage snapshots
|
||||||
-------------------------
|
-------------------------
|
||||||
|
|
||||||
Users can manage PowerMax SnapVX snapshots into OpenStack if the source volume
|
Users can manage PowerMax SnapVX snapshots into OpenStack if the source volume
|
||||||
|
@ -2231,7 +2223,7 @@ Set-up, restrictions and requirements:
|
||||||
|
|
||||||
#. It is only possible to manage or unmanage one snapshot at a time in Cinder.
|
#. It is only possible to manage or unmanage one snapshot at a time in Cinder.
|
||||||
|
|
||||||
Manage SnapVX Snapshot
|
Manage SnapVX snapshot
|
||||||
~~~~~~~~~~~~~~~~~~~~~~
|
~~~~~~~~~~~~~~~~~~~~~~
|
||||||
|
|
||||||
It is possible to manage PowerMax SnapVX snapshots into OpenStack, where the
|
It is possible to manage PowerMax SnapVX snapshots into OpenStack, where the
|
||||||
|
@ -2247,7 +2239,7 @@ the restriction around managing SnapVX source volumes has been removed.
|
||||||
or volumes which exist in a replication session.
|
or volumes which exist in a replication session.
|
||||||
|
|
||||||
|
|
||||||
Requirements/Restrictions:
|
Requirements/restrictions:
|
||||||
|
|
||||||
#. The SnapVX source volume must be present in and managed by Cinder.
|
#. The SnapVX source volume must be present in and managed by Cinder.
|
||||||
|
|
||||||
|
@ -2259,7 +2251,7 @@ Requirements/Restrictions:
|
||||||
linked target volumes.
|
linked target volumes.
|
||||||
|
|
||||||
|
|
||||||
Command Structure:
|
Command structure:
|
||||||
|
|
||||||
#. Identify your SnapVX snapshot for management on the PowerMax, note the name.
|
#. Identify your SnapVX snapshot for management on the PowerMax, note the name.
|
||||||
|
|
||||||
|
@ -2321,7 +2313,7 @@ snapshot in this example named ``OS-PowerMaxSnapshot``. The associated snapshot
|
||||||
managed by Cinder will be present for use under the name ``SnapshotManaged``.
|
managed by Cinder will be present for use under the name ``SnapshotManaged``.
|
||||||
|
|
||||||
|
|
||||||
Unmanage Cinder Snapshot
|
Unmanage cinder snapshot
|
||||||
~~~~~~~~~~~~~~~~~~~~~~~~
|
~~~~~~~~~~~~~~~~~~~~~~~~
|
||||||
|
|
||||||
Unmanaging a snapshot in Cinder is the process whereby the snapshot is removed
|
Unmanaging a snapshot in Cinder is the process whereby the snapshot is removed
|
||||||
|
@ -2386,7 +2378,7 @@ List manageable volume is filtered by:
|
||||||
- Volume should not be ``encapsulated``
|
- Volume should not be ``encapsulated``
|
||||||
- Volume should not be ``reserved``
|
- Volume should not be ``reserved``
|
||||||
- Volume should not be a part of an RDF session
|
- Volume should not be a part of an RDF session
|
||||||
- Volume should not be a snapVX Target
|
- Volume should not be a SnapVX Target
|
||||||
- Volume identifier should not begin with ``OS-``.
|
- Volume identifier should not begin with ``OS-``.
|
||||||
|
|
||||||
Manageable snaphots
|
Manageable snaphots
|
||||||
|
@ -2411,7 +2403,7 @@ List manageable snapshots is filtered by:
|
||||||
|
|
||||||
There is some delay in the syncing of the Unisphere for PowerMax database
|
There is some delay in the syncing of the Unisphere for PowerMax database
|
||||||
when the state/properties of a volume is modified using ``symcli``. To
|
when the state/properties of a volume is modified using ``symcli``. To
|
||||||
prevent this it is preferrable to modify state/properties of volumes within
|
prevent this it is preferable to modify state/properties of volumes within
|
||||||
Unisphere.
|
Unisphere.
|
||||||
|
|
||||||
|
|
||||||
|
@ -2430,10 +2422,17 @@ Upgrading from SMI-S based driver to RESTAPI based driver
|
||||||
Seamless upgrades from an SMI-S based driver to RESTAPI based driver,
|
Seamless upgrades from an SMI-S based driver to RESTAPI based driver,
|
||||||
following the setup instructions above, are supported with a few exceptions:
|
following the setup instructions above, are supported with a few exceptions:
|
||||||
|
|
||||||
#. Live migration functionality will not work on already attached/in-use
|
#. OpenStack's ``live migration`` functionality will not work on already
|
||||||
legacy volumes. These volumes will first need to be detached and reattached
|
attached/in-use legacy volumes without first migrating the volumes to
|
||||||
using the RESTAPI based driver. This is because we have changed the masking
|
the new REST masking view structure. This can be done by running the
|
||||||
view architecture from Pike to better support this functionality.
|
migrate.py script in PyU4V. Please refer to the Tools Guide in PyU4V_.
|
||||||
|
|
||||||
|
.. code-block:: text
|
||||||
|
|
||||||
|
$ pip install PyU4V
|
||||||
|
|
||||||
|
|
||||||
#. Consistency groups are deprecated in Pike. Generic Volume Groups are
|
#. Consistency groups are deprecated in Pike. Generic Volume Groups are
|
||||||
supported from Pike onwards.
|
supported from Pike onwards.
|
||||||
|
|
||||||
|
.. _PyU4V: https://pyu4v.readthedocs.io/en/latest/
|
||||||
|
|
Loading…
Reference in New Issue