Dell EMC POWERMAX iSCSI and FC drivers Dell EMC PowerMax iSCSI and FC drivers
====================================== ======================================
The Dell EMC PowerMax drivers, ``PowerMaxISCSIDriver`` and The Dell EMC PowerMax drivers, ``PowerMaxISCSIDriver`` and
@ -37,9 +37,50 @@ Download Solutions Enabler and Unisphere from the Dell EMC's support web site
and Configuration Guide`` and ``Dell EMC Unisphere for PowerMax Installation and Configuration Guide`` and ``Dell EMC Unisphere for PowerMax Installation
Guide`` at ``support.emc.com``. Guide`` at ``support.emc.com``.
.. note::
While it is not explicitly documented which OS versions should be
installed on a particular array, it is recommended to install the latest
PowerMax OS as supported by Unisphere for PowerMax, that the PowerMax
driver supports for a given OpenStack release.
+-----------+------------------------+-------------+
| OpenStack | Unisphere for PowerMax | PowerMax OS |
+===========+========================+=============+
| Train | 9.1.x | 5978.444 |
+-----------+------------------------+-------------+
| Stein | 9.0.x | 5978.221 |
+-----------+------------------------+-------------+
However, a Hybrid array can only run HyperMax OS 5977, and is still
supported until further notice. Some functionality will not be available
in older versions of the OS. If in any doubt, please contact your customer
representative.
Required PowerMax software suites for OpenStack Required PowerMax software suites for OpenStack
----------------------------------------------- -----------------------------------------------
The storage system requires a Unisphere for PowerMax (SMC) eLicense.
PowerMax
~~~~~~~~
There are two licenses for the PowerMax 2000 and 8000:
- Essentials software package
- Pro software package
The Dell EMC PowerMax cinder driver requires the Pro software package.
All Flash
~~~~~~~~~
For full functionality including SRDF for the VMAX All Flash, the FX package,
or the F package plus the SRDF a la carte add on is required.
Hybrid
~~~~~~
There are five Dell EMC Software Suites sold with the VMAX Hybrid arrays: There are five Dell EMC Software Suites sold with the VMAX Hybrid arrays:
- Base Suite - Base Suite
@ -55,13 +96,11 @@ Suite and the Local Replication Suite) for the VMAX Hybrid.
Using PowerMax Remote Replication functionality will also require the Remote Using PowerMax Remote Replication functionality will also require the Remote
Replication Suite. Replication Suite.
For full functionality including SRDF for the VMAX All Flash, the FX package,
or the F package plus the SRDF ``a la carte`` add on is required.
The storage system also requires a Unisphere for PowerMax (SMC) eLicence. .. note::
Each are licensed separately. For further details on how to get the Each are licensed separately. For further details on how to get the
relevant license(s), reference eLicensing Support below. relevant license(s), reference eLicensing Support below.
eLicensing support eLicensing support
@ -129,16 +168,9 @@ PowerMax drivers also support the following features:
- Extending attached volume - Extending attached volume
- Replicated volume retype support - Replicated volume retype support
- Retyping attached(in-use) volume - Retyping attached(in-use) volume
- Unisphere high availability(HA) support - Unisphere High Availability(HA) support
- Online device expansion of a metro device - Online device expansion of a metro device
- Rapid tdev deallocation of deletes - Rapid TDEV deallocation of deletes
.. note::
VMAX All Flash array with Solutions Enabler 8.3.0.11 or later have
compression enabled by default when associated with Diamond Service Level.
This means volumes added to any newly created storage groups will be
compressed.
PowerMax naming conventions PowerMax naming conventions
@ -156,8 +188,8 @@ PowerMax naming conventions
1. Perform md5 hash on the shortHostName 1. Perform md5 hash on the shortHostName
2. Convert output of 1. to hex 2. Convert output of 1. to hex
3. Take last 6 characters of shortHostName and append output of 2. 3. Take last 6 characters of shortHostName and append output of 2.
4. If the length of output of 3. exceeds 16 characters 4. If the length of output of 3. exceeds 16 characters, join the
5. Add the first 8 characters and last 8 characters together first 8 characters and last 8 characters.
.. note:: .. note::
@ -171,8 +203,8 @@ PowerMax naming conventions
1. Perform md5 hash on the portgroup_name 1. Perform md5 hash on the portgroup_name
2. Convert output of 1. to hex 2. Convert output of 1. to hex
3. Take last 6 characters of portgroup_name and append output of 2. 3. Take last 6 characters of portgroup_name and append output of 2.
4. If the length of output of 3. exceeds 12 characters 4. If the length of output of 3. exceeds 12 characters, join the
5. Add the first 6 characters and last 6 characters together first 6 characters and last 6 characters.
Masking view names Masking view names
@ -180,7 +212,7 @@ Masking view names
Masking views are dynamically created by the PowerMax FC and iSCSI drivers Masking views are dynamically created by the PowerMax FC and iSCSI drivers
using the following naming conventions. ``[protocol]`` is either ``I`` for using the following naming conventions. ``[protocol]`` is either ``I`` for
volumes attached over iSCSI or ``F`` for volumes attached over Fiber Channel. volumes attached over iSCSI or ``F`` for volumes attached over Fibre Channel.
.. code-block:: text .. code-block:: text
@ -196,7 +228,7 @@ each new attach volume operation, the PowerMax driver retrieves the initiators
(either WWNNs or IQNs) from OpenStack and adds or updates the contents of the (either WWNNs or IQNs) from OpenStack and adds or updates the contents of the
Initiator Group as required. Names are of the following format. ``[protocol]`` Initiator Group as required. Names are of the following format. ``[protocol]``
is either ``I`` for volumes attached over iSCSI or ``F`` for volumes attached is either ``I`` for volumes attached over iSCSI or ``F`` for volumes attached
over Fiber Channel. over Fibre Channel.
.. code-block:: console .. code-block:: console
@ -245,15 +277,16 @@ Child storage groups:
.. note:: .. note::
CD and RE are only set if compression is explicitly disabled or replication CD and RE are only set if compression is explicitly disabled or replication
explicitly enabled. See the compression and replication sections below. explicitly enabled. See the compression `11. All Flash compression support`_
and replication `Volume replication support`_ sections below.
.. note:: .. note::
For PowerMax and any All Flash with PowerMax OS (5978) or greater, workload For PowerMax and any All Flash with PowerMax OS (5978) or greater, workload
is NONE if set will be ignored and set to NONE
PowerMax Driver Integration PowerMax driver integration
=========================== ===========================
1. Prerequisites 1. Prerequisites
@ -286,7 +319,7 @@ PowerMax Driver Integration
Configuration Guide`` at ``support.emc.com``. Configuration Guide`` at ``support.emc.com``.
2. FC Zoning with PowerMax 2. FC zoning with PowerMax
-------------------------- --------------------------
Zone Manager is required when there is a fabric between the host and array. Zone Manager is required when there is a fabric between the host and array.
@ -296,8 +329,8 @@ complex and open-zoning would raise security concerns.
3. iSCSI with PowerMax 3. iSCSI with PowerMax
---------------------- ----------------------
- Make sure the ``iscsi-initiator-utils`` package is installed on all Compute - Make sure the ``open-iscsi`` package (or distro equivalent) is installed
nodes. on all Compute nodes.
.. note:: .. note::
@ -305,15 +338,16 @@ complex and open-zoning would raise security concerns.
masking view. An attach operation creates this masking view. masking view. An attach operation creates this masking view.
4. Configure Block Storage in cinder.conf
4. Configure block storage in cinder.conf
----------------------------------------- -----------------------------------------
.. note:: .. note::
VMAX driver was rebranded to PowerMax in Stein, so some of the driver VMAX driver was rebranded to PowerMax in Stein, so some of the driver
specific tags have also changed. Legacy tags like vmax_srp, vmax_array, specific tags have also changed. Legacy tags like ``vmax_srp``,
vmax_service_level and vmax_port_group, as well as the old driver ``vmax_array``, ``vmax_service_level`` and ``vmax_port_group``, as well
location, will continue to work until the 'V' release. as the old driver location, will continue to work until the 'V' release.
.. config-table:: .. config-table::
@ -322,13 +356,6 @@ complex and open-zoning would raise security concerns.
cinder.volume.drivers.dell_emc.powermax.common cinder.volume.drivers.dell_emc.powermax.common
.. note::
For security and backend uniformity, the use of the XML file for PowerMax
backend configuration was deprecated in Queens and removed entirely
in Rocky.
.. note:: .. note::
``san_api_port`` is ``8443`` by default but can be changed if ``san_api_port`` is ``8443`` by default but can be changed if
@ -363,7 +390,7 @@ complex and open-zoning would raise security concerns.
+--------------------+----------------------------+---------+----------+ +--------------------+----------------------------+---------+----------+
Configure Block Storage in cinder.conf Configure block storage in cinder.conf
Add the following entries to ``/etc/cinder/cinder.conf``: Add the following entries to ``/etc/cinder/cinder.conf``:
@ -459,7 +486,7 @@ section describing unique parameters for connections, drivers and the
``cinder.conf`` backend stanza. ``cinder.conf`` backend stanza.
6. Create Volume Types 6. Create volume types
---------------------- ----------------------
Once the ``cinder.conf`` has been updated, :command:`openstack` commands Once the ``cinder.conf`` has been updated, :command:`openstack` commands
@ -515,15 +542,16 @@ associated with any service level).
.. note:: .. note::
PowerMax and Hybrid support Optimized, Diamond, Platinum, Gold, Silver, PowerMax and Hybrid support ``Optimized``, ``Diamond``, ``Platinum``,
Bronze, and NONE service levels. VMAX All Flash supports Diamond and ``Gold``, ``Silver``, ``Bronze``, and ``NONE`` service levels. VMAX
None. Hybrid and All Flash support DSS_REP, DSS, OLTP_REP, OLTP, and None All Flash supports ``Diamond`` and `None. Hybrid and All Flash support
workloads, the latter up until ucode 5977. Please refer to Stein PowerMax ``DSS_REP``, ``DSS``, ``OLTP_REP``, ``OLTP``, and None workloads, the
online documentation if you wish to use ``workload``. There is no support latter up until ucode 5977. Please refer to Stein PowerMax online
documentation if you wish to use ``workload``. There is no support
for workloads in PowerMax OS (5978) or greater. for workloads in PowerMax OS (5978) or greater.
7. Interval and Retries 7. Interval and retries
----------------------- -----------------------
By default, ``interval`` and ``retries`` are ``3`` seconds and ``200`` retries By default, ``interval`` and ``retries`` are ``3`` seconds and ``200`` retries
@ -554,32 +582,32 @@ Add the following lines to the PowerMax backend in the cinder.conf:
interval = 1 interval = 1
retries = 700 retries = 700
8. CHAP Authentication Support 8. CHAP authentication support
------------------------------ ------------------------------
This supports one way initiator CHAP authentication functionality into the This supports one-way initiator CHAP authentication functionality into the
PowerMax backend. With CHAP one-way authentication, the storage array PowerMax backend. With CHAP one-way authentication, the storage array
challenges the host during the initial link negotiation process and expects challenges the host during the initial link negotiation process and expects
to receive a valid credential and CHAP secret in response. When challenged, to receive a valid credential and CHAP secret in response. When challenged,
the host transmits a CHAP credential and CHAP secret to the storage array. the host transmits a CHAP credential and CHAP secret to the storage array.
The storagearray looks for this credential and CHAP secret which stored in The storage array looks for this credential and CHAP secret which stored in
the host initiator's initiator group (IG) information in the ACLX database. the host initiator's initiator group (IG) information in the ACLX database.
Once a positive authentication occurs, the storage array sends an acceptance Once a positive authentication occurs, the storage array sends an acceptance
message to the host. However, if the storage array fails to find any record message to the host. However, if the storage array fails to find any record
of the credential/secret pair, it sends a rejection message, and the link is of the credential/secret pair, it sends a rejection message, and the link is
closed. closed.
Assumptions, Restrictions and Pre-Requisites Assumptions, restrictions and prerequisites
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
#. The host initiator IQN is required along with the credentials the host #. The host initiator IQN is required along with the credentials the host
initiator will use to log into the storage array with. The same credentials initiator will use to log into the storage array with. The same credentials
should be used in a multi node system if connecting to the same array. should be used in a multi node system if connecting to the same array.
#. Enable one way CHAP authentication for the iscsi initiator on the storage #. Enable one-way CHAP authentication for the iSCSI initiator on the storage
array using SYMCLI. Template and example shown below. For the purpose of array using SYMCLI. Template and example shown below. For the purpose of
this setup, the credential/secret used would be my_username/my_password this setup, the credential/secret used would be my_username/my_password
with iscsi initiator of iqn.1991-05.com.company.lcseb130 with iSCSI initiator of iqn.1991-05.com.company.lcseb130
.. code-block:: console .. code-block:: console
@ -593,7 +621,7 @@ Assumptions, Restrictions and Pre-Requisites
Settings and Configuration Settings and configuration
~~~~~~~~~~~~~~~~~~~~~~~~~~ ~~~~~~~~~~~~~~~~~~~~~~~~~~
#. Set the configuration in the PowerMax backend group in cinder.conf using the #. Set the configuration in the PowerMax backend group in cinder.conf using the
@ -765,8 +793,8 @@ Prerequisites - PowerMax
Volume is created against volume type and QoS is enforced with the parameters Volume is created against volume type and QoS is enforced with the parameters
above. above.
USE CASE 2 - Preset limits USE CASE 2 - Pre-set limits
~~~~~~~~~~~~~~~~~~~~~~~~~~ ~~~~~~~~~~~~~~~~~~~~~~~~~~~
Prerequisites - PowerMax Prerequisites - PowerMax
@ -889,8 +917,8 @@ The output of the command contains the xml below. It is found between the
</iotune> </iotune>
USE CASE 3 - Preset limits USE CASE 3 - Pre-set limits
~~~~~~~~~~~~~~~~~~~~~~~~~~ ~~~~~~~~~~~~~~~~~~~~~~~~~~~
Prerequisites - PowerMax Prerequisites - PowerMax
@ -1145,7 +1173,10 @@ uncompressed.
.. note:: .. note::
This feature is only applicable for All Flash arrays, 250F, 450F, 850F This feature is only applicable for All Flash arrays, 250F, 450F, 850F
and 950F and PowerMax 2000 and 8000. and 950F and PowerMax 2000 and 8000. It was first introduced Solutions
Enabler 8.3.0.11 or later and is enabled by default when associated with
a Service Level. This means volumes added to any newly created storage
groups will be compressed.
Use case 1 - Compression disabled create, attach, detach, and delete volume Use case 1 - Compression disabled create, attach, detach, and delete volume
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
@ -1195,7 +1226,7 @@ Please refer to the following:
:doc:`/admin/blockstorage-over-subscription`. :doc:`/admin/blockstorage-over-subscription`.
13. Live Migration support 13. Live migration support
-------------------------- --------------------------
Non-live migration (sometimes referred to simply as 'migration'). The instance Non-live migration (sometimes referred to simply as 'migration'). The instance
@ -1222,7 +1253,7 @@ Architecture
In PowerMax, A volume cannot belong to two or more FAST storage groups at the In PowerMax, A volume cannot belong to two or more FAST storage groups at the
same time. To get around this limitation we leverage both cascaded storage same time. To get around this limitation we leverage both cascaded storage
groups and a temporary non FAST storage group. groups and a temporary non-FAST storage group.
A volume can remain 'live' if moved between masking views that have the same A volume can remain 'live' if moved between masking views that have the same
initiator group and port groups which preserves the host path. initiator group and port groups which preserves the host path.
@ -1236,7 +1267,7 @@ on the volume:
#. The volume is added to the FAST storage group within the destination #. The volume is added to the FAST storage group within the destination
parent storage group of the destination masking view. At this point the parent storage group of the destination masking view. At this point the
volume belongs to two storage groups. volume belongs to two storage groups.
#. One of two things happens: #. One of two things happen:
- If the connection to the destination instance is successful, the volume - If the connection to the destination instance is successful, the volume
is removed from the non-FAST storage group in the originating masking is removed from the non-FAST storage group in the originating masking
@ -1251,11 +1282,12 @@ Live migration configuration
Please refer to the following for more information: Please refer to the following for more information:
https://docs.openstack.org/nova/latest/admin/live-migration-usage.html https://docs.openstack.org/nova/latest/admin/configuring-migrations.html
and and
https://docs.openstack.org/nova/latest/admin/configuring-migrations.html https://docs.openstack.org/nova/latest/admin/live-migration-usage.html
.. note:: .. note::
@ -1326,7 +1358,7 @@ For our use case shown below, we have three hosts with host names HostA, HostB
and HostC. HostA is the compute node while HostB and HostC are the compute and HostC. HostA is the compute node while HostB and HostC are the compute
nodes. The following were also used in live migration. nodes. The following were also used in live migration.
- 2 gb bootable volume using the cirros image. - 2 gb bootable volume using the CirrOS image.
- Instance created using the 2gb volume above with a flavor m1.small using - Instance created using the 2gb volume above with a flavor m1.small using
2048 RAM, 20GB of Disk and 1 VCPU. 2048 RAM, 20GB of Disk and 1 VCPU.
@ -1390,7 +1422,7 @@ hosts/servers simultaneously. Please see
:doc:`/admin/blockstorage-volume-multiattach` :doc:`/admin/blockstorage-volume-multiattach`
for configuration information. for configuration information.
Multi-attach Architecture Multi-attach architecture
~~~~~~~~~~~~~~~~~~~~~~~~~ ~~~~~~~~~~~~~~~~~~~~~~~~~
In PowerMax, a volume cannot belong to two or more FAST storage groups at the In PowerMax, a volume cannot belong to two or more FAST storage groups at the
@ -1405,7 +1437,7 @@ no service level, workload, or SRP specified).
backend is required the volume is attached to and detached from each backend is required the volume is attached to and detached from each
host as normal. host as normal.
Example Use Case Example use case
~~~~~~~~~~~~~~~~ ~~~~~~~~~~~~~~~~
Volume ``Multi-attach-Vol-1`` (with a multi-attach capable volume type, and Volume ``Multi-attach-Vol-1`` (with a multi-attach capable volume type, and
@ -1435,21 +1467,22 @@ We then decide to detach the volume from Multi-attach-Instance-B on HostB:
storage group. The non-FAST managed storage group is cleaned up, storage group. The non-FAST managed storage group is cleaned up,
if required. if required.
.. note::
Known issue - the multi-attach flag is still false after a retype. This 15. Volume encryption support
is being addressed in https://bugs.launchpad.net/cinder/+bug/1790840
15. Volume Encryption support
----------------------------- -----------------------------
Please refer to the following: Please refer to the following:
:doc:`/configuration/block-storage/volume-encryption`. :doc:`/configuration/block-storage/volume-encryption`.
16. Volume metadata in logs 16. Volume metadata
--------------------------- -------------------
Volume metadata is returned to the user in both the Cinder Volume logs and
with volumes and snapshots created in Cinder via the UI or CLI.
16.1 Volume metadata in logs
~~~~~~~~~~~~~~~~~~~~~~~~~~~~
If debug is enabled in the default section of the cinder.conf, PowerMax Cinder If debug is enabled in the default section of the cinder.conf, PowerMax Cinder
driver will log additional volume information in the Cinder volume log, driver will log additional volume information in the Cinder volume log,
@ -1485,7 +1518,36 @@ PowerMax view point.
| serial_number | 000123456789 | | serial_number | 000123456789 |
+------------------------------------+---------------------------------------------------------+ +------------------------------------+---------------------------------------------------------+
17. Unisphere high availability(HA) support 16.2 Metadata in the UI and CLI
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
By default metadata will be set on all volume and snapshot objects created in
Cinder. This information represents the state of the object on the backend
PowerMax and will change when volume attributes are changed by performing
actions on them such as re-type or attaching to an instance.
.. code-block:: console
demo@openstack-controller:~$ cinder show powermax-volume
+--------------------------------+------------------------------------------------------------+
| Property | Value |
+--------------------------------+------------------------------------------------------------+
| metadata | ArrayID : 000123456789 |
| | ArrayModel : PowerMax_8000 |
| | CompressionDisabled : False |
| | Configuration : TDEV |
| | DeviceID : 0012F |
| | DeviceLabel : OS-d87edb98-60fd-49dd-bb0f-cc388cf6f3f4 |
| | Emulation : FBA |
| | ReplicationEnabled : False |
| | ServiceLevel : Diamond |
| | Workload : None |
| name | powermax-volume |
+--------------------------------+------------------------------------------------------------+
17. Unisphere High Availability(HA) support
------------------------------------------- -------------------------------------------
This feature facilitates high availability of Unisphere for PowerMax servers, This feature facilitates high availability of Unisphere for PowerMax servers,
@ -1564,7 +1626,7 @@ restarted for changes to take effect.
used by the PowerMax driver. used by the PowerMax driver.
18. Rapid TDEV Deallocation 18. Rapid TDEV deallocation
--------------------------- ---------------------------
The PowerMax driver can now leverage the enhanced volume delete feature-set The PowerMax driver can now leverage the enhanced volume delete feature-set
@ -1579,7 +1641,7 @@ compliant volume deletion sequence based on the connected PowerMax arrays
metadata. metadata.
19. PowerMax Online (in-use) Device Expansion 19. PowerMax online (in-use) device expansion
--------------------------------------------- ---------------------------------------------
.. table:: .. table::
@ -1589,27 +1651,27 @@ metadata.
+----------------+----------------+--------------+--------------+-------------+ +----------------+----------------+--------------+--------------+-------------+
| R1 uCode Level | R2 uCode Level | Sync | Async | Metro | | R1 uCode Level | R2 uCode Level | Sync | Async | Metro |
+================+================+==============+==============+=============+ +================+================+==============+==============+=============+
| 5979 | 5979 | Y | Y | Y | | 5978.444 | 5978.444 | Y | Y | Y |
+----------------+----------------+--------------+--------------+-------------+ +----------------+----------------+--------------+--------------+-------------+
| 5979 | 5978 | Y | Y | N | | 5978.444 | 5978.221 | Y | Y | N |
+----------------+----------------+--------------+--------------+-------------+ +----------------+----------------+--------------+--------------+-------------+
| 5978 | 5978 | Y | Y | N | | 5978.221 | 5978.221 | Y | Y | N |
+----------------+----------------+--------------+--------------+-------------+ +----------------+----------------+--------------+--------------+-------------+
Assumptions, Restrictions and Pre-Requisites Assumptions, restrictions and prerequisites
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
- ODE in the context of this document refers to extending a volume where it - ODE in the context of this document refers to extending a volume where it
is in-use, that is, attached to an instance. is in-use, that is, attached to an instance.
- The ``allow_extend`` is only applicable on Hybrid arrays or All Flash arrays - The ``allow_extend`` is only applicable on Hybrid arrays or All Flash arrays
with HyperMax OS. If included elsewhere, it is ignored. with HyperMax OS. If included elsewhere, it is ignored.
- Extending a Metro volume is blocked for all replication sessions where both - Extending a Metro volume is blocked for all replication sessions where both
R1 and R2 arrays are not PowerMax OS 5979 or newer. R1 and R2 arrays are not PowerMax OS 5978.444 or newer.
- Where one array is a lower uCode than the other, the environment is limited - Where one array is a lower uCode than the other, the environment is limited
to functionality of that of the lowest uCode level, i.e. if R1 is 5979 and to functionality of that of the lowest uCode level, i.e. if R1 is 5978.444
R2 is 5978, expanding a metro volume is not supported, both R1 and R2 need and R2 is 5978.221, expanding a metro volume is not supported, both R1 and
to be on 5979 uCode. R2 need to be on 5978.444 uCode.
Cinder supported operations Cinder supported operations
=========================== ===========================
@ -1690,7 +1752,7 @@ Configure the source and target arrays
* ``remote_port_group`` is the name of a PowerMax port group that has been * ``remote_port_group`` is the name of a PowerMax port group that has been
pre-configured to expose volumes managed by this backend in the event pre-configured to expose volumes managed by this backend in the event
of a failover. Make sure that this portgroup contains either all FC or of a failover. Make sure that this port group contains either all FC or
all iSCSI port groups (for a given back end), as appropriate for the all iSCSI port groups (for a given back end), as appropriate for the
configured driver (iSCSI or FC). configured driver (iSCSI or FC).
@ -1749,7 +1811,7 @@ Configure the source and target arrays
``replication_device`` parameter has been entered in the PowerMax ``replication_device`` parameter has been entered in the PowerMax
backend entry in the ``cinder.conf``, a corresponding volume type backend entry in the ``cinder.conf``, a corresponding volume type
needs to be created ``replication_enabled`` property set. See needs to be created ``replication_enabled`` property set. See
above ``Setup PowerMax drivers`` for details. above `6. Create volume types`_ for details.
.. code-block:: console .. code-block:: console
@ -1791,6 +1853,11 @@ Most features are supported, except for the following:
Failover host Failover host
~~~~~~~~~~~~~ ~~~~~~~~~~~~~
.. note::
Failover and Failback operations are not applicable in Metro
configurations.
In the event of a disaster, or where there is required downtime, upgrade In the event of a disaster, or where there is required downtime, upgrade
of the primary array for example, the administrator can issue the failover of the primary array for example, the administrator can issue the failover
host command to failover to the configured target: host command to failover to the configured target:
@ -1799,22 +1866,38 @@ host command to failover to the configured target:
# cinder failover-host cinder_host@POWERMAX_FC_REPLICATION # cinder failover-host cinder_host@POWERMAX_FC_REPLICATION
If the primary array becomes available again, you can initiate a failback After issuing Cinder failover-host command Cinder will set the R2 array as the
using the same command and specifying ``--backend_id default``: target array for Cinder, however to get existing instances to use this new
array and paths to volumes it is necessary to first shelve Nova instances and
then unshelve them, this will effectively restart the Nova instance and
re-establish data paths between Nova instances and the volumes on the R2 array.
.. code-block:: console
# nova shelve <server>
# nova unshelve [--availability-zone <availability_zone>] <server>
When a host is in failover mode performing normal volume or snapshot
provisioning will not be possible, failover-host mode simply provides access
to replicated volumes to minimise environment down-time. The primary objective
whilst in failover mode should be to get the R1 array back online. When the
primary array becomes available again, you can initiate a failback using the
same failover command and specifying --backend_id default:
.. code-block:: console .. code-block:: console
# cinder failover-host cinder_host@POWERMAX_FC_REPLICATION --backend_id default # cinder failover-host cinder_host@POWERMAX_FC_REPLICATION --backend_id default
.. note:: After issuing the failover command to revert to the default backend host it is
necessary to re-issue the Nova shelve and unshelve commands to restore the
data paths between Nova instances and their corresponding back end volumes.
Once reverted to the default backend volume and snapshot provisioning
operations can continue as normal.
Failover and Failback operations are not applicable in Metro configurations. Asynchronous and metro replication management groups
Asynchronous and Metro replication management groups
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Asynchronous and Metro volumes in an RDF session, i.e. belonging to an SRDF Asynchronous and metro volumes in an RDF session, i.e. belonging to an SRDF
group, must be managed together for RDF operations (although there is a group, must be managed together for RDF operations (although there is a
``consistency exempt`` option for creating and deleting pairs in an Async ``consistency exempt`` option for creating and deleting pairs in an Async
group). To facilitate this management, we create an internal RDF management group). To facilitate this management, we create an internal RDF management
@ -1827,7 +1910,7 @@ group. For this reason, it is imperative that the RDF group specified in the
Metro support Metro support
~~~~~~~~~~~~~ ~~~~~~~~~~~~~
SRDF/Metro is a High Availabilty solution. It works by masking both sides of SRDF/Metro is a high availability solution. It works by masking both sides of
the RDF relationship to the host, and presenting all paths to the host, the RDF relationship to the host, and presenting all paths to the host,
appearing that they all point to the one device. In order to do this, appearing that they all point to the one device. In order to do this,
there needs to be multipath software running to manage writing to the there needs to be multipath software running to manage writing to the
@ -1854,7 +1937,7 @@ Known issues
replication volume type. replication volume type.
Volume retype - storage assisted volume migration Volume retype - storage assisted volume migration
-------------------------------------------------- --------------------------------------------------
Volume retype with storage assisted migration is supported now for Volume retype with storage assisted migration is supported now for
@ -1866,7 +1949,7 @@ retype, follow these steps:
another, use volume retype with the migration-policy to on-demand. The another, use volume retype with the migration-policy to on-demand. The
target volume type should have the same volume_backend_name configured and target volume type should have the same volume_backend_name configured and
should have the desired pool_name to which you are trying to retype to should have the desired pool_name to which you are trying to retype to
(please refer to ``Setup PowerMax Drivers`` for details). (please refer to `6. Create volume types`_ for details).
.. code-block:: console .. code-block:: console
@ -1884,7 +1967,7 @@ retype, follow these steps:
.. note:: .. note::
With the Stein release, In Use (attached) volume retype is supported With the Stein release, in-use (attached) volume retype is supported
Generic volume group support Generic volume group support
@ -1944,7 +2027,7 @@ without failing over the entire host. See below for usage.
A generic volume group can be both consistent group snapshot enabled and A generic volume group can be both consistent group snapshot enabled and
consistent group replication enabled. consistent group replication enabled.
Storage Group Names Storage group names
~~~~~~~~~~~~~~~~~~~ ~~~~~~~~~~~~~~~~~~~
Storage groups are created on the PowerMax as a result of creation of generic Storage groups are created on the PowerMax as a result of creation of generic
@ -1956,113 +2039,22 @@ name.
TruncatedGroupName_GroupUUID or GroupUUID TruncatedGroupName_GroupUUID or GroupUUID
Group type operations Group type, group and group snapshot operations
~~~~~~~~~~~~~~~~~~~~~ ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
- Create a group type Please refer to the following section for the most up to date group type
group and group replication operations https://docs.openstack.org/cinder/latest/admin/blockstorage-groups.html
.. code-block:: console
cinder --os-volume-api-version 3.11 group-type-create GROUP_TYPE
- Show a group type
.. code-block:: console
cinder --os-volume-api-version 3.11 group-type-show GROUP_TYPE
- List group types
.. code-block:: console
cinder --os-volume-api-version 3.11 group-type-list
- Delete group type
.. code-block:: console
cinder --os-volume-api-version 3.11 group-type-delete GROUP_TYPE
- Set/unset a group spec
.. code-block:: console
cinder --os-volume-api-version 3.11 group-type-key GROUP_TYPE set consistent_group_snapshot_enabled="<is> True"
- List group types and group specs:
.. code-block:: console
cinder --os-volume-api-version 3.11 group-specs-list
Group operations
~~~~~~~~~~~~~~~~
- Create a group:
.. code-block:: console
cinder --os-volume-api-version 3.13 group-create --name GROUP GROUP_TYPE VOLUME_TYPE1,VOLUME_TYPE2
- Show a group:
.. code-block:: console
cinder --os-volume-api-version 3.13 group-show GROUP
- List all groups:
.. code-block:: console
cinder --os-volume-api-version 3.13 group-list
- Create a volume and add it to a group at the time of creation:
.. code-block:: console
cinder --os-volume-api-version 3.13 create --volume-type VOLUME_TYPE1 --group-id GROUP_ID 1
- Modify a group to add or remove volumes:
.. code-block:: console
cinder --os-volume-api-version 3.13 group-update --add-volumes UUID1,UUID2 --remove-volumes UUID3,UUID4 GROUP
- Delete a group
.. code-block:: console
cinder --os-volume-api-version 3.13 group-delete --delete-volumes GROUP
Group snapshot operations
~~~~~~~~~~~~~~~~~~~~~~~~~
- Create a group snapshot:
.. code-block:: console
cinder --os-volume-api-version 3.14 group-snapshot-create --name GROUP_SNAPSHOT GROUP
- Delete group snapshot(s):
.. code-block:: console
cinder --os-volume-api-version 3.14 group-snapshot-delete GROUP_SNAPSHOT
- Create a group from a group snapshot:
.. code-block:: console
$ cinder --os-volume-api-version 3.14 group-create-from-src --group-snapshot GROUP_SNAPSHOT --name GROUP
- Create a group from a source snapshot:
.. code-block:: console
$ cinder --os-volume-api-version 3.14 group-create-from-src --source-group SOURCE_GROUP --name GROUP
Group replication operations Group replication operations
~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Generic volume group operations no longer require the user to specify the
Cinder CLI version, however, performing generic volume group replication
operations still require this setting. When running generic volume group
commands set the value --os-volume-api-version to 3.38.
These commands are not listed in the latest Cinder CLI documentation so
will remain here until added to the latest Cinder CLI version or
deprecated from Cinder.
- Enable group replication - Enable group replication
@ -2090,7 +2082,7 @@ Group replication operations
--secondary-backend-id default --secondary-backend-id default
Manage and Unmanage Volumes Manage and unmanage Volumes
--------------------------- ---------------------------
Managing volumes in OpenStack is the process whereby a volume which exists Managing volumes in OpenStack is the process whereby a volume which exists
@ -2110,7 +2102,7 @@ OpenStack, the following prerequisites must be met:
- The volume must a whole GB e.g. 5.5GB is not a valid size - The volume must a whole GB e.g. 5.5GB is not a valid size
- The volume cannot be a snapvx target - The volume cannot be a SnapVX target
For a volume to exist in a Cinder managed pool, it must reside in the same For a volume to exist in a Cinder managed pool, it must reside in the same
@ -2137,7 +2129,7 @@ the same format:
- The PowerMax serial number (12 digit numerical) - The PowerMax serial number (12 digit numerical)
Manage Volumes Manage volumes
~~~~~~~~~~~~~~ ~~~~~~~~~~~~~~
With your pool name defined you can now manage the volume into OpenStack, this With your pool name defined you can now manage the volume into OpenStack, this
@ -2171,7 +2163,7 @@ the same way as any other OpenStack PowerMax volume.
PowerMax driver on a manage operation. PowerMax driver on a manage operation.
Managing Volumes with Replication Enabled Managing volumes with replication enabled
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Whilst it is not possible to manage volumes into OpenStack that are part of a Whilst it is not possible to manage volumes into OpenStack that are part of a
@ -2183,7 +2175,7 @@ volume type as the chosen volume type. Once managed, replication will be
enabled for that volume. enabled for that volume.
Unmanage Volume Unmanage volume
~~~~~~~~~~~~~~~ ~~~~~~~~~~~~~~~
Unmanaging a volume is not the same as deleting a volume. When a volume is Unmanaging a volume is not the same as deleting a volume. When a volume is
@ -2212,7 +2204,7 @@ the 'OS-' prefix has been removed, this is another visual indication that
the volume is no longer managed by OpenStack. the volume is no longer managed by OpenStack.
Manage/Unmanage Snapshots Manage/unmanage snapshots
------------------------- -------------------------
Users can manage PowerMax SnapVX snapshots into OpenStack if the source volume Users can manage PowerMax SnapVX snapshots into OpenStack if the source volume
@ -2231,7 +2223,7 @@ Set-up, restrictions and requirements:
#. It is only possible to manage or unmanage one snapshot at a time in Cinder. #. It is only possible to manage or unmanage one snapshot at a time in Cinder.
Manage SnapVX Snapshot Manage SnapVX snapshot
~~~~~~~~~~~~~~~~~~~~~~ ~~~~~~~~~~~~~~~~~~~~~~
It is possible to manage PowerMax SnapVX snapshots into OpenStack, where the It is possible to manage PowerMax SnapVX snapshots into OpenStack, where the
@ -2247,7 +2239,7 @@ the restriction around managing SnapVX source volumes has been removed.
or volumes which exist in a replication session. or volumes which exist in a replication session.
Requirements/Restrictions: Requirements/restrictions:
#. The SnapVX source volume must be present in and managed by Cinder. #. The SnapVX source volume must be present in and managed by Cinder.
@ -2259,7 +2251,7 @@ Requirements/Restrictions:
linked target volumes. linked target volumes.
Command Structure: Command structure:
#. Identify your SnapVX snapshot for management on the PowerMax, note the name. #. Identify your SnapVX snapshot for management on the PowerMax, note the name.
@ -2321,7 +2313,7 @@ snapshot in this example named ``OS-PowerMaxSnapshot``. The associated snapshot
managed by Cinder will be present for use under the name ``SnapshotManaged``. managed by Cinder will be present for use under the name ``SnapshotManaged``.
Unmanage Cinder Snapshot Unmanage cinder snapshot
~~~~~~~~~~~~~~~~~~~~~~~~ ~~~~~~~~~~~~~~~~~~~~~~~~
Unmanaging a snapshot in Cinder is the process whereby the snapshot is removed Unmanaging a snapshot in Cinder is the process whereby the snapshot is removed
@ -2386,7 +2378,7 @@ List manageable volume is filtered by:
- Volume should not be ``encapsulated`` - Volume should not be ``encapsulated``
- Volume should not be ``reserved`` - Volume should not be ``reserved``
- Volume should not be a part of an RDF session - Volume should not be a part of an RDF session
- Volume should not be a snapVX Target - Volume should not be a SnapVX Target
- Volume identifier should not begin with ``OS-``. - Volume identifier should not begin with ``OS-``.
Manageable snaphots Manageable snaphots
@ -2411,7 +2403,7 @@ List manageable snapshots is filtered by:
There is some delay in the syncing of the Unisphere for PowerMax database There is some delay in the syncing of the Unisphere for PowerMax database
when the state/properties of a volume is modified using ``symcli``. To when the state/properties of a volume is modified using ``symcli``. To
prevent this it is preferrable to modify state/properties of volumes within prevent this it is preferable to modify state/properties of volumes within
Unisphere. Unisphere.
@ -2430,10 +2422,17 @@ Upgrading from SMI-S based driver to RESTAPI based driver
Seamless upgrades from an SMI-S based driver to RESTAPI based driver, Seamless upgrades from an SMI-S based driver to RESTAPI based driver,
following the setup instructions above, are supported with a few exceptions: following the setup instructions above, are supported with a few exceptions:
#. Live migration functionality will not work on already attached/in-use #. OpenStack's ``live migration`` functionality will not work on already
legacy volumes. These volumes will first need to be detached and reattached attached/in-use legacy volumes without first migrating the volumes to
using the RESTAPI based driver. This is because we have changed the masking the new REST masking view structure. This can be done by running the
view architecture from Pike to better support this functionality. migrate.py script in PyU4V. Please refer to the Tools Guide in PyU4V_.
.. code-block:: text
$ pip install PyU4V
#. Consistency groups are deprecated in Pike. Generic Volume Groups are #. Consistency groups are deprecated in Pike. Generic Volume Groups are
supported from Pike onwards. supported from Pike onwards.
.. _PyU4V: https://pyu4v.readthedocs.io/en/latest/