PowerMax Docs - Wallaby documentation

Updating version, multipathing, Unisphere failover and
Manageable volumes sections.

Change-Id: I67108dd63efffa83637731ac2dab49768f12e6ae
This commit is contained in:
Helen Walsh 2021-04-06 16:08:25 +01:00
parent 393c2e4ad9
commit fd6ce63065
1 changed files with 117 additions and 26 deletions

View File

@ -28,25 +28,33 @@ System requirements and licensing
The Dell EMC PowerMax Cinder driver supports the VMAX-3 hybrid series, VMAX
All-Flash series and the PowerMax arrays.
The array operating system software, Solutions Enabler 9.2.x series, and
Unisphere for PowerMax 9.2.x series are required to run Dell EMC PowerMax
Cinder driver.
The array operating system software, Solutions Enabler 9.2.1 series, and
Unisphere for PowerMax 9.2.1 series are required to run Dell EMC PowerMax
Cinder driver for the Wallaby release. Please refer to support-matrix-table_
for the support matrix of previous OpenStack versions.
Download Solutions Enabler and Unisphere from the Dell EMC's support web site
(login is required). See the ``Dell EMC Solutions Enabler 9.2.x Installation
and Configuration Guide`` and ``Dell EMC Unisphere for PowerMax Installation
Guide`` at the `Dell EMC Support`_ site.
(login is required). See the `Dell EMC Solutions Enabler 9.2.1 Installation
and Configuration Guide` and `Dell EMC Unisphere for PowerMax Installation
Guide` at the `Dell EMC Support`_ site.
.. note::
While it is not explicitly documented which OS versions should be
installed on a particular array, it is recommended to install the latest
PowerMax OS as supported by Unisphere for PowerMax, that the PowerMax
driver supports for a given OpenStack release.
At the time each OpenStack release, support-matrix-table_ was the
recommended PowerMax management software and OS combinations. Please
reach out your local PowerMax representative to see if these versions
are still valid.
.. _support-matrix-table:
.. table:: PowerMax Management software and OS for OpenStack release
+-----------+------------------------+-------------+
| OpenStack | Unisphere for PowerMax | PowerMax OS |
+===========+========================+=============+
| Wallaby | 9.2.1 | 5978.711 |
+-----------+------------------------+-------------+
| Victoria | 9.2.x | 5978.669 |
+-----------+------------------------+-------------+
| Ussuri | 9.1.x | 5978.479 |
@ -56,11 +64,21 @@ Guide`` at the `Dell EMC Support`_ site.
| Stein | 9.0.x | 5978.221 |
+-----------+------------------------+-------------+
However, a Hybrid array can only run HyperMax OS 5977, and is still
supported until further notice. Some functionality will not be available
in older versions of the OS. If in any doubt, please contact your customer
.. note::
A Hybrid array can only run HyperMax OS 5977, and is still supported until
further notice. Some functionality will not be available in older versions
of the OS. If in any doubt, please contact your local PowerMax
representative.
.. note::
Newer versions of Unisphere for PowerMax and PowerMax OS are not
retrospectively tested on older versions of OpenStack. If it is necessary
to upgrade, the older REST endpoints will be used. For example, in Ussuri,
if upgrading to Unisphere for PowerMax 9.2, the older ``91`` endpoints will
be used.
Required PowerMax software suites for OpenStack
@ -321,6 +339,22 @@ Child storage groups:
For VMAX All Flash with PowerMax OS (5978) or greater, workload if set will
be ignored and set to NONE.
.. _my-table:
.. table:: Replication storage group naming conventions
+----------------------------+---------------------------------+--------------------------------+--------------------+
| Default storage group | Attached child storage group | Management Group | Replication Type |
+============================+=================================+================================+====================+
| OS-[SRP]-[SL]-[WL]-SG | OS-[HOST]-[SRP]-[SL/WL]-[PG] | N/A | None |
+----------------------------+---------------------------------+--------------------------------+--------------------+
| OS-[SRP]-[SL]-[WL]-RE-SG | OS-[HOST]-[SRP]-[SL/WL]-[PG]-RE | N/A | Synchronous |
+----------------------------+---------------------------------+--------------------------------+--------------------+
| OS-[SRP]-[SL]-[WL]-RA-SG | OS-[HOST]-[SRP]-[SL/WL]-[PG]-RA | OS-[RDFG]-Asynchronous-rdf-sg | Asynchronous |
+----------------------------+---------------------------------+--------------------------------+--------------------+
| OS-[SRP]-[SL]-[WL]-RM-SG | OS-[HOST]-[SRP]-[SL/WL]-[PG]-RM | OS-[RDFG]-Metro-rdf-sg | Metro |
+----------------------------+---------------------------------+--------------------------------+--------------------+
PowerMax driver integration
===========================
@ -336,13 +370,13 @@ PowerMax driver integration
Appliance (a VMware ESX server VM). Additionally, starting with HYPERMAX
OS Q3 2015, you can manage VMAX3 arrays using the Embedded Management
(eManagement) container application. See the ``Dell EMC Solutions Enabler
9.2.x Installation and Configuration Guide`` on `Dell EMC Support`_ for
9.2.1 Installation and Configuration Guide`` on `Dell EMC Support`_ for
more details.
.. note::
You must discover storage arrays before you can use the PowerMax drivers.
Follow instructions in ``Dell EMC Solutions Enabler 9.2.x Installation
Follow instructions in ``Dell EMC Solutions Enabler 9.2.1 Installation
and Configuration Guide`` on `Dell EMC Support`_ for more details.
#. Download Unisphere from `Dell EMC Support`_ and install it.
@ -351,7 +385,7 @@ PowerMax driver integration
- i.e., on the same server running Solutions Enabler; on a server
connected to the Solutions Enabler server; or using the eManagement
container application (containing Solutions Enabler and Unisphere for
PowerMax). See ``Dell EMC Solutions Enabler 9.2.x Installation and
PowerMax). See ``Dell EMC Solutions Enabler 9.2.1 Installation and
Configuration Guide`` at `Dell EMC Support`_.
@ -1051,10 +1085,10 @@ Prerequisites - PowerMax
Volume is created against volume type and there is no QoS change.
10. iSCSI multi-pathing support
-------------------------------
10. Multi-pathing support
-------------------------
- Install ``open-iscsi`` on all nodes on your system
- Install ``open-iscsi`` on all nodes on your system if on an iSCSI setup.
- Do not install EMC PowerPath as they cannot co-exist with native multi-path
software
- Multi-path tools must be installed on all Nova compute nodes
@ -1115,21 +1149,37 @@ performance. Log in as a privileged user and make the following changes to
You may need to reboot the host after installing the MPIO tools or restart
iSCSI and multi-path services.
On Ubuntu:
On Ubuntu iSCSI:
.. code-block:: console
# service open-iscsi restart
# service multipath-tools restart
On Ubuntu FC
.. code-block:: console
# service multipath-tools restart
On openSUSE, SUSE Linux Enterprise Server, Red Hat Enterprise Linux, and
CentOS:
CentOS iSCSI:
.. code-block:: console
# systemctl restart open-iscsi
# systemctl restart multipath-tools
On openSUSE, SUSE Linux Enterprise Server, Red Hat Enterprise Linux, and
CentOS FC:
.. code-block:: console
# systemctl restart multipath-tools
.. code-block:: console
$ lsblk
@ -1622,12 +1672,16 @@ Requirements
Configuration
~~~~~~~~~~~~~
The following configuration changes need to be made in ``cinder.conf`` in order
to support the failover to secondary Unisphere. Cinder services will need to
be restarted for changes to take effect.
The following configuration changes need to be made in ``cinder.conf`` under
the PowerMax backend stanza in order to support the failover to secondary
Unisphere. Cinder services will need to be restarted for changes to take
effect.
.. code-block:: console
[POWERMAX_1]
...
u4p_failover_timeout = 30
u4p_failover_retries = 3
u4p_failover_backoff_factor = 1
@ -1684,6 +1738,14 @@ metadata.
+----------------+----------------+--------------+--------------+-------------+
| R1 uCode Level | R2 uCode Level | Sync | Async | Metro |
+================+================+==============+==============+=============+
| 5978.711 | 5978.711 | Y | Y | Y |
+----------------+----------------+--------------+--------------+-------------+
| 5978.711 | 5978.669 | Y | Y | Y |
+----------------+----------------+--------------+--------------+-------------+
| 5978.711 | 5978.444 | Y | Y | Y |
+----------------+----------------+--------------+--------------+-------------+
| 5978.711 | 5978.221 | Y | Y | N |
+----------------+----------------+--------------+--------------+-------------+
| 5978.669 | 5978.669 | Y | Y | Y |
+----------------+----------------+--------------+--------------+-------------+
| 5978.669 | 5978.444 | Y | Y | Y |
@ -1897,6 +1959,33 @@ Cinder supported operations
Volume replication support
--------------------------
.. note::
A mix of ``RDF1+TDEV`` and ``TDEV`` volumes should not exist in the same
storage group. This can happen on a cleanup operation after breaking the
pair and a 'TDEV' remains in the storage group on either the local or
remote array. If this happens, remove the volume from the storage
group so that further replicated volume operations can continue.
For example, Remove ``TDEV`` from ``OS-[SRP]-[SL]-[WL]-RA-SG``.
.. note::
Replication storage groups should exist on both local and remote array but
never on just one. For example, if OS-[SRP]-[SL]-[WL]-RA-SG exists on
local array A it must also exist on remote array B. If this condition
does not hold, further replication operations will fail. This applies
to management storage groups in the case of ``Asynchronous`` and ``Metro``
modes also. See :ref:`my-table`.
.. note::
The number of devices in replication storage groups in both local and
remote arrays should be same. This also applies to management storage
groups in ``Asynchronous`` and ``Metro`` modes. See :ref:`my-table`.
Configure a single replication target
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
@ -2034,7 +2123,7 @@ Configure a single replication target
``replication_device`` parameter has been entered in the PowerMax
backend entry in the ``cinder.conf``, a corresponding volume type
needs to be created ``replication_enabled`` property set. See
above `6. Create volume types`_ for details.
above `Create volume types`_ for details.
.. code-block:: console
@ -2497,7 +2586,7 @@ retype, follow these steps:
another, use volume retype with the migration-policy to on-demand. The
target volume type should have the same volume_backend_name configured and
should have the desired pool_name to which you are trying to retype to
(please refer to `6. Create volume types`_ for details).
(please refer to `Create volume types`_ for details).
.. code-block:: console
@ -2919,6 +3008,7 @@ List manageable volume is filtered by:
- Volume should not be a part of an RDF session
- Volume should not be a SnapVX Target
- Volume identifier should not begin with ``OS-``.
- Volume should not be in more than one storage group.
Manageable snaphots
~~~~~~~~~~~~~~~~~~~
@ -3146,3 +3236,4 @@ following the setup instructions above, are supported with a few exceptions:
.. _volume backup: https://docs.openstack.org/cinder/latest/configuration/block-storage/backup-drivers.html
.. _volume backup CLI: https://docs.openstack.org/python-openstackclient/latest/cli/command-objects/volume-backup.html
.. _PyU4V: https://pyu4v.readthedocs.io/en/latest/
.. _Create volume types: `6. Create volume types`_