rolling upgrades
Change-Id: Ie036ba4da5ec146ff8f5bb37766f9314718d823c Implements: blueprint rolling-upgrades
This commit is contained in:
parent
628ac86f48
commit
cad5afb18e
@ -25,4 +25,5 @@
|
||||
dbreco
|
||||
development
|
||||
manual
|
||||
upgrade
|
||||
mod_wsgi
|
||||
|
114
doc/source/install/upgrade.rst
Normal file
114
doc/source/install/upgrade.rst
Normal file
@ -0,0 +1,114 @@
|
||||
..
|
||||
Licensed under the Apache License, Version 2.0 (the "License"); you may
|
||||
not use this file except in compliance with the License. You may obtain
|
||||
a copy of the License at
|
||||
|
||||
http://www.apache.org/licenses/LICENSE-2.0
|
||||
|
||||
Unless required by applicable law or agreed to in writing, software
|
||||
distributed under the License is distributed on an "AS IS" BASIS, WITHOUT
|
||||
WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. See the
|
||||
License for the specific language governing permissions and limitations
|
||||
under the License.
|
||||
|
||||
.. _upgrade:
|
||||
|
||||
==========
|
||||
Upgrading
|
||||
==========
|
||||
|
||||
Ceilometer's services support both full upgrades as well as partial
|
||||
(rolling) upgrades. The required steps for each process are described below.
|
||||
|
||||
|
||||
Full upgrades
|
||||
=============
|
||||
|
||||
The following describes how to upgrade your entire Ceilometer environment in
|
||||
one pass.
|
||||
|
||||
.. _full upgrade path:
|
||||
|
||||
1. Upgrade the database (if applicable)
|
||||
|
||||
Run ceilometer-dbsync to upgrade the database if using one of Ceilometer's
|
||||
databases (see :ref:`choosing_db_backend`). The database does not need to be
|
||||
taken offline as no data is modified or deleted. Ideally this should be done
|
||||
during a period of low activity. Best practices should still be followed
|
||||
(ie. back up your data). If not using a Ceilometer database, you should
|
||||
consult the documentation of that storage beforehand.
|
||||
|
||||
2. Upgrade the collector service(s)
|
||||
|
||||
Shutdown all collector services. The new collector, that knows how to
|
||||
interpret the new payload, can then be started. It will disregard any
|
||||
historical attributes and can continue to process older data from the
|
||||
agents. You may restart as many new collectors as required.
|
||||
|
||||
3. Upgrade the notification agent(s)
|
||||
|
||||
The notification agent can then be taken offline and upgraded with the
|
||||
same conditions as the collector service.
|
||||
|
||||
4. Upgrade the polling agent(s)
|
||||
|
||||
In this path, you'll want to take down agents on all hosts before starting.
|
||||
After starting the first agent, you should verify that data is again being
|
||||
polled. Additional agents can be added to support coordination if enabled.
|
||||
|
||||
.. note::
|
||||
|
||||
The API service can be taken offline and upgraded at any point in the
|
||||
process (if applicable).
|
||||
|
||||
|
||||
Partial upgrades
|
||||
================
|
||||
|
||||
The following describes how to upgrade parts of your Ceilometer environment
|
||||
gradually. The ultimate goal is to have all services upgraded to the new
|
||||
version in time.
|
||||
|
||||
1. Upgrade the database (if applicable)
|
||||
|
||||
Upgrading the database here is the same as the `full upgrade path`_.
|
||||
|
||||
2. Upgrade the collector service(s)
|
||||
|
||||
The new collector services can be started alongside the old collectors.
|
||||
Collectors old and new will disregard any new or historical attributes.
|
||||
|
||||
3. Upgrade the notification agent(s)
|
||||
|
||||
The new notification agent can be started alongside the old agent if no
|
||||
workload_partioning is enabled OR if it has the same pipeline configuration.
|
||||
If the pipeline configuration is changed, the old agents must be loaded with
|
||||
the same pipeline configuration first to ensure the notification agents all
|
||||
work against same pipeline sets.
|
||||
|
||||
4. Upgrade the polling agent(s)
|
||||
|
||||
The new polling agent can be started alongside the old agent only if no new
|
||||
pollsters were added. If not, new polling agents must start only in it's
|
||||
own partitioning group and poll only the new pollsters. After all old agents
|
||||
are upgraded, the polling agents can be changed to poll both new pollsters
|
||||
AND the old ones.
|
||||
|
||||
5. Upgrade the API service(s)
|
||||
|
||||
API management is handled by WSGI so there is only ever one version of API
|
||||
service running
|
||||
|
||||
.. note::
|
||||
|
||||
Upgrade ordering does not matter in partial upgrade path. The only
|
||||
requirement is that the database be upgraded first. It is advisable to
|
||||
upgrade following the same ordering as currently described: database,
|
||||
collector, notification agent, polling agent, api.
|
||||
|
||||
|
||||
Developer notes
|
||||
===============
|
||||
|
||||
When updating data models in the database or IPC, we need to adhere to a single
|
||||
mantra: 'always add, never delete or modify.'
|