Fix snmp pollster to not ignore valid meters

Change-Id: Iecffab082f384df6c2fdb5f29754f674c9184b67
Closes-Bug: #1503189
This commit is contained in:
Pradeep Kilambi 2015-10-13 11:35:17 -04:00
parent decebfd9f1
commit dc30bca3fb
2 changed files with 27 additions and 2 deletions

View File

@ -258,6 +258,11 @@ def setup_meters_config():
def load_definition(config_def):
mappings = {}
for meter_def in config_def.get('metric', []):
meter = MeterDefinition(meter_def)
mappings[meter.name] = meter
try:
meter = MeterDefinition(meter_def)
mappings[meter.name] = meter
except MeterDefinitionException as me:
errmsg = (_LE("Error loading meter definition : %(err)s")
% dict(err=me.message))
LOG.error(errmsg)
return mappings

View File

@ -65,6 +65,26 @@ class TestMeterDefinition(test_base.BaseTestCase):
except generic.MeterDefinitionException as e:
self.assertEqual("Unrecognized type value invalid", e.message)
@mock.patch('ceilometer.hardware.pollsters.generic.LOG')
def test_bad_metric_skip(self, LOG):
cfg = {'metric': [dict(name='test1',
type='gauge',
unit='B',
snmp_inspector={}),
dict(name='test_bad',
type='invalid',
unit='B',
snmp_inspector={}),
dict(name='test2',
type='gauge',
unit='B',
snmp_inspector={})]}
data = generic.load_definition(cfg)
self.assertEqual(2, len(data))
LOG.error.assert_called_with(
"Error loading meter definition : "
"Unrecognized type value invalid")
class FakeInspector(inspector_base.Inspector):
net_metadata = dict(name='test.teest',