deb-ceilometer/ceilometer/notification.py

268 lines
11 KiB
Python

#
# Copyright 2012-2013 eNovance <licensing@enovance.com>
#
# Licensed under the Apache License, Version 2.0 (the "License"); you may
# not use this file except in compliance with the License. You may obtain
# a copy of the License at
#
# http://www.apache.org/licenses/LICENSE-2.0
#
# Unless required by applicable law or agreed to in writing, software
# distributed under the License is distributed on an "AS IS" BASIS, WITHOUT
# WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. See the
# License for the specific language governing permissions and limitations
# under the License.
from oslo_config import cfg
from oslo_context import context
from oslo_log import log
import oslo_messaging
from stevedore import extension
from ceilometer.agent import plugin_base as base
from ceilometer import coordination
from ceilometer.event import endpoint as event_endpoint
from ceilometer.i18n import _, _LI, _LW
from ceilometer import messaging
from ceilometer import pipeline
from ceilometer import service_base
from ceilometer import utils
LOG = log.getLogger(__name__)
OPTS = [
cfg.BoolOpt('ack_on_event_error',
default=True,
deprecated_group='collector',
help='Acknowledge message when event persistence fails.'),
cfg.BoolOpt('store_events',
deprecated_group='collector',
default=False,
help='Save event details.'),
cfg.BoolOpt('disable_non_metric_meters',
default=True,
help='WARNING: Ceilometer historically offered the ability to '
'store events as meters. This usage is NOT advised as it '
'can flood the metering database and cause performance '
'degradation.'),
cfg.BoolOpt('workload_partitioning',
default=False,
help='Enable workload partitioning, allowing multiple '
'notification agents to be run simultaneously.'),
cfg.MultiStrOpt('messaging_urls',
default=[],
help="Messaging URLs to listen for notifications. "
"Example: transport://user:pass@host1:port"
"[,hostN:portN]/virtual_host "
"(DEFAULT/transport_url is used if empty)"),
]
cfg.CONF.register_opts(OPTS, group="notification")
cfg.CONF.import_opt('telemetry_driver', 'ceilometer.publisher.messaging',
group='publisher_notifier')
class NotificationService(service_base.BaseService):
"""Notification service.
When running multiple agents, additional queuing sequence is required for
inter process communication. Each agent has two listeners: one to listen
to the main OpenStack queue and another listener(and notifier) for IPC to
divide pipeline sink endpoints. Coordination should be enabled to have
proper active/active HA.
"""
NOTIFICATION_NAMESPACE = 'ceilometer.notification'
NOTIFICATION_IPC = 'ceilometer-pipe'
def __init__(self, *args, **kwargs):
super(NotificationService, self).__init__(*args, **kwargs)
self.partition_coordinator = None
self.listeners, self.pipeline_listeners = [], []
self.group_id = None
@classmethod
def _get_notifications_manager(cls, pm):
return extension.ExtensionManager(
namespace=cls.NOTIFICATION_NAMESPACE,
invoke_on_load=True,
invoke_args=(pm, )
)
def _get_notifier(self, transport, pipe):
return oslo_messaging.Notifier(
transport,
driver=cfg.CONF.publisher_notifier.telemetry_driver,
publisher_id='ceilometer.notification',
topic='%s-%s' % (self.NOTIFICATION_IPC, pipe.name))
def _get_pipe_manager(self, transport, pipeline_manager):
if cfg.CONF.notification.workload_partitioning:
pipe_manager = pipeline.SamplePipelineTransportManager()
for pipe in pipeline_manager.pipelines:
pipe_manager.add_transporter(
(pipe.source.support_meter,
self._get_notifier(transport, pipe)))
else:
pipe_manager = pipeline_manager
return pipe_manager
def _get_event_pipeline_manager(self, transport):
if cfg.CONF.notification.store_events:
self.event_pipeline_manager = pipeline.setup_event_pipeline()
if cfg.CONF.notification.workload_partitioning:
event_pipe_manager = pipeline.EventPipelineTransportManager()
for pipe in self.event_pipeline_manager.pipelines:
event_pipe_manager.add_transporter(
(pipe.source.support_event,
self._get_notifier(transport, pipe)))
else:
event_pipe_manager = self.event_pipeline_manager
return event_pipe_manager
def start(self):
super(NotificationService, self).start()
self.pipeline_manager = pipeline.setup_pipeline()
self.transport = messaging.get_transport()
self.pipe_manager = self._get_pipe_manager(self.transport,
self.pipeline_manager)
self.event_pipe_manager = self._get_event_pipeline_manager(
self.transport)
self.partition_coordinator = coordination.PartitionCoordinator()
self.partition_coordinator.start()
if cfg.CONF.notification.workload_partitioning:
self.ctxt = context.get_admin_context()
self.group_id = self.NOTIFICATION_NAMESPACE
else:
# FIXME(sileht): endpoint use notification_topics option
# and it should not because this is oslo_messaging option
# not a ceilometer, until we have a something to get
# the notification_topics in an other way
# we must create a transport to ensure the option have
# beeen registered by oslo_messaging
messaging.get_notifier(self.transport, '')
self.group_id = None
self.listeners, self.pipeline_listeners = [], []
self._configure_main_queue_listeners(self.pipe_manager,
self.event_pipe_manager)
if cfg.CONF.notification.workload_partitioning:
self.partition_coordinator.join_group(self.group_id)
self._configure_pipeline_listeners()
self.partition_coordinator.watch_group(self.group_id,
self._refresh_agent)
self.tg.add_timer(cfg.CONF.coordination.heartbeat,
self.partition_coordinator.heartbeat)
self.tg.add_timer(cfg.CONF.coordination.check_watchers,
self.partition_coordinator.run_watchers)
if not cfg.CONF.notification.disable_non_metric_meters:
LOG.warning(_LW('Non-metric meters may be collected. It is highly '
'advisable to disable these meters using '
'ceilometer.conf or the pipeline.yaml'))
# Add a dummy thread to have wait() working
self.tg.add_timer(604800, lambda: None)
self.init_pipeline_refresh()
def _configure_main_queue_listeners(self, pipe_manager,
event_pipe_manager):
notification_manager = self._get_notifications_manager(pipe_manager)
if not list(notification_manager):
LOG.warning(_('Failed to load any notification handlers for %s'),
self.NOTIFICATION_NAMESPACE)
ack_on_error = cfg.CONF.notification.ack_on_event_error
endpoints = []
if cfg.CONF.notification.store_events:
endpoints.append(
event_endpoint.EventsNotificationEndpoint(event_pipe_manager))
targets = []
for ext in notification_manager:
handler = ext.obj
if (cfg.CONF.notification.disable_non_metric_meters and
isinstance(handler, base.NonMetricNotificationBase)):
continue
LOG.debug(_('Event types from %(name)s: %(type)s'
' (ack_on_error=%(error)s)') %
{'name': ext.name,
'type': ', '.join(handler.event_types),
'error': ack_on_error})
# NOTE(gordc): this could be a set check but oslo_messaging issue
# https://bugs.launchpad.net/oslo.messaging/+bug/1398511
# This ensures we don't create multiple duplicate consumers.
for new_tar in handler.get_targets(cfg.CONF):
if new_tar not in targets:
targets.append(new_tar)
endpoints.append(handler)
urls = cfg.CONF.notification.messaging_urls or [None]
for url in urls:
transport = messaging.get_transport(url)
listener = messaging.get_notification_listener(
transport, targets, endpoints)
listener.start()
self.listeners.append(listener)
def _refresh_agent(self, event):
utils.kill_listeners(self.pipeline_listeners)
self._configure_pipeline_listeners()
def _configure_pipeline_listeners(self):
self.pipeline_listeners = []
ev_pipes = []
if cfg.CONF.notification.store_events:
ev_pipes = self.event_pipeline_manager.pipelines
partitioned = self.partition_coordinator.extract_my_subset(
self.group_id, self.pipeline_manager.pipelines + ev_pipes)
transport = messaging.get_transport()
for pipe in partitioned:
LOG.debug(_('Pipeline endpoint: %s'), pipe.name)
pipe_endpoint = (pipeline.EventPipelineEndpoint
if isinstance(pipe, pipeline.EventPipeline) else
pipeline.SamplePipelineEndpoint)
listener = messaging.get_notification_listener(
transport,
[oslo_messaging.Target(
topic='%s-%s' % (self.NOTIFICATION_IPC, pipe.name))],
[pipe_endpoint(self.ctxt, pipe)])
listener.start()
self.pipeline_listeners.append(listener)
def stop(self):
if self.partition_coordinator:
self.partition_coordinator.stop()
utils.kill_listeners(self.listeners + self.pipeline_listeners)
super(NotificationService, self).stop()
def reload_pipeline(self):
LOG.info(_LI("Reloading notification agent and listeners."))
self.pipe_manager = self._get_pipe_manager(
self.transport, self.pipeline_manager)
# re-start the main queue listeners.
utils.kill_listeners(self.listeners)
self._configure_main_queue_listeners(
self.pipe_manager, self.event_pipe_manager)
# re-start the pipeline listeners if workload partitioning
# is enabled.
if cfg.CONF.notification.workload_partitioning:
self._refresh_agent(None)