deb-ceilometer/ceilometer/notification.py
gordon chung ed5f80aeba do not recreate main queue listeners on partitioning
when we have workload partitioning enabled, we kill and recreate
the main queue listeners whenever an agent is added or dropped.
this isn't necessary and also adds significant overhead to
rebalancing logic. this patch changes it to just reconfigure
pipeline queues.

Change-Id: I81953239f2dd1fa610762f01a7a17653242db53e
Closes-Bug: #1496442
2015-09-16 11:39:54 -04:00

290 lines
12 KiB
Python

#
# Copyright 2012-2013 eNovance <licensing@enovance.com>
#
# Licensed under the Apache License, Version 2.0 (the "License"); you may
# not use this file except in compliance with the License. You may obtain
# a copy of the License at
#
# http://www.apache.org/licenses/LICENSE-2.0
#
# Unless required by applicable law or agreed to in writing, software
# distributed under the License is distributed on an "AS IS" BASIS, WITHOUT
# WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. See the
# License for the specific language governing permissions and limitations
# under the License.
from oslo_config import cfg
from oslo_context import context
from oslo_log import log
import oslo_messaging
from stevedore import extension
from ceilometer.agent import plugin_base as base
from ceilometer import coordination
from ceilometer.event import endpoint as event_endpoint
from ceilometer.i18n import _, _LI, _LW
from ceilometer import exchange_control
from ceilometer import messaging
from ceilometer import pipeline
from ceilometer import service_base
from ceilometer import utils
LOG = log.getLogger(__name__)
OPTS = [
cfg.IntOpt('pipeline_processing_queues',
default=10,
min=1,
help='Number of queues to parallelize workload across. This '
'value should be larger than the number of active '
'notification agents for optimal results.'),
cfg.BoolOpt('ack_on_event_error',
default=True,
deprecated_group='collector',
help='Acknowledge message when event persistence fails.'),
cfg.BoolOpt('store_events',
deprecated_group='collector',
default=False,
help='Save event details.'),
cfg.BoolOpt('disable_non_metric_meters',
default=True,
help='WARNING: Ceilometer historically offered the ability to '
'store events as meters. This usage is NOT advised as it '
'can flood the metering database and cause performance '
'degradation.'),
cfg.BoolOpt('workload_partitioning',
default=False,
help='Enable workload partitioning, allowing multiple '
'notification agents to be run simultaneously.'),
cfg.MultiStrOpt('messaging_urls',
default=[],
secret=True,
help="Messaging URLs to listen for notifications. "
"Example: transport://user:pass@host1:port"
"[,hostN:portN]/virtual_host "
"(DEFAULT/transport_url is used if empty)"),
]
cfg.CONF.register_opts(exchange_control.EXCHANGE_OPTS)
cfg.CONF.register_opts(OPTS, group="notification")
cfg.CONF.import_opt('telemetry_driver', 'ceilometer.publisher.messaging',
group='publisher_notifier')
class NotificationService(service_base.BaseService):
"""Notification service.
When running multiple agents, additional queuing sequence is required for
inter process communication. Each agent has two listeners: one to listen
to the main OpenStack queue and another listener(and notifier) for IPC to
divide pipeline sink endpoints. Coordination should be enabled to have
proper active/active HA.
"""
NOTIFICATION_NAMESPACE = 'ceilometer.notification'
NOTIFICATION_IPC = 'ceilometer-pipe'
def __init__(self, *args, **kwargs):
super(NotificationService, self).__init__(*args, **kwargs)
self.partition_coordinator = None
self.listeners, self.pipeline_listeners = [], []
self.group_id = None
@classmethod
def _get_notifications_manager(cls, pm):
return extension.ExtensionManager(
namespace=cls.NOTIFICATION_NAMESPACE,
invoke_on_load=True,
invoke_args=(pm, )
)
def _get_notifiers(self, transport, pipe):
notifiers = []
for x in range(cfg.CONF.notification.pipeline_processing_queues):
notifiers.append(oslo_messaging.Notifier(
transport,
driver=cfg.CONF.publisher_notifier.telemetry_driver,
publisher_id='ceilometer.notification',
topic='%s-%s-%s' % (self.NOTIFICATION_IPC, pipe.name, x)))
return notifiers
def _get_pipe_manager(self, transport, pipeline_manager):
if cfg.CONF.notification.workload_partitioning:
pipe_manager = pipeline.SamplePipelineTransportManager()
for pipe in pipeline_manager.pipelines:
key = pipeline.get_pipeline_grouping_key(pipe)
pipe_manager.add_transporter(
(pipe.source.support_meter, key or ['resource_id'],
self._get_notifiers(transport, pipe)))
else:
pipe_manager = pipeline_manager
return pipe_manager
def _get_event_pipeline_manager(self, transport):
if cfg.CONF.notification.store_events:
self.event_pipeline_manager = pipeline.setup_event_pipeline()
if cfg.CONF.notification.workload_partitioning:
event_pipe_manager = pipeline.EventPipelineTransportManager()
for pipe in self.event_pipeline_manager.pipelines:
event_pipe_manager.add_transporter(
(pipe.source.support_event, ['event_type'],
self._get_notifiers(transport, pipe)))
else:
event_pipe_manager = self.event_pipeline_manager
return event_pipe_manager
def start(self):
super(NotificationService, self).start()
self.pipeline_manager = pipeline.setup_pipeline()
self.transport = messaging.get_transport()
if cfg.CONF.notification.workload_partitioning:
self.ctxt = context.get_admin_context()
self.group_id = self.NOTIFICATION_NAMESPACE
self.partition_coordinator = coordination.PartitionCoordinator()
self.partition_coordinator.start()
self.partition_coordinator.join_group(self.group_id)
else:
# FIXME(sileht): endpoint uses the notification_topics option
# and it should not because this is an oslo_messaging option
# not a ceilometer. Until we have something to get the
# notification_topics in another way, we must create a transport
# to ensure the option has been registered by oslo_messaging.
messaging.get_notifier(self.transport, '')
self.group_id = None
self.pipe_manager = self._get_pipe_manager(self.transport,
self.pipeline_manager)
self.event_pipe_manager = self._get_event_pipeline_manager(
self.transport)
self.listeners, self.pipeline_listeners = [], []
self._configure_main_queue_listeners(self.pipe_manager,
self.event_pipe_manager)
if cfg.CONF.notification.workload_partitioning:
self._configure_pipeline_listeners()
self.partition_coordinator.watch_group(self.group_id,
self._refresh_agent)
self.tg.add_timer(cfg.CONF.coordination.heartbeat,
self.partition_coordinator.heartbeat)
self.tg.add_timer(cfg.CONF.coordination.check_watchers,
self.partition_coordinator.run_watchers)
if not cfg.CONF.notification.disable_non_metric_meters:
LOG.warning(_LW('Non-metric meters may be collected. It is highly '
'advisable to disable these meters using '
'ceilometer.conf or the pipeline.yaml'))
# Add a dummy thread to have wait() working
self.tg.add_timer(604800, lambda: None)
self.init_pipeline_refresh()
def _configure_main_queue_listeners(self, pipe_manager,
event_pipe_manager):
notification_manager = self._get_notifications_manager(pipe_manager)
if not list(notification_manager):
LOG.warning(_('Failed to load any notification handlers for %s'),
self.NOTIFICATION_NAMESPACE)
ack_on_error = cfg.CONF.notification.ack_on_event_error
endpoints = []
if cfg.CONF.notification.store_events:
endpoints.append(
event_endpoint.EventsNotificationEndpoint(event_pipe_manager))
targets = []
for ext in notification_manager:
handler = ext.obj
if (cfg.CONF.notification.disable_non_metric_meters and
isinstance(handler, base.NonMetricNotificationBase)):
continue
LOG.debug('Event types from %(name)s: %(type)s'
' (ack_on_error=%(error)s)',
{'name': ext.name,
'type': ', '.join(handler.event_types),
'error': ack_on_error})
# NOTE(gordc): this could be a set check but oslo_messaging issue
# https://bugs.launchpad.net/oslo.messaging/+bug/1398511
# This ensures we don't create multiple duplicate consumers.
for new_tar in handler.get_targets(cfg.CONF):
if new_tar not in targets:
targets.append(new_tar)
endpoints.append(handler)
urls = cfg.CONF.notification.messaging_urls or [None]
for url in urls:
transport = messaging.get_transport(url)
listener = messaging.get_notification_listener(
transport, targets, endpoints)
listener.start()
self.listeners.append(listener)
def _refresh_agent(self, event):
self._refresh_listeners()
def _refresh_listeners(self):
utils.kill_listeners(self.pipeline_listeners)
self._configure_pipeline_listeners()
def _configure_pipeline_listeners(self):
self.pipeline_listeners = []
ev_pipes = []
if cfg.CONF.notification.store_events:
ev_pipes = self.event_pipeline_manager.pipelines
pipelines = self.pipeline_manager.pipelines + ev_pipes
transport = messaging.get_transport()
partitioned = self.partition_coordinator.extract_my_subset(
self.group_id,
range(cfg.CONF.notification.pipeline_processing_queues))
for pipe_set in partitioned:
for pipe in pipelines:
LOG.debug('Pipeline endpoint: %s from set: %s', pipe.name,
pipe_set)
pipe_endpoint = (pipeline.EventPipelineEndpoint
if isinstance(pipe, pipeline.EventPipeline)
else pipeline.SamplePipelineEndpoint)
listener = messaging.get_notification_listener(
transport,
[oslo_messaging.Target(
topic='%s-%s-%s' % (self.NOTIFICATION_IPC,
pipe.name, pipe_set))],
[pipe_endpoint(self.ctxt, pipe)])
listener.start()
self.pipeline_listeners.append(listener)
def stop(self):
if self.partition_coordinator:
self.partition_coordinator.stop()
utils.kill_listeners(self.listeners + self.pipeline_listeners)
super(NotificationService, self).stop()
def reload_pipeline(self):
LOG.info(_LI("Reloading notification agent and listeners."))
self.pipe_manager = self._get_pipe_manager(
self.transport, self.pipeline_manager)
self.event_pipe_manager = self._get_event_pipeline_manager(
self.transport)
# re-start the main queue listeners.
utils.kill_listeners(self.listeners)
self._configure_main_queue_listeners(
self.pipe_manager, self.event_pipe_manager)
# re-start the pipeline listeners if workload partitioning
# is enabled.
if cfg.CONF.notification.workload_partitioning:
self._refresh_listeners()