c612727ff8
oslo.log has graduated from oslo-incubator, and openstack.common.log has been removed from oslo-incubator, so let's use the new one. NOTE1:openstack.common.log registers its options at import time, but oslo.log needs to call register_options() explicitly. NOTE2: split unit test case in tests/objectstore/test_swift_middleware.py to avoid duplicate cli option register exception, see NOTE1. Change-Id: Ida30808dbe0c584919755c207ca4ee4b91963a17
107 lines
3.8 KiB
Python
107 lines
3.8 KiB
Python
#
|
|
# Copyright 2013 IBM Corp
|
|
#
|
|
# Licensed under the Apache License, Version 2.0 (the "License"); you may
|
|
# not use this file except in compliance with the License. You may obtain
|
|
# a copy of the License at
|
|
#
|
|
# http://www.apache.org/licenses/LICENSE-2.0
|
|
#
|
|
# Unless required by applicable law or agreed to in writing, software
|
|
# distributed under the License is distributed on an "AS IS" BASIS, WITHOUT
|
|
# WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. See the
|
|
# License for the specific language governing permissions and limitations
|
|
# under the License.
|
|
|
|
import logging
|
|
import logging.handlers
|
|
|
|
from oslo_log import log
|
|
from six.moves.urllib import parse as urlparse
|
|
|
|
import ceilometer
|
|
from ceilometer.i18n import _
|
|
from ceilometer import publisher
|
|
|
|
LOG = log.getLogger(__name__)
|
|
|
|
|
|
class FilePublisher(publisher.PublisherBase):
|
|
"""Publisher metering data to file.
|
|
|
|
The publisher which records metering data into a file. The file name and
|
|
location should be configured in ceilometer pipeline configuration file.
|
|
If a file name and location is not specified, this File Publisher will not
|
|
log any meters other than log a warning in Ceilometer log file.
|
|
|
|
To enable this publisher, add the following section to the
|
|
/etc/ceilometer/publisher.yaml file or simply add it to an existing
|
|
pipeline::
|
|
|
|
-
|
|
name: meter_file
|
|
interval: 600
|
|
counters:
|
|
- "*"
|
|
transformers:
|
|
publishers:
|
|
- file:///var/test?max_bytes=10000000&backup_count=5
|
|
|
|
File path is required for this publisher to work properly. If max_bytes
|
|
or backup_count is missing, FileHandler will be used to save the metering
|
|
data. If max_bytes and backup_count are present, RotatingFileHandler will
|
|
be used to save the metering data.
|
|
"""
|
|
|
|
def __init__(self, parsed_url):
|
|
super(FilePublisher, self).__init__(parsed_url)
|
|
|
|
self.publisher_logger = None
|
|
path = parsed_url.path
|
|
if not path or path.lower() == 'file':
|
|
LOG.error(_('The path for the file publisher is required'))
|
|
return
|
|
|
|
rfh = None
|
|
max_bytes = 0
|
|
backup_count = 0
|
|
# Handling other configuration options in the query string
|
|
if parsed_url.query:
|
|
params = urlparse.parse_qs(parsed_url.query)
|
|
if params.get('max_bytes') and params.get('backup_count'):
|
|
try:
|
|
max_bytes = int(params.get('max_bytes')[0])
|
|
backup_count = int(params.get('backup_count')[0])
|
|
except ValueError:
|
|
LOG.error(_('max_bytes and backup_count should be '
|
|
'numbers.'))
|
|
return
|
|
# create rotating file handler
|
|
rfh = logging.handlers.RotatingFileHandler(
|
|
path, encoding='utf8', maxBytes=max_bytes,
|
|
backupCount=backup_count)
|
|
|
|
self.publisher_logger = logging.Logger('publisher.file')
|
|
self.publisher_logger.propagate = False
|
|
self.publisher_logger.setLevel(logging.INFO)
|
|
rfh.setLevel(logging.INFO)
|
|
self.publisher_logger.addHandler(rfh)
|
|
|
|
def publish_samples(self, context, samples):
|
|
"""Send a metering message for publishing
|
|
|
|
:param context: Execution context from the service or RPC call
|
|
:param samples: Samples from pipeline after transformation
|
|
"""
|
|
if self.publisher_logger:
|
|
for sample in samples:
|
|
self.publisher_logger.info(sample.as_dict())
|
|
|
|
def publish_events(self, context, events):
|
|
"""Send an event message for publishing
|
|
|
|
:param context: Execution context from the service or RPC call
|
|
:param events: events from pipeline after transformation
|
|
"""
|
|
raise ceilometer.NotImplementedError
|