Make ceilometer hardware meters work out of the box
Although we were configuring the ceilometer hardware section on the
undercloud, none of the hardware meters were showing up in
ceilometer. There are a couple of reasons for this:
1) The auto-generated readonly SNMP username was too long. It seems
to have a limit of 32 characters, and we default to generating
a 40 character value.
2) The generated SNMP username wasn't automatically passed to the
overcloud template, so by default the overcloud was deploying
with an SNMP user named ro_snmp_user, regardless of what was
configured on the undercloud.
To address these issues, this change sets the default SNMP user
to ro_snmp_user so it is not necessary to pass it as a parameter
in a default install. It also makes a note of the length
restrictions on custom values.
Change-Id: I99768fd402a13056adef7fdafd8568ff5f08d1a1
(cherry picked from commit 00dd8c82de
)
This commit is contained in:
parent
dd2f653a34
commit
874d11bf64
@ -232,8 +232,12 @@ _auth_opts = [
|
|||||||
'If left unset, one will be automatically generated.')
|
'If left unset, one will be automatically generated.')
|
||||||
),
|
),
|
||||||
cfg.StrOpt('undercloud_ceilometer_snmpd_user',
|
cfg.StrOpt('undercloud_ceilometer_snmpd_user',
|
||||||
help=('Ceilometer snmpd user. '
|
default='ro_snmp_user',
|
||||||
'If left unset, one will be automatically generated.')
|
help=('Ceilometer snmpd read-only user. If this value is '
|
||||||
|
'changed from the default, the new value must be passed '
|
||||||
|
'in the overcloud environment as the parameter '
|
||||||
|
'SnmpdReadonlyUserName. This value must be between '
|
||||||
|
'1 and 32 characters long.')
|
||||||
),
|
),
|
||||||
cfg.StrOpt('undercloud_ceilometer_snmpd_password',
|
cfg.StrOpt('undercloud_ceilometer_snmpd_password',
|
||||||
help=('Ceilometer snmpd password. '
|
help=('Ceilometer snmpd password. '
|
||||||
|
@ -141,9 +141,11 @@
|
|||||||
# generated. (string value)
|
# generated. (string value)
|
||||||
#undercloud_ceilometer_metering_secret = <None>
|
#undercloud_ceilometer_metering_secret = <None>
|
||||||
|
|
||||||
# Ceilometer snmpd user. If left unset, one will be automatically
|
# Ceilometer snmpd read-only user. If this value is changed from the
|
||||||
# generated. (string value)
|
# default, the new value must be passed in the overcloud environment
|
||||||
#undercloud_ceilometer_snmpd_user = <None>
|
# as the parameter SnmpdReadonlyUserName. This value must be between 1
|
||||||
|
# and 32 characters long. (string value)
|
||||||
|
#undercloud_ceilometer_snmpd_user = ro_snmp_user
|
||||||
|
|
||||||
# Ceilometer snmpd password. If left unset, one will be automatically
|
# Ceilometer snmpd password. If left unset, one will be automatically
|
||||||
# generated. (string value)
|
# generated. (string value)
|
||||||
|
Loading…