Document cmdb file for RAID and BIOS config
Change-Id: Ib74bfae550f73e9c8585aa7d8a1559bf34c8967d
This commit is contained in:
parent
86cddf125a
commit
f84500b20b
|
@ -7,7 +7,7 @@ In this chapter you will find advanced deployment of various RDO-Manager areas.
|
|||
.. toctree::
|
||||
|
||||
Advanced Profile Matching <profile_matching>
|
||||
Ready-States (BIOS, RAID) <ready_states>
|
||||
Ready-State (BIOS, RAID) <ready_state>
|
||||
Automated Health Check <automated_health_check>
|
||||
|
||||
|
||||
|
|
|
@ -0,0 +1,109 @@
|
|||
Ready-State (BIOS, RAID)
|
||||
========================
|
||||
|
||||
Ready-state configuration can be used to prepare bare-metal resources for
|
||||
deployment. It includes BIOS and RAID configuration based on a predefined
|
||||
profile.
|
||||
|
||||
To define the target BIOS and RAID configuration for a deployment profile, you
|
||||
need to create a JSON-like ``<profile>.cmdb`` file in
|
||||
``/etc/ahc-tools/edeploy``. The configuration will be applied only to nodes
|
||||
that match the ``<profile>.specs`` rules.
|
||||
|
||||
|
||||
Define the target BIOS configuration
|
||||
------------------------------------
|
||||
|
||||
To define a BIOS setting, list the name of the setting and its target
|
||||
value::
|
||||
|
||||
[
|
||||
{
|
||||
'bios_settings': {'ProcVirtualization': 'Enabled'}
|
||||
}
|
||||
]
|
||||
|
||||
|
||||
Define the target RAID configuration
|
||||
------------------------------------
|
||||
|
||||
The RAID configuration can be defined in 2 ways: either by listing the IDs
|
||||
of the physical disks, or letting Ironic assign physical disks to the
|
||||
RAID volume.
|
||||
|
||||
By providing a list of physical disk IDs the following attributes are required:
|
||||
``controller``, ``size_gb``, ``raid_level`` and the list of ``physical_disks``.
|
||||
``controller`` should be the FQDD of the RAID controller assigned by the DRAC
|
||||
card. Similarly, the list of ``physical_disks`` should be the FQDDs of physical
|
||||
disks assigned by the DRAC card. An example::
|
||||
|
||||
[
|
||||
{
|
||||
'logical_disks': [
|
||||
{'controller': 'RAID.Integrated.1-1',
|
||||
'size_gb': 100,
|
||||
'physical_disks': [
|
||||
'Disk.Bay.0:Enclosure.Internal.0-1:RAID.Integrated.1-1',
|
||||
'Disk.Bay.1:Enclosure.Internal.0-1:RAID.Integrated.1-1',
|
||||
'Disk.Bay.2:Enclosure.Internal.0-1:RAID.Integrated.1-1'],
|
||||
'raid_level': '5'},
|
||||
]
|
||||
}
|
||||
]
|
||||
|
||||
By letting Ironic assign physical disks to the RAID volume, the following
|
||||
attributes are required: ``controller``, ``size_gb``, ``raid_level`` and the
|
||||
``number_of_physical_disks``. ``controller`` should be the FQDD of the RAID
|
||||
controller assigned by the DRAC card. An example::
|
||||
|
||||
[
|
||||
{
|
||||
'logical_disks': [
|
||||
{'controller': 'RAID.Integrated.1-1',
|
||||
'size_gb': 50,
|
||||
'raid_level': '1',
|
||||
'number_of_physical_disks': 2},
|
||||
]
|
||||
}
|
||||
]
|
||||
|
||||
|
||||
Complete example for a ``control.cmdb``
|
||||
---------------------------------------
|
||||
::
|
||||
|
||||
[
|
||||
{
|
||||
'bios_settings': {'ProcVirtualization': 'Enabled'},
|
||||
'logical_disks': [
|
||||
{'controller': 'RAID.Integrated.1-1',
|
||||
'size_gb': 50,
|
||||
'raid_level': '1',
|
||||
'number_of_physical_disks': 2,
|
||||
'disk_type': 'hdd',
|
||||
'interface_type': 'sas',
|
||||
'volume_name': 'root_volume',
|
||||
'is_root_volume': True},
|
||||
{'controller': 'RAID.Integrated.1-1',
|
||||
'size_gb': 100,
|
||||
'physical_disks': [
|
||||
'Disk.Bay.0:Enclosure.Internal.0-1:RAID.Integrated.1-1',
|
||||
'Disk.Bay.1:Enclosure.Internal.0-1:RAID.Integrated.1-1',
|
||||
'Disk.Bay.2:Enclosure.Internal.0-1:RAID.Integrated.1-1'],
|
||||
'raid_level': '5',
|
||||
'volume_name': 'data_volume1'}
|
||||
]
|
||||
}
|
||||
]
|
||||
|
||||
|
||||
Trigger the ready-state configuration
|
||||
-------------------------------------
|
||||
|
||||
Continue with matching the nodes to profiles as described in
|
||||
:doc:`profile_matching`.
|
||||
|
||||
Then trigger the BIOS and RAID configuration based on the matched deployment
|
||||
profile::
|
||||
|
||||
instack-ironic-deployment --configure-nodes
|
|
@ -1,9 +0,0 @@
|
|||
Ready-State (BIOS, RAID)
|
||||
========================
|
||||
|
||||
Start with matching the nodes to profiles as described in
|
||||
:doc:`profile_matching`.
|
||||
|
||||
Then trigger the BIOS and RAID configuration based on the deployment profile::
|
||||
|
||||
instack-ironic-deployment --configure-nodes
|
Loading…