[Devstack]: pick correct MTU for br-inspector veth
This patch pick correct MTU for veth pair created by inspector to avoid errors when packets are dropped. Change-Id: Ie1036ca75c9561393f4efc2478d0a2c9cba9e089
This commit is contained in:
parent
8dc2d00d91
commit
328acd4d0a
|
@ -259,6 +259,8 @@ function prepare_environment {
|
|||
sudo ovs-vsctl add-port $IRONIC_VM_NETWORK_BRIDGE brbm-inspector
|
||||
fi
|
||||
sudo ip link set dev $IRONIC_INSPECTOR_INTERFACE up
|
||||
sudo ip link set dev brbm-inspector mtu $PUBLIC_BRIDGE_MTU
|
||||
sudo ip link set dev $IRONIC_INSPECTOR_INTERFACE mtu $PUBLIC_BRIDGE_MTU
|
||||
sudo ip addr add $IRONIC_INSPECTOR_INTERNAL_IP_WITH_NET dev $IRONIC_INSPECTOR_INTERFACE
|
||||
|
||||
sudo iptables -I INPUT -i $IRONIC_INSPECTOR_INTERFACE -p udp \
|
||||
|
|