Merge "Skip BMC detection when using out-of-band management"
This commit is contained in:
@@ -494,6 +494,15 @@ class IronicPythonAgent(base.ExecuteCommandMixin):
|
||||
self.node = content['node']
|
||||
LOG.info('Lookup succeeded, node UUID is %s',
|
||||
self.node['uuid'])
|
||||
|
||||
# Store skip_bmc_detect flag in the node before caching
|
||||
# This allows hardware managers to check if BMC detection is needed
|
||||
skip_bmc = content.get('config', {}).get('agent_skip_bmc_detect',
|
||||
False)
|
||||
if skip_bmc:
|
||||
LOG.info('Ironic has indicated BMC detection should be skipped')
|
||||
self.node['skip_bmc_detect'] = True
|
||||
|
||||
hardware.cache_node(self.node)
|
||||
self.heartbeat_timeout = content['config']['heartbeat_timeout']
|
||||
|
||||
|
||||
@@ -1151,18 +1151,52 @@ class HardwareManager(object, metaclass=abc.ABCMeta):
|
||||
hardware_info['cpu'] = self.get_cpus()
|
||||
hardware_info['disks'] = self.list_block_devices()
|
||||
hardware_info['memory'] = self.get_memory()
|
||||
hardware_info['bmc_address'] = self.get_bmc_address()
|
||||
hardware_info['bmc_v6address'] = self.get_bmc_v6address()
|
||||
|
||||
# Check if Ironic has indicated BMC detection should be skipped
|
||||
# This is set after lookup when using out-of-band
|
||||
# management like Redfish
|
||||
cached_node = get_cached_node()
|
||||
skip_bmc = (cached_node and cached_node.get('skip_bmc_detect',
|
||||
False))
|
||||
|
||||
if skip_bmc:
|
||||
LOG.info('Skipping BMC detection as requested by Ironic')
|
||||
hardware_info['bmc_address'] = None
|
||||
hardware_info['bmc_v6address'] = None
|
||||
else:
|
||||
# Cache BMC information to avoid repeated expensive ipmitool calls
|
||||
if not hasattr(self, '_bmc_cache'):
|
||||
LOG.debug('Detecting BMC information (first time)')
|
||||
self._bmc_cache = {
|
||||
'bmc_address': self.get_bmc_address(),
|
||||
'bmc_v6address': self.get_bmc_v6address(),
|
||||
'bmc_mac': None # Populated below
|
||||
}
|
||||
else:
|
||||
LOG.debug('Using cached BMC information')
|
||||
|
||||
hardware_info['bmc_address'] = self._bmc_cache['bmc_address']
|
||||
hardware_info['bmc_v6address'] = self._bmc_cache['bmc_v6address']
|
||||
|
||||
hardware_info['system_vendor'] = self.get_system_vendor_info()
|
||||
hardware_info['boot'] = self.get_boot_info()
|
||||
hardware_info['hostname'] = netutils.get_hostname()
|
||||
|
||||
try:
|
||||
hardware_info['bmc_mac'] = self.get_bmc_mac()
|
||||
except errors.IncompatibleHardwareMethodError:
|
||||
# if the hardware manager does not support obtaining the BMC MAC,
|
||||
# we simply don't expose it.
|
||||
pass
|
||||
if not skip_bmc:
|
||||
# Try to get BMC MAC, which may not be cached yet
|
||||
if self._bmc_cache['bmc_mac'] is None:
|
||||
try:
|
||||
self._bmc_cache['bmc_mac'] = self.get_bmc_mac()
|
||||
LOG.debug('Cached BMC MAC address')
|
||||
except errors.IncompatibleHardwareMethodError:
|
||||
# if the hardware manager does not support obtaining
|
||||
# the BMC MAC, we simply don't expose it.
|
||||
# Mark as unavailable to avoid retrying
|
||||
self._bmc_cache['bmc_mac'] = 'unavailable'
|
||||
|
||||
# Only add to hardware_info if we successfully got it
|
||||
if self._bmc_cache['bmc_mac'] not in (None, 'unavailable'):
|
||||
hardware_info['bmc_mac'] = self._bmc_cache['bmc_mac']
|
||||
|
||||
LOG.info('Inventory collected in %.2f second(s)', time.time() - start)
|
||||
return hardware_info
|
||||
|
||||
@@ -1509,6 +1509,133 @@ class TestGenericHardwareManager(base.IronicAgentTest):
|
||||
self.assertEqual('mock_hostname', hardware_info['hostname'])
|
||||
mocked_lshw.assert_called_once_with(self.hardware)
|
||||
|
||||
@mock.patch.object(hardware, 'get_cached_node', autospec=True)
|
||||
@mock.patch.object(hardware.GenericHardwareManager,
|
||||
'_get_system_lshw_dict', autospec=True,
|
||||
return_value={'id': 'host'})
|
||||
@mock.patch.object(netutils, 'get_hostname', autospec=True)
|
||||
def test_list_hardware_info_with_bmc_caching(
|
||||
self, mocked_get_hostname, mocked_lshw, mocked_get_node):
|
||||
"""Test that BMC information is cached after first detection."""
|
||||
mocked_get_node.return_value = None # No skip_bmc_detect flag
|
||||
|
||||
# Mock all the hardware info methods
|
||||
self.hardware.list_network_interfaces = mock.Mock(return_value=[])
|
||||
self.hardware.get_cpus = mock.Mock()
|
||||
self.hardware.get_memory = mock.Mock()
|
||||
self.hardware.list_block_devices = mock.Mock(return_value=[])
|
||||
self.hardware.get_boot_info = mock.Mock()
|
||||
self.hardware.get_system_vendor_info = mock.Mock()
|
||||
mocked_get_hostname.return_value = 'mock_hostname'
|
||||
|
||||
# Mock BMC methods
|
||||
self.hardware.get_bmc_address = mock.Mock(return_value='192.168.1.1')
|
||||
self.hardware.get_bmc_v6address = mock.Mock(return_value='fe80::1')
|
||||
self.hardware.get_bmc_mac = mock.Mock(return_value='aa:bb:cc:dd:ee:ff')
|
||||
|
||||
# First call - should call BMC detection methods
|
||||
hardware_info1 = self.hardware.list_hardware_info()
|
||||
self.assertEqual('192.168.1.1', hardware_info1['bmc_address'])
|
||||
self.assertEqual('fe80::1', hardware_info1['bmc_v6address'])
|
||||
self.assertEqual('aa:bb:cc:dd:ee:ff', hardware_info1['bmc_mac'])
|
||||
|
||||
# Verify BMC methods were called
|
||||
self.hardware.get_bmc_address.assert_called_once()
|
||||
self.hardware.get_bmc_v6address.assert_called_once()
|
||||
self.hardware.get_bmc_mac.assert_called_once()
|
||||
|
||||
# Second call - should use cached values
|
||||
hardware_info2 = self.hardware.list_hardware_info()
|
||||
self.assertEqual('192.168.1.1', hardware_info2['bmc_address'])
|
||||
self.assertEqual('fe80::1', hardware_info2['bmc_v6address'])
|
||||
self.assertEqual('aa:bb:cc:dd:ee:ff', hardware_info2['bmc_mac'])
|
||||
|
||||
# BMC methods should NOT be called again (still only once)
|
||||
self.hardware.get_bmc_address.assert_called_once()
|
||||
self.hardware.get_bmc_v6address.assert_called_once()
|
||||
self.hardware.get_bmc_mac.assert_called_once()
|
||||
|
||||
@mock.patch.object(hardware, 'get_cached_node', autospec=True)
|
||||
@mock.patch.object(hardware.GenericHardwareManager,
|
||||
'_get_system_lshw_dict', autospec=True,
|
||||
return_value={'id': 'host'})
|
||||
@mock.patch.object(netutils, 'get_hostname', autospec=True)
|
||||
def test_list_hardware_info_skip_bmc_detect(
|
||||
self, mocked_get_hostname, mocked_lshw, mocked_get_node):
|
||||
"""Test that BMC detection is skipped when flag is set."""
|
||||
mocked_get_node.return_value = {'skip_bmc_detect': True}
|
||||
|
||||
# Mock all the hardware info methods
|
||||
self.hardware.list_network_interfaces = mock.Mock(return_value=[])
|
||||
self.hardware.get_cpus = mock.Mock()
|
||||
self.hardware.get_memory = mock.Mock()
|
||||
self.hardware.list_block_devices = mock.Mock(return_value=[])
|
||||
self.hardware.get_boot_info = mock.Mock()
|
||||
self.hardware.get_system_vendor_info = mock.Mock()
|
||||
mocked_get_hostname.return_value = 'mock_hostname'
|
||||
|
||||
# Mock BMC methods - these should NOT be called
|
||||
self.hardware.get_bmc_address = mock.Mock()
|
||||
self.hardware.get_bmc_v6address = mock.Mock()
|
||||
self.hardware.get_bmc_mac = mock.Mock()
|
||||
|
||||
# Call list_hardware_info
|
||||
hardware_info = self.hardware.list_hardware_info()
|
||||
|
||||
# BMC info should be None
|
||||
self.assertIsNone(hardware_info['bmc_address'])
|
||||
self.assertIsNone(hardware_info['bmc_v6address'])
|
||||
self.assertNotIn('bmc_mac', hardware_info)
|
||||
|
||||
# BMC detection methods should NOT have been called
|
||||
self.hardware.get_bmc_address.assert_not_called()
|
||||
self.hardware.get_bmc_v6address.assert_not_called()
|
||||
self.hardware.get_bmc_mac.assert_not_called()
|
||||
|
||||
@mock.patch.object(hardware, 'get_cached_node', autospec=True)
|
||||
@mock.patch.object(hardware.GenericHardwareManager,
|
||||
'_get_system_lshw_dict', autospec=True,
|
||||
return_value={'id': 'host'})
|
||||
@mock.patch.object(netutils, 'get_hostname', autospec=True)
|
||||
def test_list_hardware_info_bmc_mac_unavailable(
|
||||
self, mocked_get_hostname, mocked_lshw, mocked_get_node):
|
||||
"""Test BMC MAC marked unavailable when not supported."""
|
||||
mocked_get_node.return_value = None
|
||||
|
||||
# Mock all the hardware info methods
|
||||
self.hardware.list_network_interfaces = mock.Mock(return_value=[])
|
||||
self.hardware.get_cpus = mock.Mock()
|
||||
self.hardware.get_memory = mock.Mock()
|
||||
self.hardware.list_block_devices = mock.Mock(return_value=[])
|
||||
self.hardware.get_boot_info = mock.Mock()
|
||||
self.hardware.get_system_vendor_info = mock.Mock()
|
||||
mocked_get_hostname.return_value = 'mock_hostname'
|
||||
|
||||
# Mock BMC methods
|
||||
self.hardware.get_bmc_address = mock.Mock(return_value='192.168.1.1')
|
||||
self.hardware.get_bmc_v6address = mock.Mock(return_value='fe80::1')
|
||||
# BMC MAC raises IncompatibleHardwareMethodError
|
||||
self.hardware.get_bmc_mac = mock.Mock(
|
||||
side_effect=errors.IncompatibleHardwareMethodError)
|
||||
|
||||
# First call
|
||||
hardware_info1 = self.hardware.list_hardware_info()
|
||||
self.assertEqual('192.168.1.1', hardware_info1['bmc_address'])
|
||||
self.assertEqual('fe80::1', hardware_info1['bmc_v6address'])
|
||||
self.assertNotIn('bmc_mac', hardware_info1) # Not in output
|
||||
|
||||
# Verify get_bmc_mac was called once
|
||||
self.hardware.get_bmc_mac.assert_called_once()
|
||||
|
||||
# Second call - get_bmc_mac should NOT be called again
|
||||
hardware_info2 = self.hardware.list_hardware_info()
|
||||
self.assertEqual('192.168.1.1', hardware_info2['bmc_address'])
|
||||
self.assertEqual('fe80::1', hardware_info2['bmc_v6address'])
|
||||
self.assertNotIn('bmc_mac', hardware_info2)
|
||||
|
||||
# Still only one call (cached as 'unavailable')
|
||||
self.hardware.get_bmc_mac.assert_called_once()
|
||||
|
||||
@mock.patch.object(hardware, 'list_all_block_devices', autospec=True)
|
||||
def test_list_block_devices(self, list_mock):
|
||||
device = hardware.BlockDevice('/dev/hdaa', 'small', 65535, False)
|
||||
|
||||
@@ -0,0 +1,13 @@
|
||||
---
|
||||
features:
|
||||
- |
|
||||
Adds support for automatically skipping BMC detection via ipmitool
|
||||
when Ironic indicates the node uses out-of-band management interfaces
|
||||
(e.g., Redfish, iDRAC Redfish, iLO, iRMC). This reduces deployment
|
||||
time and avoids unnecessary ipmitool calls when the BMC information
|
||||
is already known to Ironic.
|
||||
- |
|
||||
BMC information (address, v6address, and MAC) is now cached after the
|
||||
first detection to avoid repeated expensive ipmitool calls during
|
||||
subsequent inventory collections. This improves performance during
|
||||
heartbeats and long-running operations like cleaning or rescue mode.
|
||||
Reference in New Issue