3e05a03f7c
Binary LLDP data is bloating inventory causing us to disable its collection by default. For other similar low-level information, such as PCI devices or DMI data, we already use inspection collectors instead. Now that the inventory format is shared with out-of-band inspection, having LLDP there makes even less sense. This change adds a new collector ``lldp`` to replace the now-deprecated inventory field. Change-Id: I56be06a7d1db28407e1128c198c12bea0809d3a3
3328 lines
135 KiB
Python
3328 lines
135 KiB
Python
# Copyright 2013 Rackspace, Inc.
|
|
#
|
|
# Licensed under the Apache License, Version 2.0 (the "License");
|
|
# you may not use this file except in compliance with the License.
|
|
# You may obtain a copy of the License at
|
|
#
|
|
# http://www.apache.org/licenses/LICENSE-2.0
|
|
#
|
|
# Unless required by applicable law or agreed to in writing, software
|
|
# distributed under the License is distributed on an "AS IS" BASIS,
|
|
# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
|
|
# See the License for the specific language governing permissions and
|
|
# limitations under the License.
|
|
|
|
import abc
|
|
import binascii
|
|
import collections
|
|
import functools
|
|
import io
|
|
import ipaddress
|
|
import json
|
|
from multiprocessing.pool import ThreadPool
|
|
import os
|
|
import re
|
|
import shlex
|
|
import shutil
|
|
import stat
|
|
import string
|
|
import time
|
|
|
|
from ironic_lib import disk_utils
|
|
from ironic_lib import utils as il_utils
|
|
from oslo_concurrency import processutils
|
|
from oslo_config import cfg
|
|
from oslo_log import log
|
|
import pint
|
|
import psutil
|
|
import pyudev
|
|
import stevedore
|
|
import yaml
|
|
|
|
from ironic_python_agent import burnin
|
|
from ironic_python_agent import encoding
|
|
from ironic_python_agent import errors
|
|
from ironic_python_agent.extensions import base as ext_base
|
|
from ironic_python_agent import inject_files
|
|
from ironic_python_agent import netutils
|
|
from ironic_python_agent import raid_utils
|
|
from ironic_python_agent import tls_utils
|
|
from ironic_python_agent import utils
|
|
|
|
_global_managers = None
|
|
LOG = log.getLogger()
|
|
CONF = cfg.CONF
|
|
|
|
WARN_BIOSDEVNAME_NOT_FOUND = False
|
|
|
|
UNIT_CONVERTER = pint.UnitRegistry(filename=None)
|
|
UNIT_CONVERTER.define('bytes = []')
|
|
UNIT_CONVERTER.define('MB = 1048576 bytes')
|
|
_MEMORY_ID_RE = re.compile(r'^memory(:\d+)?$')
|
|
NODE = None
|
|
API_CLIENT = None
|
|
API_LOOKUP_TIMEOUT = None
|
|
API_LOOKUP_INTERVAL = None
|
|
SUPPORTED_SOFTWARE_RAID_LEVELS = frozenset(['0', '1', '1+0', '5', '6'])
|
|
NVME_CLI_FORMAT_SUPPORTED_FLAG = 0b10
|
|
NVME_CLI_CRYPTO_FORMAT_SUPPORTED_FLAG = 0b100
|
|
|
|
RAID_APPLY_CONFIGURATION_ARGSINFO = {
|
|
"raid_config": {
|
|
"description": "The RAID configuration to apply.",
|
|
"required": True,
|
|
},
|
|
"delete_existing": {
|
|
"description": (
|
|
"Setting this to 'True' indicates to delete existing RAID "
|
|
"configuration prior to creating the new configuration. "
|
|
"Default value is 'True'."
|
|
),
|
|
"required": False,
|
|
}
|
|
}
|
|
|
|
MULTIPATH_ENABLED = None
|
|
|
|
|
|
def _get_device_info(dev, devclass, field):
|
|
"""Get the device info according to device class and field."""
|
|
try:
|
|
devname = os.path.basename(dev)
|
|
with open('/sys/class/%s/%s/device/%s' % (devclass, devname, field),
|
|
'r') as f:
|
|
return f.read().strip()
|
|
except IOError:
|
|
LOG.warning("Can't find field %(field)s for"
|
|
"device %(dev)s in device class %(class)s",
|
|
{'field': field, 'dev': dev, 'class': devclass})
|
|
|
|
|
|
def _get_system_lshw_dict():
|
|
"""Get a dict representation of the system from lshw
|
|
|
|
Retrieves a json representation of the system from lshw and converts
|
|
it to a python dict
|
|
|
|
:return: A python dict from the lshw json output
|
|
"""
|
|
out, _e = il_utils.execute('lshw', '-quiet', '-json', log_stdout=False)
|
|
out = json.loads(out)
|
|
# Depending on lshw version, output might be a list, starting with
|
|
# https://github.com/lyonel/lshw/commit/135a853c60582b14c5b67e5cd988a8062d9896f4 # noqa
|
|
if isinstance(out, list):
|
|
return out[0]
|
|
return out
|
|
|
|
|
|
def _udev_settle():
|
|
"""Wait for the udev event queue to settle.
|
|
|
|
Wait for the udev event queue to settle to make sure all devices
|
|
are detected once the machine boots up.
|
|
|
|
"""
|
|
try:
|
|
il_utils.execute('udevadm', 'settle')
|
|
except processutils.ProcessExecutionError as e:
|
|
LOG.warning('Something went wrong when waiting for udev '
|
|
'to settle. Error: %s', e)
|
|
return
|
|
|
|
|
|
def _load_ipmi_modules():
|
|
"""Load kernel modules required for IPMI interaction.
|
|
|
|
This is required to be called at least once before attempting to use
|
|
ipmitool or related tools.
|
|
"""
|
|
il_utils.try_execute('modprobe', 'ipmi_msghandler')
|
|
il_utils.try_execute('modprobe', 'ipmi_devintf')
|
|
il_utils.try_execute('modprobe', 'ipmi_si')
|
|
|
|
|
|
def _load_multipath_modules():
|
|
"""Load multipath modules
|
|
|
|
This is required to be able to collect multipath information.
|
|
|
|
Two separate paths exist, one with a helper utility for Centos/RHEL
|
|
and another which is just load the modules, and trust multipathd
|
|
will do the needful.
|
|
"""
|
|
if (os.path.isfile('/usr/sbin/mpathconf')
|
|
and not os.path.isfile('/etc/multipath.conf')):
|
|
# For Centos/Rhel/Etc which uses mpathconf, this does
|
|
# a couple different things, including configuration generation...
|
|
# which is not *really* required.. at least *shouldn't* be.
|
|
# WARNING(TheJulia): This command explicitly replaces local
|
|
# configuration.
|
|
il_utils.try_execute('/usr/sbin/mpathconf', '--enable',
|
|
'--find_multipaths', 'yes',
|
|
'--with_module', 'y',
|
|
'--with_multipathd', 'y')
|
|
else:
|
|
# Ensure modules are loaded. Configuration is not required
|
|
# and implied based upon compiled in defaults.
|
|
# NOTE(TheJulia): Debian/Ubuntu specifically just document
|
|
# using `multipath -t` output to start a new configuration
|
|
# file, if needed.
|
|
il_utils.try_execute('modprobe', 'dm_multipath')
|
|
il_utils.try_execute('modprobe', 'multipath')
|
|
|
|
|
|
def _check_for_iscsi():
|
|
"""Connect iSCSI shared connected via iBFT or OF.
|
|
|
|
iscsistart -f will print the iBFT or OF info.
|
|
In case such connection exists, we would like to issue
|
|
iscsistart -b to create a session to the target.
|
|
- If no connection is detected we simply return.
|
|
"""
|
|
try:
|
|
il_utils.execute('iscsistart', '-f')
|
|
except (processutils.ProcessExecutionError, EnvironmentError) as e:
|
|
LOG.debug("No iscsi connection detected. Skipping iscsi. "
|
|
"Error: %s", e)
|
|
return
|
|
try:
|
|
il_utils.execute('iscsistart', '-b')
|
|
except processutils.ProcessExecutionError as e:
|
|
LOG.warning("Something went wrong executing 'iscsistart -b' "
|
|
"Error: %s", e)
|
|
|
|
|
|
def _get_md_uuid(raid_device):
|
|
"""Get the md UUID of a Software RAID device.
|
|
|
|
:param raid_device: A Software RAID block device name.
|
|
:returns: A string containing the UUID of an md device.
|
|
"""
|
|
try:
|
|
out, _ = il_utils.execute('mdadm', '--detail', raid_device,
|
|
use_standard_locale=True)
|
|
except processutils.ProcessExecutionError as e:
|
|
LOG.warning('Could not get the details of %(dev)s: %(err)s',
|
|
{'dev': raid_device, 'err': e})
|
|
return
|
|
|
|
lines = out.splitlines()
|
|
# the first line contains the md device itself
|
|
for line in lines[1:]:
|
|
match = re.search(r'UUID : ([a-f0-9:]+)', line)
|
|
if match:
|
|
return match.group(1)
|
|
|
|
|
|
def _enable_multipath():
|
|
"""Initialize multipath IO if possible.
|
|
|
|
:returns: True if the multipathd daemon and multipath command to enumerate
|
|
devices was scucessfully able to be called.
|
|
"""
|
|
try:
|
|
_load_multipath_modules()
|
|
# This might not work, ideally it *should* already be running...
|
|
# NOTE(TheJulia): Testing locally, a prior running multipathd, the
|
|
# explicit multipathd start just appears to silently exit with a
|
|
# result code of 0.
|
|
il_utils.execute('multipathd')
|
|
# This is mainly to get the system to actually do the needful and
|
|
# identify/enumerate paths by combining what it can detect and what
|
|
# it already knows. This may be useful, and in theory this should be
|
|
# logged in the IPA log should it be needed.
|
|
il_utils.execute('multipath', '-ll')
|
|
return True
|
|
except FileNotFoundError as e:
|
|
LOG.warning('Attempted to determine if multipath tools were present. '
|
|
'Not detected. Error recorded: %s', e)
|
|
return False
|
|
except processutils.ProcessExecutionError as e:
|
|
LOG.warning('Attempted to invoke multipath utilities, but we '
|
|
'encountered an error: %s', e)
|
|
return False
|
|
|
|
|
|
def _get_multipath_parent_device(device):
|
|
"""Check and return a multipath device."""
|
|
if not device:
|
|
# if lsblk provides invalid output, this can be None.
|
|
return
|
|
check_device = os.path.join('/dev', str(device))
|
|
try:
|
|
# Explicitly run the check as regardless of if the device is mpath or
|
|
# not, multipath tools when using list always exits with a return
|
|
# code of 0.
|
|
il_utils.execute('multipath', '-c', check_device)
|
|
# path check with return an exit code of 1 if you send it a multipath
|
|
# device mapper device, like dm-0.
|
|
# NOTE(TheJulia): -ll is supposed to load from all available
|
|
# information, but may not force a rescan. It may be -f if we need
|
|
# that. That being said, it has been about a decade since I was
|
|
# running multipath tools on SAN connected gear, so my memory is
|
|
# definitely fuzzy.
|
|
out, _ = il_utils.execute('multipath', '-ll', check_device)
|
|
except processutils.ProcessExecutionError as e:
|
|
# FileNotFoundError if the utility does not exist.
|
|
# -1 return code if the device is not valid.
|
|
LOG.debug('Checked device %(dev)s and determined it was '
|
|
'not a multipath device. %(error)s',
|
|
{'dev': check_device,
|
|
'error': e})
|
|
return
|
|
except FileNotFoundError:
|
|
# This should never happen, as MULTIPATH_ENABLED would be False
|
|
# before this occurs.
|
|
LOG.warning('Attempted to check multipathing status, however '
|
|
'the \'multipath\' binary is missing or not in the '
|
|
'execution PATH.')
|
|
return
|
|
# Data format:
|
|
# MPATHDEVICENAME dm-0 TYPE,HUMANNAME
|
|
# size=56G features='1 retain_attached_hw_handler' hwhandler='0' wp=rw
|
|
# `-+- policy='service-time 0' prio=1 status=active
|
|
# `- 0:0:0:0 sda 8:0 active ready running
|
|
try:
|
|
lines = out.splitlines()
|
|
mpath_device = lines[0].split(' ')[1]
|
|
# give back something like dm-0 so we can log it.
|
|
return mpath_device
|
|
except IndexError:
|
|
# We didn't get any command output, so Nope.
|
|
pass
|
|
|
|
|
|
def get_component_devices(raid_device):
|
|
"""Get the component devices of a Software RAID device.
|
|
|
|
Get the UUID of the md device and scan all other devices
|
|
for the same md UUID.
|
|
|
|
:param raid_device: A Software RAID block device name.
|
|
:returns: A list of the component devices.
|
|
"""
|
|
if not raid_device:
|
|
return []
|
|
|
|
md_uuid = _get_md_uuid(raid_device)
|
|
if not md_uuid:
|
|
return []
|
|
LOG.debug('%(device)s has UUID %(uuid)s',
|
|
{'device': raid_device, 'uuid': md_uuid})
|
|
|
|
component_devices = []
|
|
block_devices = list_all_block_devices()
|
|
block_devices.extend(list_all_block_devices(block_type='part',
|
|
ignore_raid=True))
|
|
for bdev in block_devices:
|
|
try:
|
|
out, _ = il_utils.execute('mdadm', '--examine', bdev.name,
|
|
use_standard_locale=True)
|
|
except processutils.ProcessExecutionError as e:
|
|
if "No md superblock detected" in str(e):
|
|
# actually not a component device
|
|
LOG.debug('Not a component device %s', bdev.name)
|
|
continue
|
|
else:
|
|
LOG.warning("Failed to examine device %(name)s: %(err)s",
|
|
{'name': bdev.name, 'err': e})
|
|
continue
|
|
lines = out.splitlines()
|
|
for line in lines:
|
|
if md_uuid in line:
|
|
component_devices.append(bdev.name)
|
|
|
|
LOG.info('Found component devices for %s: %s',
|
|
raid_device, component_devices)
|
|
return component_devices
|
|
|
|
|
|
def _calc_memory(sys_dict):
|
|
physical = 0
|
|
core_dict = next(utils.find_in_lshw(sys_dict, 'core'), {})
|
|
for core_child in utils.find_in_lshw(core_dict, _MEMORY_ID_RE):
|
|
if core_child.get('size'):
|
|
value = ("%(size)s %(units)s" % core_child)
|
|
physical += int(UNIT_CONVERTER(value).to('MB').magnitude)
|
|
else:
|
|
for bank in core_child.get('children', ()):
|
|
if bank.get('size'):
|
|
value = ("%(size)s %(units)s" % bank)
|
|
physical += int(UNIT_CONVERTER(value).to('MB').magnitude)
|
|
return physical
|
|
|
|
|
|
def get_holder_disks(raid_device):
|
|
"""Get the holder disks of a Software RAID device.
|
|
|
|
Examine an md device and return its underlying disks.
|
|
|
|
:param raid_device: A Software RAID block device name.
|
|
:returns: A list of the holder disks.
|
|
"""
|
|
if not raid_device:
|
|
return []
|
|
|
|
try:
|
|
out, _ = il_utils.execute('mdadm', '--detail', raid_device,
|
|
use_standard_locale=True)
|
|
except processutils.ProcessExecutionError as e:
|
|
LOG.warning('Could not get holder disks of %(dev)s: %(err)s',
|
|
{'dev': raid_device, 'err': e})
|
|
return []
|
|
|
|
holder_disks = []
|
|
lines = out.splitlines()
|
|
# the first line contains the md device itself
|
|
|
|
holder_parts = []
|
|
for line in lines[1:]:
|
|
if 'Events' in line or 'Name' in line:
|
|
continue
|
|
device = re.findall(r'/dev/\w+', line)
|
|
holder_parts += device
|
|
for part in holder_parts:
|
|
# NOTE(mnaser): If the last character is not a digit and it is a valid
|
|
# device, this means that instead of a partition, it's a
|
|
# entire device which is part of this RAID array.
|
|
if (not part[-1].isdigit() and os.path.exists(part)
|
|
and stat.S_ISBLK(os.stat(part).st_mode)):
|
|
holder_disks.append(part)
|
|
continue
|
|
|
|
device = utils.extract_device(part)
|
|
if not device:
|
|
raise errors.SoftwareRAIDError(
|
|
'Could not get holder disks of %s: unexpected pattern '
|
|
'for partition %s' % (raid_device, part))
|
|
holder_disks.append(device)
|
|
|
|
return holder_disks
|
|
|
|
|
|
def is_md_device(raid_device):
|
|
"""Check if a device is an md device
|
|
|
|
Check if a device is a Software RAID (md) device.
|
|
|
|
:param raid_device: A Software RAID block device name.
|
|
:returns: True if the device is an md device, False otherwise.
|
|
"""
|
|
try:
|
|
il_utils.execute('mdadm', '--detail', raid_device)
|
|
LOG.debug("%s is an md device", raid_device)
|
|
return True
|
|
except FileNotFoundError:
|
|
LOG.debug('mdadm has not been found, assuming %s is not an md device',
|
|
raid_device)
|
|
return False
|
|
except processutils.ProcessExecutionError:
|
|
LOG.debug("%s is not an md device", raid_device)
|
|
return False
|
|
|
|
|
|
def md_restart(raid_device):
|
|
"""Restart an md device
|
|
|
|
Stop and re-assemble a Software RAID (md) device.
|
|
|
|
:param raid_device: A Software RAID block device name.
|
|
:raises: CommandExecutionError in case the restart fails.
|
|
"""
|
|
try:
|
|
LOG.debug('Restarting software RAID device %s', raid_device)
|
|
component_devices = get_component_devices(raid_device)
|
|
il_utils.execute('mdadm', '--stop', raid_device)
|
|
il_utils.execute('mdadm', '--assemble', raid_device,
|
|
*component_devices)
|
|
except processutils.ProcessExecutionError as e:
|
|
error_msg = ('Could not restart md device %(dev)s: %(err)s' %
|
|
{'dev': raid_device, 'err': e})
|
|
LOG.error(error_msg)
|
|
raise errors.CommandExecutionError(error_msg)
|
|
|
|
|
|
def md_get_raid_devices():
|
|
"""Get all discovered Software RAID (md) devices
|
|
|
|
:return: A python dict containing details about the discovered RAID
|
|
devices
|
|
"""
|
|
report = il_utils.execute('mdadm', '--examine', '--scan')[0]
|
|
lines = report.splitlines()
|
|
result = {}
|
|
for line in lines:
|
|
vals = shlex.split(line)
|
|
device = vals[1]
|
|
result[device] = {}
|
|
for key, val in (v.split('=', 1) for v in vals[2:]):
|
|
result[device][key] = val.strip()
|
|
return result
|
|
|
|
|
|
def _md_scan_and_assemble():
|
|
"""Scan all md devices and assemble RAID arrays from them.
|
|
|
|
This call does not fail if no md devices are present.
|
|
"""
|
|
try:
|
|
il_utils.execute('mdadm', '--assemble', '--scan', '--verbose')
|
|
except FileNotFoundError:
|
|
LOG.warning('mdadm has not been found, RAID devices will not be '
|
|
'supported')
|
|
except processutils.ProcessExecutionError:
|
|
LOG.info('No new RAID devices assembled during start-up')
|
|
|
|
|
|
def list_all_block_devices(block_type='disk',
|
|
ignore_raid=False,
|
|
ignore_floppy=True,
|
|
ignore_empty=True,
|
|
ignore_multipath=False):
|
|
"""List all physical block devices
|
|
|
|
The switches we use for lsblk: P for KEY="value" output, b for size output
|
|
in bytes, i to ensure ascii characters only, and o to specify the
|
|
fields/columns we need.
|
|
|
|
Broken out as its own function to facilitate custom hardware managers that
|
|
don't need to subclass GenericHardwareManager.
|
|
|
|
:param block_type: Type of block device to find
|
|
:param ignore_raid: Ignore auto-identified raid devices, example: md0
|
|
Defaults to false as these are generally disk
|
|
devices and should be treated as such if encountered.
|
|
:param ignore_floppy: Ignore floppy disk devices in the block device
|
|
list. By default, these devices are filtered out.
|
|
:param ignore_empty: Whether to ignore disks with size equal 0.
|
|
:param ignore_multipath: Whether to ignore devices backing multipath
|
|
devices. Default is to consider multipath
|
|
devices, if possible.
|
|
:return: A list of BlockDevices
|
|
"""
|
|
|
|
def _is_known_device(existing, new_device_name):
|
|
"""Return true if device name is already known."""
|
|
for known_dev in existing:
|
|
if os.path.join('/dev', new_device_name) == known_dev.name:
|
|
return True
|
|
return False
|
|
|
|
check_multipath = not ignore_multipath and get_multipath_status()
|
|
|
|
_udev_settle()
|
|
|
|
# map device names to /dev/disk/by-path symbolic links that points to it
|
|
|
|
by_path_mapping = {}
|
|
|
|
disk_by_path_dir = '/dev/disk/by-path'
|
|
|
|
try:
|
|
paths = os.listdir(disk_by_path_dir)
|
|
|
|
for path in paths:
|
|
path = os.path.join(disk_by_path_dir, path)
|
|
# Turn possibly relative symbolic link into absolute
|
|
devname = os.path.join(disk_by_path_dir, os.readlink(path))
|
|
devname = os.path.abspath(devname)
|
|
by_path_mapping[devname] = path
|
|
|
|
except OSError as e:
|
|
# NOTE(TheJulia): This is for multipath detection, and will raise
|
|
# some warning logs with unrelated tests.
|
|
LOG.warning("Path %(path)s is inaccessible, /dev/disk/by-path/* "
|
|
"version of block device name is unavailable "
|
|
"Cause: %(error)s", {'path': disk_by_path_dir, 'error': e})
|
|
|
|
columns = utils.LSBLK_COLUMNS
|
|
report = il_utils.execute('lsblk', '-bia', '--json',
|
|
'-o{}'.format(','.join(columns)),
|
|
check_exit_code=[0])[0]
|
|
|
|
try:
|
|
report_json = json.loads(report)
|
|
except json.decoder.JSONDecodeError as ex:
|
|
LOG.error("Unable to decode lsblk output, invalid JSON: %s", ex)
|
|
|
|
context = pyudev.Context()
|
|
devices_raw = report_json['blockdevices']
|
|
# Convert raw json output to something useful for us
|
|
devices = []
|
|
for device_raw in devices_raw:
|
|
# Ignore block types not specified
|
|
devtype = device_raw.get('type')
|
|
|
|
# We already have devices, we should ensure we don't store duplicates.
|
|
if _is_known_device(devices, device_raw.get('kname')):
|
|
LOG.debug('Ignoring already known device %s', device_raw)
|
|
continue
|
|
|
|
# If we collected the RM column, we could consult it for removable
|
|
# media, however USB devices are also flagged as removable media.
|
|
# we have to explicitly do this as floppy disks are type disk.
|
|
if ignore_floppy and str(device_raw.get('kname')).startswith('fd'):
|
|
LOG.debug('Ignoring floppy disk device %s', device_raw)
|
|
continue
|
|
|
|
dev_kname = device_raw.get('kname')
|
|
if check_multipath:
|
|
# Net effect is we ignore base devices, and their base devices
|
|
# to what would be the mapped device name which would not pass the
|
|
# validation, but would otherwise be match-able.
|
|
mpath_parent_dev = _get_multipath_parent_device(dev_kname)
|
|
if mpath_parent_dev:
|
|
LOG.warning(
|
|
"We have identified a multipath device %(device)s, this "
|
|
"is being ignored in favor of %(mpath_device)s and its "
|
|
"related child devices.",
|
|
{'device': dev_kname,
|
|
'mpath_device': mpath_parent_dev})
|
|
continue
|
|
# Search for raid in the reply type, as RAID is a
|
|
# disk device, and we should honor it if is present.
|
|
# Other possible type values, which we skip recording:
|
|
# lvm, part, rom, loop
|
|
|
|
if devtype != block_type:
|
|
if devtype is None or ignore_raid:
|
|
LOG.debug(
|
|
"TYPE did not match. Wanted: %(block_type)s but found: "
|
|
"%(devtype)s (RAID devices are ignored)",
|
|
{'block_type': block_type, 'devtype': devtype})
|
|
continue
|
|
elif ('raid' in devtype
|
|
and block_type in ['raid', 'disk', 'mpath']):
|
|
LOG.debug(
|
|
"TYPE detected to contain 'raid', signifying a "
|
|
"RAID volume. Found: %(device_raw)s",
|
|
{'device_raw': device_raw})
|
|
elif (devtype == 'md'
|
|
and (block_type == 'part'
|
|
or block_type == 'md')):
|
|
# NOTE(dszumski): Partitions on software RAID devices have type
|
|
# 'md'. This may also contain RAID devices in a broken state in
|
|
# rare occasions. See https://review.opendev.org/#/c/670807 for
|
|
# more detail.
|
|
LOG.debug(
|
|
"TYPE detected to contain 'md', signifying a "
|
|
"RAID partition. Found: %(device_raw)s",
|
|
{'device_raw': device_raw})
|
|
elif devtype == 'mpath' and block_type == 'disk':
|
|
LOG.debug(
|
|
"TYPE detected to contain 'mpath', "
|
|
"signifing a device mapper multipath device. "
|
|
"Found: %(device_raw)s",
|
|
{'device_raw': device_raw})
|
|
else:
|
|
LOG.debug(
|
|
"TYPE did not match. Wanted: %(block_type)s but found: "
|
|
"%(device_raw)s (RAID devices are ignored)",
|
|
{'block_type': block_type, 'device_raw': device_raw})
|
|
continue
|
|
|
|
# Ensure all required columns are at least present, even if blank
|
|
missing = set(map(str.lower, columns)) - set(device_raw)
|
|
if missing:
|
|
raise errors.BlockDeviceError(
|
|
'%s must be returned by lsblk.' % ', '.join(sorted(missing)))
|
|
|
|
# NOTE(dtantsur): RAM disks and zRAM devices appear in the output of
|
|
# lsblk as disks, but we cannot do anything useful with them.
|
|
if (device_raw['kname'].startswith('ram')
|
|
or device_raw['kname'].startswith('zram')):
|
|
LOG.debug('Skipping RAM device %s', device_raw)
|
|
continue
|
|
|
|
# NOTE(dtantsur): some hardware represents virtual floppy devices as
|
|
# normal block devices with size 0. Filter them out.
|
|
if ignore_empty and not int(device_raw['size'] or 0):
|
|
LOG.debug('Skipping device %s with zero size', device_raw)
|
|
continue
|
|
|
|
name = os.path.join('/dev', device_raw['kname'])
|
|
|
|
extra = {}
|
|
lsblk_serial = device_raw.get('serial')
|
|
if lsblk_serial:
|
|
extra['serial'] = lsblk_serial
|
|
try:
|
|
udev = pyudev.Devices.from_device_file(context, name)
|
|
except pyudev.DeviceNotFoundByFileError as e:
|
|
LOG.warning("Device %(dev)s is inaccessible, skipping... "
|
|
"Error: %(error)s", {'dev': name, 'error': e})
|
|
except pyudev.DeviceNotFoundByNumberError as e:
|
|
LOG.warning("Device %(dev)s is not supported by pyudev, "
|
|
"skipping... Error: %(error)s",
|
|
{'dev': name, 'error': e})
|
|
else:
|
|
# lsblk serial information is prioritized over
|
|
# udev serial information
|
|
udev_property_mappings = [
|
|
('wwn', 'WWN'),
|
|
('wwn_with_extension', 'WWN_WITH_EXTENSION'),
|
|
('wwn_vendor_extension', 'WWN_VENDOR_EXTENSION')
|
|
]
|
|
# Only check device serial information from udev
|
|
# when lsblk returned None
|
|
if not lsblk_serial:
|
|
udev_property_mappings += [
|
|
('serial', 'SERIAL_SHORT'),
|
|
('serial', 'SERIAL')
|
|
]
|
|
for key, udev_key in udev_property_mappings:
|
|
if key in extra:
|
|
continue
|
|
value = (udev.get(f'ID_{udev_key}')
|
|
or udev.get(f'DM_{udev_key}')) # devicemapper
|
|
if value:
|
|
extra[key] = value
|
|
|
|
# NOTE(lucasagomes): Newer versions of the lsblk tool supports
|
|
# HCTL as a parameter but let's get it from sysfs to avoid breaking
|
|
# old distros.
|
|
try:
|
|
extra['hctl'] = os.listdir(
|
|
'/sys/block/%s/device/scsi_device' % device_raw['kname'])[0]
|
|
except (OSError, IndexError):
|
|
LOG.warning('Could not find the SCSI address (HCTL) for '
|
|
'device %s. Skipping', name)
|
|
|
|
# Not all /dev entries are pointed to from /dev/disk/by-path
|
|
by_path_name = by_path_mapping.get(name)
|
|
|
|
devices.append(BlockDevice(name=name,
|
|
model=device_raw['model'],
|
|
size=int(device_raw['size'] or 0),
|
|
rotational=bool(int(device_raw['rota'])),
|
|
vendor=_get_device_info(device_raw['kname'],
|
|
'block', 'vendor'),
|
|
by_path=by_path_name,
|
|
uuid=device_raw['uuid'],
|
|
partuuid=device_raw['partuuid'],
|
|
**extra))
|
|
return devices
|
|
|
|
|
|
def save_api_client(client=None, timeout=None, interval=None):
|
|
"""Preserves access to the API client for potential later re-use."""
|
|
global API_CLIENT, API_LOOKUP_TIMEOUT, API_LOOKUP_INTERVAL
|
|
|
|
if client and timeout and interval and not API_CLIENT:
|
|
API_CLIENT = client
|
|
API_LOOKUP_TIMEOUT = timeout
|
|
API_LOOKUP_INTERVAL = interval
|
|
|
|
|
|
def update_cached_node():
|
|
"""Attmepts to update the node cache via the API"""
|
|
cached_node = get_cached_node()
|
|
if API_CLIENT:
|
|
LOG.info('Agent is requesting to perform an explicit node cache '
|
|
'update. This is to pickup any changes in the cache '
|
|
'before deployment.')
|
|
try:
|
|
if cached_node is None:
|
|
uuid = None
|
|
else:
|
|
uuid = cached_node['uuid']
|
|
content = API_CLIENT.lookup_node(
|
|
hardware_info=list_hardware_info(use_cache=True),
|
|
timeout=API_LOOKUP_TIMEOUT,
|
|
starting_interval=API_LOOKUP_INTERVAL,
|
|
node_uuid=uuid)
|
|
cache_node(content['node'])
|
|
return content['node']
|
|
except Exception as exc:
|
|
LOG.warning('Failed to update node cache. Error %s', exc)
|
|
return cached_node
|
|
|
|
|
|
class HardwareSupport(object):
|
|
"""Example priorities for hardware managers.
|
|
|
|
Priorities for HardwareManagers are integers, where largest means most
|
|
specific and smallest means most generic. These values are guidelines
|
|
that suggest values that might be returned by calls to
|
|
`evaluate_hardware_support()`. No HardwareManager in mainline IPA will
|
|
ever return a value greater than MAINLINE. Third party hardware managers
|
|
should feel free to return values of SERVICE_PROVIDER or greater to
|
|
distinguish between additional levels of hardware support.
|
|
"""
|
|
NONE = 0
|
|
GENERIC = 1
|
|
MAINLINE = 2
|
|
SERVICE_PROVIDER = 3
|
|
|
|
|
|
class HardwareType(object):
|
|
MAC_ADDRESS = 'mac_address'
|
|
|
|
|
|
class BlockDevice(encoding.SerializableComparable):
|
|
serializable_fields = ('name', 'model', 'size', 'rotational',
|
|
'wwn', 'serial', 'vendor', 'wwn_with_extension',
|
|
'wwn_vendor_extension', 'hctl', 'by_path')
|
|
|
|
def __init__(self, name, model, size, rotational, wwn=None, serial=None,
|
|
vendor=None, wwn_with_extension=None,
|
|
wwn_vendor_extension=None, hctl=None, by_path=None,
|
|
uuid=None, partuuid=None):
|
|
self.name = name
|
|
self.model = model
|
|
self.size = size
|
|
self.rotational = rotational
|
|
self.uuid = uuid
|
|
self.wwn = wwn
|
|
self.serial = serial
|
|
self.vendor = vendor
|
|
self.wwn_with_extension = wwn_with_extension
|
|
self.wwn_vendor_extension = wwn_vendor_extension
|
|
self.hctl = hctl
|
|
self.by_path = by_path
|
|
self.partuuid = partuuid
|
|
|
|
|
|
class NetworkInterface(encoding.SerializableComparable):
|
|
serializable_fields = ('name', 'mac_address', 'ipv4_address',
|
|
'ipv6_address', 'has_carrier', 'lldp',
|
|
'vendor', 'product', 'client_id',
|
|
'biosdevname')
|
|
|
|
def __init__(self, name, mac_addr, ipv4_address=None, ipv6_address=None,
|
|
has_carrier=True, lldp=None, vendor=None, product=None,
|
|
client_id=None, biosdevname=None):
|
|
self.name = name
|
|
self.mac_address = mac_addr
|
|
self.ipv4_address = ipv4_address
|
|
self.ipv6_address = ipv6_address
|
|
self.has_carrier = has_carrier
|
|
self.lldp = lldp
|
|
self.vendor = vendor
|
|
self.product = product
|
|
self.biosdevname = biosdevname
|
|
# client_id is used for InfiniBand only. we calculate the DHCP
|
|
# client identifier Option to allow DHCP to work over InfiniBand.
|
|
# see https://tools.ietf.org/html/rfc4390
|
|
self.client_id = client_id
|
|
|
|
|
|
class CPU(encoding.SerializableComparable):
|
|
serializable_fields = ('model_name', 'frequency', 'count', 'architecture',
|
|
'flags')
|
|
|
|
def __init__(self, model_name, frequency, count, architecture,
|
|
flags=None):
|
|
self.model_name = model_name
|
|
self.frequency = frequency
|
|
self.count = count
|
|
self.architecture = architecture
|
|
self.flags = flags or []
|
|
|
|
|
|
class Memory(encoding.SerializableComparable):
|
|
serializable_fields = ('total', 'physical_mb')
|
|
# physical = total + kernel binary + reserved space
|
|
|
|
def __init__(self, total, physical_mb=None):
|
|
self.total = total
|
|
self.physical_mb = physical_mb
|
|
|
|
|
|
class SystemFirmware(encoding.SerializableComparable):
|
|
serializable_fields = ('vendor', 'version', 'build_date')
|
|
|
|
def __init__(self, vendor, version, build_date):
|
|
self.version = version
|
|
self.build_date = build_date
|
|
self.vendor = vendor
|
|
|
|
|
|
class SystemVendorInfo(encoding.SerializableComparable):
|
|
serializable_fields = ('product_name', 'serial_number', 'manufacturer',
|
|
'firmware')
|
|
|
|
def __init__(self, product_name, serial_number, manufacturer, firmware):
|
|
self.product_name = product_name
|
|
self.serial_number = serial_number
|
|
self.manufacturer = manufacturer
|
|
self.firmware = firmware
|
|
|
|
|
|
class BootInfo(encoding.SerializableComparable):
|
|
serializable_fields = ('current_boot_mode', 'pxe_interface')
|
|
|
|
def __init__(self, current_boot_mode, pxe_interface=None):
|
|
self.current_boot_mode = current_boot_mode
|
|
self.pxe_interface = pxe_interface
|
|
|
|
|
|
class HardwareManager(object, metaclass=abc.ABCMeta):
|
|
@abc.abstractmethod
|
|
def evaluate_hardware_support(self):
|
|
pass
|
|
|
|
def list_network_interfaces(self):
|
|
raise errors.IncompatibleHardwareMethodError
|
|
|
|
def collect_lldp_data(self, interface_names=None):
|
|
raise errors.IncompatibleHardwareMethodError
|
|
|
|
def get_cpus(self):
|
|
raise errors.IncompatibleHardwareMethodError
|
|
|
|
def list_block_devices(self, include_partitions=False):
|
|
"""List physical block devices
|
|
|
|
:param include_partitions: If to include partitions
|
|
:return: A list of BlockDevices
|
|
"""
|
|
raise errors.IncompatibleHardwareMethodError
|
|
|
|
def get_skip_list_from_node(self, node,
|
|
block_devices=None, just_raids=False):
|
|
"""Get the skip block devices list from the node
|
|
|
|
:param block_devices: a list of BlockDevices
|
|
:param just_raids: a boolean to signify that only RAID devices
|
|
are important
|
|
:return: A set of names of devices on the skip list
|
|
"""
|
|
raise errors.IncompatibleHardwareMethodError
|
|
|
|
def list_block_devices_check_skip_list(self, node,
|
|
include_partitions=False):
|
|
"""List physical block devices without the ones listed in
|
|
|
|
properties/skip_block_devices list
|
|
|
|
:param node: A node used to check the skip list
|
|
:param include_partitions: If to include partitions
|
|
:return: A list of BlockDevices
|
|
"""
|
|
raise errors.IncompatibleHardwareMethodError
|
|
|
|
def get_memory(self):
|
|
raise errors.IncompatibleHardwareMethodError
|
|
|
|
def get_os_install_device(self, permit_refresh=False):
|
|
raise errors.IncompatibleHardwareMethodError
|
|
|
|
def get_bmc_address(self):
|
|
raise errors.IncompatibleHardwareMethodError()
|
|
|
|
def get_bmc_mac(self):
|
|
raise errors.IncompatibleHardwareMethodError()
|
|
|
|
def get_bmc_v6address(self):
|
|
raise errors.IncompatibleHardwareMethodError()
|
|
|
|
def get_boot_info(self):
|
|
raise errors.IncompatibleHardwareMethodError()
|
|
|
|
def get_interface_info(self, interface_name):
|
|
raise errors.IncompatibleHardwareMethodError()
|
|
|
|
def generate_tls_certificate(self, ip_address):
|
|
raise errors.IncompatibleHardwareMethodError()
|
|
|
|
def erase_block_device(self, node, block_device):
|
|
"""Attempt to erase a block device.
|
|
|
|
Implementations should detect the type of device and erase it in the
|
|
most appropriate way possible. Generic implementations should support
|
|
common erase mechanisms such as ATA secure erase, or multi-pass random
|
|
writes. Operators with more specific needs should override this method
|
|
in order to detect and handle "interesting" cases, or delegate to the
|
|
parent class to handle generic cases.
|
|
|
|
For example: operators running ACME MagicStore (TM) cards alongside
|
|
standard SSDs might check whether the device is a MagicStore and use a
|
|
proprietary tool to erase that, otherwise call this method on their
|
|
parent class. Upstream submissions of common functionality are
|
|
encouraged.
|
|
|
|
This interface could be called concurrently to speed up erasure, as
|
|
such, it should be implemented in a thread-safe way.
|
|
|
|
:param node: Ironic node object
|
|
:param block_device: a BlockDevice indicating a device to be erased.
|
|
:raises IncompatibleHardwareMethodError: when there is no known way to
|
|
erase the block device
|
|
:raises BlockDeviceEraseError: when there is an error erasing the
|
|
block device
|
|
"""
|
|
raise errors.IncompatibleHardwareMethodError
|
|
|
|
def erase_devices(self, node, ports):
|
|
"""Erase any device that holds user data.
|
|
|
|
By default this will attempt to erase block devices. This method can be
|
|
overridden in an implementation-specific hardware manager in order to
|
|
erase additional hardware, although backwards-compatible upstream
|
|
submissions are encouraged.
|
|
|
|
:param node: Ironic node object
|
|
:param ports: list of Ironic port objects
|
|
:raises: ProtectedDeviceFound if a device has been identified which
|
|
may require manual intervention due to the contents and
|
|
operational risk which exists as it could also be a sign
|
|
of an environmental misconfiguration.
|
|
:return: a dictionary in the form {device.name: erasure output}
|
|
"""
|
|
erase_results = {}
|
|
block_devices = self.list_block_devices_check_skip_list(node)
|
|
if not len(block_devices):
|
|
return {}
|
|
|
|
info = node.get('driver_internal_info', {})
|
|
max_pool_size = info.get('disk_erasure_concurrency', 1)
|
|
|
|
thread_pool = ThreadPool(min(max_pool_size, len(block_devices)))
|
|
for block_device in block_devices:
|
|
params = {'node': node, 'block_device': block_device}
|
|
safety_check_block_device(node, block_device.name)
|
|
erase_results[block_device.name] = thread_pool.apply_async(
|
|
dispatch_to_managers, ('erase_block_device',), params)
|
|
thread_pool.close()
|
|
thread_pool.join()
|
|
|
|
for device_name, result in erase_results.items():
|
|
erase_results[device_name] = result.get()
|
|
|
|
return erase_results
|
|
|
|
def wait_for_disks(self):
|
|
"""Wait for the root disk to appear.
|
|
|
|
Wait for at least one suitable disk to show up or a specific disk
|
|
if any device hint is specified. Otherwise neither inspection
|
|
not deployment have any chances to succeed.
|
|
|
|
"""
|
|
if not CONF.disk_wait_attempts:
|
|
return
|
|
|
|
max_waits = CONF.disk_wait_attempts - 1
|
|
for attempt in range(CONF.disk_wait_attempts):
|
|
try:
|
|
self.get_os_install_device()
|
|
except errors.DeviceNotFound:
|
|
LOG.debug('Still waiting for the root device to appear, '
|
|
'attempt %d of %d', attempt + 1,
|
|
CONF.disk_wait_attempts)
|
|
|
|
if attempt < max_waits:
|
|
time.sleep(CONF.disk_wait_delay)
|
|
else:
|
|
break
|
|
else:
|
|
if max_waits:
|
|
LOG.warning('The root device was not detected in %d seconds',
|
|
CONF.disk_wait_delay * max_waits)
|
|
else:
|
|
LOG.warning('The root device was not detected')
|
|
|
|
def list_hardware_info(self):
|
|
"""Return full hardware inventory as a serializable dict.
|
|
|
|
This inventory is sent to Ironic on lookup and to Inspector on
|
|
inspection.
|
|
|
|
:return: a dictionary representing inventory
|
|
"""
|
|
start = time.time()
|
|
LOG.info('Collecting full inventory')
|
|
# NOTE(dtantsur): don't forget to update docs when extending inventory
|
|
hardware_info = {}
|
|
hardware_info['interfaces'] = self.list_network_interfaces()
|
|
hardware_info['cpu'] = self.get_cpus()
|
|
hardware_info['disks'] = self.list_block_devices()
|
|
hardware_info['memory'] = self.get_memory()
|
|
hardware_info['bmc_address'] = self.get_bmc_address()
|
|
hardware_info['bmc_v6address'] = self.get_bmc_v6address()
|
|
hardware_info['system_vendor'] = self.get_system_vendor_info()
|
|
hardware_info['boot'] = self.get_boot_info()
|
|
hardware_info['hostname'] = netutils.get_hostname()
|
|
|
|
try:
|
|
hardware_info['bmc_mac'] = self.get_bmc_mac()
|
|
except errors.IncompatibleHardwareMethodError:
|
|
# if the hardware manager does not support obtaining the BMC MAC,
|
|
# we simply don't expose it.
|
|
pass
|
|
|
|
LOG.info('Inventory collected in %.2f second(s)', time.time() - start)
|
|
return hardware_info
|
|
|
|
def get_clean_steps(self, node, ports):
|
|
"""Get a list of clean steps with priority.
|
|
|
|
Returns a list of steps. Each step is represented by a dict::
|
|
|
|
{
|
|
'interface': the name of the driver interface that should execute
|
|
the step.
|
|
'step': the HardwareManager function to call.
|
|
'priority': the order steps will be run in. Ironic will sort all
|
|
the clean steps from all the drivers, with the largest
|
|
priority step being run first. If priority is set to 0,
|
|
the step will not be run during cleaning, but may be
|
|
run during zapping.
|
|
'reboot_requested': Whether the agent should request Ironic reboots
|
|
the node via the power driver after the
|
|
operation completes.
|
|
'abortable': Boolean value. Whether the clean step can be
|
|
stopped by the operator or not. Some clean step may
|
|
cause non-reversible damage to a machine if interrupted
|
|
(i.e firmware update), for such steps this parameter
|
|
should be set to False. If no value is set for this
|
|
parameter, Ironic will consider False (non-abortable).
|
|
}
|
|
|
|
|
|
If multiple hardware managers return the same step name, the following
|
|
logic will be used to determine which manager's step "wins":
|
|
|
|
* Keep the step that belongs to HardwareManager with highest
|
|
HardwareSupport (larger int) value.
|
|
* If equal support level, keep the step with the higher defined
|
|
priority (larger int).
|
|
* If equal support level and priority, keep the step associated
|
|
with the HardwareManager whose name comes earlier in the
|
|
alphabet.
|
|
|
|
The steps will be called using `hardware.dispatch_to_managers` and
|
|
handled by the best suited hardware manager. If you need a step to be
|
|
executed by only your hardware manager, ensure it has a unique step
|
|
name.
|
|
|
|
`node` and `ports` can be used by other hardware managers to further
|
|
determine if a clean step is supported for the node.
|
|
|
|
:param node: Ironic node object
|
|
:param ports: list of Ironic port objects
|
|
:return: a list of cleaning steps, where each step is described as a
|
|
dict as defined above
|
|
|
|
"""
|
|
return []
|
|
|
|
def get_deploy_steps(self, node, ports):
|
|
"""Get a list of deploy steps with priority.
|
|
|
|
Returns a list of steps. Each step is represented by a dict::
|
|
|
|
{
|
|
'interface': the name of the driver interface that should execute
|
|
the step.
|
|
'step': the HardwareManager function to call.
|
|
'priority': the order steps will be run in. Ironic will sort all
|
|
the deploy steps from all the drivers, with the largest
|
|
priority step being run first. If priority is set to 0,
|
|
the step will not be run during deployment
|
|
automatically, but may be requested via deploy
|
|
templates.
|
|
'reboot_requested': Whether the agent should request Ironic reboots
|
|
the node via the power driver after the
|
|
operation completes.
|
|
'argsinfo': arguments specification.
|
|
}
|
|
|
|
|
|
If multiple hardware managers return the same step name, the following
|
|
logic will be used to determine which manager's step "wins":
|
|
|
|
* Keep the step that belongs to HardwareManager with highest
|
|
HardwareSupport (larger int) value.
|
|
* If equal support level, keep the step with the higher defined
|
|
priority (larger int).
|
|
* If equal support level and priority, keep the step associated
|
|
with the HardwareManager whose name comes earlier in the
|
|
alphabet.
|
|
|
|
The steps will be called using `hardware.dispatch_to_managers` and
|
|
handled by the best suited hardware manager. If you need a step to be
|
|
executed by only your hardware manager, ensure it has a unique step
|
|
name.
|
|
|
|
`node` and `ports` can be used by other hardware managers to further
|
|
determine if a deploy step is supported for the node.
|
|
|
|
:param node: Ironic node object
|
|
:param ports: list of Ironic port objects
|
|
:return: a list of deploying steps, where each step is described as a
|
|
dict as defined above
|
|
|
|
"""
|
|
return []
|
|
|
|
def get_version(self):
|
|
"""Get a name and version for this hardware manager.
|
|
|
|
In order to avoid errors and make agent upgrades painless, cleaning
|
|
will check the version of all hardware managers during get_clean_steps
|
|
at the beginning of cleaning and before executing each step in the
|
|
agent.
|
|
|
|
The agent isn't aware of the steps being taken before or after via
|
|
out of band steps, so it can never know if a new step is safe to run.
|
|
Therefore, we default to restarting the whole process.
|
|
|
|
:returns: a dictionary with two keys: `name` and
|
|
`version`, where `name` is a string identifying the hardware
|
|
manager and `version` is an arbitrary version string. `name` will
|
|
be a class variable called HARDWARE_MANAGER_NAME, or default to
|
|
the class name and `version` will be a class variable called
|
|
HARDWARE_MANAGER_VERSION or default to '1.0'.
|
|
"""
|
|
return {
|
|
'name': getattr(self, 'HARDWARE_MANAGER_NAME',
|
|
type(self).__name__),
|
|
'version': getattr(self, 'HARDWARE_MANAGER_VERSION', '1.0')
|
|
}
|
|
|
|
def collect_system_logs(self, io_dict, file_list):
|
|
"""Collect logs from the system.
|
|
|
|
Implementations should update `io_dict` and `file_list` with logs
|
|
to send to Ironic and Inspector.
|
|
|
|
:param io_dict: Dictionary mapping file names to binary IO objects
|
|
with corresponding data.
|
|
:param file_list: List of full file paths to include.
|
|
"""
|
|
raise errors.IncompatibleHardwareMethodError()
|
|
|
|
|
|
class GenericHardwareManager(HardwareManager):
|
|
HARDWARE_MANAGER_NAME = 'generic_hardware_manager'
|
|
# 1.1 - Added new clean step called erase_devices_metadata
|
|
HARDWARE_MANAGER_VERSION = '1.1'
|
|
|
|
def __init__(self):
|
|
self.lldp_data = {}
|
|
|
|
def evaluate_hardware_support(self):
|
|
# Do some initialization before we declare ourself ready
|
|
_check_for_iscsi()
|
|
_md_scan_and_assemble()
|
|
_load_ipmi_modules()
|
|
global MULTIPATH_ENABLED
|
|
if MULTIPATH_ENABLED is None:
|
|
MULTIPATH_ENABLED = _enable_multipath()
|
|
|
|
self.wait_for_disks()
|
|
return HardwareSupport.GENERIC
|
|
|
|
def collect_lldp_data(self, interface_names=None):
|
|
"""Collect and convert LLDP info from the node.
|
|
|
|
In order to process the LLDP information later, the raw data needs to
|
|
be converted for serialization purposes.
|
|
|
|
:param interface_names: list of names of node's interfaces.
|
|
:return: a dict, containing the lldp data from every interface.
|
|
"""
|
|
if interface_names is None:
|
|
interface_names = netutils.list_interfaces()
|
|
interface_names = [name for name in interface_names if name != 'lo']
|
|
lldp_data = {}
|
|
try:
|
|
raw_lldp_data = netutils.get_lldp_info(interface_names)
|
|
except Exception:
|
|
# NOTE(sambetts) The get_lldp_info function will log this exception
|
|
# and we don't invalidate any existing data in the cache if we fail
|
|
# to get data to replace it so just return.
|
|
return lldp_data
|
|
for ifname, tlvs in raw_lldp_data.items():
|
|
# NOTE(sambetts) Convert each type-length-value (TLV) value to hex
|
|
# so that it can be serialised safely
|
|
processed_tlvs = []
|
|
for typ, data in tlvs:
|
|
try:
|
|
processed_tlvs.append((typ,
|
|
binascii.hexlify(data).decode()))
|
|
except (binascii.Error, binascii.Incomplete) as e:
|
|
LOG.warning('An error occurred while processing TLV type '
|
|
'%(type)s for interface %(name)s: %(err)s',
|
|
{'type': typ, 'name': ifname, 'err': e})
|
|
lldp_data[ifname] = processed_tlvs
|
|
return lldp_data
|
|
|
|
def _get_lldp_data(self, interface_name):
|
|
if self.lldp_data:
|
|
return self.lldp_data.get(interface_name)
|
|
|
|
def get_interface_info(self, interface_name):
|
|
|
|
mac_addr = netutils.get_mac_addr(interface_name)
|
|
if mac_addr is None:
|
|
raise errors.IncompatibleHardwareMethodError()
|
|
|
|
return NetworkInterface(
|
|
interface_name, mac_addr,
|
|
ipv4_address=self.get_ipv4_addr(interface_name),
|
|
ipv6_address=self.get_ipv6_addr(interface_name),
|
|
has_carrier=netutils.interface_has_carrier(interface_name),
|
|
vendor=_get_device_info(interface_name, 'net', 'vendor'),
|
|
product=_get_device_info(interface_name, 'net', 'device'),
|
|
biosdevname=self.get_bios_given_nic_name(interface_name))
|
|
|
|
def get_ipv4_addr(self, interface_id):
|
|
return netutils.get_ipv4_addr(interface_id)
|
|
|
|
def get_ipv6_addr(self, interface_id):
|
|
"""Get the default IPv6 address assigned to the interface.
|
|
|
|
With different networking environment, the address could be a
|
|
link-local address, ULA or something else.
|
|
"""
|
|
return netutils.get_ipv6_addr(interface_id)
|
|
|
|
def get_bios_given_nic_name(self, interface_name):
|
|
"""Collect the BIOS given NICs name.
|
|
|
|
This function uses the biosdevname utility to collect the BIOS given
|
|
name of network interfaces.
|
|
|
|
The collected data is added to the network interface inventory with an
|
|
extra field named ``biosdevname``.
|
|
|
|
:param interface_name: list of names of node's interfaces.
|
|
:return: the BIOS given NIC name of node's interfaces or default
|
|
as None.
|
|
"""
|
|
global WARN_BIOSDEVNAME_NOT_FOUND
|
|
|
|
if netutils.is_vlan(interface_name):
|
|
LOG.debug('Interface %s is a VLAN, biosdevname not called',
|
|
interface_name)
|
|
return
|
|
|
|
try:
|
|
stdout, _ = il_utils.execute('biosdevname', '-i', interface_name)
|
|
return stdout.rstrip('\n')
|
|
except OSError:
|
|
if not WARN_BIOSDEVNAME_NOT_FOUND:
|
|
LOG.warning("Executable 'biosdevname' not found")
|
|
WARN_BIOSDEVNAME_NOT_FOUND = True
|
|
except processutils.ProcessExecutionError as e:
|
|
# NOTE(alezil) biosdevname returns 4 if running in a
|
|
# virtual machine.
|
|
if e.exit_code == 4:
|
|
LOG.info('The system is a virtual machine, so biosdevname '
|
|
'utility does not provide names for virtual NICs.')
|
|
else:
|
|
LOG.warning('Biosdevname returned exit code %s', e.exit_code)
|
|
|
|
def list_network_interfaces(self):
|
|
iface_names = netutils.list_interfaces()
|
|
|
|
if CONF.collect_lldp:
|
|
self.lldp_data = dispatch_to_managers('collect_lldp_data',
|
|
interface_names=iface_names)
|
|
|
|
network_interfaces_list = []
|
|
for iface_name in iface_names:
|
|
try:
|
|
result = dispatch_to_managers(
|
|
'get_interface_info', interface_name=iface_name)
|
|
except errors.HardwareManagerMethodNotFound:
|
|
LOG.warning('No hardware manager was able to handle '
|
|
'interface %s', iface_name)
|
|
continue
|
|
result.lldp = self._get_lldp_data(iface_name)
|
|
network_interfaces_list.append(result)
|
|
|
|
# If configured, bring up vlan interfaces. If the actual vlans aren't
|
|
# defined they are derived from LLDP data
|
|
if CONF.enable_vlan_interfaces:
|
|
vlan_iface_names = netutils.bring_up_vlan_interfaces(
|
|
network_interfaces_list)
|
|
for vlan_iface_name in vlan_iface_names:
|
|
result = dispatch_to_managers(
|
|
'get_interface_info', interface_name=vlan_iface_name)
|
|
network_interfaces_list.append(result)
|
|
|
|
return network_interfaces_list
|
|
|
|
def get_cpus(self):
|
|
lines = il_utils.execute('lscpu')[0]
|
|
cpu_info = {k.strip().lower(): v.strip() for k, v in
|
|
(line.split(':', 1)
|
|
for line in lines.split('\n')
|
|
if line.strip())}
|
|
# Current CPU frequency can be different from maximum one on modern
|
|
# processors
|
|
freq = cpu_info.get('cpu max mhz', cpu_info.get('cpu mhz'))
|
|
|
|
flags = []
|
|
out = il_utils.try_execute('grep', '-Em1', '^flags', '/proc/cpuinfo')
|
|
if out:
|
|
try:
|
|
# Example output (much longer for a real system):
|
|
# flags : fpu vme de pse
|
|
flags = out[0].strip().split(':', 1)[1].strip().split()
|
|
except (IndexError, ValueError):
|
|
LOG.warning('Malformed CPU flags information: %s', out)
|
|
else:
|
|
LOG.warning('Failed to get CPU flags')
|
|
|
|
return CPU(model_name=cpu_info.get('model name'),
|
|
frequency=freq,
|
|
# this includes hyperthreading cores
|
|
count=int(cpu_info.get('cpu(s)')),
|
|
architecture=cpu_info.get('architecture'),
|
|
flags=flags)
|
|
|
|
def get_memory(self):
|
|
# psutil returns a long, so we force it to an int
|
|
try:
|
|
total = int(psutil.virtual_memory().total)
|
|
except Exception:
|
|
# This is explicitly catching all exceptions. We want to catch any
|
|
# situation where a newly upgraded psutil would fail, and instead
|
|
# print an error instead of blowing up the stack on IPA.
|
|
total = None
|
|
LOG.exception(("Cannot fetch total memory size using psutil "
|
|
"version %s"), psutil.version_info[0])
|
|
try:
|
|
sys_dict = _get_system_lshw_dict()
|
|
except (processutils.ProcessExecutionError, OSError, ValueError) as e:
|
|
LOG.warning('Could not get real physical RAM from lshw: %s', e)
|
|
physical = None
|
|
else:
|
|
physical = _calc_memory(sys_dict)
|
|
|
|
if not physical:
|
|
LOG.warning('Did not find any physical RAM')
|
|
|
|
return Memory(total=total, physical_mb=physical)
|
|
|
|
def list_block_devices(self, include_partitions=False):
|
|
block_devices = list_all_block_devices()
|
|
if include_partitions:
|
|
block_devices.extend(
|
|
list_all_block_devices(block_type='part',
|
|
ignore_raid=True)
|
|
)
|
|
return block_devices
|
|
|
|
def get_skip_list_from_node(self, node,
|
|
block_devices=None, just_raids=False):
|
|
properties = node.get('properties', {})
|
|
skip_list_hints = properties.get("skip_block_devices", [])
|
|
if not skip_list_hints:
|
|
return None
|
|
if just_raids:
|
|
return {d['volume_name'] for d in skip_list_hints
|
|
if 'volume_name' in d}
|
|
if not block_devices:
|
|
return None
|
|
skip_list = set()
|
|
serialized_devs = [dev.serialize() for dev in block_devices]
|
|
for hint in skip_list_hints:
|
|
if 'volume_name' in hint:
|
|
continue
|
|
found_devs = il_utils.find_devices_by_hints(serialized_devs, hint)
|
|
excluded_devs = {dev['name'] for dev in found_devs}
|
|
skipped_devices = excluded_devs.difference(skip_list)
|
|
skip_list = skip_list.union(excluded_devs)
|
|
if skipped_devices:
|
|
LOG.warning("Using hint %(hint)s skipping devices: %(devs)s",
|
|
{'hint': hint, 'devs': ','.join(skipped_devices)})
|
|
return skip_list
|
|
|
|
def list_block_devices_check_skip_list(self, node,
|
|
include_partitions=False):
|
|
block_devices = self.list_block_devices(
|
|
include_partitions=include_partitions)
|
|
skip_list = self.get_skip_list_from_node(
|
|
node, block_devices)
|
|
if skip_list is not None:
|
|
block_devices = [d for d in block_devices
|
|
if d.name not in skip_list]
|
|
return block_devices
|
|
|
|
def get_os_install_device(self, permit_refresh=False):
|
|
cached_node = get_cached_node()
|
|
root_device_hints = None
|
|
if cached_node is not None:
|
|
root_device_hints = (
|
|
cached_node['instance_info'].get('root_device')
|
|
or cached_node['properties'].get('root_device'))
|
|
if permit_refresh and not root_device_hints:
|
|
cached_node = update_cached_node()
|
|
root_device_hints = (
|
|
cached_node['instance_info'].get('root_device')
|
|
or cached_node['properties'].get('root_device'))
|
|
LOG.debug('Looking for a device matching root hints %s',
|
|
root_device_hints)
|
|
block_devices = self.list_block_devices_check_skip_list(
|
|
cached_node)
|
|
else:
|
|
block_devices = self.list_block_devices()
|
|
if not root_device_hints:
|
|
dev_name = utils.guess_root_disk(block_devices).name
|
|
else:
|
|
serialized_devs = [dev.serialize() for dev in block_devices]
|
|
try:
|
|
device = il_utils.match_root_device_hints(serialized_devs,
|
|
root_device_hints)
|
|
except ValueError as e:
|
|
# NOTE(lucasagomes): Just playing on the safe side
|
|
# here, this exception should never be raised because
|
|
# Ironic should validate the root device hints before the
|
|
# deployment starts.
|
|
raise errors.DeviceNotFound(
|
|
'No devices could be found using the root device hints '
|
|
'%(hints)s because they failed to validate. Error: '
|
|
'%(error)s' % {'hints': root_device_hints, 'error': e})
|
|
|
|
if not device:
|
|
raise errors.DeviceNotFound(
|
|
"No suitable device was found for "
|
|
"deployment using these hints %s" % root_device_hints)
|
|
|
|
dev_name = device['name']
|
|
|
|
LOG.info('Picked root device %(dev)s for node %(node)s based on '
|
|
'root device hints %(hints)s',
|
|
{'dev': dev_name, 'hints': root_device_hints,
|
|
'node': cached_node['uuid'] if cached_node else None})
|
|
return dev_name
|
|
|
|
def get_system_vendor_info(self):
|
|
try:
|
|
sys_dict = _get_system_lshw_dict()
|
|
except (processutils.ProcessExecutionError, OSError, ValueError) as e:
|
|
LOG.warning('Could not retrieve vendor info from lshw: %s', e)
|
|
sys_dict = {}
|
|
|
|
core_dict = next(utils.find_in_lshw(sys_dict, 'core'), {})
|
|
fw_dict = next(utils.find_in_lshw(core_dict, 'firmware'), {})
|
|
|
|
firmware = SystemFirmware(vendor=fw_dict.get('vendor', ''),
|
|
version=fw_dict.get('version', ''),
|
|
build_date=fw_dict.get('date', ''))
|
|
return SystemVendorInfo(product_name=sys_dict.get('product', ''),
|
|
serial_number=sys_dict.get('serial', ''),
|
|
manufacturer=sys_dict.get('vendor', ''),
|
|
firmware=firmware)
|
|
|
|
def get_boot_info(self):
|
|
boot_mode = 'uefi' if os.path.isdir('/sys/firmware/efi') else 'bios'
|
|
LOG.debug('The current boot mode is %s', boot_mode)
|
|
pxe_interface = utils.get_agent_params().get('BOOTIF')
|
|
return BootInfo(current_boot_mode=boot_mode,
|
|
pxe_interface=pxe_interface)
|
|
|
|
def erase_block_device(self, node, block_device):
|
|
# Check if the block device is virtual media and skip the device.
|
|
if self._is_virtual_media_device(block_device):
|
|
LOG.info("Skipping erase of virtual media device %s",
|
|
block_device.name)
|
|
return
|
|
if self._is_linux_raid_member(block_device):
|
|
LOG.info("Skipping erase of RAID member device %s",
|
|
block_device.name)
|
|
return
|
|
info = node.get('driver_internal_info', {})
|
|
if self._is_read_only_device(block_device):
|
|
if info.get('agent_erase_skip_read_only', False):
|
|
LOG.info("Skipping erase of read-only device %s",
|
|
block_device.name)
|
|
return
|
|
else:
|
|
msg = ('Failed to invoke erase of device %(device)s '
|
|
'as the device is flagged read-only, and the '
|
|
'conductor has not signaled this is a permitted '
|
|
'case.' % {'device': block_device.name})
|
|
LOG.error(msg)
|
|
raise errors.BlockDeviceEraseError(msg)
|
|
# Note(TheJulia) Use try/except to capture and log the failure
|
|
# and then revert to attempting to shred the volume if enabled.
|
|
try:
|
|
if self._is_nvme(block_device):
|
|
|
|
execute_nvme_erase = info.get(
|
|
'agent_enable_nvme_secure_erase', True)
|
|
if execute_nvme_erase and self._nvme_erase(block_device):
|
|
return
|
|
else:
|
|
execute_secure_erase = info.get(
|
|
'agent_enable_ata_secure_erase', True)
|
|
if execute_secure_erase and self._ata_erase(block_device):
|
|
return
|
|
except errors.BlockDeviceEraseError as e:
|
|
execute_shred = info.get('agent_continue_if_secure_erase_failed')
|
|
|
|
# NOTE(janders) While we are deprecating
|
|
# ``driver_internal_info['agent_continue_if_ata_erase_failed']``
|
|
# names check for both ``agent_continue_if_secure_erase_failed``
|
|
# and ``agent_continue_if_ata_erase_failed``.
|
|
# This is to ensure interoperability between newer Ironic Python
|
|
# Agent images and older Ironic API services.
|
|
# In future releases, 'False' default value needs to be added to
|
|
# the info.get call above and the code below can be removed.
|
|
# If we're dealing with new-IPA and old-API scenario, NVMe secure
|
|
# erase should not be attempted due to absence of
|
|
# ``[deploy]/enable_nvme_secure_erase`` config option so
|
|
# ``agent_continue_if_ata_erase_failed`` is not misleading here
|
|
# as it will only apply to ATA Secure Erase.
|
|
if execute_shred is None:
|
|
execute_shred = info.get('agent_continue_if_ata_erase_failed',
|
|
False)
|
|
|
|
if execute_shred:
|
|
LOG.warning('Failed to invoke secure erase, '
|
|
'falling back to shred: %s', e)
|
|
else:
|
|
msg = ('Failed to invoke secure erase, '
|
|
'fallback to shred is not enabled: %s' % e)
|
|
LOG.error(msg)
|
|
raise errors.IncompatibleHardwareMethodError(msg)
|
|
|
|
if self._shred_block_device(node, block_device):
|
|
return
|
|
|
|
msg = ('Unable to erase block device {}: device is unsupported.'
|
|
).format(block_device.name)
|
|
LOG.error(msg)
|
|
raise errors.IncompatibleHardwareMethodError(msg)
|
|
|
|
def _list_erasable_devices(self, node):
|
|
block_devices = self.list_block_devices_check_skip_list(
|
|
node, include_partitions=True)
|
|
# NOTE(coreywright): Reverse sort by device name so a partition (eg
|
|
# sda1) is processed before it disappears when its associated disk (eg
|
|
# sda) has its partition table erased and the kernel notified.
|
|
block_devices.sort(key=lambda dev: dev.name, reverse=True)
|
|
erasable_devices = []
|
|
for dev in block_devices:
|
|
if self._is_virtual_media_device(dev):
|
|
LOG.info("Skipping erasure of virtual media device %s",
|
|
dev.name)
|
|
continue
|
|
if self._is_linux_raid_member(dev):
|
|
LOG.info("Skipping erasure of RAID member device %s",
|
|
dev.name)
|
|
continue
|
|
if self._is_read_only_device(dev):
|
|
LOG.info("Skipping erasure of read-only device %s",
|
|
dev.name)
|
|
continue
|
|
erasable_devices.append(dev)
|
|
|
|
return erasable_devices
|
|
|
|
def erase_devices_metadata(self, node, ports):
|
|
"""Attempt to erase the disk devices metadata.
|
|
|
|
:param node: Ironic node object
|
|
:param ports: list of Ironic port objects
|
|
:raises BlockDeviceEraseError: when there's an error erasing the
|
|
block device
|
|
:raises: ProtectedDeviceFound if a device has been identified which
|
|
may require manual intervention due to the contents and
|
|
operational risk which exists as it could also be a sign
|
|
of an environmental misconfiguration.
|
|
"""
|
|
erase_errors = {}
|
|
for dev in self._list_erasable_devices(node):
|
|
safety_check_block_device(node, dev.name)
|
|
try:
|
|
disk_utils.destroy_disk_metadata(dev.name, node['uuid'])
|
|
except processutils.ProcessExecutionError as e:
|
|
LOG.error('Failed to erase the metadata on device "%(dev)s". '
|
|
'Error: %(error)s', {'dev': dev.name, 'error': e})
|
|
erase_errors[dev.name] = e
|
|
|
|
if erase_errors:
|
|
excpt_msg = ('Failed to erase the metadata on the device(s): %s' %
|
|
'; '.join(['"%s": %s' % (k, v)
|
|
for k, v in erase_errors.items()]))
|
|
raise errors.BlockDeviceEraseError(excpt_msg)
|
|
|
|
def erase_devices_express(self, node, ports):
|
|
"""Attempt to perform time-optimised disk erasure:
|
|
|
|
for NVMe devices, perform NVMe Secure Erase if supported. For other
|
|
devices, perform metadata erasure
|
|
|
|
:param node: Ironic node object
|
|
:param ports: list of Ironic port objects
|
|
:raises BlockDeviceEraseError: when there's an error erasing the
|
|
block device
|
|
:raises: ProtectedDeviceFound if a device has been identified which
|
|
may require manual intervention due to the contents and
|
|
operational risk which exists as it could also be a sign
|
|
of an environmental misconfiguration.
|
|
"""
|
|
erase_errors = {}
|
|
info = node.get('driver_internal_info', {})
|
|
if not self._list_erasable_devices:
|
|
LOG.debug("No erasable devices have been found.")
|
|
return
|
|
for dev in self._list_erasable_devices(node):
|
|
safety_check_block_device(node, dev.name)
|
|
try:
|
|
if self._is_nvme(dev):
|
|
execute_nvme_erase = info.get(
|
|
'agent_enable_nvme_secure_erase', True)
|
|
if execute_nvme_erase and self._nvme_erase(dev):
|
|
continue
|
|
except errors.BlockDeviceEraseError as e:
|
|
LOG.error('Failed to securely erase device "%(dev)s". '
|
|
'Error: %(error)s, falling back to metadata '
|
|
'clean', {'dev': dev.name, 'error': e})
|
|
secure_erase_error = e
|
|
try:
|
|
disk_utils.destroy_disk_metadata(dev.name, node['uuid'])
|
|
except processutils.ProcessExecutionError as e:
|
|
LOG.error('Failed to erase the metadata on device '
|
|
'"%(dev)s". Error: %(error)s',
|
|
{'dev': dev.name, 'error': e})
|
|
if secure_erase_error:
|
|
erase_errors[dev.name] = (
|
|
"Secure erase failed: %s. "
|
|
"Fallback to metadata erase also failed: %s.",
|
|
secure_erase_error, e)
|
|
else:
|
|
erase_errors[dev.name] = e
|
|
|
|
if erase_errors:
|
|
excpt_msg = ('Failed to conduct an express erase on '
|
|
'the device(s): %s' % '\n'.join('"%s": %s' % item
|
|
for item in
|
|
erase_errors.items()))
|
|
raise errors.BlockDeviceEraseError(excpt_msg)
|
|
|
|
def _find_pstore_mount_point(self):
|
|
"""Find the pstore mount point by scanning /proc/mounts.
|
|
|
|
:returns: The pstore mount if existing, none otherwise.
|
|
"""
|
|
with open("/proc/mounts", "r") as mounts:
|
|
for line in mounts:
|
|
# /proc/mounts format is: "device mountpoint fstype ..."
|
|
m = re.match(r'^pstore (\S+) pstore', line)
|
|
if m:
|
|
return m.group(1)
|
|
|
|
def erase_pstore(self, node, ports):
|
|
"""Attempt to erase the kernel pstore.
|
|
|
|
:param node: Ironic node object
|
|
:param ports: list of Ironic port objects
|
|
"""
|
|
pstore_path = self._find_pstore_mount_point()
|
|
if not pstore_path:
|
|
LOG.debug("No pstore found")
|
|
return
|
|
|
|
LOG.info("Cleaning up pstore in %s", pstore_path)
|
|
for file in os.listdir(pstore_path):
|
|
filepath = os.path.join(pstore_path, file)
|
|
try:
|
|
shutil.rmtree(filepath)
|
|
except OSError:
|
|
os.remove(filepath)
|
|
|
|
def burnin_cpu(self, node, ports):
|
|
"""Burn-in the CPU
|
|
|
|
:param node: Ironic node object
|
|
:param ports: list of Ironic port objects
|
|
"""
|
|
burnin.stress_ng_cpu(node)
|
|
|
|
def burnin_disk(self, node, ports):
|
|
"""Burn-in the disk
|
|
|
|
:param node: Ironic node object
|
|
:param ports: list of Ironic port objects
|
|
"""
|
|
burnin.fio_disk(node)
|
|
|
|
def burnin_memory(self, node, ports):
|
|
"""Burn-in the memory
|
|
|
|
:param node: Ironic node object
|
|
:param ports: list of Ironic port objects
|
|
"""
|
|
burnin.stress_ng_vm(node)
|
|
|
|
def burnin_network(self, node, ports):
|
|
"""Burn-in the network
|
|
|
|
:param node: Ironic node object
|
|
:param ports: list of Ironic port objects
|
|
"""
|
|
burnin.fio_network(node)
|
|
|
|
def _shred_block_device(self, node, block_device):
|
|
"""Erase a block device using shred.
|
|
|
|
:param node: Ironic node info.
|
|
:param block_device: a BlockDevice object to be erased
|
|
:returns: True if the erase succeeds, False if it fails for any reason
|
|
"""
|
|
info = node.get('driver_internal_info', {})
|
|
npasses = info.get('agent_erase_devices_iterations', 1)
|
|
args = ('shred', '--force')
|
|
|
|
if info.get('agent_erase_devices_zeroize', True):
|
|
args += ('--zero', )
|
|
|
|
args += ('--verbose', '--iterations', str(npasses), block_device.name)
|
|
|
|
try:
|
|
il_utils.execute(*args)
|
|
except (processutils.ProcessExecutionError, OSError) as e:
|
|
LOG.error("Erasing block device %(dev)s failed with error %(err)s",
|
|
{'dev': block_device.name, 'err': e})
|
|
return False
|
|
|
|
return True
|
|
|
|
def _is_virtual_media_device(self, block_device):
|
|
"""Check if the block device corresponds to Virtual Media device.
|
|
|
|
:param block_device: a BlockDevice object
|
|
:returns: True if it's a virtual media device, else False
|
|
"""
|
|
vm_device_label = '/dev/disk/by-label/ir-vfd-dev'
|
|
if os.path.exists(vm_device_label):
|
|
link = os.readlink(vm_device_label)
|
|
device = os.path.normpath(os.path.join(os.path.dirname(
|
|
vm_device_label), link))
|
|
if block_device.name == device:
|
|
return True
|
|
return False
|
|
|
|
def _is_linux_raid_member(self, block_device):
|
|
"""Check if a block device is a Linux RAID member.
|
|
|
|
:param block_device: a BlockDevice object
|
|
:returns: True if it's Linux RAID member (or if we do not
|
|
manage to verify), False otherwise.
|
|
"""
|
|
try:
|
|
# Don't use the '--nodeps' of lsblk to also catch the
|
|
# parent device of partitions which are RAID members.
|
|
out, _ = il_utils.execute('lsblk', '--fs', '--noheadings',
|
|
block_device.name)
|
|
except processutils.ProcessExecutionError as e:
|
|
LOG.warning("Could not determine if %(name)s is a RAID member: "
|
|
"%(err)s",
|
|
{'name': block_device.name, "err": e})
|
|
return True
|
|
|
|
return 'linux_raid_member' in out
|
|
|
|
def _is_read_only_device(self, block_device, partition=False):
|
|
"""Check if a block device is read-only.
|
|
|
|
Checks the device read-only flag in order to identify virtual
|
|
and firmware driven devices that block write device access.
|
|
|
|
:param block_device: a BlockDevice object
|
|
:param partition: if True, this device is a partition
|
|
:returns: True if the device is read-only.
|
|
"""
|
|
try:
|
|
dev_name = os.path.basename(block_device.name)
|
|
if partition:
|
|
# Check the base device
|
|
dev_name = dev_name.rstrip(string.digits)
|
|
|
|
with open('/sys/block/%s/ro' % dev_name, 'r') as f:
|
|
flag = f.read().strip()
|
|
if flag == '1':
|
|
return True
|
|
except IOError as e:
|
|
# Check underlying device as the file may exist there
|
|
if (not partition and dev_name[-1].isdigit()
|
|
and 'nvme' not in dev_name):
|
|
return self._is_read_only_device(block_device, partition=True)
|
|
|
|
LOG.warning("Could not determine if %(name)s is a"
|
|
"read-only device. Error: %(err)s",
|
|
{'name': block_device.name, 'err': e})
|
|
return False
|
|
|
|
def _get_ata_security_lines(self, block_device):
|
|
output = il_utils.execute('hdparm', '-I', block_device.name)[0]
|
|
|
|
if '\nSecurity: ' not in output:
|
|
return []
|
|
|
|
# Get all lines after the 'Security: ' line
|
|
security_and_beyond = output.split('\nSecurity: \n')[1]
|
|
security_and_beyond_lines = security_and_beyond.split('\n')
|
|
|
|
security_lines = []
|
|
for line in security_and_beyond_lines:
|
|
if line.startswith('\t'):
|
|
security_lines.append(line.strip().replace('\t', ' '))
|
|
else:
|
|
break
|
|
|
|
return security_lines
|
|
|
|
def _smartctl_security_check(self, block_device):
|
|
"""Checks if we can query security via smartctl.
|
|
|
|
:param block_device: A block_device object
|
|
|
|
:returns: True if we can query the block device via ATA
|
|
or the smartctl binary is not present.
|
|
False if we cannot query the device.
|
|
"""
|
|
try:
|
|
# NOTE(TheJulia): smartctl has a concept of drivers being how
|
|
# to query or interpret data from the device. We want to use `ata`
|
|
# instead of `scsi` or `sat` as smartctl will not be able to read
|
|
# a bridged device that it doesn't understand, and accordingly
|
|
# return an error code.
|
|
output = il_utils.execute('smartctl', '-d', 'ata',
|
|
block_device.name, '-g', 'security',
|
|
check_exit_code=[0, 127])[0]
|
|
if 'Unavailable' in output:
|
|
# Smartctl is reporting it is unavailable, lets return false.
|
|
LOG.debug('Smartctl has reported that security is '
|
|
'unavailable on device %s.', block_device.name)
|
|
return False
|
|
return True
|
|
except processutils.ProcessExecutionError:
|
|
# Things don't look so good....
|
|
LOG.warning('Refusing to permit ATA Secure Erase as direct '
|
|
'ATA commands via the `smartctl` utility with device '
|
|
'%s do not succeed.', block_device.name)
|
|
return False
|
|
except OSError as e:
|
|
# Processutils can raise OSError if a path is not found,
|
|
# and it is okay that we tollerate that since it was the
|
|
# prior behavior.
|
|
LOG.warning('Unable to execute `smartctl` utility: %s', e)
|
|
return True
|
|
|
|
def _ata_erase(self, block_device):
|
|
|
|
def __attempt_unlock_drive(block_device, security_lines=None):
|
|
# Attempt to unlock the drive in the event it has already been
|
|
# locked by a previous failed attempt. We try the empty string as
|
|
# versions of hdparm < 9.51, interpreted NULL as the literal
|
|
# string, "NULL", as opposed to the empty string.
|
|
if not security_lines:
|
|
security_lines = self._get_ata_security_lines(block_device)
|
|
unlock_passwords = ['NULL', '']
|
|
for password in unlock_passwords:
|
|
if 'not locked' in security_lines:
|
|
break
|
|
try:
|
|
il_utils.execute('hdparm', '--user-master', 'u',
|
|
'--security-unlock', password,
|
|
block_device.name)
|
|
except processutils.ProcessExecutionError as e:
|
|
LOG.info('Security unlock failed for device '
|
|
'%(name)s using password "%(password)s": %(err)s',
|
|
{'name': block_device.name,
|
|
'password': password,
|
|
'err': e})
|
|
security_lines = self._get_ata_security_lines(block_device)
|
|
return security_lines
|
|
|
|
security_lines = self._get_ata_security_lines(block_device)
|
|
|
|
# If secure erase isn't supported return False so erase_block_device
|
|
# can try another mechanism. Below here, if secure erase is supported
|
|
# but fails in some way, error out (operators of hardware that supports
|
|
# secure erase presumably expect this to work).
|
|
if (not self._smartctl_security_check(block_device)
|
|
or 'supported' not in security_lines):
|
|
return False
|
|
|
|
# At this point, we could be SEC1,2,4,5,6
|
|
|
|
if 'not frozen' not in security_lines:
|
|
# In SEC2 or 6
|
|
raise errors.BlockDeviceEraseError(
|
|
('Block device {} is frozen and cannot be erased'
|
|
).format(block_device.name))
|
|
|
|
# At this point, we could be in SEC1,4,5
|
|
# Attempt to unlock the drive if it has failed in a prior attempt.
|
|
security_lines = __attempt_unlock_drive(block_device, security_lines)
|
|
|
|
# If the unlock failed we will still be in SEC4, otherwise, we will be
|
|
# in SEC1 or SEC5
|
|
|
|
if 'not locked' not in security_lines:
|
|
# In SEC4
|
|
raise errors.BlockDeviceEraseError(
|
|
('Block device {} already has a security password set'
|
|
).format(block_device.name))
|
|
|
|
# At this point, we could be in SEC1 or 5
|
|
if 'not enabled' in security_lines:
|
|
# SEC1. Try to transition to SEC5 by setting empty user
|
|
# password.
|
|
try:
|
|
il_utils.execute('hdparm', '--user-master', 'u',
|
|
'--security-set-pass', 'NULL',
|
|
block_device.name)
|
|
except processutils.ProcessExecutionError as e:
|
|
error_msg = ('Security password set failed for device '
|
|
'{name}: {err}'
|
|
).format(name=block_device.name, err=e)
|
|
raise errors.BlockDeviceEraseError(error_msg)
|
|
|
|
# Use the 'enhanced' security erase option if it's supported.
|
|
erase_option = '--security-erase'
|
|
if 'not supported: enhanced erase' not in security_lines:
|
|
erase_option += '-enhanced'
|
|
|
|
try:
|
|
il_utils.execute('hdparm', '--user-master', 'u', erase_option,
|
|
'NULL', block_device.name)
|
|
except processutils.ProcessExecutionError as e:
|
|
# NOTE(TheJulia): Attempt unlock to allow fallback to shred
|
|
# to occur, otherwise shred will fail as well, as the security
|
|
# mode will prevent IO operations to the disk.
|
|
__attempt_unlock_drive(block_device)
|
|
raise errors.BlockDeviceEraseError('Erase failed for device '
|
|
'%(name)s: %(err)s' %
|
|
{'name': block_device.name,
|
|
'err': e})
|
|
|
|
# Verify that security is now 'not enabled'
|
|
security_lines = self._get_ata_security_lines(block_device)
|
|
if 'not enabled' not in security_lines:
|
|
# Not SEC1 - fail
|
|
raise errors.BlockDeviceEraseError(
|
|
('An unknown error occurred erasing block device {}'
|
|
).format(block_device.name))
|
|
|
|
# In SEC1 security state
|
|
return True
|
|
|
|
def _is_nvme(self, block_device):
|
|
"""Check if a block device is a NVMe.
|
|
|
|
Checks if the device name indicates that it is an NVMe drive.
|
|
|
|
:param block_device: a BlockDevice object
|
|
:returns: True if the device is an NVMe, False if it is not.
|
|
"""
|
|
|
|
return block_device.name.startswith("/dev/nvme")
|
|
|
|
def _nvme_erase(self, block_device):
|
|
"""Attempt to clean the NVMe using the most secure supported method
|
|
|
|
:param block_device: a BlockDevice object
|
|
:return: True if cleaning operation succeeded, False if it failed
|
|
:raises: BlockDeviceEraseError
|
|
"""
|
|
|
|
# check if crypto format is supported
|
|
try:
|
|
LOG.debug("Attempting to fetch NVMe capabilities for device %s",
|
|
block_device.name)
|
|
nvme_info, _e = il_utils.execute('nvme', 'id-ctrl',
|
|
block_device.name, '-o', 'json')
|
|
nvme_info = json.loads(nvme_info)
|
|
|
|
except processutils.ProcessExecutionError as e:
|
|
msg = (("Failed to fetch NVMe capabilities for device {}: {}")
|
|
.format(block_device, e))
|
|
LOG.error(msg)
|
|
raise errors.BlockDeviceEraseError(msg)
|
|
|
|
# execute format with crypto option (ses=2) if supported
|
|
# if crypto is unsupported use user-data erase (ses=1)
|
|
if nvme_info:
|
|
# Check if the device supports NVMe format at all. This info
|
|
# is in "oacs" section of nvme-cli id-ctrl output. If it does,
|
|
# set format mode to 1 (this is passed as -s <mode> parameter
|
|
# to nvme-cli later)
|
|
fmt_caps = nvme_info['oacs']
|
|
if fmt_caps & NVME_CLI_FORMAT_SUPPORTED_FLAG:
|
|
# Given the device supports format, check if crypto
|
|
# erase format mode is supported and pass it to nvme-cli
|
|
# instead
|
|
crypto_caps = nvme_info['fna']
|
|
if crypto_caps & NVME_CLI_CRYPTO_FORMAT_SUPPORTED_FLAG:
|
|
format_mode = 2 # crypto erase
|
|
else:
|
|
format_mode = 1 # user-data erase
|
|
else:
|
|
msg = ('nvme-cli did not return any supported format modes '
|
|
'for device: {device}').format(
|
|
device=block_device.name)
|
|
LOG.error(msg)
|
|
raise errors.BlockDeviceEraseError(msg)
|
|
else:
|
|
# If nvme-cli output is empty, raise an exception
|
|
msg = ('nvme-cli did not return any information '
|
|
'for device: {device}').format(device=block_device.name)
|
|
LOG.error(msg)
|
|
raise errors.BlockDeviceEraseError(msg)
|
|
|
|
try:
|
|
LOG.debug("Attempting to nvme-format %s using secure format mode "
|
|
"(ses) %s", block_device.name, format_mode)
|
|
il_utils.execute('nvme', 'format', block_device.name, '-s',
|
|
format_mode, '-f')
|
|
LOG.info("nvme-cli format for device %s (ses= %s ) completed "
|
|
"successfully.", block_device.name, format_mode)
|
|
return True
|
|
|
|
except processutils.ProcessExecutionError as e:
|
|
msg = (("Failed to nvme format device {}: {}"
|
|
).format(block_device, e))
|
|
raise errors.BlockDeviceEraseError(msg)
|
|
|
|
def get_bmc_address(self):
|
|
"""Attempt to detect BMC IP address
|
|
|
|
:return: IP address of lan channel or 0.0.0.0 in case none of them is
|
|
configured properly
|
|
"""
|
|
try:
|
|
# From all the channels 0-15, only 1-11 can be assigned to
|
|
# different types of communication media and protocols and
|
|
# effectively used
|
|
for channel in range(1, 12):
|
|
out, e = il_utils.execute(
|
|
"ipmitool lan print {} | awk '/IP Address[ \\t]*:/"
|
|
" {{print $4}}'".format(channel), shell=True)
|
|
if e.startswith("Invalid channel"):
|
|
continue
|
|
out = out.strip()
|
|
|
|
try:
|
|
ipaddress.ip_address(out)
|
|
except ValueError as exc:
|
|
LOG.warning('Invalid IP address %(output)s: %(exc)s',
|
|
{'output': out, 'exc': exc})
|
|
continue
|
|
|
|
# In case we get 0.0.0.0 on a valid channel, we need to keep
|
|
# querying
|
|
if out != '0.0.0.0':
|
|
return out
|
|
|
|
except (processutils.ProcessExecutionError, OSError) as e:
|
|
# Not error, because it's normal in virtual environment
|
|
LOG.warning("Cannot get BMC address: %s", e)
|
|
return
|
|
|
|
return '0.0.0.0'
|
|
|
|
def get_bmc_mac(self):
|
|
"""Attempt to detect BMC MAC address
|
|
|
|
:return: MAC address of the first LAN channel or 00:00:00:00:00:00 in
|
|
case none of them has one or is configured properly
|
|
"""
|
|
try:
|
|
# From all the channels 0-15, only 1-11 can be assigned to
|
|
# different types of communication media and protocols and
|
|
# effectively used
|
|
for channel in range(1, 12):
|
|
out, e = il_utils.execute(
|
|
"ipmitool lan print {} | awk '/(IP|MAC) Address[ \\t]*:/"
|
|
" {{print $4}}'".format(channel), shell=True)
|
|
if e.startswith("Invalid channel"):
|
|
continue
|
|
|
|
try:
|
|
ip, mac = out.strip().split("\n")
|
|
except ValueError:
|
|
LOG.warning('Invalid ipmitool output %(output)s',
|
|
{'output': out})
|
|
continue
|
|
|
|
if ip == "0.0.0.0":
|
|
# disabled, ignore
|
|
continue
|
|
|
|
if not re.match("^[0-9a-f]{2}(:[0-9a-f]{2}){5}$", mac, re.I):
|
|
LOG.warning('Invalid MAC address %(output)s',
|
|
{'output': mac})
|
|
continue
|
|
|
|
# In case we get 00:00:00:00:00:00 on a valid channel, we need
|
|
# to keep querying
|
|
if mac != '00:00:00:00:00:00':
|
|
return mac
|
|
|
|
except (processutils.ProcessExecutionError, OSError) as e:
|
|
# Not error, because it's normal in virtual environment
|
|
LOG.warning("Cannot get BMC MAC address: %s", e)
|
|
return
|
|
|
|
# no valid mac found, signal this clearly
|
|
raise errors.IncompatibleHardwareMethodError()
|
|
|
|
def get_bmc_v6address(self):
|
|
"""Attempt to detect BMC v6 address
|
|
|
|
:return: IPv6 address of lan channel or ::/0 in case none of them is
|
|
configured properly. May return None value if it cannot
|
|
interract with system tools or critical error occurs.
|
|
"""
|
|
null_address_re = re.compile(r'^::(/\d{1,3})*$')
|
|
|
|
def get_addr(channel, dynamic=False):
|
|
cmd = "ipmitool lan6 print {} {}_addr".format(
|
|
channel, 'dynamic' if dynamic else 'static')
|
|
try:
|
|
out, exc = il_utils.execute(cmd, shell=True)
|
|
except processutils.ProcessExecutionError:
|
|
return
|
|
|
|
# NOTE: More likely ipmitool was not intended to return
|
|
# stdout in yaml format. Fortunately, output of
|
|
# dynamic_addr and static_addr commands is a valid yaml.
|
|
try:
|
|
out = yaml.safe_load(out.strip())
|
|
except yaml.YAMLError as excpt:
|
|
LOG.warning('Cannot process output of "%(cmd)s" '
|
|
'command: %(e)s', {'cmd': cmd, 'e': excpt})
|
|
return
|
|
|
|
for addr_dict in out.values():
|
|
address = addr_dict['Address']
|
|
if dynamic:
|
|
enabled = addr_dict['Source/Type'] in ['DHCPv6', 'SLAAC']
|
|
else:
|
|
enabled = addr_dict['Enabled']
|
|
|
|
if addr_dict['Status'] == 'active' and enabled \
|
|
and not null_address_re.match(address):
|
|
return address
|
|
|
|
try:
|
|
# From all the channels 0-15, only 1-11 can be assigned to
|
|
# different types of communication media and protocols and
|
|
# effectively used
|
|
for channel in range(1, 12):
|
|
addr_mode, e = il_utils.execute(
|
|
r"ipmitool lan6 print {} enables | "
|
|
r"awk '/IPv6\/IPv4 Addressing Enables[ \t]*:/"
|
|
r"{{print $NF}}'".format(channel), shell=True)
|
|
if addr_mode.strip() not in ['ipv6', 'both']:
|
|
continue
|
|
|
|
address = get_addr(channel, dynamic=True) or get_addr(channel)
|
|
if not address:
|
|
continue
|
|
|
|
try:
|
|
return str(ipaddress.ip_interface(address).ip)
|
|
except ValueError as exc:
|
|
LOG.warning('Invalid IP address %(addr)s: %(exception)s',
|
|
{'addr': address, 'exception': exc})
|
|
continue
|
|
except (processutils.ProcessExecutionError, OSError) as exc:
|
|
# Not error, because it's normal in virtual environment
|
|
LOG.warning("Cannot get BMC v6 address: %s", exc)
|
|
return
|
|
|
|
return '::/0'
|
|
|
|
def get_clean_steps(self, node, ports):
|
|
return [
|
|
{
|
|
'step': 'erase_devices',
|
|
'priority': 10,
|
|
'interface': 'deploy',
|
|
'reboot_requested': False,
|
|
'abortable': True
|
|
},
|
|
{
|
|
'step': 'erase_devices_metadata',
|
|
'priority': 99,
|
|
'interface': 'deploy',
|
|
'reboot_requested': False,
|
|
'abortable': True
|
|
},
|
|
{
|
|
'step': 'erase_devices_express',
|
|
'priority': 0,
|
|
'interface': 'deploy',
|
|
'reboot_requested': False,
|
|
'abortable': True
|
|
},
|
|
{
|
|
'step': 'erase_pstore',
|
|
'priority': 0,
|
|
'interface': 'deploy',
|
|
'reboot_requested': False,
|
|
'abortable': True
|
|
},
|
|
{
|
|
'step': 'delete_configuration',
|
|
'priority': 0,
|
|
'interface': 'raid',
|
|
'reboot_requested': False,
|
|
'abortable': True
|
|
},
|
|
{
|
|
'step': 'create_configuration',
|
|
'priority': 0,
|
|
'interface': 'raid',
|
|
'reboot_requested': False,
|
|
'abortable': True
|
|
},
|
|
{
|
|
'step': 'burnin_cpu',
|
|
'priority': 0,
|
|
'interface': 'deploy',
|
|
'reboot_requested': False,
|
|
'abortable': True
|
|
},
|
|
{
|
|
'step': 'burnin_disk',
|
|
'priority': 0,
|
|
'interface': 'deploy',
|
|
'reboot_requested': False,
|
|
'abortable': True
|
|
},
|
|
{
|
|
'step': 'burnin_memory',
|
|
'priority': 0,
|
|
'interface': 'deploy',
|
|
'reboot_requested': False,
|
|
'abortable': True
|
|
},
|
|
{
|
|
'step': 'burnin_network',
|
|
'priority': 0,
|
|
'interface': 'deploy',
|
|
'reboot_requested': False,
|
|
'abortable': True
|
|
},
|
|
]
|
|
|
|
def get_deploy_steps(self, node, ports):
|
|
return [
|
|
{
|
|
'step': 'erase_devices_metadata',
|
|
'priority': 0,
|
|
'interface': 'deploy',
|
|
'reboot_requested': False,
|
|
},
|
|
{
|
|
'step': 'apply_configuration',
|
|
'priority': 0,
|
|
'interface': 'raid',
|
|
'reboot_requested': False,
|
|
'argsinfo': RAID_APPLY_CONFIGURATION_ARGSINFO,
|
|
},
|
|
{
|
|
'step': 'write_image',
|
|
# NOTE(dtantsur): this step has to be proxied via an
|
|
# out-of-band step with the same name, hence the priority here
|
|
# doesn't really matter.
|
|
'priority': 0,
|
|
'interface': 'deploy',
|
|
'reboot_requested': False,
|
|
},
|
|
{
|
|
'step': 'inject_files',
|
|
'priority': CONF.inject_files_priority,
|
|
'interface': 'deploy',
|
|
'reboot_requested': False,
|
|
'argsinfo': inject_files.ARGSINFO,
|
|
},
|
|
]
|
|
|
|
def apply_configuration(self, node, ports, raid_config,
|
|
delete_existing=True):
|
|
"""Apply RAID configuration.
|
|
|
|
:param node: A dictionary of the node object.
|
|
:param ports: A list of dictionaries containing information
|
|
of ports for the node.
|
|
:param raid_config: The configuration to apply.
|
|
:param delete_existing: Whether to delete the existing configuration.
|
|
"""
|
|
self.validate_configuration(raid_config, node)
|
|
if delete_existing:
|
|
self.delete_configuration(node, ports)
|
|
return self._do_create_configuration(node, ports, raid_config)
|
|
|
|
def create_configuration(self, node, ports):
|
|
"""Create a RAID configuration.
|
|
|
|
Unless overwritten by a local hardware manager, this method
|
|
will create a software RAID configuration as read from the
|
|
node's 'target_raid_config'.
|
|
|
|
:param node: A dictionary of the node object.
|
|
:param ports: A list of dictionaries containing information
|
|
of ports for the node.
|
|
:returns: The current RAID configuration in the usual format.
|
|
:raises: SoftwareRAIDError if the desired configuration is not
|
|
valid or if there was an error when creating the RAID
|
|
devices.
|
|
"""
|
|
raid_config = node.get('target_raid_config', {})
|
|
if not raid_config:
|
|
LOG.debug("No target_raid_config found")
|
|
return {}
|
|
|
|
return self._do_create_configuration(node, ports, raid_config)
|
|
|
|
def _do_create_configuration(self, node, ports, raid_config):
|
|
def _get_volume_names_of_existing_raids():
|
|
list_of_raids = []
|
|
raid_devices = list_all_block_devices(block_type='raid',
|
|
ignore_raid=False,
|
|
ignore_empty=False)
|
|
raid_devices.extend(
|
|
list_all_block_devices(block_type='md',
|
|
ignore_raid=False,
|
|
ignore_empty=False)
|
|
)
|
|
for raid_device in raid_devices:
|
|
device = raid_device.name
|
|
try:
|
|
il_utils.execute('mdadm', '--examine',
|
|
device, use_standard_locale=True)
|
|
except processutils.ProcessExecutionError as e:
|
|
if "No md superblock detected" in str(e):
|
|
continue
|
|
volume_name = raid_utils.get_volume_name_of_raid_device(device)
|
|
if volume_name:
|
|
list_of_raids.append(volume_name)
|
|
else:
|
|
list_of_raids.append("unnamed_raid")
|
|
return list_of_raids
|
|
|
|
# No 'software' controller: do nothing. If 'controller' is
|
|
# set to 'software' on only one of the drives, the validation
|
|
# code will catch it.
|
|
software_raid = False
|
|
logical_disks = raid_config.get('logical_disks')
|
|
software_raid_disks = []
|
|
for logical_disk in logical_disks:
|
|
if logical_disk.get('controller') == 'software':
|
|
software_raid = True
|
|
software_raid_disks.append(logical_disk)
|
|
if not software_raid:
|
|
LOG.debug("No Software RAID config found")
|
|
return {}
|
|
|
|
LOG.info("Creating Software RAID")
|
|
|
|
# Check if the config is compliant with current limitations.
|
|
self.validate_configuration(raid_config, node)
|
|
|
|
# Remove any logical disk from being eligible for inclusion in the
|
|
# RAID if it's on the skip list
|
|
skip_list = self.get_skip_list_from_node(
|
|
node, just_raids=True)
|
|
rm_from_list = []
|
|
if skip_list:
|
|
present_raids = _get_volume_names_of_existing_raids()
|
|
if present_raids:
|
|
for ld in logical_disks:
|
|
volume_name = ld.get('volume_name', None)
|
|
if volume_name in skip_list \
|
|
and volume_name in present_raids:
|
|
rm_from_list.append(ld)
|
|
LOG.debug("Software RAID device with volume name %s "
|
|
"exists and is, therefore, not going to be "
|
|
"created", volume_name)
|
|
present_raids.remove(volume_name)
|
|
# NOTE(kubajj): Raise an error if there is an existing software
|
|
# RAID device that either does not have a volume name or does not
|
|
# match one on the skip list
|
|
if present_raids:
|
|
msg = ("Existing Software RAID device detected that should"
|
|
" not")
|
|
raise errors.SoftwareRAIDError(msg)
|
|
logical_disks = [d for d in logical_disks if d not in rm_from_list]
|
|
|
|
# Log the validated target_raid_configuration.
|
|
LOG.debug("Target Software RAID configuration: %s", raid_config)
|
|
|
|
block_devices, logical_disks = raid_utils.get_block_devices_for_raid(
|
|
self.list_block_devices(), logical_disks)
|
|
if not rm_from_list:
|
|
# Make sure there are no partitions yet (or left behind).
|
|
with_parts = []
|
|
for dev_name in block_devices:
|
|
try:
|
|
if disk_utils.list_partitions(dev_name):
|
|
with_parts.append(dev_name)
|
|
except processutils.ProcessExecutionError:
|
|
# Presumably no partitions (or no partition table)
|
|
continue
|
|
if with_parts:
|
|
msg = ("Partitions detected on devices %s during RAID config" %
|
|
', '.join(with_parts))
|
|
raise errors.SoftwareRAIDError(msg)
|
|
|
|
partition_table_type = utils.get_partition_table_type_from_specs(node)
|
|
target_boot_mode = utils.get_node_boot_mode(node)
|
|
|
|
parted_start_dict = raid_utils.create_raid_partition_tables(
|
|
block_devices, partition_table_type, target_boot_mode)
|
|
|
|
LOG.debug("First available sectors per devices %s", parted_start_dict)
|
|
|
|
# Reorder logical disks so that MAX comes last if any:
|
|
reordered_logical_disks = []
|
|
max_disk = None
|
|
for logical_disk in logical_disks:
|
|
psize = logical_disk['size_gb']
|
|
if psize == 'MAX':
|
|
max_disk = logical_disk
|
|
else:
|
|
reordered_logical_disks.append(logical_disk)
|
|
if max_disk:
|
|
reordered_logical_disks.append(max_disk)
|
|
logical_disks = reordered_logical_disks
|
|
|
|
# With the partitioning below, the first partition is not
|
|
# exactly the size_gb provided, but rather the size minus a small
|
|
# amount (often 2048*512B=1MiB, depending on the disk geometry).
|
|
# Easier to ignore. Another way could be to use sgdisk, which is really
|
|
# user-friendly to compute part boundaries automatically, instead of
|
|
# parted, then convert back to mbr table if needed and possible.
|
|
|
|
for logical_disk in logical_disks:
|
|
# Note: from the doc,
|
|
# https://docs.openstack.org/ironic/latest/admin/raid.html#target-raid-configuration
|
|
# size_gb unit is GiB
|
|
|
|
psize = logical_disk['size_gb']
|
|
if psize == 'MAX':
|
|
psize = -1
|
|
else:
|
|
psize = int(psize)
|
|
|
|
# NOTE(dtantsur): populated in get_block_devices_for_raid
|
|
disk_names = logical_disk['block_devices']
|
|
for device in disk_names:
|
|
start = parted_start_dict[device]
|
|
start_str, end_str, end = (
|
|
raid_utils.calc_raid_partition_sectors(psize, start)
|
|
)
|
|
try:
|
|
LOG.debug("Creating partition on %(dev)s: %(str)s %(end)s",
|
|
{'dev': device, 'str': start_str,
|
|
'end': end_str})
|
|
|
|
il_utils.execute('parted', device, '-s', '-a',
|
|
'optimal', '--', 'mkpart', 'primary',
|
|
start_str, end_str)
|
|
|
|
except processutils.ProcessExecutionError as e:
|
|
msg = "Failed to create partitions on {}: {}".format(
|
|
device, e)
|
|
raise errors.SoftwareRAIDError(msg)
|
|
|
|
utils.rescan_device(device)
|
|
|
|
parted_start_dict[device] = end
|
|
|
|
# Create the RAID devices.
|
|
for index, logical_disk in enumerate(logical_disks):
|
|
raid_utils.create_raid_device(index, logical_disk)
|
|
|
|
LOG.info("Successfully created Software RAID")
|
|
|
|
return raid_config
|
|
|
|
def delete_configuration(self, node, ports):
|
|
"""Delete a RAID configuration.
|
|
|
|
Unless overwritten by a local hardware manager, this method
|
|
will delete all software RAID devices on the node.
|
|
NOTE(arne_wiebalck): It may be worth considering to only
|
|
delete RAID devices in the node's 'target_raid_config'. If
|
|
that config has been lost, though, the cleanup may become
|
|
difficult. So, for now, we delete everything we detect.
|
|
|
|
:param node: A dictionary of the node object
|
|
:param ports: A list of dictionaries containing information
|
|
of ports for the node
|
|
"""
|
|
|
|
def _scan_raids():
|
|
il_utils.execute('mdadm', '--assemble', '--scan',
|
|
check_exit_code=False)
|
|
raid_devices = list_all_block_devices(block_type='raid',
|
|
ignore_raid=False,
|
|
ignore_empty=False)
|
|
# NOTE(dszumski): Fetch all devices of type 'md'. This
|
|
# will generally contain partitions on a software RAID
|
|
# device, but crucially may also contain devices in a
|
|
# broken state. See https://review.opendev.org/#/c/670807/
|
|
# for more detail.
|
|
raid_devices.extend(
|
|
list_all_block_devices(block_type='md',
|
|
ignore_raid=False,
|
|
ignore_empty=False)
|
|
)
|
|
return raid_devices
|
|
|
|
raid_devices = _scan_raids()
|
|
skip_list = self.get_skip_list_from_node(
|
|
node, just_raids=True)
|
|
attempts = 0
|
|
while attempts < 2:
|
|
attempts += 1
|
|
self._delete_config_pass(raid_devices, skip_list)
|
|
raid_devices = _scan_raids()
|
|
if not raid_devices:
|
|
break
|
|
else:
|
|
msg = "Unable to clean all softraid correctly. Remaining {}".\
|
|
format([dev.name for dev in raid_devices])
|
|
LOG.error(msg)
|
|
raise errors.SoftwareRAIDError(msg)
|
|
|
|
def _delete_config_pass(self, raid_devices, skip_list):
|
|
all_holder_disks = []
|
|
do_not_delete_devices = set()
|
|
delete_partitions = {}
|
|
for raid_device in raid_devices:
|
|
do_not_delete = False
|
|
volume_name = raid_utils.get_volume_name_of_raid_device(
|
|
raid_device.name)
|
|
if volume_name:
|
|
LOG.info("Software RAID device %(dev)s has volume name"
|
|
"%(name)s", {'dev': raid_device.name,
|
|
'name': volume_name})
|
|
if skip_list and volume_name in skip_list:
|
|
LOG.warning("RAID device %s will not be deleted",
|
|
raid_device.name)
|
|
do_not_delete = True
|
|
component_devices = get_component_devices(raid_device.name)
|
|
if not component_devices:
|
|
# A "Software RAID device" without components is usually
|
|
# a partition on an md device (as, for instance, created
|
|
# by the conductor for the config drive). This will be
|
|
# cleaned with the hosting md device.
|
|
LOG.info("Software RAID cleaning is skipping "
|
|
"partition %s", raid_device.name)
|
|
continue
|
|
holder_disks = get_holder_disks(raid_device.name)
|
|
|
|
if do_not_delete:
|
|
LOG.warning("Software RAID device %(dev)s is not going to be "
|
|
"deleted as its volume name - %(vn)s - is on the "
|
|
"skip list", {'dev': raid_device.name,
|
|
'vn': volume_name})
|
|
else:
|
|
LOG.info("Deleting Software RAID device %s", raid_device.name)
|
|
LOG.debug('Found component devices %s', component_devices)
|
|
LOG.debug('Found holder disks %s', holder_disks)
|
|
|
|
if not do_not_delete:
|
|
# Remove md devices.
|
|
try:
|
|
il_utils.execute('wipefs', '-af', raid_device.name)
|
|
except processutils.ProcessExecutionError as e:
|
|
LOG.warning('Failed to wipefs %(device)s: %(err)s',
|
|
{'device': raid_device.name, 'err': e})
|
|
try:
|
|
il_utils.execute('mdadm', '--stop', raid_device.name)
|
|
except processutils.ProcessExecutionError as e:
|
|
LOG.warning('Failed to stop %(device)s: %(err)s',
|
|
{'device': raid_device.name, 'err': e})
|
|
|
|
# Remove md metadata from component devices.
|
|
for component_device in component_devices:
|
|
try:
|
|
il_utils.execute('mdadm', '--examine',
|
|
component_device,
|
|
use_standard_locale=True)
|
|
except processutils.ProcessExecutionError as e:
|
|
if "No md superblock detected" in str(e):
|
|
# actually not a component device
|
|
continue
|
|
else:
|
|
msg = "Failed to examine device {}: {}".format(
|
|
component_device, e)
|
|
raise errors.SoftwareRAIDError(msg)
|
|
|
|
LOG.debug('Deleting md superblock on %s', component_device)
|
|
try:
|
|
il_utils.execute('mdadm', '--zero-superblock',
|
|
component_device)
|
|
except processutils.ProcessExecutionError as e:
|
|
LOG.warning('Failed to remove superblock from'
|
|
'%(device)s: %(err)s',
|
|
{'device': raid_device.name, 'err': e})
|
|
if skip_list:
|
|
dev, part = utils.split_device_and_partition_number(
|
|
component_device)
|
|
if dev in delete_partitions:
|
|
delete_partitions[dev].append(part)
|
|
else:
|
|
delete_partitions[dev] = [part]
|
|
else:
|
|
for component_device in component_devices:
|
|
do_not_delete_devices.add(component_device)
|
|
|
|
# NOTE(arne_wiebalck): We cannot delete the partitions right
|
|
# away since there may be other partitions on the same disks
|
|
# which are members of other RAID devices. So we remember them
|
|
# for later.
|
|
all_holder_disks.extend(holder_disks)
|
|
if do_not_delete:
|
|
LOG.warning("Software RAID device %s was not deleted",
|
|
raid_device.name)
|
|
else:
|
|
LOG.info('Deleted Software RAID device %s', raid_device.name)
|
|
|
|
# Remove all remaining raid traces from any drives, in case some
|
|
# drives or partitions have been member of some raid once
|
|
|
|
# TBD: should we consider all block devices by default, but still
|
|
# provide some 'control' through the node information
|
|
# (for example target_raid_config at the time of calling this). This
|
|
# may make sense if you do not want the delete_config to touch some
|
|
# drives, like cinder volumes locally attached, for example, or any
|
|
# kind of 'non-ephemeral' drive that you do not want to consider during
|
|
# deployment (= specify which drives to consider just like create
|
|
# configuration might consider the physical_disks parameter in a near
|
|
# future)
|
|
|
|
# Consider partitions first, before underlying disks, never hurts and
|
|
# can even avoid some failures. Example to reproduce:
|
|
# mdadm --stop /dev/md0
|
|
# mdadm --zero-superblock /dev/block
|
|
# mdadm: Unrecognised md component device - /dev/block
|
|
# (mdadm -E /dev/block still returns 0 so won't be skipped for zeroing)
|
|
# mdadm --zero-superblock /dev/block1
|
|
# mdadm: Couldn't open /dev/block for write - not zeroing
|
|
# mdadm -E /dev/block1: still shows superblocks
|
|
all_blks = reversed(self.list_block_devices(include_partitions=True))
|
|
do_not_delete_disks = set()
|
|
for blk in all_blks:
|
|
if blk.name in do_not_delete_devices:
|
|
do_not_delete_disks.add(utils.extract_device(blk.name))
|
|
continue
|
|
if blk.name in do_not_delete_disks:
|
|
continue
|
|
try:
|
|
il_utils.execute('mdadm', '--examine', blk.name,
|
|
use_standard_locale=True)
|
|
except processutils.ProcessExecutionError as e:
|
|
if "No md superblock detected" in str(e):
|
|
# actually not a component device
|
|
continue
|
|
else:
|
|
LOG.warning("Failed to examine device %(name)s: %(err)s",
|
|
{'name': blk.name, 'err': e})
|
|
continue
|
|
try:
|
|
il_utils.execute('mdadm', '--zero-superblock', blk.name)
|
|
except processutils.ProcessExecutionError as e:
|
|
LOG.warning('Failed to remove superblock from'
|
|
'%(device)s: %(err)s',
|
|
{'device': raid_device.name, 'err': e})
|
|
|
|
# Erase all partition tables we created
|
|
all_holder_disks_uniq = list(
|
|
collections.OrderedDict.fromkeys(all_holder_disks))
|
|
for holder_disk in all_holder_disks_uniq:
|
|
if holder_disk in do_not_delete_disks:
|
|
# Remove just partitions not listed in keep_partitions
|
|
del_list = delete_partitions[holder_disk]
|
|
if del_list:
|
|
LOG.warning('Holder disk %(dev)s contains logical disk '
|
|
'on the skip list. Deleting just partitions: '
|
|
'%(parts)s', {'dev': holder_disk,
|
|
'parts': del_list})
|
|
for part in del_list:
|
|
il_utils.execute('parted', holder_disk, 'rm', part)
|
|
else:
|
|
LOG.warning('Holder disk %(dev)s contains only logical '
|
|
'disk(s) on the skip list', holder_disk)
|
|
continue
|
|
LOG.info('Removing partitions on holder disk %s', holder_disk)
|
|
try:
|
|
il_utils.execute('wipefs', '-af', holder_disk)
|
|
except processutils.ProcessExecutionError as e:
|
|
LOG.warning('Failed to remove partitions on %s: %s',
|
|
holder_disk, e)
|
|
|
|
LOG.debug("Finished deleting Software RAID(s)")
|
|
|
|
def validate_configuration(self, raid_config, node):
|
|
"""Validate a (software) RAID configuration
|
|
|
|
Validate a given raid_config, in particular with respect to
|
|
the limitations of the current implementation of software
|
|
RAID support.
|
|
|
|
:param raid_config: The current RAID configuration in the usual format.
|
|
"""
|
|
LOG.debug("Validating Software RAID config: %s", raid_config)
|
|
|
|
if not raid_config:
|
|
LOG.error("No RAID config passed")
|
|
return False
|
|
|
|
logical_disks = raid_config.get('logical_disks')
|
|
if not logical_disks:
|
|
msg = "RAID config contains no logical disks"
|
|
raise errors.SoftwareRAIDError(msg)
|
|
|
|
raid_errors = []
|
|
|
|
# Only one or two RAID devices are supported for now.
|
|
if len(logical_disks) not in [1, 2]:
|
|
msg = ("Software RAID configuration requires one or "
|
|
"two logical disks")
|
|
raid_errors.append(msg)
|
|
|
|
volume_names = []
|
|
# All disks need to be flagged for Software RAID
|
|
for logical_disk in logical_disks:
|
|
if logical_disk.get('controller') != 'software':
|
|
msg = ("Software RAID configuration requires all logical "
|
|
"disks to have 'controller'='software'")
|
|
raid_errors.append(msg)
|
|
|
|
volume_name = logical_disk.get('volume_name')
|
|
if volume_name is not None:
|
|
if volume_name in volume_names:
|
|
msg = ("Duplicate software RAID device name %s "
|
|
"detected" % volume_name)
|
|
raid_errors.append(msg)
|
|
else:
|
|
volume_names.append(volume_name)
|
|
|
|
physical_disks = logical_disk.get('physical_disks')
|
|
if physical_disks is not None:
|
|
if (not isinstance(physical_disks, list)
|
|
or len(physical_disks) < 2):
|
|
msg = ("The physical_disks parameter for software RAID "
|
|
"must be a list with at least 2 items, each "
|
|
"specifying a disk in the device hints format")
|
|
raid_errors.append(msg)
|
|
if any(not isinstance(item, dict) for item in physical_disks):
|
|
msg = ("The physical_disks parameter for software RAID "
|
|
"must be a list of device hints (dictionaries)")
|
|
raid_errors.append(msg)
|
|
|
|
# The first RAID device needs to be RAID-1.
|
|
if logical_disks[0]['raid_level'] != '1':
|
|
msg = ("Software RAID Configuration requires RAID-1 for the "
|
|
"first logical disk")
|
|
raid_errors.append(msg)
|
|
|
|
# Additional checks when we have two RAID devices.
|
|
if len(logical_disks) == 2:
|
|
size1 = logical_disks[0]['size_gb']
|
|
size2 = logical_disks[1]['size_gb']
|
|
|
|
# Only one logical disk is allowed to span the whole device.
|
|
if size1 == 'MAX' and size2 == 'MAX':
|
|
msg = ("Software RAID can have only one RAID device with "
|
|
"size 'MAX'")
|
|
raid_errors.append(msg)
|
|
|
|
# Check the accepted RAID levels.
|
|
current_level = logical_disks[1]['raid_level']
|
|
if current_level not in SUPPORTED_SOFTWARE_RAID_LEVELS:
|
|
msg = ("Software RAID configuration does not support "
|
|
"RAID level %s" % current_level)
|
|
raid_errors.append(msg)
|
|
physical_device_count = len(self.list_block_devices())
|
|
if current_level == '5' and physical_device_count < 3:
|
|
msg = ("Software RAID configuration is not possible for "
|
|
"RAID level 5 with only %s block devices found."
|
|
% physical_device_count)
|
|
raid_errors.append(msg)
|
|
if current_level == '6' and physical_device_count < 4:
|
|
msg = ("Software RAID configuration is not possible for "
|
|
"RAID level 6 with only %s block devices found."
|
|
% physical_device_count)
|
|
raid_errors.append(msg)
|
|
if raid_errors:
|
|
error = ('Could not validate Software RAID config for %(node)s: '
|
|
'%(errors)s') % {'node': node['uuid'],
|
|
'errors': '; '.join(raid_errors)}
|
|
raise errors.SoftwareRAIDError(error)
|
|
|
|
def write_image(self, node, ports, image_info, configdrive=None):
|
|
"""A deploy step to write an image.
|
|
|
|
Downloads and writes an image to disk if necessary. Also writes a
|
|
configdrive to disk if the configdrive parameter is specified.
|
|
|
|
:param node: A dictionary of the node object
|
|
:param ports: A list of dictionaries containing information
|
|
of ports for the node
|
|
:param image_info: Image information dictionary.
|
|
:param configdrive: A string containing the location of the config
|
|
drive as a URL OR the contents (as gzip/base64)
|
|
of the configdrive. Optional, defaults to None.
|
|
"""
|
|
ext = ext_base.get_extension('standby')
|
|
cmd = ext.prepare_image(image_info=image_info, configdrive=configdrive)
|
|
# The result is asynchronous, wait here.
|
|
return cmd.wait()
|
|
|
|
def generate_tls_certificate(self, ip_address):
|
|
"""Generate a TLS certificate for the IP address."""
|
|
return tls_utils.generate_tls_certificate(ip_address)
|
|
|
|
def inject_files(self, node, ports, files=None, verify_ca=True):
|
|
"""A deploy step to inject arbitrary files.
|
|
|
|
:param node: A dictionary of the node object
|
|
:param ports: A list of dictionaries containing information
|
|
of ports for the node (unused)
|
|
:param files: See :py:mod:`inject_files`
|
|
:param verify_ca: Whether to verify TLS certificate.
|
|
"""
|
|
return inject_files.inject_files(node, ports, files, verify_ca)
|
|
|
|
def collect_system_logs(self, io_dict, file_list):
|
|
commands = {
|
|
'df': ['df', '-a'],
|
|
'dmesg': ['dmesg'],
|
|
'iptables': ['iptables', '-L'],
|
|
'ip_addr': ['ip', 'addr'],
|
|
'lsblk': ['lsblk', '--all',
|
|
'-o%s' % ','.join(utils.LSBLK_COLUMNS)],
|
|
'lsblk-full': ['lsblk', '--all', '--bytes',
|
|
'--output-all', '--pairs'],
|
|
'lshw': ['lshw', '-quiet', '-json'],
|
|
'mdstat': ['cat', '/proc/mdstat'],
|
|
'mount': ['mount'],
|
|
'multipath': ['multipath', '-ll'],
|
|
'parted': ['parted', '-l'],
|
|
'ps': ['ps', 'au'],
|
|
}
|
|
for name, cmd in commands.items():
|
|
utils.try_collect_command_output(io_dict, name, cmd)
|
|
|
|
_collect_udev(io_dict)
|
|
|
|
|
|
def _collect_udev(io_dict):
|
|
"""Collect device properties from udev."""
|
|
try:
|
|
out, _e = il_utils.execute('lsblk', '-no', 'KNAME')
|
|
except processutils.ProcessExecutionError as exc:
|
|
LOG.warning('Could not list block devices: %s', exc)
|
|
return
|
|
|
|
context = pyudev.Context()
|
|
|
|
for kname in out.splitlines():
|
|
kname = kname.strip()
|
|
if not kname:
|
|
continue
|
|
|
|
name = os.path.join('/dev', kname)
|
|
|
|
try:
|
|
udev = pyudev.Devices.from_device_file(context, name)
|
|
except Exception as e:
|
|
LOG.warning("Device %(dev)s is inaccessible, skipping... "
|
|
"Error: %(error)s", {'dev': name, 'error': e})
|
|
continue
|
|
|
|
try:
|
|
props = dict(udev.properties)
|
|
except AttributeError: # pyudev < 0.20
|
|
props = dict(udev)
|
|
|
|
fp = io.TextIOWrapper(io.BytesIO(), encoding='utf-8')
|
|
json.dump(props, fp)
|
|
buf = fp.detach()
|
|
buf.seek(0)
|
|
io_dict[f'udev/{kname}'] = buf
|
|
|
|
|
|
def _compare_extensions(ext1, ext2):
|
|
mgr1 = ext1.obj
|
|
mgr2 = ext2.obj
|
|
return mgr2.evaluate_hardware_support() - mgr1.evaluate_hardware_support()
|
|
|
|
|
|
def get_managers():
|
|
"""Get a list of hardware managers in priority order.
|
|
|
|
Use stevedore to find all eligible hardware managers, sort them based on
|
|
self-reported (via evaluate_hardware_support()) priorities, and return them
|
|
in a list. The resulting list is cached in _global_managers.
|
|
|
|
:returns: Priority-sorted list of hardware managers
|
|
:raises HardwareManagerNotFound: if no valid hardware managers found
|
|
"""
|
|
global _global_managers
|
|
|
|
if not _global_managers:
|
|
extension_manager = stevedore.ExtensionManager(
|
|
namespace='ironic_python_agent.hardware_managers',
|
|
invoke_on_load=True)
|
|
|
|
# There will always be at least one extension available (the
|
|
# GenericHardwareManager).
|
|
extensions = sorted(extension_manager,
|
|
key=functools.cmp_to_key(_compare_extensions))
|
|
|
|
preferred_managers = []
|
|
|
|
for extension in extensions:
|
|
if extension.obj.evaluate_hardware_support() > 0:
|
|
preferred_managers.append(extension.obj)
|
|
LOG.info('Hardware manager found: %s',
|
|
extension.entry_point_target)
|
|
|
|
if not preferred_managers:
|
|
raise errors.HardwareManagerNotFound
|
|
|
|
_global_managers = preferred_managers
|
|
|
|
return _global_managers
|
|
|
|
|
|
def dispatch_to_all_managers(method, *args, **kwargs):
|
|
"""Dispatch a method to all hardware managers.
|
|
|
|
Dispatches the given method in priority order as sorted by
|
|
`get_managers`. If the method doesn't exist or raises
|
|
IncompatibleHardwareMethodError, it continues to the next hardware manager.
|
|
All managers that have hardware support for this node will be called,
|
|
and their responses will be added to a dictionary of the form
|
|
{HardwareManagerClassName: response}.
|
|
|
|
:param method: hardware manager method to dispatch
|
|
:param args: arguments to dispatched method
|
|
:param kwargs: keyword arguments to dispatched method
|
|
:raises errors.HardwareManagerMethodNotFound: if all managers raise
|
|
IncompatibleHardwareMethodError.
|
|
:returns: a dictionary with keys for each hardware manager that returns
|
|
a response and the value as a list of results from that hardware
|
|
manager.
|
|
"""
|
|
responses = {}
|
|
managers = get_managers()
|
|
for manager in managers:
|
|
if getattr(manager, method, None):
|
|
try:
|
|
response = getattr(manager, method)(*args, **kwargs)
|
|
except errors.IncompatibleHardwareMethodError:
|
|
LOG.debug('HardwareManager %(manager)s does not '
|
|
'support %(method)s',
|
|
{'manager': manager, 'method': method})
|
|
continue
|
|
except Exception as e:
|
|
LOG.exception('Unexpected error dispatching %(method)s to '
|
|
'manager %(manager)s: %(e)s',
|
|
{'method': method, 'manager': manager, 'e': e})
|
|
raise
|
|
responses[manager.__class__.__name__] = response
|
|
else:
|
|
LOG.debug('HardwareManager %(manager)s does not '
|
|
'have method %(method)s',
|
|
{'manager': manager, 'method': method})
|
|
|
|
if responses == {}:
|
|
raise errors.HardwareManagerMethodNotFound(method)
|
|
|
|
return responses
|
|
|
|
|
|
def dispatch_to_managers(method, *args, **kwargs):
|
|
"""Dispatch a method to best suited hardware manager.
|
|
|
|
Dispatches the given method in priority order as sorted by
|
|
`get_managers`. If the method doesn't exist or raises
|
|
IncompatibleHardwareMethodError, it is attempted again with a more generic
|
|
hardware manager. This continues until a method executes that returns
|
|
any result without raising an IncompatibleHardwareMethodError.
|
|
|
|
:param method: hardware manager method to dispatch
|
|
:param args: arguments to dispatched method
|
|
:param kwargs: keyword arguments to dispatched method
|
|
|
|
:returns: result of successful dispatch of method
|
|
:raises HardwareManagerMethodNotFound: if all managers failed the method
|
|
:raises HardwareManagerNotFound: if no valid hardware managers found
|
|
"""
|
|
managers = get_managers()
|
|
for manager in managers:
|
|
if getattr(manager, method, None):
|
|
try:
|
|
return getattr(manager, method)(*args, **kwargs)
|
|
except errors.IncompatibleHardwareMethodError:
|
|
LOG.debug('HardwareManager %(manager)s does not '
|
|
'support %(method)s',
|
|
{'manager': manager, 'method': method})
|
|
except Exception as e:
|
|
LOG.exception('Unexpected error dispatching %(method)s to '
|
|
'manager %(manager)s: %(e)s',
|
|
{'method': method, 'manager': manager, 'e': e})
|
|
raise
|
|
else:
|
|
LOG.debug('HardwareManager %(manager)s does not '
|
|
'have method %(method)s',
|
|
{'manager': manager, 'method': method})
|
|
|
|
raise errors.HardwareManagerMethodNotFound(method)
|
|
|
|
|
|
_CACHED_HW_INFO = None
|
|
|
|
|
|
def list_hardware_info(use_cache=True):
|
|
"""List hardware information with caching."""
|
|
global _CACHED_HW_INFO
|
|
|
|
if _CACHED_HW_INFO is None:
|
|
_CACHED_HW_INFO = dispatch_to_managers('list_hardware_info')
|
|
return _CACHED_HW_INFO
|
|
|
|
if use_cache:
|
|
return _CACHED_HW_INFO
|
|
else:
|
|
return dispatch_to_managers('list_hardware_info')
|
|
|
|
|
|
def cache_node(node):
|
|
"""Store the node object in the hardware module.
|
|
|
|
Stores the node object in the hardware module to facilitate the
|
|
access of a node information in the hardware extensions.
|
|
|
|
If the new node does not match the previously cached one, wait for the
|
|
expected root device to appear.
|
|
|
|
:param node: Ironic node object
|
|
"""
|
|
global NODE
|
|
new_node = NODE is None or NODE['uuid'] != node['uuid']
|
|
NODE = node
|
|
|
|
if new_node:
|
|
LOG.info('Cached node %s, waiting for its root device to appear',
|
|
node['uuid'])
|
|
# Root device hints, stored in the new node, can change the expected
|
|
# root device. So let us wait for it to appear again.
|
|
dispatch_to_managers('wait_for_disks')
|
|
|
|
|
|
def get_cached_node():
|
|
"""Guard function around the module variable NODE."""
|
|
return NODE
|
|
|
|
|
|
def get_current_versions():
|
|
"""Fetches versions from all hardware managers.
|
|
|
|
:returns: Dict in the format {name: version} containing one entry for
|
|
every hardware manager.
|
|
"""
|
|
return {version.get('name'): version.get('version')
|
|
for version in dispatch_to_all_managers('get_version').values()}
|
|
|
|
|
|
def check_versions(provided_version=None):
|
|
"""Ensure the version of hardware managers hasn't changed.
|
|
|
|
:param provided_version: Hardware manager versions used by ironic.
|
|
:raises: errors.VersionMismatch if any hardware manager version on
|
|
the currently running agent doesn't match the one stored in
|
|
provided_version.
|
|
:returns: None
|
|
"""
|
|
# If the version is None, assume this is the first run
|
|
if provided_version is None:
|
|
return
|
|
agent_version = get_current_versions()
|
|
if provided_version != agent_version:
|
|
LOG.warning('Mismatched hardware managers versions. Agent version: '
|
|
'%(agent)s, node version: %(node)s',
|
|
{'agent': agent_version, 'node': provided_version})
|
|
raise errors.VersionMismatch(agent_version=agent_version,
|
|
node_version=provided_version)
|
|
|
|
|
|
def _step_sort_key(step):
|
|
return (-step['hwm']['support'], -step['priority'], step['hwm']['name'])
|
|
|
|
|
|
def deduplicate_steps(candidate_steps):
|
|
"""Remove duplicated clean or deploy steps
|
|
|
|
Deduplicates steps returned from HardwareManagers to prevent running
|
|
a given step more than once. Other than individual step priority,
|
|
it doesn't actually impact the deployment which specific steps are kept
|
|
and what HardwareManager they are associated with.
|
|
However, in order to make testing easier, this method returns
|
|
deterministic results.
|
|
|
|
Uses the following filtering logic to decide which step "wins":
|
|
|
|
- Keep the step that belongs to HardwareManager with highest
|
|
HardwareSupport (larger int) value.
|
|
- If equal support level, keep the step with the higher defined priority
|
|
(larger int).
|
|
- If equal support level and priority, keep the step associated with the
|
|
HardwareManager whose name comes earlier in the alphabet.
|
|
|
|
:param candidate_steps: A dict containing all possible steps from
|
|
all managers, key=manager, value=list of steps
|
|
:returns: A deduplicated dictionary of {hardware_manager: [steps]}
|
|
"""
|
|
support = dispatch_to_all_managers(
|
|
'evaluate_hardware_support')
|
|
|
|
steps = collections.defaultdict(list)
|
|
deduped_steps = collections.defaultdict(list)
|
|
|
|
for manager, manager_steps in candidate_steps.items():
|
|
# We cannot deduplicate steps with unknown hardware support
|
|
if manager not in support:
|
|
LOG.warning('Unknown hardware support for %(manager)s, '
|
|
'dropping steps: %(steps)s',
|
|
{'manager': manager, 'steps': manager_steps})
|
|
continue
|
|
|
|
for step in manager_steps:
|
|
# build a new dict of steps that's easier to filter
|
|
step['hwm'] = {'name': manager,
|
|
'support': support[manager]}
|
|
steps[step['step']].append(step)
|
|
|
|
for step_name, step_list in steps.items():
|
|
winning_step = sorted(step_list, key=_step_sort_key)[0]
|
|
# Remove extra metadata we added to the step for filtering
|
|
manager = winning_step.pop('hwm')['name']
|
|
# Add winning step to deduped_steps
|
|
deduped_steps[manager].append(winning_step)
|
|
|
|
return deduped_steps
|
|
|
|
|
|
def get_multipath_status():
|
|
"""Return the status of multipath initialization."""
|
|
# NOTE(TheJulia): Provides a nice place to mock out and simplify testing
|
|
# as if we directly try and work with the global var, we will be racing
|
|
# tests endlessly.
|
|
return MULTIPATH_ENABLED
|
|
|
|
|
|
def safety_check_block_device(node, device):
|
|
"""Performs safety checking of a block device before destroying.
|
|
|
|
In order to guard against distruction of file systems such as
|
|
shared-disk file systems
|
|
(https://en.wikipedia.org/wiki/Clustered_file_system#SHARED-DISK)
|
|
or similar filesystems where multiple distinct computers may have
|
|
unlocked concurrent IO access to the entire block device or
|
|
SAN Logical Unit Number, we need to evaluate, and block cleaning
|
|
from occuring on these filesystems *unless* we have been explicitly
|
|
configured to do so.
|
|
|
|
This is because cleaning is an intentionally distructive operation,
|
|
and once started against such a device, given the complexities of
|
|
shared disk clustered filesystems where concurrent access is a design
|
|
element, in all likelihood the entire cluster can be negatively
|
|
impacted, and an operator will be forced to recover from snapshot and
|
|
or backups of the volume's contents.
|
|
|
|
:param node: A node, or cached node object.
|
|
:param device: String representing the path to the block
|
|
device to be checked.
|
|
:raises: ProtectedDeviceError when a device is identified with
|
|
one of these known clustered filesystems, and the overall
|
|
settings have not indicated for the agent to skip such
|
|
safety checks.
|
|
"""
|
|
|
|
# NOTE(TheJulia): While this seems super rare, I found out after this
|
|
# thread of discussion started that I have customers which have done
|
|
# this and wiped out SAN volumes and their contents unintentionally
|
|
# as a result of these filesystems not being guarded.
|
|
# For those not familiar with shared disk clustered filesystems, think
|
|
# of it as like your impacting a Ceph cluster, except your suddenly
|
|
# removing the underlying disks from the OSD, and the entire cluster
|
|
# goes down.
|
|
|
|
if not CONF.guard_special_filesystems:
|
|
return
|
|
di_info = node.get('driver_internal_info', {})
|
|
if not di_info.get('wipe_special_filesystems', True):
|
|
return
|
|
lsblk_ids = ['UUID', 'PTUUID', 'PARTTYPE', 'PARTUUID']
|
|
report = il_utils.execute('lsblk', '-bia', '--json',
|
|
'-o{}'.format(','.join(lsblk_ids)),
|
|
device, check_exit_code=[0])[0]
|
|
|
|
try:
|
|
report_json = json.loads(report)
|
|
except json.decoder.JSONDecodeError as ex:
|
|
LOG.error("Unable to decode lsblk output, invalid JSON: %s", ex)
|
|
|
|
device_json = report_json['blockdevices'][0]
|
|
identified_fs_types = []
|
|
identified_ids = []
|
|
|
|
fstype = device_json.get('fstype')
|
|
identified_fs_types.append(fstype)
|
|
for key in lsblk_ids:
|
|
identified_ids.append(device_json.get(key.lower()))
|
|
|
|
_check_for_special_partitions_filesystems(
|
|
device,
|
|
identified_ids,
|
|
identified_fs_types)
|
|
|
|
|
|
def _check_for_special_partitions_filesystems(device, ids, fs_types):
|
|
"""Compare supplied IDs, Types to known items, and raise if found.
|
|
|
|
:param device: The block device in use, specificially for logging.
|
|
:param ids: A list above IDs found to check.
|
|
:param fs_types: A list of FS types found to check.
|
|
:raises: ProtectedDeviceError should a partition label or metadata
|
|
be discovered which suggests a shared disk clustered filesystem
|
|
has been discovered.
|
|
"""
|
|
guarded_ids = {
|
|
# Apparently GPFS can used shared volumes....
|
|
'37AFFC90-EF7D-4E96-91C3-2D7AE055B174': 'IBM GPFS Partition',
|
|
# Shared volume parallel filesystem
|
|
'AA31E02A-400F-11DB-9590-000C2911D1B8': 'VMware VMFS Partition (GPT)',
|
|
'0xfb': 'VMware VMFS Partition (MBR)',
|
|
}
|
|
for key, value in guarded_ids.items():
|
|
for id_value in ids:
|
|
if key == id_value:
|
|
raise errors.ProtectedDeviceError(
|
|
device=device,
|
|
what=value)
|
|
|
|
guarded_fs_types = {
|
|
'gfs2': 'Red Hat Global File System 2',
|
|
}
|
|
|
|
for key, value in guarded_fs_types.items():
|
|
for fs in fs_types:
|
|
if key == fs:
|
|
raise errors.ProtectedDeviceError(
|
|
device=device,
|
|
what=value)
|