Out-of-band RAID configuration for Gen10 and above HPE Proliant Servers
|
|
=======================================================================
|
|
|
|
https://bugs.launchpad.net/ironic/+bug/1716329
|
|
|
|
This specification proposes implementation of out-of-band RAID configuration
|
|
for ILO managed HPE Proliant servers.
|
|
|
|
Problem description
|
|
===================
|
|
|
|
In the current scenario where RAID configuration on HPE Proliant servers is
|
|
done only via inband cleaning, Ilo5 based HPE Proliant Gen10 servers provide
|
|
support to perform out-of-band RAID configuration which was not there in Gen9
|
|
and below servers. However, the raid creation or deletion will take into effect
|
|
only when the system reaches POST stage. Hence, creation or deletion of RAID
|
|
needs to be accompanied by a reboot.
|
|
|
|
Proposed change
|
|
===============
|
|
|
|
This spec proposes to implement out-of-band RAID configuration as described
|
|
by the parent spec [1]. This will require the implementation of a new hardware
|
|
type ``Ilo5Hardware`` and a new raid interface for ilo as ``IloRAID``.
|
|
|
|
OOB RAID configuration will be a four step process.
|
|
1. delete_configuration - delete the current raid config from the system.
|
|
2. read_configuration - get the updated raid config from system and update
|
|
the node properties accordingly.
|
|
3. create_configuration - create the raid config which set by the user in
|
|
target_raid_config of node properties.
|
|
4. read_configuration - get the updated raid config from system and update
|
|
the node properties accordingly.
|
|
|
|
List of changes required:
|
|
|
|
* The following would be the composition of ``Ilo5Hardware``:
|
|
|
|
+ This hardware type would be supported on ilo5 based HPE Proliant servers.
|
|
|
|
+ Ilo5Hardware will inherit all interfaces of parent class IloHardware.
|
|
|
|
+ Ilo5Hardware will support the new RAID interface ``IloRAID``.
|
|
|
|
* The following would be the composition of ``IloRAID``:
|
|
|
|
+ IloRAID will inherit RAIDInterface of base class.
|
|
|
|
+ ``delete_configuration`` - This will delete the RAID configuration on
|
|
the bare metal node.
|
|
|
|
- Since a reboot is required for changes to get reflected, this function
|
|
will be decorated with additional argument `reboot_required` with
|
|
value set to `True`.
|
|
|
|
- It will create an IloClient object from proliantutils library to do
|
|
operations on the iLO. This will make call to delete_raid_configuration
|
|
of proliantutils library to delete the logical drives on the system.
|
|
|
|
+ ``create_configuration`` - This will create the RAID configuration on
|
|
the bare metal node.
|
|
|
|
- Since a reboot is required for changes to get reflected, this function
|
|
will be decorated with additional argument `reboot_required` with
|
|
value set to `True`.
|
|
|
|
- It will create an IloClient object from proliantutils library to do
|
|
operations on the iLO. This will make call to create_raid_configuration
|
|
of proliantutils library to place a request to firmware to create the
|
|
logical drives on the system.
|
|
|
|
+ ``read_configuration`` - This will read the RAID configuration on
|
|
the bare metal node.
|
|
|
|
- It will create an IloClient object from proliantutils library to do
|
|
operations on the iLO. This will make call to read_raid_configuration
|
|
of proliantutils library to get the logical drives on the system.
|
|
Hence, it will update the node properties with the actual RAID
|
|
configuration when called after ``create_configuration`` and to ``None``
|
|
when called after ``delete_configuration``.
|
|
|
|
* The following would be the updates required in cleaning architecture in
|
|
ironic to support post reboot operation if required any clean step.
|
|
|
|
+ Addition a new boolean positional argument ``reboot_required`` to
|
|
clean_step function of BaseInterface. Default is set to ``False`` for
|
|
this parameter.
|
|
NOTE: The same approach is being used in inband cleaning for steps
|
|
that require reboot.
|
|
|
|
+ Update ironic/conductor/manager.py:_do_next_clean_step() for each
|
|
step to call prepare_cleaning() if reboot_required is set to True
|
|
and result of the last command interface.execute_clean-step() is
|
|
not ``clean wait``.
|
|
|
|
Alternatives
|
|
------------
|
|
|
|
One can perform in-band raid configuration to achieve the same result.
|
|
However, The ramdisk to be used in such case should have proliant-tools
|
|
element that bundles 'ssacli' utility required for RAID operations as
|
|
part of the image.
|
|
|
|
Data model impact
|
|
-----------------
|
|
None
|
|
|
|
State Machine Impact
|
|
--------------------
|
|
None
|
|
|
|
REST API impact
|
|
---------------
|
|
None
|
|
|
|
Client (CLI) impact
|
|
-------------------
|
|
None
|
|
|
|
RPC API impact
|
|
--------------
|
|
None
|
|
|
|
Driver API impact
|
|
-----------------
|
|
None
|
|
|
|
Nova driver impact
|
|
------------------
|
|
None
|
|
|
|
Ramdisk impact
|
|
--------------
|
|
None
|
|
|
|
Security impact
|
|
---------------
|
|
None
|
|
|
|
Other end user impact
|
|
---------------------
|
|
None
|
|
|
|
Scalability impact
|
|
------------------
|
|
None
|
|
|
|
Performance Impact
|
|
------------------
|
|
None
|
|
|
|
Other deployer impact
|
|
---------------------
|
|
|
|
User need to configure below two things to make use of OOB RAID configuration
|
|
on HPE Proliant Gen10 servers.
|
|
|
|
* Configure the new hardware type ``ilo5`` to ([DEFAULT]
|
|
``enabled_hardware_types``).
|
|
|
|
* Configure the new raid interface ``ilo5`` to ([DEFAULT]
|
|
``enabled_raid_interfaces``).
|
|
|
|
|
|
Developer impact
|
|
----------------
|
|
None
|
|
|
|
|
|
Implementation
|
|
==============
|
|
|
|
Assignee(s)
|
|
-----------
|
|
|
|
Primary assignee:
|
|
theanshuljain
|
|
|
|
Work Items
|
|
----------
|
|
|
|
* Add a new hardware type for ilo ``Ilo5Hardware`` which inherits IloHardware.
|
|
* Add a new hardware interface ``IloRAID`` which inherits base.RAIDInterface.
|
|
* Writing unit-test cases for the new OOB RAID interface.
|
|
|
|
|
|
Dependencies
|
|
============
|
|
|
|
Support for OOB RAID in proliantutils is under development and is yet to be
|
|
released.
|
|
|
|
|
|
Testing
|
|
=======
|
|
|
|
Unit test cases will be added. Will be tested in 3rd party CI setup.
|
|
|
|
Upgrades and Backwards Compatibility
|
|
====================================
|
|
|
|
None
|
|
|
|
|
|
Documentation Impact
|
|
====================
|
|
|
|
Need to update iLO driver documentation for new hardware type and RAID
|
|
interface.
|
|
|
|
|
|
References
|
|
==========
|
|
|
|
[1] Ironic generic raid spec: https://review.opendev.org/173214
|