Merge "Update iDRAC doc on Redfish vendor passthru interface"
This commit is contained in:
commit
00aea13949
@ -32,7 +32,8 @@ The ``idrac`` hardware type supports the following Ironic interfaces:
|
||||
* `Management Interface`_: Boot device and firmware management
|
||||
* Power Interface: Power management
|
||||
* `RAID Interface`_: RAID controller and disk management
|
||||
* `Vendor Interface`_: BIOS management
|
||||
* `Vendor Interface`_: BIOS management (WSMAN) and eject virtual media
|
||||
(Redfish)
|
||||
|
||||
Prerequisites
|
||||
-------------
|
||||
@ -88,7 +89,7 @@ following configuration:
|
||||
enabled_management_interfaces=idrac-redfish
|
||||
enabled_power_interfaces=idrac-redfish
|
||||
enabled_raid_interfaces=idrac-wsman
|
||||
enabled_vendor_interfaces=idrac-wsman
|
||||
enabled_vendor_interfaces=idrac-redfish
|
||||
|
||||
Below is the list of supported interface implementations in priority
|
||||
order:
|
||||
@ -108,7 +109,8 @@ Interface Supported Implementations
|
||||
``raid`` ``idrac-wsman``, ``idrac``, ``no-raid``
|
||||
``rescue`` ``no-rescue``, ``agent``
|
||||
``storage`` ``noop``, ``cinder``, ``external``
|
||||
``vendor`` ``idrac-wsman``, ``idrac``, ``no-vendor``
|
||||
``vendor`` ``idrac-wsman``, ``idrac``, ``idrac-redfish``,
|
||||
``no-vendor``
|
||||
================ ===================================================
|
||||
|
||||
.. NOTE::
|
||||
@ -179,7 +181,7 @@ hardware type using Redfish for all interfaces:
|
||||
--management-interface idrac-redfish \
|
||||
--power-interface idrac-redfish \
|
||||
--raid-interface no-raid \
|
||||
--vendor-interface no-vendor
|
||||
--vendor-interface idrac-redfish
|
||||
|
||||
The following command enrolls a bare metal node with the ``idrac``
|
||||
hardware type assuming a mix of Redfish and WSMAN interfaces are used:
|
||||
@ -410,7 +412,10 @@ be used to fetch the information directly from the Dell bare metal:
|
||||
Vendor Interface
|
||||
================
|
||||
|
||||
Dell iDRAC BIOS management is available through the Ironic vendor
|
||||
idrac-wsman
|
||||
-----------
|
||||
|
||||
Dell iDRAC BIOS management is available through the Ironic WSMAN vendor
|
||||
passthru interface.
|
||||
|
||||
======================== ============ ======================================
|
||||
@ -452,7 +457,7 @@ Method Name HTTP Method Description
|
||||
|
||||
|
||||
Examples
|
||||
--------
|
||||
^^^^^^^^
|
||||
|
||||
Get BIOS Config
|
||||
~~~~~~~~~~~~~~~
|
||||
@ -574,7 +579,7 @@ The abandon command does not provide a response body.
|
||||
|
||||
|
||||
Change Boot Mode
|
||||
----------------
|
||||
^^^^^^^^^^^^^^^^
|
||||
|
||||
The boot mode of the iDRAC can be changed to:
|
||||
|
||||
@ -605,7 +610,8 @@ The UEFI boot mode offers:
|
||||
* Consolidated firmware user interface
|
||||
* Enhanced resource allocation for boot device firmware
|
||||
|
||||
The boot mode can be changed via the vendor passthru interface as follows:
|
||||
The boot mode can be changed via the WSMAN vendor passthru interface as
|
||||
follows:
|
||||
|
||||
.. code-block:: bash
|
||||
|
||||
@ -623,6 +629,22 @@ The boot mode can be changed via the vendor passthru interface as follows:
|
||||
baremetal node passthru call <node> commit_bios_config \
|
||||
--arg "reboot=true"
|
||||
|
||||
idrac-redfish
|
||||
-------------
|
||||
|
||||
Through the ``idrac-redfish`` vendor passthru interface these methods are
|
||||
available:
|
||||
|
||||
================ ============ ==============================================
|
||||
Method Name HTTP Method Description
|
||||
================ ============ ==============================================
|
||||
``eject_media`` ``POST`` Eject a virtual media device. If no device is
|
||||
provided then all attached devices will be
|
||||
ejected. Optional argument: ``boot_device`` -
|
||||
the boot device to eject, either, ``cd``,
|
||||
``dvd``, ``usb`` or ``floppy``.
|
||||
================ ============ ==============================================
|
||||
|
||||
Known Issues
|
||||
============
|
||||
|
||||
@ -653,11 +675,12 @@ settings.
|
||||
.. _Ironic_RAID: https://docs.openstack.org/ironic/latest/admin/raid.html
|
||||
.. _iDRAC: https://www.dell.com/idracmanuals
|
||||
|
||||
Vendor passthru timeout
|
||||
-----------------------
|
||||
WSMAN vendor passthru timeout
|
||||
-----------------------------
|
||||
|
||||
When iDRAC is not ready and executing vendor passthru commands, they take more
|
||||
time as waiting for iDRAC to become ready again and then time out, for example:
|
||||
When iDRAC is not ready and executing WSMAN vendor passthru commands, they take
|
||||
more time as waiting for iDRAC to become ready again and then time out,
|
||||
for example:
|
||||
|
||||
.. code-block:: bash
|
||||
|
||||
|
@ -72,7 +72,7 @@ class RedfishVendorPassthru(base.VendorInterface):
|
||||
@METRICS.timer('RedfishVendorPassthru.eject_vmedia')
|
||||
@base.passthru(['POST'],
|
||||
description=_("Eject a virtual media device. If no device "
|
||||
"is provided than all attached devices will "
|
||||
"is provided then all attached devices will "
|
||||
"be ejected. "
|
||||
"Optional arguments: "
|
||||
"'boot_device' - the boot device to eject, "
|
||||
|
Loading…