Add PXE reset known issue to the docs
This change also addresses some nits from the parent change.
Change-Id: I72b9577a95705c7a392444b3f1bf4a821f2dec9f
(cherry picked from commit 4d810c160d
)
This commit is contained in:
parent
134f3b3317
commit
3defeea7f0
|
@ -227,7 +227,7 @@ BMC would be as follows::
|
||||||
},
|
},
|
||||||
{
|
{
|
||||||
"name": "SriovGlobalEnable",
|
"name": "SriovGlobalEnable",
|
||||||
"value": "Enabled
|
"value": "Enabled"
|
||||||
}
|
}
|
||||||
]
|
]
|
||||||
}
|
}
|
||||||
|
@ -235,8 +235,8 @@ BMC would be as follows::
|
||||||
]
|
]
|
||||||
}
|
}
|
||||||
|
|
||||||
To see all the available BIOS parameters on a node with iDRAC BMC, and also
|
See the `Known Issues`_ for a known issue with ``factory_reset`` clean step.
|
||||||
for additional details of BIOS configuration, see :doc:`/admin/bios`.
|
For additional details of BIOS configuration, see :doc:`/admin/bios`.
|
||||||
|
|
||||||
Inspect Interface
|
Inspect Interface
|
||||||
=================
|
=================
|
||||||
|
@ -624,6 +624,22 @@ into maintenance mode in Ironic. This issue can be worked around by changing
|
||||||
the Ironic power state poll interval to 70 seconds. See
|
the Ironic power state poll interval to 70 seconds. See
|
||||||
``[conductor]sync_power_state_interval`` in ``/etc/ironic/ironic.conf``.
|
``[conductor]sync_power_state_interval`` in ``/etc/ironic/ironic.conf``.
|
||||||
|
|
||||||
|
PXE reset with "factory_reset" BIOS clean step
|
||||||
|
----------------------------------------------
|
||||||
|
|
||||||
|
When using the ``UEFI boot mode``` with non-default PXE interface, the factory
|
||||||
|
reset can cause the PXE interface to be reset to default, which doesn't allow
|
||||||
|
the server to PXE boot for any further operations. This can cause a
|
||||||
|
``clean_failed`` state on the node or ``deploy_failed`` if you attempt to
|
||||||
|
deploy a node after this step. For now, the only solution is for the operator
|
||||||
|
to manually restore the PXE settings of the server for it to PXE boot again,
|
||||||
|
properly.
|
||||||
|
The problem is caused by the fact that with the ``UEFI boot mode``, the
|
||||||
|
``idrac`` uses BIOS settings to manage PXE configuration. This is not the case
|
||||||
|
with the ``BIOS boot mode`` where the PXE configuration is handled as a
|
||||||
|
configuration job on the integrated NIC itself, independently of the BIOS
|
||||||
|
settings.
|
||||||
|
|
||||||
.. _Ironic_RAID: https://docs.openstack.org/ironic/latest/admin/raid.html
|
.. _Ironic_RAID: https://docs.openstack.org/ironic/latest/admin/raid.html
|
||||||