Merge "[doc] Update power sync documentation"
This commit is contained in:
commit
495c0b88bd
doc/source/admin
@ -26,7 +26,7 @@ the services.
|
||||
Upgrade Guide <upgrade-guide>
|
||||
Security <security>
|
||||
Troubleshooting FAQ <troubleshooting>
|
||||
Power Sync with the Compute Service <power-sync>
|
||||
Power Synchronization <power-sync>
|
||||
Node Multi-Tenancy <node-multitenancy>
|
||||
Fast-Track Deployment <fast-track>
|
||||
Booting a Ramdisk or an ISO <ramdisk-boot>
|
||||
|
@ -1,6 +1,6 @@
|
||||
===================================
|
||||
Power Sync with the Compute Service
|
||||
===================================
|
||||
=====================
|
||||
Power Synchronization
|
||||
=====================
|
||||
|
||||
Baremetal Power Sync
|
||||
====================
|
||||
@ -10,8 +10,24 @@ value of the :oslo.config:option:`conductor.force_power_state_during_sync`
|
||||
option is set to ``true`` the power state in the database will be forced on
|
||||
the hardware and if it is set to ``false`` the hardware state will be forced
|
||||
on the database. If this periodic task is enabled, it runs at an interval
|
||||
defined by the :oslo.config:option:`conductor.sync_power_state_interval` config
|
||||
option for those nodes which are not in maintenance.
|
||||
defined by the :oslo.config:option:`conductor.sync_power_state_interval`
|
||||
config option for those nodes which are not in maintenance. The requests sent
|
||||
to Baseboard Management Controllers (BMCs) are done with a parallelism
|
||||
controlled by :oslo.config:option:`conductor.sync_power_state_workers`.
|
||||
The motivation to send out requests to BMCs in parallel is to handle
|
||||
misbehaving BMCs which may delay or even block the synchronization otherwise.
|
||||
|
||||
.. note::
|
||||
In deployments with many nodes and IPMI as the configured BMC protocol,
|
||||
the default values of a 60 seconds power sync interval and 8 worker
|
||||
threads may lead to a high rate of required retries due to client-side UDP
|
||||
packet loss (visible via the corresponding warnings in the conductor
|
||||
logs). While Ironic automatically retries to get the power status
|
||||
for the affected nodes, the failure rate may be reduced by increasing
|
||||
the power sync cycle, e.g. to 300 seconds, and/or by reducing the number
|
||||
of power sync workers, e.g. to 2. Pleae keep in mind, however, that
|
||||
depending on the concrete setup increasing the power sync interval may
|
||||
have an impact on other components relying on up-to-date power states.
|
||||
|
||||