Fix idrac-wsman BIOS step async error handling

Instead of using process_event('fail') use error_handlers,
otherwise in case of failure node gets stuck and fails
because of timeout, instead of failing earlier due to
step failure.

And improve coverage to test this error handling
and also happy paths.

Story: 2008307
Task: 41197
Change-Id: I1e957c2b526abc37920212b6431b11eedc9f89be
(cherry picked from commit 83ce7c4264)
This commit is contained in:
Aija Jauntēva 2020-10-02 11:04:01 -04:00
parent 4fd099345d
commit 6130dc15e0
3 changed files with 101 additions and 9 deletions

View File

@ -261,14 +261,18 @@ class DracWSManBIOS(base.BIOSInterface):
:param task: a TaskManager instance with node to act on
:param config_job: a python-dracclient Job object (named tuple)
"""
LOG.error("BIOS configuration job failed for node %(node)s. "
"Failed config job: %(config_job_id)s. "
"Message: '%(message)s'.",
{'node': task.node_uuid, 'config_job_id': config_job.id,
'message': config_job.message})
task.node.last_error = config_job.message
# tell conductor to handle failure of clean/deploy step
task.process_event('fail')
error_msg = (_("Failed config job: %(config_job_id)s. "
"Message: '%(message)s'.") %
{'config_job_id': config_job.id,
'message': config_job.message})
log_msg = ("BIOS configuration job failed for node %(node)s. "
"%(error)s " %
{'node': task.node.uuid,
'error': error_msg})
if task.node.clean_step:
manager_utils.cleaning_error_handler(task, log_msg, error_msg)
else:
manager_utils.deploying_error_handler(task, log_msg, error_msg)
def _resume_current_operation(self, task):
"""Continue cleaning/deployment of the node.

View File

@ -1,6 +1,6 @@
# -*- coding: utf-8 -*-
#
# Copyright (c) 2015-2016 Dell Inc. or its subsidiaries.
# Copyright (c) 2015-2021 Dell Inc. or its subsidiaries.
# All Rights Reserved.
#
# Licensed under the Apache License, Version 2.0 (the "License"); you may
@ -26,6 +26,7 @@ from dracclient import exceptions as drac_exceptions
from ironic.common import exception
from ironic.common import states
from ironic.conductor import task_manager
from ironic.conductor import utils as manager_utils
from ironic.drivers.modules import deploy_utils
from ironic.drivers.modules.drac import bios as drac_bios
from ironic.drivers.modules.drac import common as drac_common
@ -238,6 +239,85 @@ class DracWSManBIOSConfigurationTestCase(test_utils.BaseDracTest):
self.assertRaises(exception.DracOperationError,
task.driver.bios.factory_reset, task)
@mock.patch.object(manager_utils, 'notify_conductor_resume_clean',
autospec=True)
@mock.patch.object(drac_job, 'get_job', spec_set=True,
autospec=True)
def test__check_node_bios_jobs(self, mock_get_job,
mock_notify_conductor_resume_clean):
mock_job = mock.Mock()
mock_job.status = 'Completed'
mock_get_job.return_value = mock_job
with task_manager.acquire(self.context, self.node.uuid) as task:
driver_internal_info = task.node.driver_internal_info
driver_internal_info['bios_config_job_ids'] = ['123', '789']
task.node.driver_internal_info = driver_internal_info
task.node.clean_step = {'priority': 100, 'interface': 'bios',
'step': 'factory_reset', 'argsinfo': {}}
task.node.save()
mock_cache = mock.Mock()
task.driver.bios.cache_bios_settings = mock_cache
task.driver.bios._check_node_bios_jobs(task)
self.assertEqual([], task.node.driver_internal_info.get(
'bios_config_job_ids'))
mock_cache.assert_called_once_with(task)
mock_notify_conductor_resume_clean.assert_called_once_with(task)
@mock.patch.object(drac_job, 'get_job', spec_set=True,
autospec=True)
def test__check_node_bios_jobs_still_running(self, mock_get_job):
mock_job = mock.Mock()
mock_job.status = 'Running'
mock_get_job.return_value = mock_job
with task_manager.acquire(self.context, self.node.uuid) as task:
driver_internal_info = task.node.driver_internal_info
driver_internal_info['bios_config_job_ids'] = ['123']
task.node.driver_internal_info = driver_internal_info
task.node.save()
mock_resume = mock.Mock()
task.driver.bios._resume_current_operation = mock_resume
mock_cache = mock.Mock()
task.driver.bios.cache_bios_settings = mock_cache
task.driver.bios._check_node_bios_jobs(task)
self.assertEqual(['123'],
task.node.driver_internal_info.get(
'bios_config_job_ids'))
mock_cache.assert_not_called()
mock_resume.assert_not_called()
@mock.patch.object(manager_utils, 'cleaning_error_handler', autospec=True)
@mock.patch.object(drac_job, 'get_job', spec_set=True,
autospec=True)
def test__check_node_bios_jobs_failed(self, mock_get_job,
mock_cleaning_error_handler):
mock_job = mock.Mock()
mock_job.status = 'Failed'
mock_job.id = '123'
mock_job.message = 'Invalid'
mock_get_job.return_value = mock_job
with task_manager.acquire(self.context, self.node.uuid) as task:
driver_internal_info = task.node.driver_internal_info
driver_internal_info['bios_config_job_ids'] = ['123']
task.node.driver_internal_info = driver_internal_info
task.node.clean_step = {'priority': 100, 'interface': 'bios',
'step': 'factory_reset', 'argsinfo': {}}
task.node.save()
task.driver.bios._check_node_bios_jobs(task)
self.assertEqual([],
task.node.driver_internal_info.get(
'bios_config_job_ids'))
mock_cleaning_error_handler.assert_called_once_with(
task, mock.ANY, "Failed config job: 123. Message: 'Invalid'.")
class DracBIOSConfigurationTestCase(test_utils.BaseDracTest):

View File

@ -0,0 +1,8 @@
---
fixes:
- |
Fixes ``idrac-wsman`` BIOS ``apply_configuration`` and ``factory_reset``
clean and deploy steps to fail correctly in case of error when checking
completed jobs. Before the fix when BIOS job failed, then node clean or
deploy failed with timeout instead of actual error in cleaning or
deploying step.