Note on ilo firmware update swift url scheme

Follow up of fa0c3e75ac. Ilo
doc is updated with clarification on swift url scheme.

Change-Id: Icf6603800d7d23bcd07c1cde0cadf3f742454e32
This commit is contained in:
Debayan Ray 2016-03-30 23:19:06 -07:00
parent cdfa120e06
commit e52338ee2b

View File

@ -817,7 +817,7 @@ Supported **Manual** Cleaning Operations
Some devices firmware cannot be updated via this method, such as: storage
controllers, host bus adapters, disk drive firmware, network interfaces
and OA.
and Onboard Administrator (OA).
* iLO with firmware version 1.5 is minimally required to support all the
operations.
@ -1428,7 +1428,15 @@ All the fields in the firmware image block are mandatory.
This feature assumes that while using ``file`` url scheme the file path is
on the conductor controlling the node.
* Different firmware components that can be updated are:
.. note::
The ``swift`` url scheme assumes the swift account of the ``service``
project. The ``service`` project (tenant) is a special project created in
the Keystone system designed for the use of the core OpenStack services.
When Ironic makes use of Swift for storage purpose, the account is generally
``service`` and the container is generally ``ironic`` and ``ilo`` drivers
use a container named ``ironic_ilo_container`` for their own purpose.
* The firmware components that can be updated are:
``ilo``, ``cpld``, ``power_pic``, ``bios`` and ``chassis``.
* The firmware images will be updated in the order given by the operator. If
there is any error during processing of any of the given firmware images