Note on ilo firmware update swift url scheme
Follow up of fa0c3e75ac
. Ilo
doc is updated with clarification on swift url scheme.
Change-Id: Icf6603800d7d23bcd07c1cde0cadf3f742454e32
This commit is contained in:
parent
cdfa120e06
commit
e52338ee2b
@ -817,7 +817,7 @@ Supported **Manual** Cleaning Operations
|
||||
|
||||
Some devices firmware cannot be updated via this method, such as: storage
|
||||
controllers, host bus adapters, disk drive firmware, network interfaces
|
||||
and OA.
|
||||
and Onboard Administrator (OA).
|
||||
|
||||
* iLO with firmware version 1.5 is minimally required to support all the
|
||||
operations.
|
||||
@ -1428,7 +1428,15 @@ All the fields in the firmware image block are mandatory.
|
||||
This feature assumes that while using ``file`` url scheme the file path is
|
||||
on the conductor controlling the node.
|
||||
|
||||
* Different firmware components that can be updated are:
|
||||
.. note::
|
||||
The ``swift`` url scheme assumes the swift account of the ``service``
|
||||
project. The ``service`` project (tenant) is a special project created in
|
||||
the Keystone system designed for the use of the core OpenStack services.
|
||||
When Ironic makes use of Swift for storage purpose, the account is generally
|
||||
``service`` and the container is generally ``ironic`` and ``ilo`` drivers
|
||||
use a container named ``ironic_ilo_container`` for their own purpose.
|
||||
|
||||
* The firmware components that can be updated are:
|
||||
``ilo``, ``cpld``, ``power_pic``, ``bios`` and ``chassis``.
|
||||
* The firmware images will be updated in the order given by the operator. If
|
||||
there is any error during processing of any of the given firmware images
|
||||
|