.. _ilo: =========== iLO drivers =========== Overview ======== iLO drivers enable to take advantage of features of iLO management engine in HPE ProLiant servers. iLO drivers are targeted for HPE ProLiant Gen8 and Gen9 systems which have `iLO 4 management engine`_. From **Pike** release iLO drivers start supporting ProLiant Gen10 systems which have `iLO 5 management engine`_. iLO5 conforms to `Redfish`_ API and hence hardware type ``redfish`` (see :doc:`redfish`) is also an option for this kind of hardware but it will lack the iLO specific features. For more details and for up-to-date information (like tested platforms, known issues, etc), please check the `iLO driver wiki page `_. For enabling Gen10 systems and getting detailed information on Gen10 feature support in Ironic please check this `Gen10 wiki section`_. ProLiant hardware is supported by the ``ilo`` hardware type and the following classic drivers: * ``iscsi_ilo`` * ``agent_ilo`` * ``pxe_ilo`` .. note:: All HPE ProLiant servers support reference hardware type ``ipmi`` (see :doc:`ipmitool`). HPE ProLiant Gen10 servers also support hardware type ``redfish`` (see :doc:`redfish`). The ``iscsi_ilo`` and ``agent_ilo`` drivers provide security enhanced PXE-less deployment by using iLO virtual media to boot up the bare metal node. These drivers send management info through the management channel and separate it from the data channel which is used for deployment. ``iscsi_ilo`` and ``agent_ilo`` drivers use deployment ramdisk built from ``diskimage-builder``. The ``iscsi_ilo`` driver deploys from ironic conductor and supports both net-boot and local-boot of instance. ``agent_ilo`` deploys from bare metal node and supports both net-boot and local-boot of instance. ``pxe_ilo`` driver uses PXE/iSCSI for deployment (just like normal PXE driver) and deploys from ironic conductor. Additionally it supports automatic setting of requested boot mode from nova. This driver doesn't require iLO Advanced license. The hardware type ``ilo`` and iLO-based classic drivers support HPE server features like: * UEFI secure boot * Certificate based validation of iLO * Hardware based secure disk erase using Smart Storage Administrator (SSA) CLI * Out-of-band discovery of server attributes through hardware inspection * In-band RAID configuration * Firmware configuration and secure firmware update Hardware Interfaces ^^^^^^^^^^^^^^^^^^^ The ``ilo`` hardware type supports following hardware interfaces: * boot Supports ``ilo-virtual-media`` and ``ilo-pxe``. The default is ``ilo-virtual-media``. They can be enabled by using the ``[DEFAULT]enabled_boot_interfaces`` option in ``ironic.conf`` as given below: .. code-block:: ini [DEFAULT] enabled_hardware_types = ilo enabled_boot_interfaces = ilo-virtual-media,ilo-pxe * console Supports ``ilo`` and ``no-console``. The default is ``ilo``. They can be enabled by using the ``[DEFAULT]enabled_console_interfaces`` option in ``ironic.conf`` as given below: .. code-block:: ini [DEFAULT] enabled_hardware_types = ilo enabled_console_interfaces = ilo,no-console * inspect Supports ``ilo`` and ``inspector``. The default is ``ilo``. They can be enabled by using the ``[DEFAULT]enabled_inspect_interfaces`` option in ``ironic.conf`` as given below: .. code-block:: ini [DEFAULT] enabled_hardware_types = ilo enabled_inspect_interfaces = ilo,inspector .. note:: `Ironic Inspector `_ needs to be configured to use ``inspector`` as the inspect interface. * management Supports only ``ilo``. It can be enabled by using the ``[DEFAULT]enabled_management_interfaces`` option in ``ironic.conf`` as given below: .. code-block:: ini [DEFAULT] enabled_hardware_types = ilo enabled_management_interfaces = ilo * power Supports only ``ilo``. It can be enabled by using the ``[DEFAULT]enabled_power_interfaces`` option in ``ironic.conf`` as given below: .. code-block:: ini [DEFAULT] enabled_hardware_types = ilo enabled_power_interfaces = ilo * raid Supports ``agent`` and ``no-raid``. The default is ``no-raid``. They can be enabled by using the ``[DEFAULT]enabled_raid_interfaces`` option in ``ironic.conf`` as given below: .. code-block:: ini [DEFAULT] enabled_hardware_types = ilo enabled_raid_interfaces = agent,no-raid * storage Supports ``cinder`` and ``noop``. The default is ``noop``. They can be enabled by using the ``[DEFAULT]enabled_storage_interfaces`` option in ``ironic.conf`` as given below: .. code-block:: ini [DEFAULT] enabled_hardware_types = ilo enabled_storage_interfaces = cinder,noop .. note:: The storage interface ``cinder`` is supported only when corresponding boot interface of the ``ilo`` hardware type based node is ``ilo-pxe``. Please refer to :doc:`/admin/boot-from-volume` for configuring ``cinder`` as a storage interface. ``ilo`` hardware type supports all standard ``deploy`` and ``network`` interface implementations, see :ref:`enable-hardware-interfaces` for details. The following command can be used to enroll a ProLiant node with ``ilo`` hardware type: .. code-block:: console openstack baremetal node create --os-baremetal-api-version=1.31 \ --driver ilo \ --deploy-interface direct \ --raid-interface agent \ --driver-info ilo_address= \ --driver-info ilo_username= \ --driver-info ilo_password= \ --driver-info ilo_deploy_iso= Please refer to :doc:`/install/enabling-drivers` for detailed explanation of hardware type. To enable the same feature set as provided by all iLO classic drivers, apply the following configuration: .. code-block:: ini [DEFAULT] enabled_hardware_types = ilo enabled_boot_interfaces = ilo-virtual-media,ilo-pxe enabled_power_interfaces = ilo enabled_console_interfaces = ilo enabled_raid_interfaces = agent enabled_management_interfaces = ilo enabled_inspect_interfaces = ilo The following commands can be used to enroll a node with the same feature set as one of the classic drivers, but using the ``ilo`` hardware type: * ``iscsi_ilo``: .. code-block:: console openstack baremetal node create --os-baremetal-api-version=1.31 \ --driver ilo \ --deploy-interface iscsi \ --boot-interface ilo-virtual-media \ --driver-info ilo_address= \ --driver-info ilo_username= \ --driver-info ilo_password= \ --driver-info ilo_deploy_iso= * ``pxe_ilo``: .. code-block:: console openstack baremetal node create --os-baremetal-api-version=1.31 \ --driver ilo \ --deploy-interface iscsi \ --boot-interface ilo-pxe \ --driver-info ilo_address= \ --driver-info ilo_username= \ --driver-info ilo_password= \ --driver-info deploy_kernel= \ --driver-info deploy_ramdisk= * ``agent_ilo``: .. code-block:: console openstack baremetal node create --os-baremetal-api-version=1.31 \ --driver ilo \ --deploy-interface direct \ --boot-interface ilo-virtual-media \ --driver-info ilo_address= \ --driver-info ilo_username= \ --driver-info ilo_password= \ --driver-info ilo_deploy_iso= Prerequisites ============= * `proliantutils `_ is a python package which contains a set of modules for managing HPE ProLiant hardware. Install ``proliantutils`` module on the ironic conductor node. Minimum version required is 2.4.0:: $ pip install "proliantutils>=2.4.0" * ``ipmitool`` command must be present on the service node(s) where ``ironic-conductor`` is running. On most distros, this is provided as part of the ``ipmitool`` package. Please refer to `Hardware Inspection Support`_ for more information on recommended version. Different Configuration for ilo drivers ======================================= Glance Configuration ^^^^^^^^^^^^^^^^^^^^ 1. `Configure Glance image service with its storage backend as Swift `_. 2. Set a temp-url key for Glance user in Swift. For example, if you have configured Glance with user ``glance-swift`` and tenant as ``service``, then run the below command:: swift --os-username=service:glance-swift post -m temp-url-key:mysecretkeyforglance 3. Fill the required parameters in the ``[glance]`` section in ``/etc/ironic/ironic.conf``. Normally you would be required to fill in the following details:: [glance] swift_temp_url_key=mysecretkeyforglance swift_endpoint_url=https://10.10.1.10:8080 swift_api_version=v1 swift_account=AUTH_51ea2fb400c34c9eb005ca945c0dc9e1 swift_container=glance The details can be retrieved by running the below command: .. code-block:: bash $ swift --os-username=service:glance-swift stat -v | grep -i url StorageURL: http://10.10.1.10:8080/v1/AUTH_51ea2fb400c34c9eb005ca945c0dc9e1 Meta Temp-Url-Key: mysecretkeyforglance 4. Swift must be accessible with the same admin credentials configured in Ironic. For example, if Ironic is configured with the below credentials in ``/etc/ironic/ironic.conf``:: [keystone_authtoken] admin_password = password admin_user = ironic admin_tenant_name = service Ensure ``auth_version`` in ``keystone_authtoken`` to 2. Then, the below command should work.: .. code-block:: bash $ swift --os-username ironic --os-password password --os-tenant-name service --auth-version 2 stat Account: AUTH_22af34365a104e4689c46400297f00cb Containers: 2 Objects: 18 Bytes: 1728346241 Objects in policy "policy-0": 18 Bytes in policy "policy-0": 1728346241 Meta Temp-Url-Key: mysecretkeyforglance X-Timestamp: 1409763763.84427 X-Trans-Id: tx51de96a28f27401eb2833-005433924b Content-Type: text/plain; charset=utf-8 Accept-Ranges: bytes 5. Restart the Ironic conductor service:: $ service ironic-conductor restart Web server configuration on conductor ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ * The HTTP(S) web server can be configured in many ways. For apache web server on Ubuntu, refer `here `_ * Following config variables need to be set in ``/etc/ironic/ironic.conf``: * ``use_web_server_for_images`` in ``[ilo]`` section:: [ilo] use_web_server_for_images = True * ``http_url`` and ``http_root`` in ``[deploy]`` section:: [deploy] # Ironic compute node's http root path. (string value) http_root=/httpboot # Ironic compute node's HTTP server URL. Example: # http://192.1.2.3:8080 (string value) http_url=http://192.168.0.2:8080 ``use_web_server_for_images``: If the variable is set to ``false``, ``iscsi_ilo`` and ``agent_ilo`` uses swift containers to host the intermediate floppy image and the boot ISO. If the variable is set to ``true``, these drivers use the local web server for hosting the intermediate files. The default value for ``use_web_server_for_images`` is False. ``http_url``: The value for this variable is prefixed with the generated intermediate files to generate a URL which is attached in the virtual media. ``http_root``: It is the directory location to which ironic conductor copies the intermediate floppy image and the boot ISO. .. note:: HTTPS is strongly recommended over HTTP web server configuration for security enhancement. The ``iscsi_ilo`` and ``agent_ilo`` will send the instance's configdrive over an encrypted channel if web server is HTTPS enabled. Enable driver ============= 1. Build a deploy ISO (and kernel and ramdisk) image, see :ref:`deploy-ramdisk` 2. See `Glance Configuration`_ for configuring glance image service with its storage backend as ``swift``. 3. Upload this image to Glance:: glance image-create --name deploy-ramdisk.iso --disk-format iso --container-format bare < deploy-ramdisk.iso 4. Add the driver name to the list of ``enabled_drivers`` in ``/etc/ironic/ironic.conf``. For example, for `iscsi_ilo` driver:: enabled_drivers = fake,pxe_ipmitool,iscsi_ilo Similarly it can be added for ``agent_ilo`` and ``pxe_ilo`` drivers. 5. Restart the ironic conductor service:: $ service ironic-conductor restart Drivers ======= iscsi_ilo driver ^^^^^^^^^^^^^^^^ Overview ~~~~~~~~ ``iscsi_ilo`` driver was introduced as an alternative to ``pxe_ipmitool`` and ``pxe_ipminative`` drivers for HPE ProLiant servers. ``iscsi_ilo`` uses virtual media feature in iLO to boot up the bare metal node instead of using PXE or iPXE. Target Users ~~~~~~~~~~~~ * Users who do not want to use PXE/TFTP protocol in their data centers. * Users who have concerns with PXE protocol's security issues and want to have a security enhanced PXE-less deployment mechanism. The PXE driver passes management information in clear-text to the bare metal node. However, if swift proxy server and glance have HTTPS endpoints (See :ref:`EnableHTTPSinSwift`, :ref:`EnableHTTPSinGlance` for more information), the ``iscsi_ilo`` driver provides enhanced security by exchanging management information with swift and glance endpoints over HTTPS. The management information, deploy ramdisk and boot images for the instance will be retrieved over encrypted management network via iLO virtual media. Tested Platforms ~~~~~~~~~~~~~~~~ This driver should work on HPE ProLiant Gen7 servers with iLO 3, Gen8 and Gen9 servers with iLO 4 and Gen10 servers with iLO 5. It has been tested with the following servers: * ProLiant DL380 G7 * ProLiant DL380e Gen8 * ProLiant DL580 Gen8 UEFI * ProLiant DL180 Gen9 UEFI * ProLiant DL360 Gen9 UEFI * ProLiant DL380 Gen9 UEFI * ProLiant XL450 Gen9 UEFI * ProLiant DL360 Gen10 For more up-to-date information on server platform support info, refer `iLO driver wiki page `_. Features ~~~~~~~~ * PXE-less deploy with virtual media. * Automatic detection of current boot mode. * Automatic setting of the required boot mode, if UEFI boot mode is requested by the nova flavor's extra spec. * Supports booting the instance from virtual media (netboot) as well as booting locally from disk. By default, the instance will always boot from virtual media for partition images. * UEFI Boot Support * UEFI Secure Boot Support * Passing management information via secure, encrypted management network (virtual media) if swift proxy server and glance have HTTPS endpoints. See :ref:`EnableHTTPSinSwift`, :ref:`EnableHTTPSinGlance` for more information. User image provisioning is done using iSCSI over data network, so this driver has the benefit of security enhancement with the same performance. It segregates management info from data channel. * Supports both out-of-band and in-band cleaning operations. For more details, see :ref:`InbandvsOutOfBandCleaning`. * Remote Console * HW Sensors * Works well for machines with resource constraints (lesser amount of memory). * Support for out-of-band hardware inspection. * Swiftless deploy for intermediate images * HTTP(S) Based Deploy. * iLO drivers with standalone ironic. Requirements ~~~~~~~~~~~~ * **iLO 4** or **iLO 5 Advanced License** needs to be installed on iLO to enable Virtual Media Boot feature. * **Swift Object Storage Service** - iLO driver uses swift to store temporary FAT images as well as boot ISO images. * **Glance Image Service with swift configured as its backend** - When using ``iscsi_ilo`` driver, the image containing the deploy ramdisk is retrieved from swift directly by the iLO. Deploy Process ~~~~~~~~~~~~~~ Please refer to `Netboot with glance and swift`_ and `Localboot with glance and swift for partition images`_ for the deploy process of partition image and `Localboot with glance and swift`_ for the deploy process of whole disk image. Configuring and Enabling the driver ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ Please refer to `Glance Configuration`_ and `Enable driver`_. Registering ProLiant node in ironic ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ Nodes configured for iLO driver should have the ``driver`` property set to ``iscsi_ilo``. The following configuration values are also required in ``driver_info``: - ``ilo_address``: IP address or hostname of the iLO. - ``ilo_username``: Username for the iLO with administrator privileges. - ``ilo_password``: Password for the above iLO user. - ``ilo_deploy_iso``: The glance UUID of the deploy ramdisk ISO image. - ``ca_file``: (optional) CA certificate file to validate iLO. - ``client_port``: (optional) Port to be used for iLO operations if you are using a custom port on the iLO. Default port used is 443. - ``client_timeout``: (optional) Timeout for iLO operations. Default timeout is 60 seconds. - ``console_port``: (optional) Node's UDP port for console access. Any unused port on the ironic conductor node may be used. .. note:: To update SSL certificates into iLO, you can refer to `HPE Integrated Lights-Out Security Technology Brief `_. You can use iLO hostname or IP address as a 'Common Name (CN)' while generating Certificate Signing Request (CSR). Use the same value as `ilo_address` while enrolling node to Bare Metal service to avoid SSL certificate validation errors related to hostname mismatch. .. note:: If configuration values for ``ca_file``, ``client_port`` and ``client_timeout`` are not provided in the ``driver_info`` of the node, the corresponding config variables defined under ``[ilo]`` section in ironic.conf will be used. For example, you could run a similar command like below to enroll the ProLiant node:: openstack baremetal node create --driver iscsi_ilo \ --driver-info ilo_address= \ --driver-info ilo_username= \ --driver-info ilo_password= \ --driver-info ilo_deploy_iso= Boot modes ~~~~~~~~~~ Please refer to `Boot mode support`_ for more information. UEFI Secure Boot ~~~~~~~~~~~~~~~~ Please refer to `UEFI Secure Boot Support`_ for more information. Node cleaning ~~~~~~~~~~~~~ Please refer to `Node Cleaning Support`_ for more information. Hardware Inspection ~~~~~~~~~~~~~~~~~~~ Please refer to `Hardware Inspection Support`_ for more information. Swiftless deploy for intermediate deploy and boot images ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ Please refer to `Swiftless deploy for intermediate images`_ for more information. HTTP(S) Based Deploy ~~~~~~~~~~~~~~~~~~~~ Please refer to `HTTP(S) Based Deploy Support`_ for more information. iLO drivers with standalone ironic ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ Please refer to `Support for iLO drivers with Standalone Ironic`_ for more information. RAID Configuration ~~~~~~~~~~~~~~~~~~ Please refer to `RAID Support`_ for more information. agent_ilo driver ^^^^^^^^^^^^^^^^ Overview ~~~~~~~~ ``agent_ilo`` driver was introduced as an alternative to ``agent_ipmitool`` and ``agent_ipminative`` drivers for HPE ProLiant servers. ``agent_ilo`` driver uses virtual media feature in HPE ProLiant bare metal servers to boot up the Ironic Python Agent (IPA) on the bare metal node instead of using PXE. For more information on IPA, refer https://wiki.openstack.org/wiki/Ironic-python-agent. Target Users ~~~~~~~~~~~~ * Users who do not want to use PXE/TFTP protocol on their data centres. * Users who have concerns on PXE based agent driver's security and want to have a security enhanced PXE-less deployment mechanism. The PXE based agent drivers pass management information in clear-text to the bare metal node. However, if swift proxy server and glance have HTTPS endpoints (See :ref:`EnableHTTPSinSwift`, :ref:`EnableHTTPSinGlance` for more information), the ``agent_ilo`` driver provides enhanced security by exchanging authtoken and management information with swift and glance endpoints over HTTPS. The management information and deploy ramdisk will be retrieved over encrypted management network via iLO. Tested Platforms ~~~~~~~~~~~~~~~~ This driver should work on HPE ProLiant Gen7 servers with iLO 3, Gen8 and Gen9 servers with iLO 4 and Gen10 servers with iLO 5. It has been tested with the following servers: * ProLiant DL380 G7 * ProLiant DL380e Gen8 * ProLiant DL580e Gen8 * ProLiant DL360 Gen9 UEFI * ProLiant DL380 Gen9 UEFI * ProLiant DL180 Gen9 UEFI * ProLiant XL450 Gen9 UEFI * ProLiant DL360 Gen10 For more up-to-date information, check the `iLO driver wiki page `_. Features ~~~~~~~~ * PXE-less deploy with virtual media using Ironic Python Agent(IPA). * Support for out-of-band cleaning operations. * Remote Console * HW Sensors * IPA runs on the bare metal node and pulls the image directly from swift. * Supports booting the instance from virtual media (netboot) as well as booting locally from disk. By default, the instance will always boot from virtual media for partition images. * Segregates management info from data channel. * UEFI Boot Support * UEFI Secure Boot Support * Support to use default in-band cleaning operations supported by Ironic Python Agent. For more details, see :ref:`InbandvsOutOfBandCleaning`. * Support for out-of-band hardware inspection. * Swiftless deploy for intermediate images. * HTTP(S) Based Deploy. * iLO drivers with standalone ironic. * Supports tenant network isolation for node instances provisioned for vlan type networks. Requirements ~~~~~~~~~~~~ * **iLO 4** or **iLO 5 Advanced License** needs to be installed on iLO to enable Virtual Media Boot feature. * **Swift Object Storage Service** - iLO driver uses swift to store temporary FAT images as well as boot ISO images. * **Glance Image Service with swift configured as its backend** - When using ``agent_ilo`` driver, the image containing the agent is retrieved from swift directly by the iLO. Deploy Process ~~~~~~~~~~~~~~ Please refer to `Netboot with glance and swift`_ and `Localboot with glance and swift for partition images`_ for the deploy process of partition image and `Localboot with glance and swift`_ for the deploy process of whole disk image. Configuring and Enabling the driver ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ Please refer to `Glance Configuration`_ and `Enable driver`_. Registering ProLiant node in ironic ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ Nodes configured for iLO driver should have the ``driver`` property set to ``agent_ilo``. The following configuration values are also required in ``driver_info``: - ``ilo_address``: IP address or hostname of the iLO. - ``ilo_username``: Username for the iLO with administrator privileges. - ``ilo_password``: Password for the above iLO user. - ``ilo_deploy_iso``: The glance UUID of the deploy ramdisk ISO image. - ``ca_file``: (optional) CA certificate file to validate iLO. - ``client_port``: (optional) Port to be used for iLO operations if you are using a custom port on the iLO. Default port used is 443. - ``client_timeout``: (optional) Timeout for iLO operations. Default timeout is 60 seconds. - ``console_port``: (optional) Node's UDP port for console access. Any unused port on the ironic conductor node may be used. .. note:: To update SSL certificates into iLO, you can refer to `HPE Integrated Lights-Out Security Technology Brief `_. You can use iLO hostname or IP address as a 'Common Name (CN)' while generating Certificate Signing Request (CSR). Use the same value as `ilo_address` while enrolling node to Bare Metal service to avoid SSL certificate validation errors related to hostname mismatch. .. note:: If configuration values for ``ca_file``, ``client_port`` and ``client_timeout`` are not provided in the ``driver_info`` of the node, the corresponding config variables defined under ``[ilo]`` section in ironic.conf will be used. For example, you could run a similar command like below to enroll the ProLiant node:: openstack baremetal node create --driver agent_ilo \ --driver-info ilo_address= \ --driver-info ilo_username= \ --driver-info ilo_password= \ --driver-info ilo_deploy_iso= Boot modes ~~~~~~~~~~ Please refer to `Boot mode support`_ for more information. UEFI Secure Boot ~~~~~~~~~~~~~~~~ Please refer to `UEFI Secure Boot Support`_ for more information. Node Cleaning ~~~~~~~~~~~~~ Please refer to `Node Cleaning Support`_ for more information. Hardware Inspection ~~~~~~~~~~~~~~~~~~~ Please refer to `Hardware Inspection Support`_ for more information. Swiftless deploy for intermediate deploy and boot images ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ Please refer to `Swiftless deploy for intermediate images`_ for more information. HTTP(S) Based Deploy ~~~~~~~~~~~~~~~~~~~~ Please refer to `HTTP(S) Based Deploy Support`_ for more information. iLO drivers with standalone ironic ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ Please refer to `Support for iLO drivers with Standalone Ironic`_ for more information. RAID Configuration ~~~~~~~~~~~~~~~~~~ Please refer to `RAID Support`_ for more information. pxe_ilo driver ^^^^^^^^^^^^^^ Overview ~~~~~~~~ ``pxe_ilo`` driver uses PXE/iSCSI (just like ``pxe_ipmitool`` driver) to deploy the image and uses iLO to do power and management operations on the bare metal node(instead of using IPMI). Target Users ~~~~~~~~~~~~ * Users who want to use PXE/iSCSI for deployment in their environment or who don't have Advanced License in their iLO. * Users who don't want to configure boot mode manually on the bare metal node. Tested Platforms ~~~~~~~~~~~~~~~~ This driver should work on HPE ProLiant Gen7 servers with iLO 3, Gen8 and Gen9 servers with iLO 4 and Gen10 servers with iLO 5. It has been tested with the following servers: * ProLiant DL380 G7 * ProLiant DL380e Gen8 * ProLiant DL380e Gen8 * ProLiant DL580 Gen8 (BIOS/UEFI) * ProLiant DL360 Gen9 UEFI * ProLiant DL380 Gen9 UEFI * ProLiant XL450 Gen9 UEFI * ProLiant DL360 Gen10 For more up-to-date information, check the `iLO driver wiki page `_. Features ~~~~~~~~ * Automatic detection of current boot mode. * Automatic setting of the required boot mode, if UEFI boot mode is requested by the nova flavor's extra spec. * Supports both out-of-band and in-band cleaning operations. For more details, see :ref:`InbandvsOutOfBandCleaning`. * Support for out-of-band hardware inspection. * Supports UEFI Boot mode * Supports UEFI Secure Boot * HTTP(S) Based Deploy. Requirements ~~~~~~~~~~~~ None. Configuring and Enabling the driver ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ 1. Build a deploy image, see :ref:`deploy-ramdisk` 2. Upload this image to glance:: glance image-create --name deploy-ramdisk.kernel --disk-format aki --container-format aki < deploy-ramdisk.kernel glance image-create --name deploy-ramdisk.initramfs --disk-format ari --container-format ari < deploy-ramdisk.initramfs 3. Add ``pxe_ilo`` to the list of ``enabled_drivers`` in ``/etc/ironic/ironic.conf``. For example::: enabled_drivers = fake,pxe_ipmitool,pxe_ilo 4. Restart the ironic conductor service:: service ironic-conductor restart Registering ProLiant node in ironic ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ Nodes configured for iLO driver should have the ``driver`` property set to ``pxe_ilo``. The following configuration values are also required in ``driver_info``: - ``ilo_address``: IP address or hostname of the iLO. - ``ilo_username``: Username for the iLO with administrator privileges. - ``ilo_password``: Password for the above iLO user. - ``deploy_kernel``: The glance UUID of the deployment kernel. - ``deploy_ramdisk``: The glance UUID of the deployment ramdisk. - ``ca_file``: (optional) CA certificate file to validate iLO. - ``client_port``: (optional) Port to be used for iLO operations if you are using a custom port on the iLO. Default port used is 443. - ``client_timeout``: (optional) Timeout for iLO operations. Default timeout is 60 seconds. - ``console_port``: (optional) Node's UDP port for console access. Any unused port on the ironic conductor node may be used. .. note:: To update SSL certificates into iLO, you can refer to `HPE Integrated Lights-Out Security Technology Brief `_. You can use iLO hostname or IP address as a 'Common Name (CN)' while generating Certificate Signing Request (CSR). Use the same value as `ilo_address` while enrolling node to Bare Metal service to avoid SSL certificate validation errors related to hostname mismatch. .. note:: If configuration values for ``ca_file``, ``client_port`` and ``client_timeout`` are not provided in the ``driver_info`` of the node, the corresponding config variables defined under ``[ilo]`` section in ironic.conf will be used. For example, you could run a similar command like below to enroll the ProLiant node:: openstack baremetal node create --driver pxe_ilo \ --driver-info ilo_address= \ --driver-info ilo_username= \ --driver-info ilo_password= \ --driver-info deploy_kernel= \ --driver-info deploy_ramdisk= Boot modes ~~~~~~~~~~ Please refer to `Boot mode support`_ for more information. UEFI Secure Boot ~~~~~~~~~~~~~~~~ Please refer to `UEFI Secure Boot Support`_ for more information. Node Cleaning ~~~~~~~~~~~~~ Please refer to `Node Cleaning Support`_ for more information. Hardware Inspection ~~~~~~~~~~~~~~~~~~~ Please refer to `Hardware Inspection Support`_ for more information. HTTP(S) Based Deploy ~~~~~~~~~~~~~~~~~~~~ Please refer to `HTTP(S) Based Deploy Support`_ for more information. iLO drivers with standalone ironic ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ Please refer to `Support for iLO drivers with Standalone Ironic`_ for more information. RAID Configuration ~~~~~~~~~~~~~~~~~~ Please refer to `RAID Support`_ for more information. Functionalities across drivers ============================== Boot mode support ^^^^^^^^^^^^^^^^^ The hardware type ``ilo`` and iLO-based classic drivers support automatic detection and setting of boot mode (Legacy BIOS or UEFI). * When boot mode capability is not configured: - If config variable ``default_boot_mode`` in ``[ilo]`` section of ironic configuration file is set to either 'bios' or 'uefi', then iLO drivers use that boot mode for provisioning the baremetal ProLiant servers. - If the pending boot mode is set on the node then iLO drivers use that boot mode for provisioning the baremetal ProLiant servers. - If the pending boot mode is not set on the node then iLO drivers use 'uefi' boot mode for UEFI capable servers and "bios" when UEFI is not supported. * When boot mode capability is configured, the driver sets the pending boot mode to the configured value. * Only one boot mode (either ``uefi`` or ``bios``) can be configured for the node. * If the operator wants a node to boot always in ``uefi`` mode or ``bios`` mode, then they may use ``capabilities`` parameter within ``properties`` field of an ironic node. To configure a node in ``uefi`` mode, then set ``capabilities`` as below:: openstack baremetal node set --property capabilities='boot_mode:uefi' Nodes having ``boot_mode`` set to ``uefi`` may be requested by adding an ``extra_spec`` to the nova flavor:: nova flavor-key ironic-test-3 set capabilities:boot_mode="uefi" nova boot --flavor ironic-test-3 --image test-image instance-1 If ``capabilities`` is used in ``extra_spec`` as above, nova scheduler (``ComputeCapabilitiesFilter``) will match only ironic nodes which have the ``boot_mode`` set appropriately in ``properties/capabilities``. It will filter out rest of the nodes. The above facility for matching in nova can be used in heterogeneous environments where there is a mix of ``uefi`` and ``bios`` machines, and operator wants to provide a choice to the user regarding boot modes. If the flavor doesn't contain ``boot_mode`` then nova scheduler will not consider boot mode as a placement criteria, hence user may get either a BIOS or UEFI machine that matches with user specified flavors. The automatic boot ISO creation for UEFI boot mode has been enabled in Kilo. The manual creation of boot ISO for UEFI boot mode is also supported. For the latter, the boot ISO for the deploy image needs to be built separately and the deploy image's ``boot_iso`` property in glance should contain the glance UUID of the boot ISO. For building boot ISO, add ``iso`` element to the diskimage-builder command to build the image. For example:: disk-image-create ubuntu baremetal iso .. _`iLO UEFI Secure Boot Support`: UEFI Secure Boot Support ^^^^^^^^^^^^^^^^^^^^^^^^ The hardware type ``ilo`` and iLO-based classic drivers support secure boot deploy. The UEFI secure boot can be configured in ironic by adding ``secure_boot`` parameter in the ``capabilities`` parameter within ``properties`` field of an ironic node. ``secure_boot`` is a boolean parameter and takes value as ``true`` or ``false``. To enable ``secure_boot`` on a node add it to ``capabilities`` as below:: openstack baremetal node set --property capabilities='secure_boot:true' Alternatively see `Hardware Inspection Support`_ to know how to automatically populate the secure boot capability. Nodes having ``secure_boot`` set to ``true`` may be requested by adding an ``extra_spec`` to the nova flavor:: nova flavor-key ironic-test-3 set capabilities:secure_boot="true" nova boot --flavor ironic-test-3 --image test-image instance-1 If ``capabilities`` is used in ``extra_spec`` as above, nova scheduler (``ComputeCapabilitiesFilter``) will match only ironic nodes which have the ``secure_boot`` set appropriately in ``properties/capabilities``. It will filter out rest of the nodes. The above facility for matching in nova can be used in heterogeneous environments where there is a mix of machines supporting and not supporting UEFI secure boot, and operator wants to provide a choice to the user regarding secure boot. If the flavor doesn't contain ``secure_boot`` then nova scheduler will not consider secure boot mode as a placement criteria, hence user may get a secure boot capable machine that matches with user specified flavors but deployment would not use its secure boot capability. Secure boot deploy would happen only when it is explicitly specified through flavor. Use element ``ubuntu-signed`` or ``fedora`` to build signed deploy iso and user images from `diskimage-builder `_. Please refer to :ref:`deploy-ramdisk` for more information on building deploy ramdisk. The below command creates files named cloud-image-boot.iso, cloud-image.initrd, cloud-image.vmlinuz and cloud-image.qcow2 in the current working directory:: cd ./bin/disk-image-create -o cloud-image ubuntu-signed baremetal iso .. note:: In UEFI secure boot, digitally signed bootloader should be able to validate digital signatures of kernel during boot process. This requires that the bootloader contains the digital signatures of the kernel. For ``iscsi_ilo`` driver, it is recommended that ``boot_iso`` property for user image contains the glance UUID of the boot ISO. If ``boot_iso`` property is not updated in glance for the user image, it would create the ``boot_iso`` using bootloader from the deploy iso. This ``boot_iso`` will be able to boot the user image in UEFI secure boot environment only if the bootloader is signed and can validate digital signatures of user image kernel. Ensure the public key of the signed image is loaded into bare metal to deploy signed images. For HPE ProLiant Gen9 servers, one can enroll public key using iLO System Utilities UI. Please refer to section ``Accessing Secure Boot options`` in `HP UEFI System Utilities User Guide `_. One can also refer to white paper on `Secure Boot for Linux on HP ProLiant servers `_ for additional details. For more up-to-date information, refer `iLO driver wiki page `_ .. _ilo_node_cleaning: Node Cleaning Support ^^^^^^^^^^^^^^^^^^^^^ The hardware type ``ilo`` and iLO-based classic drivers support node cleaning. For more information on node cleaning, see :ref:`cleaning` Supported **Automated** Cleaning Operations ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ * The automated cleaning operations supported are: * ``reset_bios_to_default``: Resets system ROM settings to default. By default, enabled with priority 10. This clean step is supported only on Gen9 and above servers. * ``reset_secure_boot_keys_to_default``: Resets secure boot keys to manufacturer's defaults. This step is supported only on Gen9 and above servers. By default, enabled with priority 20 . * ``reset_ilo_credential``: Resets the iLO password, if ``ilo_change_password`` is specified as part of node's driver_info. By default, enabled with priority 30. * ``clear_secure_boot_keys``: Clears all secure boot keys. This step is supported only on Gen9 and above servers. By default, this step is disabled. * ``reset_ilo``: Resets the iLO. By default, this step is disabled. * ``erase_devices``: An inband clean step that performs disk erase on all the disks including the disks visible to OS as well as the raw disks visible to Smart Storage Administrator (SSA). This step supports erasing of the raw disks visible to SSA in Proliant servers only with the ramdisk created using diskimage-builder from Ocata release. By default, this step is disabled. See `Disk Erase Support`_ for more details. * For in-band cleaning operations supported by ``agent_ilo`` driver, see :ref:`InbandvsOutOfBandCleaning`. * All the automated cleaning steps have an explicit configuration option for priority. In order to disable or change the priority of the automated clean steps, respective configuration option for priority should be updated in ironic.conf. * Updating clean step priority to 0, will disable that particular clean step and will not run during automated cleaning. * Configuration Options for the automated clean steps are listed under ``[ilo]`` and ``[deploy]`` section in ironic.conf :: [ilo] clean_priority_reset_ilo=0 clean_priority_reset_bios_to_default=10 clean_priority_reset_secure_boot_keys_to_default=20 clean_priority_clear_secure_boot_keys=0 clean_priority_reset_ilo_credential=30 [deploy] erase_devices_priority=0 For more information on node automated cleaning, see :ref:`automated_cleaning` Supported **Manual** Cleaning Operations ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ * The manual cleaning operations supported are: ``activate_license``: Activates the iLO Advanced license. This is an out-of-band manual cleaning step associated with the ``management`` interface. See `Activating iLO Advanced license as manual clean step`_ for user guidance on usage. Please note that this operation cannot be performed using virtual media based drivers like ``iscsi_ilo`` and ``agent_ilo`` as they need this type of advanced license already active to use virtual media to boot into to start cleaning operation. Virtual media is an advanced feature. If an advanced license is already active and the user wants to overwrite the current license key, for example in case of a multi-server activation key delivered with a flexible-quantity kit or after completing an Activation Key Agreement (AKA), then these drivers can still be used for executing this cleaning step. ``update_firmware``: Updates the firmware of the devices. Also an out-of-band step associated with the ``management`` interface. See `Initiating firmware update as manual clean step`_ for user guidance on usage. The supported devices for firmware update are: ``ilo``, ``cpld``, ``power_pic``, ``bios`` and ``chassis``. Please refer to below table for their commonly used descriptions. .. csv-table:: :header: "Device", "Description" :widths: 30, 80 "``ilo``", "BMC for HPE ProLiant servers" "``cpld``", "System programmable logic device" "``power_pic``", "Power management controller" "``bios``", "HPE ProLiant System ROM" "``chassis``", "System chassis device" Some devices firmware cannot be updated via this method, such as: storage controllers, host bus adapters, disk drive firmware, network interfaces and Onboard Administrator (OA). * iLO with firmware version 1.5 is minimally required to support all the operations. For more information on node manual cleaning, see :ref:`manual_cleaning` .. _ilo-inspection: Hardware Inspection Support ^^^^^^^^^^^^^^^^^^^^^^^^^^^ The hardware type ``ilo`` and iLO-based classic drivers support hardware inspection. .. note:: * The disk size is returned by RIBCL/RIS only when RAID is preconfigured on the storage. If the storage is Direct Attached Storage, then RIBCL/RIS fails to get the disk size. * The SNMPv3 inspection gets disk size for all types of storages. If RIBCL/RIS is unable to get disk size and SNMPv3 inspection is requested, the proliantutils does SNMPv3 inspection to get the disk size. If proliantutils is unable to get the disk size, it raises an error. This feature is available in proliantutils release version >= 2.2.0. * The iLO must be updated with SNMPv3 authentication details. Pleae refer to the section `SNMPv3 Authentication` in `HPE iLO4 User Guide`_ for setting up authentication details on iLO. The following parameters are mandatory to be given in driver_info for SNMPv3 inspection: * ``snmp_auth_user`` : The SNMPv3 user. * ``snmp_auth_prot_password`` : The auth protocol pass phrase. * ``snmp_auth_priv_password`` : The privacy protocol pass phrase. The following parameters are optional for SNMPv3 inspection: * ``snmp_auth_protocol`` : The Auth Protocol. The valid values are "MD5" and "SHA". The iLO default value is "MD5". * ``snmp_auth_priv_protocol`` : The Privacy protocol. The valid values are "AES" and "DES". The iLO default value is "DES". The inspection process will discover the following essential properties (properties required for scheduling deployment): * ``memory_mb``: memory size * ``cpus``: number of cpus * ``cpu_arch``: cpu architecture * ``local_gb``: disk size Inspection can also discover the following extra capabilities for iLO drivers: * ``ilo_firmware_version``: iLO firmware version * ``rom_firmware_version``: ROM firmware version * ``secure_boot``: secure boot is supported or not. The possible values are 'true' or 'false'. The value is returned as 'true' if secure boot is supported by the server. * ``server_model``: server model * ``pci_gpu_devices``: number of gpu devices connected to the bare metal. * ``nic_capacity``: the max speed of the embedded NIC adapter. * ``sriov_enabled``: true, if server has the SRIOV supporting NIC. * ``has_rotational``: true, if server has HDD disk. * ``has_ssd``: true, if server has SSD disk. * ``has_nvme_ssd``: true, if server has NVME SSD disk. * ``cpu_vt``: true, if server supports cpu virtualization. * ``hardware_supports_raid``: true, if RAID can be configured on the server using RAID controller. * ``nvdimm_n``: true, if server has NVDIMM_N type of persistent memory. * ``persistent_memory``: true, if server has persistent memory. * ``logical_nvdimm_n``: true, if server has logical NVDIMM_N configured. * ``rotational_drive__rpm``: The capabilities ``rotational_drive_4800_rpm``, ``rotational_drive_5400_rpm``, ``rotational_drive_7200_rpm``, ``rotational_drive_10000_rpm`` and ``rotational_drive_15000_rpm`` are set to true if the server has HDD drives with speed of 4800, 5400, 7200, 10000 and 15000 rpm respectively. * ``logical_raid_level_``: The capabilities ``logical_raid_level_0``, ``logical_raid_level_1``, ``logical_raid_level_2``, ``logical_raid_level_5``, ``logical_raid_level_6``, ``logical_raid_level_10``, ``logical_raid_level_50`` and ``logical_raid_level_60`` are set to true if any of the raid levels among 0, 1, 2, 5, 6, 10, 50 and 60 are configured on the system. .. note:: * The capability ``nic_capacity`` can only be discovered if ipmitool version >= 1.8.15 is used on the conductor. The latest version can be downloaded from `here `__. * The iLO firmware version needs to be 2.10 or above for nic_capacity to be discovered. The operator can specify these capabilities in nova flavor for node to be selected for scheduling:: nova flavor-key my-baremetal-flavor set capabilities:server_model=" Gen8" nova flavor-key my-baremetal-flavor set capabilities:nic_capacity="10Gb" nova flavor-key my-baremetal-flavor set capabilities:ilo_firmware_version=" 2.10" nova flavor-key my-baremetal-flavor set capabilities:has_ssd="true" See :ref:`capabilities-discovery` for more details and examples. Swiftless deploy for intermediate images ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ The hardware type ``ilo`` with ``ilo-virtual-media`` as boot interface and virtual media based classical drivers (``iscsi_ilo`` and ``agent_ilo``) can deploy and boot the server with and without ``swift`` being used for hosting the intermediate temporary floppy image (holding metadata for deploy kernel and ramdisk) and the boot ISO. A local HTTP(S) web server on each conductor node needs to be configured. Please refer to `Web server configuration on conductor`_ for more information. The HTTPS web server needs to be enabled (instead of HTTP web server) in order to send management information and images in encrypted channel over HTTPS. .. note:: This feature assumes that the user inputs are on Glance which uses swift as backend. If swift dependency has to be eliminated, please refer to `HTTP(S) Based Deploy Support`_ also. Deploy Process ~~~~~~~~~~~~~~ Please refer to `Netboot in swiftless deploy for intermediate images`_ for partition image support and `Localboot in swiftless deploy for intermediate images`_ for whole disk image support. HTTP(S) Based Deploy Support ^^^^^^^^^^^^^^^^^^^^^^^^^^^^ The user input for the images given in ``driver_info`` like ``ilo_deploy_iso``, ``deploy_kernel`` and ``deploy_ramdisk`` and in ``instance_info`` like ``image_source``, ``kernel``, ``ramdisk`` and ``ilo_boot_iso`` may also be given as HTTP(S) URLs. The HTTP(S) web server can be configured in many ways. For the Apache web server on Ubuntu, refer `here `_. The web server may reside on a different system than the conductor nodes, but its URL must be reachable by the conductor and the bare metal nodes. Deploy Process ~~~~~~~~~~~~~~ Please refer to `Netboot with HTTP(S) based deploy`_ for partition image boot and `Localboot with HTTP(S) based deploy`_ for whole disk image boot. Support for iLO drivers with Standalone Ironic ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ It is possible to use ironic as standalone services without other OpenStack services. The ``ilo`` hardware type and the iLO-based classic drivers can be used in standalone ironic. This feature is referred to as ``iLO drivers with standalone ironic`` in this document. Configuration ~~~~~~~~~~~~~ The HTTP(S) web server needs to be configured as described in `HTTP(S) Based Deploy Support`_ and `Web server configuration on conductor`_ needs to be configured for hosting intermediate images on conductor as described in `Swiftless deploy for intermediate images`_. Deploy Process ~~~~~~~~~~~~~~ ``iscsi_ilo`` and ``agent_ilo`` supports both netboot and localboot. Please refer to `Netboot in standalone ironic`_ and `Localboot in standalone ironic`_ for details of deploy process for netboot and localboot respectively. For ``pxe_ilo``, the deploy process is same as native ``pxe_ipmitool`` driver. Deploy Process ============== Netboot with glance and swift ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ .. seqdiag:: :scale: 80 diagram { Glance; Conductor; Baremetal; Swift; IPA; iLO; activation = none; span_height = 1; edge_length = 250; default_note_color = white; default_fontsize = 14; Conductor -> iLO [label = "Powers off the node"]; Conductor -> Glance [label = "Download user image"]; Conductor -> Glance [label = "Get the metadata for deploy ISO"]; Conductor -> Conductor [label = "Generates swift tempURL for deploy ISO"]; Conductor -> Conductor [label = "Creates the FAT32 image containing Ironic API URL and driver name"]; Conductor -> Swift [label = "Uploads the FAT32 image"]; Conductor -> Conductor [label = "Generates swift tempURL for FAT32 image"]; Conductor -> iLO [label = "Attaches the FAT32 image swift tempURL as virtual media floppy"]; Conductor -> iLO [label = "Attaches the deploy ISO swift tempURL as virtual media CDROM"]; Conductor -> iLO [label = "Sets one time boot to CDROM"]; Conductor -> iLO [label = "Reboot the node"]; iLO -> Swift [label = "Downloads deploy ISO"]; Baremetal -> iLO [label = "Boots deploy kernel/ramdisk from iLO virtual media CDROM"]; IPA -> Conductor [label = "Lookup node"]; Conductor -> IPA [label = "Provides node UUID"]; IPA -> Conductor [label = "Heartbeat"]; Conductor -> IPA [label = "Exposes the disk over iSCSI"]; Conductor -> Conductor [label = "Connects to bare metal's disk over iSCSI and writes image"]; Conductor -> Conductor [label = "Generates the boot ISO"]; Conductor -> Swift [label = "Uploads the boot ISO"]; Conductor -> Conductor [label = "Generates swift tempURL for boot ISO"]; Conductor -> iLO [label = "Attaches boot ISO swift tempURL as virtual media CDROM"]; Conductor -> iLO [label = "Sets boot device to CDROM"]; Conductor -> IPA [label = "Power off the node"]; Conductor -> iLO [label = "Power on the node"]; iLO -> Swift [label = "Downloads boot ISO"]; iLO -> Baremetal [label = "Boots the instance kernel/ramdisk from iLO virtual media CDROM"]; Baremetal -> Baremetal [label = "Instance kernel finds root partition and continues booting from disk"]; } Localboot with glance and swift for partition images ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ .. seqdiag:: :scale: 80 diagram { Glance; Conductor; Baremetal; Swift; IPA; iLO; activation = none; span_height = 1; edge_length = 250; default_note_color = white; default_fontsize = 14; Conductor -> iLO [label = "Powers off the node"]; Conductor -> Glance [label = "Get the metadata for deploy ISO"]; Glance -> Conductor [label = "Returns the metadata for deploy ISO"]; Conductor -> Conductor [label = "Generates swift tempURL for deploy ISO"]; Conductor -> Conductor [label = "Creates the FAT32 image containing ironic API URL and driver name"]; Conductor -> Swift [label = "Uploads the FAT32 image"]; Conductor -> Conductor [label = "Generates swift tempURL for FAT32 image"]; Conductor -> iLO [label = "Attaches the FAT32 image swift tempURL as virtual media floppy"]; Conductor -> iLO [label = "Attaches the deploy ISO swift tempURL as virtual media CDROM"]; Conductor -> iLO [label = "Sets one time boot to CDROM"]; Conductor -> iLO [label = "Reboot the node"]; iLO -> Swift [label = "Downloads deploy ISO"]; Baremetal -> iLO [label = "Boots deploy kernel/ramdisk from iLO virtual media CDROM"]; IPA -> Conductor [label = "Lookup node"]; Conductor -> IPA [label = "Provides node UUID"]; IPA -> Conductor [label = "Heartbeat"]; Conductor -> IPA [label = "Sends the user image HTTP(S) URL"]; IPA -> Swift [label = "Retrieves the user image on bare metal"]; IPA -> IPA [label = "Writes user image to root partition"]; IPA -> IPA [label = "Installs boot loader"]; IPA -> Conductor [label = "Heartbeat"]; Conductor -> Baremetal [label = "Sets boot device to disk"]; Conductor -> IPA [label = "Power off the node"]; Conductor -> iLO [label = "Power on the node"]; Baremetal -> Baremetal [label = "Boot user image from disk"]; } Localboot with glance and swift ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ .. seqdiag:: :scale: 80 diagram { Glance; Conductor; Baremetal; Swift; IPA; iLO; activation = none; span_height = 1; edge_length = 250; default_note_color = white; default_fontsize = 14; Conductor -> iLO [label = "Powers off the node"]; Conductor -> Glance [label = "Get the metadata for deploy ISO"]; Glance -> Conductor [label = "Returns the metadata for deploy ISO"]; Conductor -> Conductor [label = "Generates swift tempURL for deploy ISO"]; Conductor -> Conductor [label = "Creates the FAT32 image containing ironic API URL and driver name"]; Conductor -> Swift [label = "Uploads the FAT32 image"]; Conductor -> Conductor [label = "Generates swift tempURL for FAT32 image"]; Conductor -> iLO [label = "Attaches the FAT32 image swift tempURL as virtual media floppy"]; Conductor -> iLO [label = "Attaches the deploy ISO swift tempURL as virtual media CDROM"]; Conductor -> iLO [label = "Sets one time boot to CDROM"]; Conductor -> iLO [label = "Reboot the node"]; iLO -> Swift [label = "Downloads deploy ISO"]; Baremetal -> iLO [label = "Boots deploy kernel/ramdisk from iLO virtual media CDROM"]; IPA -> Conductor [label = "Lookup node"]; Conductor -> IPA [label = "Provides node UUID"]; IPA -> Conductor [label = "Heartbeat"]; Conductor -> IPA [label = "Sends the user image HTTP(S) URL"]; IPA -> Swift [label = "Retrieves the user image on bare metal"]; IPA -> IPA [label = "Writes user image to disk"]; IPA -> Conductor [label = "Heartbeat"]; Conductor -> Baremetal [label = "Sets boot device to disk"]; Conductor -> IPA [label = "Power off the node"]; Conductor -> iLO [label = "Power on the node"]; Baremetal -> Baremetal [label = "Boot user image from disk"]; } Netboot in swiftless deploy for intermediate images ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ .. seqdiag:: :scale: 80 diagram { Glance; Conductor; Baremetal; ConductorWebserver; IPA; iLO; activation = none; span_height = 1; edge_length = 250; default_note_color = white; default_fontsize = 14; Conductor -> iLO [label = "Powers off the node"]; Conductor -> Glance [label = "Download user image"]; Conductor -> Glance [label = "Get the metadata for deploy ISO"]; Conductor -> Conductor [label = "Generates swift tempURL for deploy ISO"]; Conductor -> Conductor [label = "Creates the FAT32 image containing Ironic API URL and driver name"]; Conductor -> ConductorWebserver [label = "Uploads the FAT32 image"]; Conductor -> iLO [label = "Attaches the FAT32 image URL as virtual media floppy"]; Conductor -> iLO [label = "Attaches the deploy ISO swift tempURL as virtual media CDROM"]; Conductor -> iLO [label = "Sets one time boot to CDROM"]; Conductor -> iLO [label = "Reboot the node"]; iLO -> Swift [label = "Downloads deploy ISO"]; Baremetal -> iLO [label = "Boots deploy kernel/ramdisk from iLO virtual media CDROM"]; IPA -> Conductor [label = "Lookup node"]; Conductor -> IPA [label = "Provides node UUID"]; IPA -> Conductor [label = "Heartbeat"]; Conductor -> IPA [label = "Exposes the disk over iSCSI"]; Conductor -> Conductor [label = "Connects to bare metal's disk over iSCSI and writes image"]; Conductor -> Conductor [label = "Generates the boot ISO"]; Conductor -> ConductorWebserver [label = "Uploads the boot ISO"]; Conductor -> iLO [label = "Attaches boot ISO URL as virtual media CDROM"]; Conductor -> iLO [label = "Sets boot device to CDROM"]; Conductor -> IPA [label = "Power off the node"]; Conductor -> iLO [label = "Power on the node"]; iLO -> ConductorWebserver [label = "Downloads boot ISO"]; iLO -> Baremetal [label = "Boots the instance kernel/ramdisk from iLO virtual media CDROM"]; Baremetal -> Baremetal [label = "Instance kernel finds root partition and continues booting from disk"]; } Localboot in swiftless deploy for intermediate images ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ .. seqdiag:: :scale: 80 diagram { Glance; Conductor; Baremetal; ConductorWebserver; IPA; iLO; activation = none; span_height = 1; edge_length = 250; default_note_color = white; default_fontsize = 14; Conductor -> iLO [label = "Powers off the node"]; Conductor -> Glance [label = "Get the metadata for deploy ISO"]; Glance -> Conductor [label = "Returns the metadata for deploy ISO"]; Conductor -> Conductor [label = "Generates swift tempURL for deploy ISO"]; Conductor -> Conductor [label = "Creates the FAT32 image containing Ironic API URL and driver name"]; Conductor -> ConductorWebserver [label = "Uploads the FAT32 image"]; Conductor -> iLO [label = "Attaches the FAT32 image URL as virtual media floppy"]; Conductor -> iLO [label = "Attaches the deploy ISO swift tempURL as virtual media CDROM"]; Conductor -> iLO [label = "Sets one time boot to CDROM"]; Conductor -> iLO [label = "Reboot the node"]; iLO -> Swift [label = "Downloads deploy ISO"]; Baremetal -> iLO [label = "Boots deploy kernel/ramdisk from iLO virtual media CDROM"]; IPA -> Conductor [label = "Lookup node"]; Conductor -> IPA [label = "Provides node UUID"]; IPA -> Conductor [label = "Heartbeat"]; Conductor -> IPA [label = "Sends the user image HTTP(S) URL"]; IPA -> Swift [label = "Retrieves the user image on bare metal"]; IPA -> IPA [label = "Writes user image to disk"]; IPA -> Conductor [label = "Heartbeat"]; Conductor -> Baremetal [label = "Sets boot device to disk"]; Conductor -> IPA [label = "Power off the node"]; Conductor -> Baremetal [label = "Power on the node"]; Baremetal -> Baremetal [label = "Boot user image from disk"]; } Netboot with HTTP(S) based deploy ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ .. seqdiag:: :scale: 80 diagram { Webserver; Conductor; Baremetal; Swift; IPA; iLO; activation = none; span_height = 1; edge_length = 250; default_note_color = white; default_fontsize = 14; Conductor -> iLO [label = "Powers off the node"]; Conductor -> Webserver [label = "Download user image"]; Conductor -> Conductor [label = "Creates the FAT32 image containing Ironic API URL and driver name"]; Conductor -> Swift [label = "Uploads the FAT32 image"]; Conductor -> Conductor [label = "Generates swift tempURL for FAT32 image"]; Conductor -> iLO [label = "Attaches the FAT32 image swift tempURL as virtual media floppy"]; Conductor -> iLO [label = "Attaches the deploy ISO URL as virtual media CDROM"]; Conductor -> iLO [label = "Sets one time boot to CDROM"]; Conductor -> iLO [label = "Reboot the node"]; iLO -> Webserver [label = "Downloads deploy ISO"]; Baremetal -> iLO [label = "Boots deploy kernel/ramdisk from iLO virtual media CDROM"]; IPA -> Conductor [label = "Lookup node"]; Conductor -> IPA [label = "Provides node UUID"]; IPA -> Conductor [label = "Heartbeat"]; Conductor -> IPA [label = "Exposes the disk over iSCSI"]; Conductor -> Conductor [label = "Connects to bare metal's disk over iSCSI and writes image"]; Conductor -> Conductor [label = "Generates the boot ISO"]; Conductor -> Swift [label = "Uploads the boot ISO"]; Conductor -> Conductor [label = "Generates swift tempURL for boot ISO"]; Conductor -> iLO [label = "Attaches boot ISO swift tempURL as virtual media CDROM"]; Conductor -> iLO [label = "Sets boot device to CDROM"]; Conductor -> IPA [label = "Power off the node"]; Conductor -> iLO [label = "Power on the node"]; iLO -> Swift [label = "Downloads boot ISO"]; iLO -> Baremetal [label = "Boots the instance kernel/ramdisk from iLO virtual media CDROM"]; Baremetal -> Baremetal [label = "Instance kernel finds root partition and continues booting from disk"]; } Localboot with HTTP(S) based deploy ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ .. seqdiag:: :scale: 80 diagram { Webserver; Conductor; Baremetal; Swift; IPA; iLO; activation = none; span_height = 1; edge_length = 250; default_note_color = white; default_fontsize = 14; Conductor -> iLO [label = "Powers off the node"]; Conductor -> Conductor [label = "Creates the FAT32 image containing ironic API URL and driver name"]; Conductor -> Swift [label = "Uploads the FAT32 image"]; Conductor -> Conductor [label = "Generates swift tempURL for FAT32 image"]; Conductor -> iLO [label = "Attaches the FAT32 image swift tempURL as virtual media floppy"]; Conductor -> iLO [label = "Attaches the deploy ISO URL as virtual media CDROM"]; Conductor -> iLO [label = "Sets one time boot to CDROM"]; Conductor -> iLO [label = "Reboot the node"]; iLO -> Webserver [label = "Downloads deploy ISO"]; Baremetal -> iLO [label = "Boots deploy kernel/ramdisk from iLO virtual media CDROM"]; IPA -> Conductor [label = "Lookup node"]; Conductor -> IPA [label = "Provides node UUID"]; IPA -> Conductor [label = "Heartbeat"]; Conductor -> IPA [label = "Sends the user image HTTP(S) URL"]; IPA -> Webserver [label = "Retrieves the user image on bare metal"]; IPA -> IPA [label = "Writes user image to disk"]; IPA -> Conductor [label = "Heartbeat"]; Conductor -> Baremetal [label = "Sets boot device to disk"]; Conductor -> IPA [label = "Power off the node"]; Conductor -> Baremetal [label = "Power on the node"]; Baremetal -> Baremetal [label = "Boot user image from disk"]; } Netboot in standalone ironic ^^^^^^^^^^^^^^^^^^^^^^^^^^^^ .. seqdiag:: :scale: 80 diagram { Webserver; Conductor; Baremetal; ConductorWebserver; IPA; iLO; activation = none; span_height = 1; edge_length = 250; default_note_color = white; default_fontsize = 14; Conductor -> iLO [label = "Powers off the node"]; Conductor -> Webserver [label = "Download user image"]; Conductor -> Conductor [label = "Creates the FAT32 image containing Ironic API URL and driver name"]; Conductor -> ConductorWebserver[label = "Uploads the FAT32 image"]; Conductor -> iLO [label = "Attaches the FAT32 image URL as virtual media floppy"]; Conductor -> iLO [label = "Attaches the deploy ISO URL as virtual media CDROM"]; Conductor -> iLO [label = "Sets one time boot to CDROM"]; Conductor -> iLO [label = "Reboot the node"]; iLO -> Webserver [label = "Downloads deploy ISO"]; Baremetal -> iLO [label = "Boots deploy kernel/ramdisk from iLO virtual media CDROM"]; IPA -> Conductor [label = "Lookup node"]; Conductor -> IPA [label = "Provides node UUID"]; IPA -> Conductor [label = "Heartbeat"]; Conductor -> IPA [label = "Exposes the disk over iSCSI"]; Conductor -> Conductor [label = "Connects to bare metal's disk over iSCSI and writes image"]; Conductor -> Conductor [label = "Generates the boot ISO"]; Conductor -> ConductorWebserver [label = "Uploads the boot ISO"]; Conductor -> iLO [label = "Attaches boot ISO URL as virtual media CDROM"]; Conductor -> iLO [label = "Sets boot device to CDROM"]; Conductor -> IPA [label = "Power off the node"]; Conductor -> iLO [label = "Power on the node"]; iLO -> ConductorWebserver [label = "Downloads boot ISO"]; iLO -> Baremetal [label = "Boots the instance kernel/ramdisk from iLO virtual media CDROM"]; Baremetal -> Baremetal [label = "Instance kernel finds root partition and continues booting from disk"]; } Localboot in standalone ironic ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ .. seqdiag:: :scale: 80 diagram { Webserver; Conductor; Baremetal; ConductorWebserver; IPA; iLO; activation = none; span_height = 1; edge_length = 250; default_note_color = white; default_fontsize = 14; Conductor -> iLO [label = "Powers off the node"]; Conductor -> Conductor [label = "Creates the FAT32 image containing Ironic API URL and driver name"]; Conductor -> ConductorWebserver [label = "Uploads the FAT32 image"]; Conductor -> Conductor [label = "Generates URL for FAT32 image"]; Conductor -> iLO [label = "Attaches the FAT32 image URL as virtual media floppy"]; Conductor -> iLO [label = "Attaches the deploy ISO URL as virtual media CDROM"]; Conductor -> iLO [label = "Sets one time boot to CDROM"]; Conductor -> iLO [label = "Reboot the node"]; iLO -> Webserver [label = "Downloads deploy ISO"]; Baremetal -> iLO [label = "Boots deploy kernel/ramdisk from iLO virtual media CDROM"]; IPA -> Conductor [label = "Lookup node"]; Conductor -> IPA [label = "Provides node UUID"]; IPA -> Conductor [label = "Heartbeat"]; Conductor -> IPA [label = "Sends the user image HTTP(S) URL"]; IPA -> Webserver [label = "Retrieves the user image on bare metal"]; IPA -> IPA [label = "Writes user image to disk"]; IPA -> Conductor [label = "Heartbeat"]; Conductor -> Baremetal [label = "Sets boot device to disk"]; Conductor -> IPA [label = "Power off the node"]; Conductor -> Baremetal [label = "Power on the node"]; Baremetal -> Baremetal [label = "Boot user image from disk"]; } Activating iLO Advanced license as manual clean step ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ iLO drivers can activate the iLO Advanced license key as a manual cleaning step. Any manual cleaning step can only be initiated when a node is in the ``manageable`` state. Once the manual cleaning is finished, the node will be put in the ``manageable`` state again. User can follow steps from :ref:`manual_cleaning` to initiate manual cleaning operation on a node. An example of a manual clean step with ``activate_license`` as the only clean step could be:: "clean_steps": [{ "interface": "management", "step": "activate_license", "args": { "ilo_license_key": "ABC12-XXXXX-XXXXX-XXXXX-YZ345" } }] The different attributes of ``activate_license`` clean step are as follows: .. csv-table:: :header: "Attribute", "Description" :widths: 30, 120 "``interface``", "Interface of clean step, here ``management``" "``step``", "Name of clean step, here ``activate_license``" "``args``", "Keyword-argument entry (: ) being passed to clean step" "``args.ilo_license_key``", "iLO Advanced license key to activate enterprise features. This is mandatory." Initiating firmware update as manual clean step ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ iLO drivers can invoke secure firmware update as a manual cleaning step. Any manual cleaning step can only be initiated when a node is in the ``manageable`` state. Once the manual cleaning is finished, the node will be put in the ``manageable`` state again. A user can follow steps from :ref:`manual_cleaning` to initiate manual cleaning operation on a node. An example of a manual clean step with ``update_firmware`` as the only clean step could be:: "clean_steps": [{ "interface": "management", "step": "update_firmware", "args": { "firmware_update_mode": "ilo", "firmware_images":[ { "url": "file:///firmware_images/ilo/1.5/CP024444.scexe", "checksum": "a94e683ea16d9ae44768f0a65942234d", "component": "ilo" }, { "url": "swift://firmware_container/cpld2.3.rpm", "checksum": "", "component": "cpld" }, { "url": "http://my_address:port/firmwares/bios_vLatest.scexe", "checksum": "", "component": "bios" }, { "url": "https://my_secure_address_url/firmwares/chassis_vLatest.scexe", "checksum": "", "component": "chassis" }, { "url": "file:///home/ubuntu/firmware_images/power_pic/pmc_v3.0.bin", "checksum": "", "component": "power_pic" } ] } }] The different attributes of ``update_firmware`` clean step are as follows: .. csv-table:: :header: "Attribute", "Description" :widths: 30, 120 "``interface``", "Interface of clean step, here ``management``" "``step``", "Name of clean step, here ``update_firmware``" "``args``", "Keyword-argument entry (: ) being passed to clean step" "``args.firmware_update_mode``", "Mode (or mechanism) of out-of-band firmware update. Supported value is ``ilo``. This is mandatory." "``args.firmware_images``", "Ordered list of dictionaries of images to be flashed. This is mandatory." Each firmware image block is represented by a dictionary (JSON), in the form:: { "url": "", "checksum": "", "component": "" } All the fields in the firmware image block are mandatory. * The different types of firmware url schemes supported are: ``file``, ``http``, ``https`` and ``swift``. .. note:: This feature assumes that while using ``file`` url scheme the file path is on the conductor controlling the node. .. note:: The ``swift`` url scheme assumes the swift account of the ``service`` project. The ``service`` project (tenant) is a special project created in the Keystone system designed for the use of the core OpenStack services. When Ironic makes use of Swift for storage purpose, the account is generally ``service`` and the container is generally ``ironic`` and ``ilo`` drivers use a container named ``ironic_ilo_container`` for their own purpose. .. note:: While using firmware files with a ``.rpm`` extension, make sure the commands ``rpm2cpio`` and ``cpio`` are present on the conductor, as they are utilized to extract the firmware image from the package. * The firmware components that can be updated are: ``ilo``, ``cpld``, ``power_pic``, ``bios`` and ``chassis``. * The firmware images will be updated in the order given by the operator. If there is any error during processing of any of the given firmware images provided in the list, none of the firmware updates will occur. The processing error could happen during image download, image checksum verification or image extraction. The logic is to process each of the firmware files and update them on the devices only if all the files are processed successfully. If, during the update (uploading and flashing) process, an update fails, then the remaining updates, if any, in the list will be aborted. But it is recommended to triage and fix the failure and re-attempt the manual clean step ``update_firmware`` for the aborted ``firmware_images``. The devices for which the firmwares have been updated successfully would start functioning using their newly updated firmware. * As a troubleshooting guidance on the complete process, check Ironic conductor logs carefully to see if there are any firmware processing or update related errors which may help in root causing or gain an understanding of where things were left off or where things failed. You can then fix or work around and then try again. A common cause of update failure is HPE Secure Digital Signature check failure for the firmware image file. * To compute ``md5`` checksum for your image file, you can use the following command:: $ md5sum image.rpm 66cdb090c80b71daa21a67f06ecd3f33 image.rpm RAID Support ^^^^^^^^^^^^ The inband RAID functionality is supported by iLO drivers. See :ref:`raid` for more information. Bare Metal service update node with following information after successful configuration of RAID: * Node ``properties/local_gb`` is set to the size of root volume. * Node ``properties/root_device`` is filled with ``wwn`` details of root volume. It is used by iLO drivers as root device hint during provisioning. * The value of raid level of root volume is added as ``raid_level`` capability to the node's ``capabilities`` parameter within ``properties`` field. The operator can specify the ``raid_level`` capability in nova flavor for node to be selected for scheduling:: nova flavor-key ironic-test set capabilities:raid_level="1+0" nova boot --flavor ironic-test --image test-image instance-1 .. _DIB_raid_support: DIB support for Proliant Hardware Manager ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ To create an agent ramdisk with ``Proliant Hardware Manager``, use the ``proliant-tools`` element in DIB:: disk-image-create -o proliant-agent-ramdisk ironic-agent fedora proliant-tools Disk Erase Support ^^^^^^^^^^^^^^^^^^ ``erase_devices`` is an inband clean step supported by iLO drives. It performs erase on all the disks including the disks visible to OS as well as the raw disks visible to the Smart Storage Administrator (SSA). This inband clean step requires ``ssacli`` utility starting from version ``2.60-19.0`` to perform the erase on physical disks. See the `ssacli documentation`_ for more information on ssacli utility and different erase methods supported by SSA. The disk erasure via ``shred`` is used to erase disks visible to the OS and its implementation is available in Ironic Python Agent. The raw disks connected to the Smart Storage Controller are erased using Sanitize erase which is a ssacli supported erase method. If Sanitize erase is not supported on the Smart Storage Controller the disks are erased using One-pass erase (overwrite with zeros). This clean step is supported when the agent ramdisk contains the ``Proliant Hardware Manager`` from the proliantutils version 2.3.0 or higher. This clean step is performed as part of automated cleaning and it is disabled by default. See :ref:`InbandvsOutOfBandCleaning` for more information on enabling/disabling a clean step. To create an agent ramdisk with ``Proliant Hardware Manager``, use the ``proliant-tools`` element in DIB:: disk-image-create -o proliant-agent-ramdisk ironic-agent fedora proliant-tools See the `proliant-tools`_ for more information on creating agent ramdisk with ``proliant-tools`` element in DIB. .. _`ssacli documentation`: http://h20566.www2.hpe.com/hpsc/doc/public/display?docId=c03909334 .. _`proliant-tools`: https://docs.openstack.org/diskimage-builder/latest/elements/proliant-tools/README.html .. _`HPE iLO4 User Guide`: http://h20566.www2.hpe.com/hpsc/doc/public/display?docId=c03334051 .. _`iLO 4 management engine`: https://www.hpe.com/us/en/servers/integrated-lights-out-ilo.html .. _`iLO 5 management engine`: https://www.hpe.com/us/en/servers/integrated-lights-out-ilo.html#innovations .. _`Redfish`: https://www.dmtf.org/standards/redfish .. _`Gen10 wiki section`: https://wiki.openstack.org/wiki/Ironic/Drivers/iLODrivers/master#Enabling_ProLiant_Gen10_systems_in_Ironic