fixes: |
|
- | |
|
Fixes issues when ``UEFI`` boot mode has been requested with persistent |
|
boot to ``DISK`` where some versions of ``ipmitool`` do not properly |
|
handle multiple options being set at the same time. While some of this |
|
logic was addressed in upstream `ipmitool <https://github.com/ipmitool/ipmitool/issues/163>`_ |
|
development, new versions are not released and vendors maintain downstream |
|
forks of the ipmitool utility. When considering vendor specific `selector |
|
differences <https://storyboard.openstack.org/#!/story/2008241>`_ along |
|
with the current stance of new versions from the upstream ``ipmitool`` |
|
community, it only made sense to handle this logic with-in Ironic. |
|
In part this was because if already set the selector value would not be |
|
updated. Now ironic always transmits the selector value for ``UEFI``. |
|
- Fixes handling of Supermicro ``UEFI`` supporting BMCs with the ``ipmi`` |
|
hardware type such that an appropriate boot device selector value is sent |
|
to the remote BMC to indicate boot from local storage. This is available |
|
for both persistent and one-time boot applications. For more information, |
|
please consult `story 2008241 <https://storyboard.openstack.org/#!/story/2008241>`_. |
|
- Fixes handling of the ``ipmi`` hardware type where ``UEFI`` boot mode and |
|
"one-time" boot to PXE has been requested. As Ironic now specifically |
|
transmits the raw commands, this setting should be properly appied where |
|
previously PXE boot operations may have previously occured in |
|
``Legacy BIOS`` mode. |
|
other: |
|
- Adds a ``detect_vendor`` management interface method to the ``ipmi`` |
|
hardware type. This method is being promoted as a higher level interface |
|
as the fundimental need to be able to have logic aware of the hardware |
|
vendor is necessary with vendor agnostic drivers where slight differences |
|
require slightly different behavior. |
|
upgrade: |
|
- An automated detection of a IPMI BMC hardware vendor has been added to |
|
appropriately handle IPMI BMC variations. Ironic will now query this and |
|
save this value if not already set in order to avoid querying for |
|
every single operation. Operators upgrading should expect an elongated |
|
first power state synchronization if for nodes with the ``ipmi`` |
|
hardware type.
|
|
|