ironic/ironic/conf/conductor.py
Pavlo Shchelokovskyy 308e414a57 Introduce keystoneauth adapters for clients
Currently ironic explicitly or implicitly sets the API urls
for most services in the config.
This is quite fragile and we should move to discovery from
the keystone catalog eventually.

To support this, this patch registers `keystoneauth1.adapter.Adapter`
options to all config sections for service clients auth.
Among others it exports `interfaces` option that we set to
['internal', 'public'] by default.
Other exported options are `service_type`, `service_name`, `region_name`
and `endpoint_override`.
The latter will eventually be used by all clients to specify a specific
endpoint to use (for example in noauth mode).

Effectively this patch starts to move all clients code to load client
configuration from config for all of auth, session and adapter.

The first to move is [service_catalog] section, with [conductor]api_url
option being deprecated in favor of [service_catalog]endpoint_override.
A sane default of 'service_type' = 'baremetal' is set for this config
section as well.

More patches moving other clients to consume these new options and
deprecate some other options will follow.

Change-Id: I1283ef3b4d736ac089df0cc74a5850a93b24b6ab
Partial-Bug: #1699547
Related-Bug: #1699542
2017-08-22 06:07:19 +00:00

164 lines
8.4 KiB
Python

# Copyright 2016 Intel Corporation
# Copyright 2013 Hewlett-Packard Development Company, L.P.
# Copyright 2013 International Business Machines Corporation
# All Rights Reserved.
#
# Licensed under the Apache License, Version 2.0 (the "License"); you may
# not use this file except in compliance with the License. You may obtain
# a copy of the License at
#
# http://www.apache.org/licenses/LICENSE-2.0
#
# Unless required by applicable law or agreed to in writing, software
# distributed under the License is distributed on an "AS IS" BASIS, WITHOUT
# WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. See the
# License for the specific language governing permissions and limitations
# under the License.
from oslo_config import cfg
from ironic.common.i18n import _
opts = [
cfg.IntOpt('workers_pool_size',
default=100, min=3,
help=_('The size of the workers greenthread pool. '
'Note that 2 threads will be reserved by the conductor '
'itself for handling heart beats and periodic tasks.')),
cfg.IntOpt('heartbeat_interval',
default=10,
help=_('Seconds between conductor heart beats.')),
cfg.URIOpt('api_url',
schemes=('http', 'https'),
deprecated_for_removal=True,
deprecated_reason=_("Use [service_catalog]endpoint_override "
"option instead if required to use "
"a specific ironic api address, "
"for example in noauth mode."),
help=_('URL of Ironic API service. If not set ironic can '
'get the current value from the keystone service '
'catalog. If set, the value must start with either '
'http:// or https://.')),
cfg.IntOpt('heartbeat_timeout',
default=60,
help=_('Maximum time (in seconds) since the last check-in '
'of a conductor. A conductor is considered inactive '
'when this time has been exceeded.')),
cfg.IntOpt('sync_power_state_interval',
default=60,
help=_('Interval between syncing the node power state to the '
'database, in seconds.')),
cfg.IntOpt('check_provision_state_interval',
default=60,
help=_('Interval between checks of provision timeouts, '
'in seconds.')),
cfg.IntOpt('deploy_callback_timeout',
default=1800,
help=_('Timeout (seconds) to wait for a callback from '
'a deploy ramdisk. Set to 0 to disable timeout.')),
cfg.BoolOpt('force_power_state_during_sync',
default=True,
help=_('During sync_power_state, should the hardware power '
'state be set to the state recorded in the database '
'(True) or should the database be updated based on '
'the hardware state (False).')),
cfg.IntOpt('power_state_sync_max_retries',
default=3,
help=_('During sync_power_state failures, limit the '
'number of times Ironic should try syncing the '
'hardware node power state with the node power state '
'in DB')),
cfg.IntOpt('periodic_max_workers',
default=8,
help=_('Maximum number of worker threads that can be started '
'simultaneously by a periodic task. Should be less '
'than RPC thread pool size.')),
cfg.IntOpt('node_locked_retry_attempts',
default=3,
help=_('Number of attempts to grab a node lock.')),
cfg.IntOpt('node_locked_retry_interval',
default=1,
help=_('Seconds to sleep between node lock attempts.')),
cfg.BoolOpt('send_sensor_data',
default=False,
help=_('Enable sending sensor data message via the '
'notification bus')),
cfg.IntOpt('send_sensor_data_interval',
default=600,
help=_('Seconds between conductor sending sensor data message '
'to ceilometer via the notification bus.')),
cfg.IntOpt('send_sensor_data_workers',
default=4, min=1,
help=_('The maximum number of workers that can be started '
'simultaneously for send data from sensors periodic '
'task.')),
cfg.IntOpt('send_sensor_data_wait_timeout',
default=300,
help=_('The time in seconds to wait for send sensors data '
'periodic task to be finished before allowing periodic '
'call to happen again. Should be less than '
'send_sensor_data_interval value.')),
cfg.ListOpt('send_sensor_data_types',
default=['ALL'],
help=_('List of comma separated meter types which need to be'
' sent to Ceilometer. The default value, "ALL", is a '
'special value meaning send all the sensor data.')),
cfg.IntOpt('sync_local_state_interval',
default=180,
help=_('When conductors join or leave the cluster, existing '
'conductors may need to update any persistent '
'local state as nodes are moved around the cluster. '
'This option controls how often, in seconds, each '
'conductor will check for nodes that it should '
'"take over". Set it to a negative value to disable '
'the check entirely.')),
cfg.StrOpt('configdrive_swift_container',
default='ironic_configdrive_container',
help=_('Name of the Swift container to store config drive '
'data. Used when configdrive_use_object_store is '
'True.')),
cfg.IntOpt('inspect_timeout',
default=1800,
help=_('Timeout (seconds) for waiting for node inspection. '
'0 - unlimited.')),
cfg.BoolOpt('automated_clean',
default=True,
help=_('Enables or disables automated cleaning. Automated '
'cleaning is a configurable set of steps, '
'such as erasing disk drives, that are performed on '
'the node to ensure it is in a baseline state and '
'ready to be deployed to. This is '
'done after instance deletion as well as during '
'the transition from a "manageable" to "available" '
'state. When enabled, the particular steps '
'performed to clean a node depend on which driver '
'that node is managed by; see the individual '
'driver\'s documentation for details. '
'NOTE: The introduction of the cleaning operation '
'causes instance deletion to take significantly '
'longer. In an environment where all tenants are '
'trusted (eg, because there is only one tenant), '
'this option could be safely disabled.')),
cfg.IntOpt('clean_callback_timeout',
default=1800,
help=_('Timeout (seconds) to wait for a callback from the '
'ramdisk doing the cleaning. If the timeout is reached '
'the node will be put in the "clean failed" provision '
'state. Set to 0 to disable timeout.')),
cfg.IntOpt('soft_power_off_timeout',
default=600,
min=1,
help=_('Timeout (in seconds) of soft reboot and soft power '
'off operation. This value always has to be positive.')),
cfg.IntOpt('power_state_change_timeout',
min=2, default=30,
help=_('Number of seconds to wait for power operations to '
'complete, i.e., so that a baremetal node is in the '
'desired power state. If timed out, the power operation '
'is considered a failure.')),
]
def register_opts(conf):