ironic/devstack/upgrade/upgrade.sh
Iury Gregory Melo Ferreira 1f0174bb41 Native zuulv3 grenade multinode multitenant
Based on the native 'grenade-multinode' job

Change-Id: I4d0a23c371bc42c5bf18e79ea7920bd77b066154
2020-09-16 23:33:42 +02:00

142 lines
4.8 KiB
Bash
Executable File

#!/usr/bin/env bash
# ``upgrade-ironic``
echo "*********************************************************************"
echo "Begin $0"
echo "*********************************************************************"
# Clean up any resources that may be in use
cleanup() {
set +o errexit
echo "*********************************************************************"
echo "ERROR: Abort $0"
echo "*********************************************************************"
# Kill ourselves to signal any calling process
trap 2; kill -2 $$
}
trap cleanup SIGHUP SIGINT SIGTERM
# Keep track of the grenade directory
RUN_DIR=$(cd $(dirname "$0") && pwd)
# Source params
source $GRENADE_DIR/grenaderc
# Import common functions
source $GRENADE_DIR/functions
# This script exits on an error so that errors don't compound and you see
# only the first error that occurred.
set -o errexit
# Upgrade Ironic
# ============
# Duplicate some setup bits from target DevStack
source $TARGET_DEVSTACK_DIR/stackrc
source $TARGET_DEVSTACK_DIR/lib/tls
source $TARGET_DEVSTACK_DIR/lib/nova
source $TARGET_DEVSTACK_DIR/lib/neutron-legacy
source $TARGET_DEVSTACK_DIR/lib/apache
source $TARGET_DEVSTACK_DIR/lib/keystone
source $TOP_DIR/openrc admin admin
# Keep track of the DevStack directory
IRONIC_DEVSTACK_DIR=$(dirname "$0")/..
source $IRONIC_DEVSTACK_DIR/lib/ironic
# Print the commands being run so that we can see the command that triggers
# an error. It is also useful for following allowing as the install occurs.
set -o xtrace
function wait_for_keystone {
if ! wait_for_service $SERVICE_TIMEOUT ${KEYSTONE_AUTH_URI}/v$IDENTITY_API_VERSION/; then
die $LINENO "keystone did not start"
fi
}
# Save current config files for posterity
if [[ -d $IRONIC_CONF_DIR ]] && [[ ! -d $SAVE_DIR/etc.ironic ]] ; then
cp -pr $IRONIC_CONF_DIR $SAVE_DIR/etc.ironic
fi
stack_install_service ironic
# calls upgrade-ironic for specific release
upgrade_project ironic $RUN_DIR $BASE_DEVSTACK_BRANCH $TARGET_DEVSTACK_BRANCH
# NOTE(rloo): make sure it is OK to do an upgrade. Except that we aren't
# parsing/checking the output of this command because the output could change
# based on the checks it makes.
$IRONIC_BIN_DIR/ironic-status upgrade check
$IRONIC_BIN_DIR/ironic-dbsync --config-file=$IRONIC_CONF_FILE
# NOTE(vsaienko) pin_release only on multinode job, for cold upgrade (single node)
# run online data migration instead.
if [[ "${HOST_TOPOLOGY}" == "multinode" ]]; then
iniset $IRONIC_CONF_FILE DEFAULT pin_release_version ${BASE_DEVSTACK_BRANCH#*/}
else
ironic-dbsync online_data_migrations
fi
ensure_started='ironic-conductor nova-compute '
ensure_stopped=''
# Multinode grenade is designed to upgrade services only on primary node. And there is no way to manipulate
# subnode during grenade phases. With this after upgrade we can have upgraded (new) services on primary
# node and not upgraded (old) services on subnode.
# According to Ironic upgrade procedure, we shouldn't have upgraded (new) ironic-api and not upgraded (old)
# ironic-conductor. By setting redirect of API requests from primary node to subnode during upgrade
# allow to satisfy ironic upgrade requirements.
if [[ "$HOST_TOPOLOGY_ROLE" == "primary" ]]; then
disable_service ir-api
ensure_stopped+='ironic-api'
ironic_wsgi_conf=$(apache_site_config_for ironic-api-wsgi)
sudo cp $IRONIC_DEVSTACK_FILES_DIR/apache-ironic-api-redirect.template $ironic_wsgi_conf
sudo sed -e "
s|%IRONIC_SERVICE_PROTOCOL%|$IRONIC_SERVICE_PROTOCOL|g;
s|%IRONIC_SERVICE_HOST%|$IRONIC_PROVISION_SUBNET_SUBNODE_IP|g;
" -i $ironic_wsgi_conf
enable_apache_site ipxe-ironic
restart_apache_server
else
ensure_started+='ironic-api '
fi
start_ironic
# NOTE(vsaienko) do not restart n-cpu on multinode as we didn't upgrade nova.
if [[ "${HOST_TOPOLOGY}" != "multinode" ]]; then
# NOTE(vsaienko) installing ironic service triggers apache restart, that
# may cause nova-compute failure due to LP1537076
stop_nova_compute || true
wait_for_keystone
start_nova_compute
fi
if [[ -n "$ensure_stopped" ]]; then
ensure_services_stopped $ensure_stopped
fi
ensure_services_started $ensure_started
# We need these steps only in case of flat-network
# NOTE(vsaienko) starting from Ocata when Neutron is restarted there is no guarantee that
# internal tag, that was assigned to network will be the same. As result we need to update
# tag on link between br-int and brbm to new value after restart.
if [[ -z "${IRONIC_PROVISION_NETWORK_NAME}" ]]; then
net_id=$(openstack network show ironic_grenade -f value -c id)
create_ovs_taps $net_id
fi
set +o xtrace
echo "*********************************************************************"
echo "SUCCESS: End $0"
echo "*********************************************************************"