ironic/ironic/conf/conductor.py

179 lines
9.2 KiB
Python

# Copyright 2016 Intel Corporation
# Copyright 2013 Hewlett-Packard Development Company, L.P.
# Copyright 2013 International Business Machines Corporation
# All Rights Reserved.
#
# Licensed under the Apache License, Version 2.0 (the "License"); you may
# not use this file except in compliance with the License. You may obtain
# a copy of the License at
#
# http://www.apache.org/licenses/LICENSE-2.0
#
# Unless required by applicable law or agreed to in writing, software
# distributed under the License is distributed on an "AS IS" BASIS, WITHOUT
# WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. See the
# License for the specific language governing permissions and limitations
# under the License.
from oslo_config import cfg
from ironic.common.i18n import _
opts = [
cfg.IntOpt('workers_pool_size',
default=100, min=3,
help=_('The size of the workers greenthread pool. '
'Note that 2 threads will be reserved by the conductor '
'itself for handling heart beats and periodic tasks.')),
cfg.IntOpt('heartbeat_interval',
default=10,
help=_('Seconds between conductor heart beats.')),
cfg.URIOpt('api_url',
schemes=('http', 'https'),
deprecated_for_removal=True,
deprecated_reason=_("Use [service_catalog]endpoint_override "
"option instead if required to use "
"a specific ironic api address, "
"for example in noauth mode."),
help=_('URL of Ironic API service. If not set ironic can '
'get the current value from the keystone service '
'catalog. If set, the value must start with either '
'http:// or https://.')),
cfg.IntOpt('heartbeat_timeout',
default=60,
help=_('Maximum time (in seconds) since the last check-in '
'of a conductor. A conductor is considered inactive '
'when this time has been exceeded.')),
cfg.IntOpt('sync_power_state_interval',
default=60,
help=_('Interval between syncing the node power state to the '
'database, in seconds.')),
cfg.IntOpt('check_provision_state_interval',
default=60,
help=_('Interval between checks of provision timeouts, '
'in seconds.')),
cfg.IntOpt('check_rescue_state_interval',
default=60,
min=1,
help=_('Interval (seconds) between checks of rescue '
'timeouts. This option is part of rescue feature '
'work, which is not currently exposed to users.')),
cfg.IntOpt('deploy_callback_timeout',
default=1800,
help=_('Timeout (seconds) to wait for a callback from '
'a deploy ramdisk. Set to 0 to disable timeout.')),
cfg.BoolOpt('force_power_state_during_sync',
default=True,
help=_('During sync_power_state, should the hardware power '
'state be set to the state recorded in the database '
'(True) or should the database be updated based on '
'the hardware state (False).')),
cfg.IntOpt('power_state_sync_max_retries',
default=3,
help=_('During sync_power_state failures, limit the '
'number of times Ironic should try syncing the '
'hardware node power state with the node power state '
'in DB')),
cfg.IntOpt('periodic_max_workers',
default=8,
help=_('Maximum number of worker threads that can be started '
'simultaneously by a periodic task. Should be less '
'than RPC thread pool size.')),
cfg.IntOpt('node_locked_retry_attempts',
default=3,
help=_('Number of attempts to grab a node lock.')),
cfg.IntOpt('node_locked_retry_interval',
default=1,
help=_('Seconds to sleep between node lock attempts.')),
cfg.BoolOpt('send_sensor_data',
default=False,
help=_('Enable sending sensor data message via the '
'notification bus')),
cfg.IntOpt('send_sensor_data_interval',
default=600,
help=_('Seconds between conductor sending sensor data message '
'to ceilometer via the notification bus.')),
cfg.IntOpt('send_sensor_data_workers',
default=4, min=1,
help=_('The maximum number of workers that can be started '
'simultaneously for send data from sensors periodic '
'task.')),
cfg.IntOpt('send_sensor_data_wait_timeout',
default=300,
help=_('The time in seconds to wait for send sensors data '
'periodic task to be finished before allowing periodic '
'call to happen again. Should be less than '
'send_sensor_data_interval value.')),
cfg.ListOpt('send_sensor_data_types',
default=['ALL'],
help=_('List of comma separated meter types which need to be'
' sent to Ceilometer. The default value, "ALL", is a '
'special value meaning send all the sensor data.')),
cfg.IntOpt('sync_local_state_interval',
default=180,
help=_('When conductors join or leave the cluster, existing '
'conductors may need to update any persistent '
'local state as nodes are moved around the cluster. '
'This option controls how often, in seconds, each '
'conductor will check for nodes that it should '
'"take over". Set it to a negative value to disable '
'the check entirely.')),
cfg.StrOpt('configdrive_swift_container',
default='ironic_configdrive_container',
help=_('Name of the Swift container to store config drive '
'data. Used when configdrive_use_object_store is '
'True.')),
cfg.IntOpt('inspect_timeout',
default=1800,
help=_('Timeout (seconds) for waiting for node inspection. '
'0 - unlimited.')),
cfg.BoolOpt('automated_clean',
default=True,
help=_('Enables or disables automated cleaning. Automated '
'cleaning is a configurable set of steps, '
'such as erasing disk drives, that are performed on '
'the node to ensure it is in a baseline state and '
'ready to be deployed to. This is '
'done after instance deletion as well as during '
'the transition from a "manageable" to "available" '
'state. When enabled, the particular steps '
'performed to clean a node depend on which driver '
'that node is managed by; see the individual '
'driver\'s documentation for details. '
'NOTE: The introduction of the cleaning operation '
'causes instance deletion to take significantly '
'longer. In an environment where all tenants are '
'trusted (eg, because there is only one tenant), '
'this option could be safely disabled.')),
cfg.IntOpt('clean_callback_timeout',
default=1800,
help=_('Timeout (seconds) to wait for a callback from the '
'ramdisk doing the cleaning. If the timeout is reached '
'the node will be put in the "clean failed" provision '
'state. Set to 0 to disable timeout.')),
cfg.IntOpt('rescue_callback_timeout',
default=1800,
min=0,
help=_('Timeout (seconds) to wait for a callback from the '
'rescue ramdisk. If the timeout is reached the node '
'will be put in the "rescue failed" provision state. '
'Set to 0 to disable timeout. This option is part of '
'rescue feature work, which is not currently exposed '
'to users.')),
cfg.IntOpt('soft_power_off_timeout',
default=600,
min=1,
help=_('Timeout (in seconds) of soft reboot and soft power '
'off operation. This value always has to be positive.')),
cfg.IntOpt('power_state_change_timeout',
min=2, default=30,
help=_('Number of seconds to wait for power operations to '
'complete, i.e., so that a baremetal node is in the '
'desired power state. If timed out, the power operation '
'is considered a failure.')),
]
def register_opts(conf):