d379357cad
Some type of BMCs don't support an IPMI option that disable the behavior of boot device timeout, which makes them never get booted from PXE. This patch extends the fix [1] by adding a configuration option, which provides the default ipmi behavior. [1] https://review.openstack.org/#/c/616053 Additionally revising the variable/setting names based upon review feedback and discussion that took place during the 20181210 weekly ironic team meeting. Change-Id: Ie049bbaf45aeab54c1272d1d561c5a6ca00dc34a Story: 2002977 Task: 22985
12 lines
522 B
YAML
12 lines
522 B
YAML
---
|
|
features:
|
|
- |
|
|
Adds a configuration option ``[ipmi]disable_boot_timeout`` which is used
|
|
to set the default behavior whether ironic should send a raw IPMI command
|
|
to disable timeout. This configuration option can be overidden by the
|
|
per-node option ``ipmi_disable_boot_timeout`` in node's ``driver_info``
|
|
field.
|
|
See `story 2004266 <https://storyboard.openstack.org/#!/story/2004266>`_
|
|
and `Story 2002977 <https://storyboard.openstack.org/#!/story/2002977>`_
|
|
for additional information.
|