This change creates all necessary parts to processing inspection data:
* New API /v1/continue_inspection
Depending on the API version, either behaves like the inspector's API
or (new version) adds the lookup functionality on top.
The lookup process is migrated from ironic-inspector with minor changes.
It takes MAC addresses, BMC addresses and (optionally) a node UUID and
tries to find a single node in INSPECTWAIT state that satisfies all
of these. Any failure results in HTTP 404.
To make lookup faster, the resolved BMC addresses are cached in advance.
* New RPC continue_inspection
Essentially, checks the provision state again and delegates to the
inspect interface.
* New inspect interface call continue_inspection
The base version does nothing. Since we don't yet have in-band
inspection in Ironic proper, the only actual implementation is added
to the existing "inspector" interface that works by doing a call
to ironic-inspector.
Story: #2010275
Task: #46208