fixes:
- |
When using the PERC H730P RAID controller, physical
disks must be put into RAID mode prior to creating a
virtual disk that includes them. If one or more
physical disks are in JBOD/Non-RAID mode when creating
a virtual disk from them, then the iDRAC will return
an error. This patch ensures that the physical disks
being included in a virtual disk are converted to RAID
mode prior to creating the virtual disk.