Fix OVN gates

A new Devstack setting was recently introduced[1] for OVN
OVN_BUILD_FROM_SOURCE allowing to use the packaged
version when set to False. The value of OVS_RUNDIR
changes accordingly that setting, so we needs to make sure
ovs will always run on same path to avoid database
connection failures.

[1] https://github.com/openstack/devstack/
    commit/e651d9ef8840bb7dd497b557125ce1cd5290993d

Change-Id: I3a7b7dcd46cb5efa747d72517b5c26560db698af
This commit is contained in:
Maysa Macedo 2021-01-04 18:59:00 +00:00
parent 500ff16481
commit c68a6fe1e7
2 changed files with 4 additions and 4 deletions

View File

@ -31,8 +31,8 @@
Q_ML2_PLUGIN_MECHANISM_DRIVERS: ovn,logger
Q_ML2_PLUGIN_TYPE_DRIVERS: local,flat,vlan,geneve
Q_ML2_TENANT_NETWORK_TYPE: geneve
VAR_RUN_PATH: /usr/local/var/run
Q_USE_PROVIDERNET_FOR_PUBLIC: true
VAR_RUN_PATH: /var/run
PHYSICAL_NETWORK: public
OVN_L3_CREATE_PUBLIC_NETWORK: true
ENABLE_CHASSIS_AS_GW: true
@ -138,8 +138,8 @@
Q_ML2_PLUGIN_MECHANISM_DRIVERS: ovn,logger
Q_ML2_PLUGIN_TYPE_DRIVERS: local,flat,vlan,geneve
Q_ML2_TENANT_NETWORK_TYPE: geneve
VAR_RUN_PATH: /usr/local/var/run
Q_USE_PROVIDERNET_FOR_PUBLIC: true
VAR_RUN_PATH: /var/run
PHYSICAL_NETWORK: public
OVN_L3_CREATE_PUBLIC_NETWORK: true
ENABLE_CHASSIS_AS_GW: true

View File

@ -43,8 +43,8 @@ enable_service q-svc
# VAR RUN PATH
# =============
# VAR_RUN_PATH=/var/run
VAR_RUN_PATH=/usr/local/var/run
# VAR_RUN_PATH=/usr/local/var/run
VAR_RUN_PATH=/var/run
# OCTAVIA
# Uncomment it to use L2 communication between loadbalancer and member pods