Remove ovn-octavia provider tcp+udp limitation
ovn-octavia provider now can handle listeners on the same port for both udp and tcp Change-Id: I9d5e9bb9219c2d1eaca8ed43633bd41f428b2a4e
This commit is contained in:
parent
3795b84f59
commit
dc78e0cef3
|
@ -44,7 +44,9 @@ _ACTIVATION_TIMEOUT = CONF.neutron_defaults.lbaas_activation_timeout
|
|||
_LB_STS_POLL_FAST_INTERVAL = 1
|
||||
_LB_STS_POLL_SLOW_INTERVAL = 3
|
||||
_OCTAVIA_TAGGING_VERSION = 2, 5
|
||||
_OCTAVIA_DL_VERSION = 2, 11
|
||||
# NOTE(ltomasbo): amphora supports it on 2.11, but ovn-octavia only on 2.13
|
||||
# In order to make it simpler, we assume this is supported only from 2.13
|
||||
_OCTAVIA_DL_VERSION = 2, 13
|
||||
_OCTAVIA_ACL_VERSION = 2, 12
|
||||
|
||||
|
||||
|
@ -67,13 +69,9 @@ class LBaaSv2Driver(base.LBaaSDriver):
|
|||
self._octavia_acls = True
|
||||
LOG.info('Octavia supports ACLs for Amphora provider.')
|
||||
if v >= _OCTAVIA_DL_VERSION:
|
||||
# FIXME(ltomasbo): ovn-octavia driver does not yet support double
|
||||
# listeners. Remove when it does, considering the right
|
||||
# octavia microversion
|
||||
if CONF.kubernetes.endpoints_driver_octavia_provider != 'ovn':
|
||||
self._octavia_double_listeners = True
|
||||
LOG.info('Octavia supports double listeners (different '
|
||||
'protocol, same port) for Amphora provider.')
|
||||
self._octavia_double_listeners = True
|
||||
LOG.info('Octavia supports double listeners (different '
|
||||
'protocol, same port) for Amphora provider.')
|
||||
if v >= _OCTAVIA_TAGGING_VERSION:
|
||||
LOG.info('Octavia supports resource tags.')
|
||||
self._octavia_tags = True
|
||||
|
|