Manila VMAX docs - improve pre-configurations on VMAX section
Add storage pool and license configuration to the Pre-configurations on VMAX section. Change-Id: I9f598c6918455de7344d80d2663d9fd3a4cc3ed9
This commit is contained in:
parent
6bc9b90cab
commit
2528762a69
@ -66,37 +66,45 @@ using the Data Movers on the array.
|
|||||||
Pre-configurations on VMAX
|
Pre-configurations on VMAX
|
||||||
~~~~~~~~~~~~~~~~~~~~~~~~~~
|
~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||||
|
|
||||||
#. Enable Unicode on Data Mover.
|
#. Configure a storage pool
|
||||||
|
|
||||||
The VMAX driver requires that the Unicode is enabled on Data Mover.
|
There is a one to one relationship between a storage pool in embedded NAS
|
||||||
|
to a storage group on the VMAX. The best way to provision
|
||||||
|
storage for file is from the Unisphere for VMAX UI rather than eNAS UI.
|
||||||
|
Go to :menuselection:`{array} > SYSTEM > FIle` and under
|
||||||
|
:menuselection:`Actions` click :menuselection:`PROVISION STORAGE FOR FILE`
|
||||||
|
|
||||||
.. warning::
|
.. note::
|
||||||
|
|
||||||
After enabling Unicode, you cannot disable it. If there are some
|
When creating a new storage group you have the ability to assign a
|
||||||
file systems created before Unicode is enabled on the VMAX,
|
service level e.g. Diamond and disable compression/deduplication
|
||||||
consult the storage administrator before enabling Unicode.
|
which is enabled by default.
|
||||||
|
|
||||||
To check the Unicode status on Data Mover, use the following VMAX eNAS File
|
To pick up the newly created storage pool in the eNAS UI,
|
||||||
commands on the VMAX control station:
|
go to :menuselection:`{Control Station} > Storage > Storage Configuration > Storage Pools`
|
||||||
|
and under :menuselection:`File Storage` click :menuselection:`Rescan Storage Systems`
|
||||||
|
|
||||||
|
or on the command line:
|
||||||
|
|
||||||
.. code-block:: console
|
.. code-block:: console
|
||||||
|
|
||||||
server_cifs <MOVER_NAME> | head
|
$ nas_diskmark -mark -all -discovery y -monitor y
|
||||||
# MOVER_NAME = <name of the Data Mover>
|
|
||||||
|
|
||||||
Check the value of I18N mode field. UNICODE mode is shown as
|
The new storage pool should now appear in the eNAS UI
|
||||||
``I18N mode = UNICODE``.
|
|
||||||
|
|
||||||
To enable the Unicode for Data Mover, use the following command:
|
#. Make sure you have the appropriate licenses
|
||||||
|
|
||||||
.. code-block:: console
|
.. code-block:: console
|
||||||
|
|
||||||
uc_config -on -mover <MOVER_NAME>
|
$ nas_license -l
|
||||||
# MOVER_NAME = <name of the Data Mover>
|
key status value
|
||||||
|
site_key online xx xx xx xx
|
||||||
|
nfs online
|
||||||
|
cifs online
|
||||||
|
snapsure online
|
||||||
|
replicatorV2 online
|
||||||
|
filelevelretention online
|
||||||
|
|
||||||
Refer to the document Using International Character Sets on VMAX for
|
|
||||||
File on `EMC support site <http://support.emc.com>`_ for more
|
|
||||||
information.
|
|
||||||
|
|
||||||
#. Enable CIFS service on Data Mover.
|
#. Enable CIFS service on Data Mover.
|
||||||
|
|
||||||
@ -107,9 +115,9 @@ Pre-configurations on VMAX
|
|||||||
|
|
||||||
.. code-block:: console
|
.. code-block:: console
|
||||||
|
|
||||||
server_setup <MOVER_NAME> -Protocol cifs -option start [=<n>]
|
$ server_setup <movername> -Protocol cifs -option start [=<n>]
|
||||||
# MOVER_NAME = <name of the Data Mover>
|
# movername = name of the Data Mover
|
||||||
# n = <number of threads for CIFS users>
|
# n = number of threads for CIFS users
|
||||||
|
|
||||||
.. note::
|
.. note::
|
||||||
|
|
||||||
@ -121,8 +129,8 @@ Pre-configurations on VMAX
|
|||||||
|
|
||||||
.. code-block:: console
|
.. code-block:: console
|
||||||
|
|
||||||
server_cifs <MOVER_NAME> | head
|
$ server_cifs <movername> | head
|
||||||
# MOVER_NAME = <name of the Data Mover>
|
# movername = name of the Data Mover
|
||||||
|
|
||||||
The command output will show the number of CIFS threads started.
|
The command output will show the number of CIFS threads started.
|
||||||
|
|
||||||
@ -137,7 +145,19 @@ Pre-configurations on VMAX
|
|||||||
a share with this security service. There is a limitation that the
|
a share with this security service. There is a limitation that the
|
||||||
time of the domains used by security-services, even for different
|
time of the domains used by security-services, even for different
|
||||||
tenants and different share networks, should be in sync. Time
|
tenants and different share networks, should be in sync. Time
|
||||||
difference should be less than 10 minutes.
|
difference should be less than 5 minutes.
|
||||||
|
|
||||||
|
.. note::
|
||||||
|
|
||||||
|
If there is a clock skew then you may see the following error
|
||||||
|
"The local machine and the remote machine are not synchronized.
|
||||||
|
Kerberos protocol requires a synchronization of both participants
|
||||||
|
within the same 5 minutes". To fix this error you must make sure
|
||||||
|
the times of the eNas controller host and the Domain Controller
|
||||||
|
or within 5 minutes of each other. You must be root to change the
|
||||||
|
date of the eNas control station. Check also that your time zones
|
||||||
|
coincide.
|
||||||
|
|
||||||
|
|
||||||
We recommend setting the NTP server to the same public NTP
|
We recommend setting the NTP server to the same public NTP
|
||||||
server on both the Data Mover and domains used in security services
|
server on both the Data Mover and domains used in security services
|
||||||
@ -147,16 +167,16 @@ Pre-configurations on VMAX
|
|||||||
|
|
||||||
.. code-block:: console
|
.. code-block:: console
|
||||||
|
|
||||||
server_date <MOVER_NAME>
|
$ server_date <movername>
|
||||||
# MOVER_NAME = <name of the Data Mover>
|
# movername = name of the Data Mover
|
||||||
|
|
||||||
Set the NTP server for Data Mover with the following command:
|
Set the NTP server for Data Mover with the following command:
|
||||||
|
|
||||||
.. code-block:: console
|
.. code-block:: console
|
||||||
|
|
||||||
server_date <MOVER_NAME> timesvc start ntp <host> [<host> ...]
|
$ server_date <movername> timesvc start ntp <host> [<host> ...]
|
||||||
# MOVER_NAME = <name of the Data Mover>
|
# movername = name of the Data Mover
|
||||||
# host = <IP address of the time server host>
|
# host = IP address of the time server host
|
||||||
|
|
||||||
.. note::
|
.. note::
|
||||||
|
|
||||||
@ -174,16 +194,16 @@ Pre-configurations on VMAX
|
|||||||
|
|
||||||
.. code-block:: console
|
.. code-block:: console
|
||||||
|
|
||||||
server_usermapper <movername>
|
$ server_usermapper <movername>
|
||||||
# movername = <name of the Data Mover>
|
# movername = name of the Data Mover
|
||||||
|
|
||||||
If usermapper does not start, use the following command
|
If usermapper does not start, use the following command
|
||||||
to start the usermapper:
|
to start the usermapper:
|
||||||
|
|
||||||
.. code-block:: console
|
.. code-block:: console
|
||||||
|
|
||||||
server_usermapper <movername> -enable
|
$ server_usermapper <movername> -enable
|
||||||
# movername = <name of the Data Mover>
|
# movername = name of the Data Mover
|
||||||
|
|
||||||
For a multiple protocol environment, refer to Configuring VMAX eNAS User
|
For a multiple protocol environment, refer to Configuring VMAX eNAS User
|
||||||
Mapping on `EMC support site <http://support.emc.com>`_ for
|
Mapping on `EMC support site <http://support.emc.com>`_ for
|
||||||
@ -194,8 +214,35 @@ Pre-configurations on VMAX
|
|||||||
Find the network devices (physical port on NIC) of the Data Mover that
|
Find the network devices (physical port on NIC) of the Data Mover that
|
||||||
has access to the share network.
|
has access to the share network.
|
||||||
|
|
||||||
To check the device list, go
|
To check the device list on the eNAS UI go
|
||||||
to :menuselection:`Unisphere > Settings > Network > Device`.
|
to :menuselection:`{Control Station} > Settings > Network > Devices`.
|
||||||
|
|
||||||
|
or on the command line:
|
||||||
|
|
||||||
|
.. code-block:: console
|
||||||
|
|
||||||
|
$ server_sysconfig server_2 -pci
|
||||||
|
server_2 : PCI DEVICES:
|
||||||
|
|
||||||
|
On Board:
|
||||||
|
VendorID=0x1120 DeviceID=0x1B00 Controller
|
||||||
|
0: scsi-0 IRQ: 32
|
||||||
|
|
||||||
|
0: scsi-16 IRQ: 33
|
||||||
|
|
||||||
|
0: scsi-32 IRQ: 34
|
||||||
|
|
||||||
|
0: scsi-48 IRQ: 35
|
||||||
|
|
||||||
|
Broadcom 10 Gigabit Ethernet Controller
|
||||||
|
0: fxg-3-0 IRQ: 36
|
||||||
|
speed=10000 duplex=full txflowctl=disable rxflowctl=disable
|
||||||
|
Link: Up
|
||||||
|
|
||||||
|
0: fxg-3-1 IRQ: 38
|
||||||
|
speed=10000 duplex=full txflowctl=disable rxflowctl=disable
|
||||||
|
Link: Down
|
||||||
|
|
||||||
|
|
||||||
Back-end configurations
|
Back-end configurations
|
||||||
~~~~~~~~~~~~~~~~~~~~~~~
|
~~~~~~~~~~~~~~~~~~~~~~~
|
||||||
|
Loading…
Reference in New Issue