ML2 Mechanism Driver for the Cisco APIC
Specification for a new ML2 mechanism driver for the Cisco APIC. Change-Id: I53075e7cf63874060f32d9b9621f0b3410f93cb1
This commit is contained in:
parent
ec31bcfc58
commit
1d24dbd296
230
specs/juno/ml2-cisco-apic-mech-driver.rst
Normal file
230
specs/juno/ml2-cisco-apic-mech-driver.rst
Normal file
@ -0,0 +1,230 @@
|
|||||||
|
=======================================
|
||||||
|
ML2 Mechanism Driver for the Cisco APIC
|
||||||
|
=======================================
|
||||||
|
|
||||||
|
Launchpad blueprint:
|
||||||
|
|
||||||
|
https://blueprints.launchpad.net/neutron/+spec/ml2-cisco-apic-mechanism-driver
|
||||||
|
|
||||||
|
This blueprint is to introduce the Cisco APIC to OpenStack
|
||||||
|
Neutron. The plugin is implemented as an ML2 mechanism driver.
|
||||||
|
|
||||||
|
|
||||||
|
Problem description
|
||||||
|
===================
|
||||||
|
|
||||||
|
The APIC (Application Policy Infrastructure Controller) together with
|
||||||
|
Cisco Nexus 9000 switches provides programmable, policy-driven network
|
||||||
|
control.
|
||||||
|
|
||||||
|
The mechanism driver proposed here will interact with the APIC to
|
||||||
|
dynamically manage networking for OpenStack instances. The APIC will
|
||||||
|
intelligently configure the hardware layer and manage VXLAN overlays
|
||||||
|
for networks. VXLAN gateways will be implemented by the controller at
|
||||||
|
the top of rack layer to reduce encapsulation latency in the software
|
||||||
|
switch layer.
|
||||||
|
|
||||||
|
Use Cases:
|
||||||
|
|
||||||
|
1. Application centric policy based networking
|
||||||
|
2. External controller managed network fabric
|
||||||
|
3. VXLAN Overlay networks
|
||||||
|
|
||||||
|
|
||||||
|
|
||||||
|
Proposed change
|
||||||
|
===============
|
||||||
|
|
||||||
|
The diagram below provides a high level overview of how the APIC
|
||||||
|
plugin will integrate into a working environment consisting of
|
||||||
|
multiple hosts with virtual switches connected by a fabric of Nexus
|
||||||
|
9000 switches. The APIC Mechanism Driver for ML2 communicated with the
|
||||||
|
APIC via its REST API.
|
||||||
|
|
||||||
|
Flows::
|
||||||
|
|
||||||
|
+–––––––––––––––––––––––––+
|
||||||
|
| |
|
||||||
|
| Neutron Server |
|
||||||
|
| with ML2 Plugin |
|
||||||
|
| |
|
||||||
|
| +–––––––––––+ |
|
||||||
|
+–––––––+ | APIC | |
|
||||||
|
| | | Mechanism | | +–––––––––––––––––+
|
||||||
|
| | | Driver | | | |
|
||||||
|
| +––––+ +––+–––––––––––+––+ REST API | Cisco |
|
||||||
|
| | | | APIC Client +––––––––––––––––––+ APIC |
|
||||||
|
| | +–––––––+–––––––––––––––––+ | |
|
||||||
|
| | | |
|
||||||
|
| | +–––+–––+–––––––––+
|
||||||
|
| | +–––––––––––+––––––––––––––+ | |
|
||||||
|
| +––––+ L2 Agent | Open vSwitch +–––––+ | |
|
||||||
|
| +–––––––––––+––––––––––––––+ | | |
|
||||||
|
| | | | | |
|
||||||
|
| | HOST 1 | | | |
|
||||||
|
| | | | +––––––––+–––|––––––+
|
||||||
|
| +––––––––––––––––––––––––––+ | | | |
|
||||||
|
| +––––––+ +–––––––––+––––––+––+
|
||||||
|
| | | |
|
||||||
|
| +––––––––––+–––––––––––––––+ | | Cisco |
|
||||||
|
+–––––––+ L2 Agent | Open vSwitch +––––––––––––+ | Nexus 9000 |
|
||||||
|
+––––––––––+–––––––––––––––+ | | Switches |
|
||||||
|
| | +––+ |
|
||||||
|
| HOST 2 | | |
|
||||||
|
| | +–––––––––––––––––––+
|
||||||
|
+––––––––––––––––––––––––––+
|
||||||
|
|
||||||
|
The APIC mechanism driver updates the APIC with port, network and
|
||||||
|
subnet changes from Neutron. The APIC configures the physical switch
|
||||||
|
fabric.
|
||||||
|
|
||||||
|
The APIC mechanism driver is designed to operate together with the OVS
|
||||||
|
mechanism driver for handling network operations and port binding on
|
||||||
|
the compute nodes.
|
||||||
|
|
||||||
|
The APIC mechanism driver implements the following Neutron events:
|
||||||
|
|
||||||
|
* Port create/update for compute instances. (Note: the driver does not
|
||||||
|
handle port binding -- that is left to the OVS driver.)
|
||||||
|
* Network create/delete.
|
||||||
|
* Subnet create.
|
||||||
|
|
||||||
|
|
||||||
|
Alternatives
|
||||||
|
------------
|
||||||
|
|
||||||
|
An alternative solution would be to develop a monolithic plugin. The
|
||||||
|
biggest advantage of using the ML2 mechanism driver approach is that
|
||||||
|
it allows us to easily use the existing OVS agent for virtual
|
||||||
|
switching.
|
||||||
|
|
||||||
|
Data model impact
|
||||||
|
-----------------
|
||||||
|
|
||||||
|
Three new models are created by this driver. These models are specific
|
||||||
|
to this driver and are used for keeping in sync with the APIC.
|
||||||
|
|
||||||
|
1. NetworkEPG: Tracks network to End Point Group mapping in the APIC.
|
||||||
|
|
||||||
|
2. PortProfile: Tracks hardware switch/module/port configuration.
|
||||||
|
|
||||||
|
3. TenantContract: Tracks contracts and filters created on the APIC.
|
||||||
|
|
||||||
|
A database migration is included to create the tables for these
|
||||||
|
models.
|
||||||
|
|
||||||
|
No existing models are changed.
|
||||||
|
|
||||||
|
REST API impact
|
||||||
|
---------------
|
||||||
|
|
||||||
|
None.
|
||||||
|
|
||||||
|
Security impact
|
||||||
|
---------------
|
||||||
|
|
||||||
|
None.
|
||||||
|
|
||||||
|
Notifications impact
|
||||||
|
--------------------
|
||||||
|
|
||||||
|
None.
|
||||||
|
|
||||||
|
Other end user impact
|
||||||
|
---------------------
|
||||||
|
|
||||||
|
None.
|
||||||
|
|
||||||
|
Performance Impact
|
||||||
|
------------------
|
||||||
|
|
||||||
|
The performance of ML2 when configured with the APIC driver will be
|
||||||
|
dependent on the performance of the link between Neutron and the APIC,
|
||||||
|
and on the responsiveness of the APIC itself.
|
||||||
|
|
||||||
|
Other deployer impact
|
||||||
|
---------------------
|
||||||
|
|
||||||
|
The deployer must configure the installation to use the APIC with the
|
||||||
|
following configuration variables:
|
||||||
|
|
||||||
|
* IP address and port number of the APIC.
|
||||||
|
* Username and password to login as administrator to the APIC.
|
||||||
|
* VLAN namespace and ranges to be used for OpenStack.
|
||||||
|
* Node, entity and function profiles describing the switch fabric
|
||||||
|
infrastructure.
|
||||||
|
* Switch-to-host mappings for the compute nodes.
|
||||||
|
|
||||||
|
Additionally, the deployer must configure the ML2 plugin to include
|
||||||
|
the openvswitch mechanism driver before the APIC mechanism driver:
|
||||||
|
|
||||||
|
::
|
||||||
|
|
||||||
|
[ml2]
|
||||||
|
mechanism_drivers = openvswitch,cisco_apic
|
||||||
|
|
||||||
|
Developer impact
|
||||||
|
----------------
|
||||||
|
|
||||||
|
None.
|
||||||
|
|
||||||
|
Implementation
|
||||||
|
==============
|
||||||
|
|
||||||
|
Assignee(s)
|
||||||
|
-----------
|
||||||
|
|
||||||
|
Arvind Somya <asomya>
|
||||||
|
|
||||||
|
Henry Gessau <gessau>
|
||||||
|
|
||||||
|
Work Items
|
||||||
|
----------
|
||||||
|
|
||||||
|
The work is split up into two parts:
|
||||||
|
|
||||||
|
1. APIC Client, models, configuration, unit tests.
|
||||||
|
|
||||||
|
* The APIC Client is a REST Client to the APIC. It maps requests
|
||||||
|
to the "Managed Object" model of the APIC. Only the subset of
|
||||||
|
the full APIC model needed by the driver is provided.
|
||||||
|
|
||||||
|
2. APIC mechanism driver and supporting code.
|
||||||
|
|
||||||
|
* The mechanism driver implements the port, network and subnet
|
||||||
|
methods that affect the APIC. It maps Neutron operations into
|
||||||
|
operations for the APIC.
|
||||||
|
* Supporting code consists of an APIC manager that ensures the
|
||||||
|
APIC state is in sync with Neutron.
|
||||||
|
|
||||||
|
|
||||||
|
Dependencies
|
||||||
|
============
|
||||||
|
|
||||||
|
There are no new library requirements. The following third party
|
||||||
|
library is used:
|
||||||
|
|
||||||
|
* requests
|
||||||
|
|
||||||
|
|
||||||
|
Testing
|
||||||
|
=======
|
||||||
|
|
||||||
|
Complete unit test coverage of the code is included.
|
||||||
|
|
||||||
|
For tempest test coverage, third party testing is provided. The Cisco
|
||||||
|
CI reports on all changes affecting this driver. The testing is run in
|
||||||
|
a setup with an OpenStack deployment (devstack) connected to a live
|
||||||
|
APIC and a Cisco Nexus 9000 physical switch.
|
||||||
|
|
||||||
|
|
||||||
|
Documentation Impact
|
||||||
|
====================
|
||||||
|
|
||||||
|
Configuration details.
|
||||||
|
|
||||||
|
|
||||||
|
References
|
||||||
|
==========
|
||||||
|
|
||||||
|
http://www.cisco.com/go/apic
|