Patch Set 1: (3 inline comments)

>Also, I would like to see something more about how connection of the external device would happen at the data plane.

This is what the attachment identifier is for. When a port is created as a result of a physical port attachment, the port object will be extended with the attachment information. The implementation can then use this to configure physical switch port access modes to match it to the provider network.

Patch-set: 1
This commit is contained in:
Gerrit User 7787 2014-04-17 22:09:55 +00:00 committed by Gerrit Code Review
parent 8e3de9bf32
commit de7b43f96e
1 changed files with 54 additions and 0 deletions

View File

@ -17,6 +17,24 @@
"serverId": "4a232e18-c5a9-48ee-94c0-e04e7cca6543",
"unresolved": false
},
{
"key": {
"uuid": "AAAAXH//uRg\u003d",
"filename": "specs/juno/neutron-baremetal-compute.rst",
"patchSetId": 1
},
"lineNbr": 69,
"author": {
"id": 7787
},
"writtenOn": "2014-04-17T22:09:55Z",
"side": 1,
"message": "This is used by the implementation to locate the port in oder to connect it up to the network. \n\nIt would be something like \"Switch1 Port5\".",
"parentUuid": "AAAAXH//uWw\u003d",
"revId": "36ee7ef12afdaa80f61e8cfecad5c19557ae8ec9",
"serverId": "4a232e18-c5a9-48ee-94c0-e04e7cca6543",
"unresolved": false
},
{
"key": {
"uuid": "AAAAXH//uWY\u003d",
@ -34,6 +52,24 @@
"serverId": "4a232e18-c5a9-48ee-94c0-e04e7cca6543",
"unresolved": false
},
{
"key": {
"uuid": "AAAAXH//uRw\u003d",
"filename": "specs/juno/neutron-baremetal-compute.rst",
"patchSetId": 1
},
"lineNbr": 71,
"author": {
"id": 7787
},
"writtenOn": "2014-04-17T22:09:55Z",
"side": 1,
"message": "We allow the port to be deleted. This is how the tenant will disconnect the physical port from the network since they are not allowed to delete physical ports.",
"parentUuid": "AAAAXH//uWY\u003d",
"revId": "36ee7ef12afdaa80f61e8cfecad5c19557ae8ec9",
"serverId": "4a232e18-c5a9-48ee-94c0-e04e7cca6543",
"unresolved": false
},
{
"key": {
"uuid": "AAAAXH//3dk\u003d",
@ -121,6 +157,24 @@
"serverId": "4a232e18-c5a9-48ee-94c0-e04e7cca6543",
"unresolved": false
},
{
"key": {
"uuid": "AAAAXH//uS0\u003d",
"filename": "specs/juno/neutron-baremetal-compute.rst",
"patchSetId": 1
},
"lineNbr": 126,
"author": {
"id": 7787
},
"writtenOn": "2014-04-17T22:09:55Z",
"side": 1,
"message": "This was to allow an admin to assign a port to a different tenant without having to re-enter all of the identification information.",
"parentUuid": "AAAAXH//ubI\u003d",
"revId": "36ee7ef12afdaa80f61e8cfecad5c19557ae8ec9",
"serverId": "4a232e18-c5a9-48ee-94c0-e04e7cca6543",
"unresolved": false
},
{
"key": {
"uuid": "AAAAXH//3cg\u003d",