b7c303ee0a
- during live migration on pre migration step nova plugs instance vif device on the destination compute node; - L2 agent on destination host detects new device and requests device info from server; - server does not change port status since port is bound to another host (source host); - L2 agent processes device and sends update_device_up to server; - again server does not update status as port is bound to another host; Nova notifications are sent only in case port status change so in this case no notifications are sent. The fix is to explicitly notify nova if agent reports device up from a host other than port's current host. This is the fix on neutron side, the actual fix of the bug is on nova side: change-id Ib1cb9c2f6eb2f5ce6280c685ae44a691665b4e98 Closes-Bug: #1414559 Change-Id: Ifa919a9076a3cc2696688af3feadf8d7fa9e6fc2 |
||
---|---|---|
.. | ||
common | ||
ml2 | ||
__init__.py |