Integration With Off-path Network Backends
|
||||
==========================================
|
||||
|
||||
https://blueprints.launchpad.net/nova/+spec/integration-with-off-path-network-backends
|
||||
|
||||
Off-path SmartNIC DPUs introduce an architecture change where
|
||||
network agents responsible for NIC switch configuration and representor
|
||||
interface plugging run on a separate SoC with its own CPU, memory and that runs
|
||||
a separate OS kernel. The side-effect of that is that hypervisor hostnames no
|
||||
longer match SmartNIC DPU hostnames which are seen by ovs-vswitchd and OVN [3]_
|
||||
agents while the existing port binding code relies on that. The goal of this
|
||||
specification is to introduce changes necessary to extend the existing hardware
|
||||
offload code to cope with the hostname mismatch and related design challenges
|
||||
while reusing the rest of the code. To do that, PCI(e) add-in card tracking is
|
||||
introduced for boards with unique serial numbers so that it can be used to
|
||||
determine the correct hostname of a SmartNIC DPU which is responsible for a
|
||||
particular VF. Additionally, more information is suggested to be passed in the
|
||||
"binding:profile" during a port update to facilitate representor port plugging.
|
||||
|
||||
|
||||
Problem description
|
||||
===================
|
||||
|
||||
Terminology
|
||||
-----------
|
||||
|
||||
* Data Processing Unit (DPU) - an embedded system that includes a CPU, a NIC
|
||||
and possibly other components on its board which integrates with the main
|
||||
board using some I/O interconnect (e.g. PCIe);
|
||||
* Off-path SmartNIC DPU architecture [1]_ [2]_ - an architecture where NIC
|
||||
cores are responsible for programming a NIC Switch and are bypassed when
|
||||
rules programmed into the NIC Switch are enough to make a decision on where
|
||||
to deliver packets. Normally, NIC cores only participate in packet forwarding
|
||||
for the "slow path" only and the "fast path" is handled in hardware like an
|
||||
ASIC;
|
||||
* On-path SmartNIC DPU architecture [1]_ [2]_ - an architecture where NIC cores
|
||||
participate in processing of every packet going through the NIC as a whole.
|
||||
In other words, NIC cores are always on the "fast path" of all packets;
|
||||
* NIC Switch (or eSwitch) - a programmable embedded switch present in various
|
||||
types of NICs (SR-IOV-capable NICs, off-path SmartNICs). Typically relies
|
||||
on ASICs for packet processing;
|
||||
* switchdev [4]_ - in-kernel driver model for switch devices which offload the
|
||||
forwarding (data) plane from the kernel.
|
||||
* Representor ports [5]_ - a concept introduced in the switchdev model which
|
||||
models netdevs representing switch ports. This applies to NIC switch ports
|
||||
(which can be physical uplink ports, PFs or VFs);
|
||||
* devlink [6]_ - a kernel API to expose device information and resources not
|
||||
directly related to any device class, such as chip-wide/switch-ASIC-wide
|
||||
configuration;
|
||||
* PCI/PCIe Vital Product Data (VPD) - a standard capability exposed by PCI(e)
|
||||
endpoints which, among other information, includes a unique serial number
|
||||
(read-only, persistent, factory-generated) of a card shared by all functions
|
||||
exposed by it. Present in PCI local bus 2.1+ and PCIe 4.0+ specifications.
|
||||
|
||||
Detailed overview
|
||||
-----------------
|
||||
|
||||
Cross-project changes have been made over time to support SR-IOV VF allocation
|
||||
and VF allocation in the context of supporting OVS hardware offload [7]_ with
|
||||
switchdev-capable NICs. However, further work is needed in order to support
|
||||
off-path SmartNIC DPUs which also expose PCI(e) functions to the hypervisor
|
||||
hosts.
|
||||
|
||||
When working with ports of type "direct", instance creation involves several
|
||||
key steps, including:
|
||||
|
||||
* Creating the necessary context based on a client request (including PCI
|
||||
device requests, e.g. based on "direct" ports associated with an instance
|
||||
creation request or extra specs of a flavor);
|
||||
* Selecting the right host for the instance to be scheduled;
|
||||
|
||||
* In the switchdev-capable NIC case: based on availability of devices with
|
||||
the "switchdev" capability of PciDevices recorded in the Nova DB;
|
||||
* Building and running the instance, which involves:
|
||||
|
||||
* Claiming PCI resources via the ResourceTracker at the target host based on
|
||||
InstancePCIRequests created beforehand;
|
||||
* Building other resource requests and updating Neutron port information,
|
||||
specifically:
|
||||
|
||||
* binding_host_id with the hypervisor hostname;
|
||||
* binding:profile details with PCI device information,
|
||||
namely: pci_vendor_info, pci_slot, physical_network;
|
||||
|
||||
* Network device assignment for the newly created instance and vif plugging
|
||||
|
||||
* in the switchdev-capable NIC case this involves plugging a VF representor
|
||||
port into the right OVS bridge;
|
||||
* programming the necessary flows into the NIC Switch.
|
||||
|
||||
The rest of the description will focus on illustrating why this process needs
|
||||
improvements to support off-path SmartNIC DPUs.
|
||||
|
||||
Off-path SmartNIC DPUs provide a dedicated CPU for NIC Switch programming on
|
||||
which a dedicated OS is set to run which is separate from the OS running on the
|
||||
main board. A system with one SmartNIC in a multi-CPU system with PCIe
|
||||
bifurcation used for the add-in card is shown below::
|
||||
|
||||
┌──────────────────────────────┐
|
||||
│ Main host (hypervisor) │
|
||||
│ ┌──────┐ ┌──────┐ │
|
||||
│ │ CPU1 │ │ CPU2 │ │
|
||||
│ │ RC1 │ │ RC2 │ │
|
||||
│ └───┬──┘ └───┬──┘ │
|
||||
│ │ │ │
|
||||
└────────┼─────────────┼───────┘
|
||||
│ │
|
||||
│ │
|
||||
┌───┴────┐ ┌───┴────┐
|
||||
IO interconnect 1 │PF NUMA1│ │PF NUMA2│ IO interconnect 2
|
||||
(PCIe) │VFs │ │VFs │ (PCIe)
|
||||
└────┬───┘ └───┬────┘
|
||||
│ │
|
||||
┌────────────────────────────────┼────────────┼──────────────────────┐
|
||||
│SmartNIC DPU Board ▲ │ │ ▲ │
|
||||
│ │ │ │ │ Fast path │
|
||||
│ ┌─────────────┐ ┌─┴────────────┴─┐ │
|
||||
│ │ Application │e.g. PCIe│ NIC Switch │ ┌────────────┐ │
|
||||
│ │ CPU ├─────────┤ ASIC ├─────┤uplink ports│ │
|
||||
│ │ RC3 │ ├────────────────┤ └────────────┘ │
|
||||
│ ┌────┴──────┬──────┘ ◄──── │ Management CPU │ │
|
||||
│ │OOB Port │ Slow path│ Firmware │ │
|
||||
│ └───────────┘ └────────────────┘ │
|
||||
│ │
|
||||
│ │
|
||||
└────────────────────────────────────────────────────────────────────┘
|
||||
|
||||
With off-path SmartNIC DPUs, if a NIC Switch has the necessary flows
|
||||
programmed and an incoming packet matches those flows, it is delivered to the
|
||||
destination over the fast path bypassing the "Application CPU". Otherwise, the
|
||||
packet is processed in software at the Application CPU and then forwarded to
|
||||
the destination.
|
||||
|
||||
There are more sophisticated scenarios as well:
|
||||
|
||||
* Two or more SmartNIC DPUs per server attached to different NUMA nodes;
|
||||
* A blade system with managed PCIe switches providing SR-IOV function sharing
|
||||
of PFs/VFs of the same add-in-card to different compute servers:
|
||||
|
||||
* MR-SR-IOV/PCIe Shared IO [8]_.
|
||||
|
||||
Networking agents (e.g. ovs-vswitchd and ovn-controller) are expected to run
|
||||
on the SmartNIC OS which will have a different hostname from the hypervisor
|
||||
OS which results in a mismatch during port binding (more specifically to the
|
||||
OVS case, the external_ids["hostname"] field in the Open_vSwitch table differs
|
||||
from the hypervisor hostname). Likewise, representor plugging and flow
|
||||
programming happens on the SmartNIC host, not on the hypervisor host. As a
|
||||
result, Nova (with the help of os-vif) can no longer be responsible for VIF
|
||||
plugging in the same way. For instance, compared to the OVS hardware offload
|
||||
scenario, OVS bridges and port representors are no longer exposed to the
|
||||
hypervisor host OS. In summary, no networking agents are present on the
|
||||
hypervisor host in this architecture. In this scenario the noop os-vif
|
||||
plugin can be used to avoid explicit actions at the Nova host side, while
|
||||
a different service at the SmartNIC DPU side will be responsible for
|
||||
plugging of representors into the right bridge. However, Nova is still
|
||||
responsible for passing the device information to the virt driver so that
|
||||
it can be used when starting an instance.
|
||||
|
||||
Since Nova and networking agents run on different hosts, there needs to be a
|
||||
set of interactions in order to:
|
||||
|
||||
* Schedule an instance to a host where a VF with the necessary capability is
|
||||
present;
|
||||
* Select a suitable VF at the hypervisor host side and create a PCI device
|
||||
claim for it;
|
||||
* Run the necessary logic as described in the Neutron specification [19]_.
|
||||
|
||||
The SmartNIC DPU selection in particular becomes an issue to address due to
|
||||
the following:
|
||||
|
||||
* PF and VF mac addresses can be reprogrammed so they cannot be used as
|
||||
reliable persistent identifiers to refer to SmartNIC DPUs;
|
||||
* PCI(e) add-in cards themselves do not have entries in sysfs but PCI(e)
|
||||
endpoints do;
|
||||
* When a SmartNIC DPU uses PCIe to access the PCIe endpoints exposed by the
|
||||
NIC, hypervisor hosts and SmartNIC DPU hosts do not see the same set of PCIe
|
||||
functions as they see **isolated PCIe topologies**. Each host enumerates the
|
||||
PCIe topology it is able to observe. While the same NIC is exposed to both
|
||||
topologies, the set of functions and config spaces observed by hosts differs.
|
||||
|
||||
* Note that SmartNIC DPUs may have different ways of accessing a
|
||||
switchdev-capable NIC: via PCIe, a platform device or other means of I/O.
|
||||
The hypervisor host would see PCIe endpoints regardless of that but relying
|
||||
on PCI addresses in the implementation to match functions and their
|
||||
representors is not feasible.
|
||||
|
||||
In order to track SmartNIC DPUs and associations of PFs/VFs with them, there
|
||||
is a need for a unique and persistent identifier that is discoverable from both
|
||||
hypervisor hosts and SmartNIC DPU hosts. PCI (2.1+) and PCIe specifications
|
||||
define the Vital Product Data (VPD) capability which includes a serial number
|
||||
field which is defined to be unique and read-only for a given add-in card. All
|
||||
PFs and VFs exposed by a PCI(e) card share the same VPD data (whether it is
|
||||
exposed on PFs only or VFs is firmware-specific). However, this field is
|
||||
currently not gathered by the virt drivers or recorded by the Nova
|
||||
PciResourceTracker (note: SmartNIC DPUs from several major vendors are known
|
||||
to provide VPD with serial numbers filled in and visible from hypervisor hosts
|
||||
and SmartNIC DPU hosts).
|
||||
|
||||
The serial number information exposed via PCI(e) VPD is also available via
|
||||
devlink-info - there are no ties to a particular IO standard such as PCI(e) so
|
||||
other types of devices (e.g. platform devices) could leverage this as well.
|
||||
|
||||
For the PCI(e) use-case specifically, there is a need to distinguish the
|
||||
PFs/VFs that simply expose a VPD from the ones that also need to be associated
|
||||
with SmartNIC DPUs. In order to address that, PCI devices can be tagged using
|
||||
the ``pci_passthrough_whitelist`` to show that they are associated with a
|
||||
SmartNIC DPU.
|
||||
|
||||
Reliance on the "switchdev" capability (persisted into the extra_info column
|
||||
of pci_devices table) is also problematic since the PFs exposed to a hypervisor
|
||||
host by the NIC on a SmartNIC DPU board do not provide access to the NIC
|
||||
Switch - it is not possible to query whether the NIC Switch is in the "legacy"
|
||||
or "switchdev" mode from the hypervisor side. This has to do with NIC internals
|
||||
and the way the same NIC is exposed to hypervisor host CPUs and the
|
||||
"application CPU" on the add-in card. Devlink documentation in the kernel
|
||||
provides an example of that with two PCIe hierarchies: [9]_.
|
||||
|
||||
Use Cases
|
||||
---------
|
||||
|
||||
* The main use-case is to support allocation of VFs associated with off-path
|
||||
SmartNIC DPUs and their necessary configuration at the SmartNIC DPU side;
|
||||
* From the operator perspective, being able to use multiple SmartNIC DPUs per
|
||||
host is desirable.
|
||||
|
||||
Desired Outcome Overview
|
||||
------------------------
|
||||
|
||||
The following points summarize the desired outcome:
|
||||
|
||||
* **Off-path** SmartNIC DPUs from various vendors where networking control
|
||||
plane components are meant to run on SmartNIC DPU hosts;
|
||||
* Reuse of the existing VNIC type "smart-nic" (VNIC_SMARTNIC);
|
||||
* A new tag for PCI devices to indicate that a device is associated with a
|
||||
SmartNIC DPU: ``remote_managed=True|False``;
|
||||
* Support for multiple SmartNIC DPUs per host;
|
||||
* No expectation that the hypervisor host will be responsible for placing an
|
||||
image onto a SmartNIC DPU directly;
|
||||
|
||||
* a security boundary is assumed between the main board host and the
|
||||
SmartNIC/DPU;
|
||||
* Indirect communication between Nova and software running on the SmartNIC
|
||||
DPU;
|
||||
* Focus on the libvirt virt driver for any related changes initially but make
|
||||
the design generic for other virt drivers to follow;
|
||||
|
||||
Configuration and deployment of the SmartNIC DPU and its control plane software
|
||||
on it is outside the scope of this spec.
|
||||
|
||||
Proposed change
|
||||
===============
|
||||
|
||||
The scope of this change is in Nova but it is a part of a larger effort that
|
||||
involves OVN and Neutron.
|
||||
|
||||
Largely, the goal is to gather the information necessary for representor
|
||||
plugging via Nova and pass it to the right place.
|
||||
|
||||
In case PCIe used at the SmartNIC DPU for NIC access, both the hypervisor host
|
||||
and the SmartNIC DPU host that belong to the same physical machine can see
|
||||
PCI(e) functions exposed by the controllers on the same card, therefore, they
|
||||
can see the same unique add-in-card serial number exposed via VPD. For other
|
||||
types of I/O, devlink-info can be relied upon to retrieve the board serial
|
||||
(if available). This change, however, is focused on the PCI and will use PCI
|
||||
VPD info as seen by Libvirt.
|
||||
|
||||
Nova can store the information about the observed cards and use it later during
|
||||
the port update process to affect the selection of a SmartNIC DPU host that
|
||||
will be used for representor plugging.
|
||||
|
||||
Device tags in the ``pci_passthrough_whitelist`` will tell Nova which PCI
|
||||
vendor and device IDs refer to functions belonging to a SmartNIC DPU.
|
||||
|
||||
The following needs to be addressed in the implementation:
|
||||
|
||||
* Store VPD info from the PCI(e) capability for each PciDevice;
|
||||
|
||||
* card_serial_number - a string of up to 255 bytes since PCI and PCIe specs
|
||||
use a 1-byte length field for the SN;
|
||||
* ``extra_info: '{"capabilities": "vpd": {"card_serial_number": "<sn>"}]'}``;
|
||||
* Retrieval of the PCI card serial numbers stored in PCI VPD as presented in
|
||||
node device XML format exposed by Libvirt for PFs and VFs.
|
||||
|
||||
* Whether or not PCI VPD is exposed for VFs as well as PFs is specific to
|
||||
the device firmware (sometimes there is an NVRAM option to enable to expose
|
||||
this data on VFs in addition to PFs) - it might be useful to populate
|
||||
VF-specific information based on the PF information in case PCI VPD is not
|
||||
exposed for VFs;
|
||||
* Store the card serial number information (if present) in the PciDevice
|
||||
extra_info column under the "vpd" capability;
|
||||
* Extend the ``pci_passthrough_whitelist`` handling implementation to take
|
||||
``remote_managed=True|False`` tag into account;
|
||||
* For each function added to an instance, collect a PF MAC and VF logical
|
||||
number as seen by the hypervisor host and pass them to Neutron along with
|
||||
the card serial number during port update requests that happen during
|
||||
instance creation (see the relevant section below for more details);
|
||||
|
||||
* Note that if VFIO is used, this specification assumes that the ``vfio-pci``
|
||||
driver will only be bound to VFs, not PFs and that PFs will be utilized for
|
||||
hypervisor host purposes (e.g. connecting to the rest of the control
|
||||
plane);
|
||||
* Storing of VF logical number and PF MAC could be in ``extra_info`` could
|
||||
be done to avoid extra database lookups;
|
||||
* Add logic to handle ports of type ``VNIC_SMARTNIC`` ("smart-nic");
|
||||
* Add a new Nova service version constant (``SUPPORT_VNIC_TYPE_SMARTNIC``) and
|
||||
an instance build-time check (in ``_validate_and_build_base_options``) to
|
||||
make sure that instances with this port type are scheduled only when all
|
||||
compute services in all cells have this service version;
|
||||
|
||||
* The service version check will need to be triggered only for network
|
||||
requests containing port_ids that have ``VNIC_TYPE_SMARTNIC`` port type.
|
||||
Nova will need to learn to query the port type by its ID to perform that
|
||||
check;
|
||||
* Add a new compute driver capability called ``supports_remote_managed_ports``
|
||||
and a respective ``COMPUTE_REMOTE_MANAGED_PORTS`` trait to ``os-traits``;
|
||||
|
||||
* Only the Libvirt driver will be set to have this trait since this is the
|
||||
first driver to support ``remote_managed`` ports;
|
||||
* Implement a prefilter that will check for the presence of port ids that have
|
||||
``VNIC_TYPE_SMARTNIC`` port type and add the ``COMPUTE_REMOTE_MANAGED_PORTS``
|
||||
to the request spec in this case. This will make sure that instances are
|
||||
scheduled on compute nodes that have the necessary virt driver supporting
|
||||
remote managed ports enabled;
|
||||
* Add stubs in the Nova API to prevent the following lifecycle operations for
|
||||
instances with VNIC_TYPE_SMARTNIC ports:
|
||||
|
||||
* Resize;
|
||||
* Shelve;
|
||||
* Live migrate;
|
||||
* Evacuate;
|
||||
* Suspend;
|
||||
* Attach/detach a VNIC_TYPE_SMARTNIC port;
|
||||
* Rebuild;
|
||||
* Extend ``VIF.has_bind_time_event`` in Nova to return True for
|
||||
VNIC_TYPE_SMARTNIC ports;
|
||||
* Handle early arrival of ``network-vif-plugged`` in the Libvirt virt driver
|
||||
code for ``VNIC_TYPE_SMARTNIC`` ports by extending the
|
||||
``_get_neutron_events`` function to rely on ``VIF.has_bind_time_event`` for
|
||||
filtering.
|
||||
|
||||
Identifying Port Representors
|
||||
-----------------------------
|
||||
|
||||
This specification makes an assumption that Neutron will be extended to act
|
||||
upon the additional information passed from Nova. The following set of
|
||||
information is proposed to be sent during a port update:
|
||||
|
||||
* card serial number;
|
||||
* PF mac address (seen both by the hypervisor host and the SmartNIC DPU host);
|
||||
* VF logical number.
|
||||
|
||||
This is needed to do the following multiplexing decisions:
|
||||
|
||||
* Determining the right SmartNIC DPU hostname associated with a chosen VF.
|
||||
There may be multiple SmartNIC DPUs per physical host. This can be done by
|
||||
associating a card serial number with a SmartNIC DPU hostname at the Neutron
|
||||
& OVN side (Nova just needs to pass it in a port update);
|
||||
* Picking the right NIC Switch at the SmartNIC DPU side. PF logical numbers
|
||||
are tied to controllers [9]_ [11]_. Typically there is a single NIC and
|
||||
NIC Switch in a SmartNIC but there is no guarantee that there will not be a
|
||||
device with multiple of those. As a result, just passing a PF logical number
|
||||
from the hypervisor host is not enough to determine the right NIC Switch.
|
||||
A PF MAC address could be used as a way to get around the lack of visibility
|
||||
of a controller at the hypervisor host side;
|
||||
* Choosing the right VF representor - a VF logical number tied to a particular
|
||||
PF.
|
||||
|
||||
PF and controller numbers seen by the SmartNIC DPU are not visible from the
|
||||
hypervisor host since it does not see the NIC Switch. To further expand on
|
||||
this, the devlink [10]_ infrastructure in the kernel supports different port
|
||||
flavors (quoted descriptions originate from linux/uapi/linux/devlink.h [12]_):
|
||||
|
||||
* physical - "any kind of a port physically facing the user". PFs on the
|
||||
hypervisor side and uplink ports on the SmartNIC DPU will have this flavor;
|
||||
* virtual - "any virtual port facing the user". VFs on the hypervisor side will
|
||||
have this flavor;
|
||||
* pcipf - an NIC Switch port representing a port of PCI PF;
|
||||
* pcivf - an NIC Switch port representing a port of PCI VF.
|
||||
|
||||
Linux kernel exposes logical numbers via devlink differently for different
|
||||
port flavors:
|
||||
|
||||
* physical and virtual flavors: via DEVLINK_ATTR_PORT_NUMBER - this value is
|
||||
driver-specific and depends on how a device driver populates those
|
||||
attributes.
|
||||
* pcipf and pcivf flavors: DEVLINK_ATTR_PORT_PCI_PF_NUMBER and
|
||||
DEVLINK_ATTR_PORT_PCI_VF_NUMBER attributes.
|
||||
|
||||
For example, for a NIC with 2 uplink ports with sriov_numvfs set to 4 for
|
||||
both uplink ports at the hypervisor side, the set of interfaces as shown by
|
||||
``devlink port`` will be as follows::
|
||||
|
||||
pci/0000:05:00.0/1: type eth netdev enp5s0f0 flavour physical port 0
|
||||
pci/0000:05:00.1/1: type eth netdev enp5s0f1 flavour physical port 1
|
||||
pci/0000:05:02.3/1: type eth netdev enp5s0f1np0v0 flavour virtual port 0
|
||||
pci/0000:05:02.4/1: type eth netdev enp5s0f1np0v1 flavour virtual port 0
|
||||
pci/0000:05:02.5/1: type eth netdev enp5s0f1np0v2 flavour virtual port 0
|
||||
pci/0000:05:02.6/1: type eth netdev enp5s0f1np0v3 flavour virtual port 0
|
||||
pci/0000:05:00.3/1: type eth netdev enp5s0f0np0v0 flavour virtual port 0
|
||||
pci/0000:05:00.4/1: type eth netdev enp5s0f0np0v1 flavour virtual port 0
|
||||
pci/0000:05:00.5/1: type eth netdev enp5s0f0np0v2 flavour virtual port 0
|
||||
pci/0000:05:00.6/1: type eth netdev enp5s0f0np0v3 flavour virtual port 0
|
||||
|
||||
Notice the virtual port indexes are all set to 0 - in this example the device
|
||||
driver does not provide any indexing information via devlink attributes for
|
||||
"virtual" ports.
|
||||
|
||||
SmartNIC DPU host ``devlink port`` output::
|
||||
|
||||
pci/0000:03:00.0/262143: type eth netdev p0 flavour physical port 0
|
||||
pci/0000:03:00.0/196608: type eth netdev pf0hpf flavour pcipf pfnum 0
|
||||
pci/0000:03:00.0/196609: type eth netdev pf0vf0 flavour pcivf pfnum 0 vfnum 0
|
||||
pci/0000:03:00.0/196610: type eth netdev pf0vf1 flavour pcivf pfnum 0 vfnum 1
|
||||
pci/0000:03:00.0/196611: type eth netdev pf0vf2 flavour pcivf pfnum 0 vfnum 2
|
||||
pci/0000:03:00.0/196612: type eth netdev pf0vf3 flavour pcivf pfnum 0 vfnum 3
|
||||
pci/0000:03:00.1/327679: type eth netdev p1 flavour physical port 1
|
||||
pci/0000:03:00.1/262144: type eth netdev pf1hpf flavour pcipf pfnum 1
|
||||
pci/0000:03:00.1/262145: type eth netdev pf1vf0 flavour pcivf pfnum 1 vfnum 0
|
||||
pci/0000:03:00.1/262146: type eth netdev pf1vf1 flavour pcivf pfnum 1 vfnum 1
|
||||
pci/0000:03:00.1/262147: type eth netdev pf1vf2 flavour pcivf pfnum 1 vfnum 2
|
||||
pci/0000:03:00.1/262148: type eth netdev pf1vf3 flavour pcivf pfnum 1 vfnum 3
|
||||
|
||||
So the logical numbers for representor flavors are correctly identified at the
|
||||
SmartNIC DPU but are not visible at the hypervisor host.
|
||||
|
||||
VF PCI addresses at the hypervisor side are calculated per the PCIe and SR-IOV
|
||||
specs using the PF PCI address, "First VF Offset" and "VF Stride" values and
|
||||
the logical per-PF numbering is maintained by the kernel and exposed via sysfs.
|
||||
Therefore, we can take logical VF numbers from the following sysfs entries::
|
||||
|
||||
/sys/bus/pci/devices/{pf_pci_addr}/virtfn<vf_logical_num>
|
||||
|
||||
They can also be accessed via::
|
||||
|
||||
/sys/bus/pci/devices/{vf_pci_addr}/physfn/virtfn<vf_logical_num>
|
||||
|
||||
Finding the right entry via a physfn symlink can be done by resolving virtfn
|
||||
symlinks one by one and comparing the result with the ``vf_pci_addr`` that
|
||||
is of interest.
|
||||
|
||||
As for finding the right PF representor by a MAC address of hypervisor host PF,
|
||||
it depends on the availability of information about a mapping of a hypervisor
|
||||
PF MAC to a PF representor MAC.
|
||||
|
||||
VF logical number and PF MAC information can be extracted at runtime right
|
||||
before a port update since those are done by the Nova Compute manager during
|
||||
instance creation. Alternatively, it can be stored in the database in
|
||||
``extra_info`` of a PciDevice.
|
||||
|
||||
VF VLAN Programming Considerations
|
||||
----------------------------------
|
||||
|
||||
Besides NIC Switch capability not being exposed to the hypervisor host,
|
||||
SmartNIC DPUs also prevent VLAN programming by for VFs, therefore, operations
|
||||
like the following will fail (see, [27]_ for the example driver code causing
|
||||
it)::
|
||||
|
||||
sudo ip link set enp130s0f0 vf 2 vlan 0 mac de:ad:be:ef:ca:fe
|
||||
RTNETLINK answers: Operation not permitted
|
||||
|
||||
In this case the VF MAC programming is allowed by the driver, however, VLAN
|
||||
programming is not.
|
||||
|
||||
Nova does not tell Libvirt to program VLANs for VIFs with
|
||||
``VIFHostDeviceDevType.ETHERNET`` [28]_ (it explicitly passes ``None`` for the
|
||||
vlan parameter to [29]_) which are going to be used in the implementation.
|
||||
|
||||
Libvirt only programs a specific VLAN number for hostdev ports [30]_
|
||||
(``VIR_DOMAIN_NET_TYPE_HOSTDEV`` [31]_) if one is provided via device XML and
|
||||
otherwise tries to clear a VLAN by passing a VLAN ID 0 to the ``RTM_SETLINK``
|
||||
operation (handing of ``EPERM`` in this case is addressed by [22]_).
|
||||
|
||||
Nova itself only programs a MAC address and VLAN for ``VNIC_TYPE_MACVTAP``
|
||||
ports [32]_ [33]_, therefore, the implementation of this specification does
|
||||
not need to introduce any changes for that.
|
||||
|
||||
Alternatives
|
||||
------------
|
||||
|
||||
The main points that were considered when looking for alternatives:
|
||||
|
||||
* Code reuse: a lot of work went into the hardware offload implementation and
|
||||
extending it without introducing new services and projects would be
|
||||
preferable;
|
||||
* Security and isolation: SmartNICs DPUs are isolated from the hypervisor host
|
||||
intentionally to create a security boundary between the hypervisor services
|
||||
and network services. Creating agents to drive provisioning and configuration
|
||||
from the hypervisor itself would remove that benefit;
|
||||
* NIC Switch configuration and port plugging: services running on a
|
||||
SmartNIC DPU need to participate in port representor plugging and NIC Switch
|
||||
programming which is not necessarily specific to Nova or even OpenStack.
|
||||
Other infrastructure projects may benefit from that as well so the larger
|
||||
effort needs to concentrate on reusability. This is why possible
|
||||
introduction of SmartNIC DPU-level services specific to OpenStack needs to be
|
||||
avoided (i.e. it is better to extend OVN to do that and handle VF plugging at
|
||||
the Nova side).
|
||||
|
||||
One alternative approach involves tracking cards using a separate service with
|
||||
its own API and possibly introducing a different VNIC type: this does not have
|
||||
a benefit of code reuse and requires another service to be added and integrated
|
||||
with Nova and Neutron at minimum. Evolving the work that was done to enable
|
||||
hardware offloaded ports seems like a more effective way to address this
|
||||
use-case.
|
||||
|
||||
Supporting one SmartNIC DPU per host initially and extending it at a later
|
||||
point has been discarded due to difficulties in the data model extension.
|
||||
|
||||
Data model impact
|
||||
-----------------
|
||||
|
||||
PciDevices get additional information associated with them without affecting
|
||||
the DB model:
|
||||
|
||||
* a "vpd" capability which stores the information available in the PCI(e) VPD
|
||||
capability (initially, just the board serial number but it may be extended at
|
||||
a later point if needed).
|
||||
|
||||
Periodic hypervisor resource updates will add newly discovered PciDevices and
|
||||
get the associated card serial number information. However, old devices will
|
||||
not get this information without explicit action.
|
||||
|
||||
|
||||
REST API impact
|
||||
---------------
|
||||
|
||||
N/A
|
||||
|
||||
Security impact
|
||||
---------------
|
||||
|
||||
N/A
|
||||
|
||||
Notifications impact
|
||||
--------------------
|
||||
|
||||
N/A
|
||||
|
||||
Other end user impact
|
||||
---------------------
|
||||
|
||||
N/A
|
||||
|
||||
Performance Impact
|
||||
------------------
|
||||
|
||||
* Additional steps need to be performed to extract serial number information of
|
||||
PCI(e) add-in cards from the PFs and VFs exposed by them.
|
||||
|
||||
Other deployer impact
|
||||
---------------------
|
||||
|
||||
Reading PCI(e) device VPD is supported since kernel 2.6.26
|
||||
(see kernel commit 94e6108803469a37ee1e3c92dafdd1d59298602f) and devices
|
||||
that support PCI local bus 2.1+ (and any PCIe revision) use the same binary
|
||||
format for it. The VPD capability is optional per the PCI(e) specs, however,
|
||||
production SmartNICs/DPUs observed so far do contain it (engineering samples
|
||||
may not have VPD so only use generally available hardware for this).
|
||||
|
||||
During the deployment planning it is also important to take control traffic
|
||||
paths into account. Nova compute is expected to pass information to Neutron
|
||||
for port binding via the control network: Neutron is then responsible for
|
||||
interacting with OVN which then propagates the necessary information to
|
||||
ovn-controllers running at SmartNIC DPU hosts. Also, Placement service updates
|
||||
from hypervisor nodes happen over the control network. This may happen via
|
||||
dedicated ports programmed on the eSwitch which needs to be done via some form
|
||||
of a deployment automation. Alternatively, LoMs on many motherboards may be
|
||||
used for that communication but the overall goal is to remove the need for
|
||||
that. The OOB port on the SmartNIC DPU (if present) may be used for control
|
||||
communication too but it is assumed that it will be used for PXE boot of an OS
|
||||
running on the application CPU and for initial NIC Switch configuration. Which
|
||||
interfaces to use for control traffic is outside of the scope of this
|
||||
specification and the purpose of this comment is to illustrate the possible
|
||||
indirect communication paths between components running on different hosts
|
||||
within the same physical machine and remote services::
|
||||
|
||||
|
||||
┌────────────────────────────────────┐
|
||||
│ Hypervisor │ LoM Ports
|
||||
│ ┌───────────┐ ┌───────────┐ │ (on-board,
|
||||
│ │ Instance │ │ Nova │ ├──┐ optional)
|
||||
│ │ (QEMU) │ │ Compute │ │ ├─────────┐
|
||||
│ │ │ │ │ ├──┘ │
|
||||
│ └───────────┘ └───────────┘ │ │
|
||||
│ │ │
|
||||
└────────────────┬─┬───────┬─┬──┬────┘ │
|
||||
│ │ │ │ │ │
|
||||
│ │ │ │ │ Control Traffic │
|
||||
Instance VF │ │ │ │ │ PF associated │
|
||||
│ │ │ │ │ with an uplink │
|
||||
│ │ │ │ │ port or a VF. │
|
||||
│ │ │ │ │ (used to replace│
|
||||
│ │ │ │ │ LoM) │
|
||||
┌────────────────────────────────────┼─┼───────┼─┼──┼─┐ │
|
||||
│ SmartNIC DPU Board │ │ │ │ │ │ │
|
||||
│ │ │ │ │ │ │ │
|
||||
│ ┌──────────────┐ Control traffic │ │ │ │ │ │ │
|
||||
│ │ App. CPU │ via PFs or VFs ┌┴─┴───────┴─┴┐ │ │ │
|
||||
│ ├──────────────┤ (DC Fabric) │ │ │ │ │
|
||||
│ │ovn-controller├─────────────────┼─┐ │ │ │ │
|
||||
│ ├──────────────┤ │ │ │ │ │ │
|
||||
│ │ovs-vswitchd │ Port │ │NIC Switch │ │ │ │
|
||||
│ ├──────────────┤ Representors │ │ ASIC │ │ │ │
|
||||
│ │ br-int ├─────────────────┤ │ │ │ │ │
|
||||
│ │ ├─────────────────┤ │ │ │ │ │
|
||||
│ └──────────────┘ │ │ │ │ │ │
|
||||
│ │ │ │ │ │ │
|
||||
│ └─┼───┬─┬─────┘ │ │ │
|
||||
┌─┴──────┐Initial NIC Switch │ │ │ │ │ │
|
||||
─┤OOB Port│configuration is done via │ │ │uplink │ │ │
|
||||
└─┬──────┘the OOB port to create │ │ │ │ │ │
|
||||
│ ports for control traffic. │ │ │ │ │ │
|
||||
└─────────────────────────────────────┼───┼─┼───────┼─┘ │
|
||||
│ │ │ │ │
|
||||
┌──┼───┴─┴───────┼────────┐ │
|
||||
│ │ │ │ │
|
||||
│ │ DC Fabric ├────────┼────────┘
|
||||
│ │ │ │
|
||||
└──┼─────────────┼────────┘
|
||||
│ │
|
||||
│ ┌───┴──────┐
|
||||
│ │ │
|
||||
┌───▼──┐ ┌───▼───┐ ┌────▼────┐
|
||||
│OVN SB│ │Neutron│ │Placement│
|
||||
└──────┘ │Server │ │ │
|
||||
└───────┘ └─────────┘
|
||||
|
||||
Processes on the hypervisor host would use the PF associated with an uplink
|
||||
port or a bond (or VLAN interfaces on top of those) in order to communicate
|
||||
with control processes.
|
||||
|
||||
SmartNIC DPUs themselves do not typically have a BMC themselves and draw
|
||||
primary power from a PCIe slot so their power lifecycle is tied to the
|
||||
main board lifecycle. This should be taken into consideration when performing
|
||||
power off/power on operations on the hypervisor hosts as it will affect
|
||||
services running on the SmartNIC DPU (a reboot of the hypervisor host should
|
||||
not).
|
||||
|
||||
Developer impact
|
||||
----------------
|
||||
|
||||
The current specification targets the libvirt driver - other virt drivers
|
||||
need to gain similar functionality to discover card serial numbers if they
|
||||
want to support the same workflow.
|
||||
|
||||
Upgrade impact
|
||||
--------------
|
||||
|
||||
Nova Service Versions
|
||||
~~~~~~~~~~~~~~~~~~~~~
|
||||
|
||||
The ``Proposed Change`` section discusses adding a service version constant
|
||||
(``SUPPORT_VNIC_TYPE_SMARTNIC``) and an instance build-time check across all
|
||||
cells. For operators, the upgrade impact will be such that this feature will
|
||||
not be possible to use until all Nova Compute services will be upgraded to
|
||||
support this service version.
|
||||
|
||||
Neutron integration
|
||||
~~~~~~~~~~~~~~~~~~~
|
||||
|
||||
This section focuses on operational concerns with regards to Neutron being able
|
||||
to support instances booted with the ``VNIC_TYPE_SMARTNIC`` port type.
|
||||
|
||||
At the time of writing, only the OVS mechanism driver supports [13]_
|
||||
``VNIC_TYPE_SMARTNIC`` ports but only if a particular configuration option is
|
||||
set in the Neutron OpenvSwitch Agent (which was done for Ironic purposes, not
|
||||
Nova [14]_).
|
||||
|
||||
Therefore, in the absence of mechanism drivers that would support ports of that
|
||||
type or when the mechanism driver is not configured to handle ports of that
|
||||
type, port binding will fail.
|
||||
|
||||
This change also relies on the use of ``binding:profile`` [15]_ which
|
||||
does not have a strict format and documented as::
|
||||
|
||||
A dictionary that enables the application running on the specific host to
|
||||
pass and receive vif port information specific to the networking back-end.
|
||||
The networking API does not define a specific format of this field.
|
||||
|
||||
Therefore, no Neutron API changes are needed to support additional attributes
|
||||
specified passed by Nova in port updates.
|
||||
|
||||
Implementation
|
||||
==============
|
||||
|
||||
Assignee(s)
|
||||
-----------
|
||||
|
||||
Primary assignee:
|
||||
dmitriis
|
||||
|
||||
Other contributors:
|
||||
fnordahl, james-page
|
||||
|
||||
Feature Liaison
|
||||
---------------
|
||||
|
||||
Liaison Needed
|
||||
|
||||
Work Items
|
||||
----------
|
||||
|
||||
* Support the PCI ``vpd`` capability exposed by Libvirt via node device XML;
|
||||
* Implement modifications to store the card serial number information
|
||||
associated with PciDevices;
|
||||
* Modify the ``pci_passthrough_whitelist`` to include the ``remote_managed``
|
||||
tag handling;
|
||||
* Add handling for ``VNIC_SMARTNIC`` VNIC type;
|
||||
* Implement VF logical number extraction based on virtfn entries in sysfs:
|
||||
``/sys/bus/pci/devices/{pf_pci_addr}/virtfn<vf_logical_num>``;
|
||||
* Extend the port update procedure to pass an add-in-card serial number,
|
||||
PF mac and VF logical number to Neutron in the ``binding:profile`` attribute;
|
||||
* Implement service version checking for the added functionality;
|
||||
* Implement a prefilter to avoid scheduling instances to nodes that do not
|
||||
support the right compute capability;
|
||||
* Unit testing coverage;
|
||||
* Function tests for the added functionality;
|
||||
* Integration testing with other projects.
|
||||
|
||||
|
||||
Dependencies
|
||||
============
|
||||
|
||||
In order to make this useful overall there are additional cross-project
|
||||
changes required. Specifically, to make this work with OVN:
|
||||
|
||||
* ovn-controller needs to learn how to plug representors into correct bridges
|
||||
at the SmartNIC DPU node side since the os-vif-like functionality to hook VFs
|
||||
up is still needed;
|
||||
|
||||
* Representor plugging and related OVN changes: [16]_ [17]_ [24]_ (note that
|
||||
[24]_ will be hosted at [25]_ shortly per [26]_ and a follow-up discussion
|
||||
that happened in the #openvswitch IRC channel);
|
||||
* The OVN driver code in Neutron needs to learn about SmartNIC DPU node
|
||||
hostnames and respective PCIe add-in-card serial numbers gathered via VPD:
|
||||
|
||||
* Port binding needs to be aware of the hypervisor and SmartNIC DPU
|
||||
hostname mismatches and mappings between card serial numbers and SmartNIC
|
||||
DPU node hostnames. The relevant Neutron RFE is in the ``rfe-approved``
|
||||
state [18]_ the relevant Neutron specification is published at
|
||||
[19]_, while the code for it is tracked in [20]_);
|
||||
* Libvirt supports parsing PCI/PCIe VPD and as of October 2021 [21]_ and
|
||||
exposes a serial number if it is present in the VPD;
|
||||
* Libvirt tries to clear a VLAN if one is not specified (trying to set VLAN ID
|
||||
to 0), however, some SmartNIC DPUs do not allow the hypervisor host to do
|
||||
that since the privileged NIC switch control is not provided to it. A patch
|
||||
to Libvirt [22]_ addresses this issue.
|
||||
|
||||
Future Work
|
||||
-----------
|
||||
|
||||
Similar to the hardware offload [7]_ functionality, this specification does
|
||||
not address operational concerns around the selection of a particular device
|
||||
family. The specification proposing PCI device tracking in the placement
|
||||
service [23]_ could be a step in that direction, however, it would likely
|
||||
require Neutron extensions as well that would allow specifying requested device
|
||||
traits in metadata associated with ports.
|
||||
|
||||
Testing
|
||||
=======
|
||||
|
||||
* Unit testing of the added functionality;
|
||||
* Functional tests will need to be extended to support additional cases related
|
||||
to the added functionality;
|
||||
|
||||
|
||||
Documentation Impact
|
||||
====================
|
||||
|
||||
* Nova admin guide needs to be extended to discuss ``remote_managed`` tags;
|
||||
* Cross-project documentation needs to be written: Neutron and deployment
|
||||
project guides need to be updated to discuss how to deploy a cloud with
|
||||
SmartNIC DPUs.
|
||||
|
||||
References
|
||||
==========
|
||||
|
||||
.. [1] https://netdevconf.info/0x14/pub/slides/39/Netdev%200x14%20--%20Taking%20Control%20of%20your%20SmartNIC%20v1.pdf
|
||||
.. [2] https://homes.cs.washington.edu/~arvind/papers/ipipe.pdf
|
||||
.. [3] https://man7.org/linux/man-pages/man7/ovn-architecture.7.html
|
||||
.. [4] https://www.kernel.org/doc/Documentation/networking/switchdev.txt
|
||||
.. [5] https://lwn.net/Articles/692942/
|
||||
.. [6] https://www.kernel.org/doc/html/latest/networking/devlink/index.html
|
||||
.. [7] https://docs.openstack.org/neutron/latest/admin/config-ovs-offload.html;
|
||||
.. [8] https://www.snia.org/sites/default/orig/DSI2015/presentations/Rev/Jeff%20DodsonSNIA_Tutorial_PCIe_Shared_IO_2015_revision.pdf
|
||||
.. [9] https://www.kernel.org/doc/html/latest/networking/devlink/devlink-port.html#pci-controllers
|
||||
.. [10] https://www.kernel.org/doc/html/latest/networking/devlink/devlink-port.html#devlink-port
|
||||
.. [11] https://git.kernel.org/pub/scm/linux/kernel/git/torvalds/linux.git/commit/?id=66b17082d10a3b806eec3da8fdebe8a9cd2c6612
|
||||
.. [12] https://github.com/torvalds/linux/blob/v5.12/include/uapi/linux/devlink.h#L191-L206
|
||||
.. [13] https://opendev.org/openstack/neutron/src/tag/19.0.0/neutron/plugins/ml2/drivers/mech_agent.py#L109-L116
|
||||
.. [14] https://opendev.org/openstack/ironic-specs/commit/f358fbdde9a1cadc838327b8bf34ee54a7e7f43a
|
||||
.. [15] https://docs.openstack.org/api-ref/network/v2/index.html?expanded=create-port-detail#id72
|
||||
.. [16] https://patchwork.ozlabs.org/project/ovn/list/?series=267834&state=3&archive=both
|
||||
.. [17] https://patchwork.ozlabs.org/project/ovn/list/?series=269965&state=*&archive=both
|
||||
.. [18] https://bugs.launchpad.net/neutron/+bug/1932154
|
||||
.. [19] https://review.opendev.org/c/openstack/neutron-specs/+/788821
|
||||
.. [20] https://review.opendev.org/c/openstack/neutron/+/808961
|
||||
.. [21] https://gitlab.com/libvirt/libvirt/-/commits/master?search=PCI.*VPD
|
||||
.. [22] https://listman.redhat.com/archives/libvir-list/2021-November/msg00431.html
|
||||
.. [23] https://review.opendev.org/c/openstack/nova-specs/+/791047
|
||||
.. [24] https://github.com/fnordahl/ovn-vif
|
||||
.. [25] https://github.com/ovn-org/ovn-vif
|
||||
.. [26] https://mail.openvswitch.org/pipermail/ovs-dev/2021-November/389200.html
|
||||
.. [27] https://github.com/torvalds/linux/blob/v5.15/drivers/net/ethernet/mellanox/mlx5/core/esw/legacy.c#L427-L434
|
||||
.. [28] https://github.com/openstack/nova/blob/e28afc564700a1a35e3bf0269687d5734251b88a/nova/virt/libvirt/vif.py#L479-L485
|
||||
.. [29] https://github.com/openstack/nova/blob/e28afc564700a1a35e3bf0269687d5734251b88a/nova/virt/libvirt/designer.py#L97-L105
|
||||
.. [30] https://github.com/libvirt/libvirt/blob/7e6295cc7db2b11b28af7f4ef644f2dd30ea6840/src/conf/domain_conf.c#L29411-L29425
|
||||
.. [31] https://github.com/libvirt/libvirt/blob/7e6295cc7db2b11b28af7f4ef644f2dd30ea6840/src/conf/domain_conf.h#L904
|
||||
.. [32] https://github.com/openstack/nova/blob/e28afc564700a1a35e3bf0269687d5734251b88a/nova/virt/libvirt/vif.py#L628-L640
|
||||
.. [33] https://github.com/openstack/nova/blob/e28afc564700a1a35e3bf0269687d5734251b88a/nova/virt/libvirt/vif.py#L94-L102
|
Loading…
Reference in New Issue