PCI device tracking in Placement
This change introduces a spec to describe modeling of PCI device using Placement. Blueprint: pci-device-tracking-in-placement Co-Authored-By: Sean Mooney <smooney@redhat.com> Change-Id: I6c822427031b6162b3ead8562256d2e80f9070b4
This commit is contained in:
parent
d345f4dbd4
commit
480346c85b
|
@ -0,0 +1,755 @@
|
|||
..
|
||||
This work is licensed under a Creative Commons Attribution 3.0 Unported
|
||||
License.
|
||||
|
||||
http://creativecommons.org/licenses/by/3.0/legalcode
|
||||
|
||||
================================
|
||||
PCI Device Tracking In Placement
|
||||
================================
|
||||
|
||||
https://blueprints.launchpad.net/nova/+spec/pci-device-tracking-in-placement
|
||||
|
||||
The OpenStack Placement service was designed to provide tracking
|
||||
of quantitative resources via resource class inventories and qualitative
|
||||
characteristics via traits. Over the last few cycles, nova has utilized
|
||||
Placement to track basic resources such as CPUs, RAM, and disk, and more
|
||||
complex resources such as Virtual GPUs. This spec describes how Nova can
|
||||
utilize Placement to track generic PCI devices without going into the details
|
||||
of the NUMA awareness of such devices.
|
||||
|
||||
Problem description
|
||||
===================
|
||||
|
||||
Nova has supported generic stateless PCI passthrough for many releases using a
|
||||
dedicated PCI tracker in conjunction with a ``PciPassthroughFilter`` scheduler
|
||||
post filter.
|
||||
|
||||
The PCI tracker is responsible for tracking which PCI devices are available,
|
||||
claimed, and allocated, the capabilities of the device, its consumer when
|
||||
claimed or allocated as well as the type of PCI device and location.
|
||||
|
||||
The ``PciPassthroughFilter`` is responsible for ensuring that devices,
|
||||
requested by the VM, exist on a host during scheduling. These PCI requests come
|
||||
from two sources: flavor-based PCI requests that are generated using the
|
||||
``pci_passthrough:alias`` `flavor extra specs`_ and neutron based PCI requests
|
||||
generated from SR-IOV backed neutron ports.
|
||||
|
||||
.. _`flavor extra specs`: https://docs.openstack.org/nova/latest/configuration/extra-specs.html#pci_passthrough:alias
|
||||
|
||||
While the current approach to PCI tracking works there are some limitations
|
||||
in the current design and there is room for optimization.
|
||||
|
||||
.. rubric:: Limitations
|
||||
|
||||
* During server creation PCI devices are not claimed until the instance_claim
|
||||
is created on the compute node. As a result, it is possible for two
|
||||
concurrent server create requests to race for the last device on a host
|
||||
resulting in re-schedules.
|
||||
|
||||
* While Nova today tracks the capabilities of network interfaces in the
|
||||
``extra_info`` field of the ``pci_devices`` table and the
|
||||
``PciPassthroughFilter`` could match on those capabilities there is no
|
||||
user-facing way to express a request for an SR-IOV neutron port with a
|
||||
specific network capability e.g. TSO.
|
||||
|
||||
* There is no admin-facing interface to check the available and allocated PCI
|
||||
resources in the cloud. The only way is to look into the Nova database.
|
||||
|
||||
.. rubric:: Optimizations
|
||||
|
||||
* Today when the virt driver is assigning a PCI device on the compute hosts
|
||||
it needs to look at all available PCI devices on the host and select one that
|
||||
fulfills the PCI and NUMA requirements. If we model PCI devices in Placement
|
||||
we only need to consider the devices associated with the PCI resource
|
||||
allocation in Placement.
|
||||
|
||||
* Today when we schedule we perform host filtering of viable hosts based on
|
||||
PCI devices in python. By utilizing Placement we can move that filtering to
|
||||
SQL.
|
||||
|
||||
Use Cases
|
||||
---------
|
||||
|
||||
- As an operator I want instance creation to atomically claim resources to
|
||||
decrease the chance of retries.
|
||||
|
||||
- As an operator, I want to shorten the time it takes to select a host by
|
||||
running fewer filters.
|
||||
|
||||
- As an operator, I want to utilize traits and resource classes to model
|
||||
PCI aliases and requests for more expressive device management.
|
||||
|
||||
- As an operator, I want to be able to associate quotas with PCI device usage.
|
||||
|
||||
- As an operator, I want to be able to use the Placement API to query available
|
||||
and allocated PCI devices in my cloud.
|
||||
|
||||
.. note::
|
||||
|
||||
Device quotas would require unified limits to be implemented. Implementing
|
||||
quotas is out of the scope of this spec beyond enabling the use case by
|
||||
modeling PCI devices in Placement.
|
||||
|
||||
This spec will also only focus on flavor-based PCI passthrough. Neutron
|
||||
SR-IOV port will be addressed in a follow-up spec to limit the scope.
|
||||
|
||||
Proposed change
|
||||
===============
|
||||
|
||||
Opt-in reporting of PCI devices in Placement
|
||||
--------------------------------------------
|
||||
|
||||
To support upgrade of existing deployments with PCI passthrough configured
|
||||
and to be able to deprecate and eventually remove some of the functionality of
|
||||
the current PCI device tracker the new Placement based PCI device tracking will
|
||||
be disabled by default in the first release. The new
|
||||
``[pci]report_in_placement`` config option can be used to enable the
|
||||
functionality. It will be defaulted to ``False`` first and once it is turned to
|
||||
``True`` nova-compute will refuse to start if disabled again. In a future
|
||||
release, after the PCI tracking in Placement is feature complete, the default
|
||||
will be changed to ``True``.
|
||||
|
||||
PCI device_spec configuration
|
||||
-----------------------------
|
||||
|
||||
Below we propose a change to the ``[pci]passthrough_whitelist`` configuration
|
||||
option. While we are making this change we will take this opportunity to
|
||||
update the name of the configuration option. The old name of the
|
||||
``[pci]passthrough_whitelist`` config option will be deprecated for eventual
|
||||
removal and a new name ``[pci]device_spec`` will be added. Both the
|
||||
old and the new name will support the newly proposed ``resource_class`` and
|
||||
``traits`` tags.
|
||||
|
||||
The syntax of the `PCI passthrough device list`_ configuration option will be
|
||||
extended to support two additional standard tags ``resource_class`` and
|
||||
``traits``. These new tags will only take effect if the
|
||||
``[pci]report_in_placement`` config option is set to ``True``.
|
||||
|
||||
.. code-block:: js
|
||||
|
||||
device_spec = {
|
||||
"vendor_id": "1002",
|
||||
"product_id": "67FF",
|
||||
"resource_class":"CUSTOM_GPU",
|
||||
"traits": "CUSTOM_RADEON_RX_560", "CUSTOM_GDDR5"
|
||||
}
|
||||
device_spec = {
|
||||
"address": "0000:82:00.0",
|
||||
"resource_class":"CUSTOM_FPGA",
|
||||
"traits": "CUSTOM_XILINX_XC7VX690T"
|
||||
}
|
||||
|
||||
|
||||
The ``resource_class`` tag will be accepted only when the ``physical_network``
|
||||
tag is not defined and will enable a PCI device to be associated with a custom
|
||||
resource class. Each PCI whitelist entry may have at most one resource class
|
||||
associated with it. Devices that have a ``physical_network`` tag will not be
|
||||
reported in Placement at this time as Neutron based SR-IOV is out of the
|
||||
scope of the current spec.
|
||||
|
||||
Where a PCI device does not have a ``physical_network`` or a ``resource_class``
|
||||
tag present it will be reported with a generated custom resource class.
|
||||
The resource class will be ``CUSTOM_PCI_<vendor_id>_<product_id>``.
|
||||
|
||||
The ``traits`` tag will be a comma-separated list of standard or custom trait
|
||||
names that will be reported for the device RP in Placement.
|
||||
|
||||
Nova will normalize and prefix the resource class and trait names with
|
||||
``CUSTOM_``, if isn't already prefixed, before creating them in Placement.
|
||||
Nova will first check the provided trait name in os_traits and if it exists
|
||||
as a standard trait then that will be used instead of creating a custom one.
|
||||
|
||||
.. note::
|
||||
|
||||
Initially traits will only be additive, in the future if we need to we can
|
||||
allow traits to be removed using a +/- syntax but this is not included
|
||||
in the scope of this spec.
|
||||
|
||||
As detailed in the `Modeling PCI devices in Placement`_ section, each
|
||||
physical device (PF) will be its own resource provider with inventories of
|
||||
the relevant PF and VF resource classes. As such traits cannot vary per VF
|
||||
device under the same parent PF. If VFs are individually matched by different
|
||||
``device_spec`` entries, then defining different ``traits`` for different
|
||||
VFs under the same PF is a configuration error and will be rejected.
|
||||
|
||||
While it would possible to support defining different ``resource_class``
|
||||
names for different VFs under the same parent PF, this is considered bad
|
||||
practice and unnecessary complexity. Such configuration will be rejected.
|
||||
|
||||
If different traits need to be supported on a PF than its children VFs
|
||||
then it is suggested to match the PF and its VFs in two separate
|
||||
``device_spec`` entries and differentiate the PF and VF traits by namespacing
|
||||
them, e.g.: CUSTOM_PCI_PF_XXX and CUSTOM_PCI_VF_YYY
|
||||
|
||||
.. note::
|
||||
|
||||
Nova will detect if the ``resource_class`` or ``traits`` configuration of
|
||||
an already reported device is changed at a nova-compute service restart. If
|
||||
the affected device is free the Nova will apply the change in Placement but
|
||||
if the device is already allocated then the nova-compute service will refuse
|
||||
to start.
|
||||
|
||||
.. note::
|
||||
|
||||
In the future when PCI tracking in Placement will be extended to device_spec
|
||||
entries with ``physical_network`` tag, these entries will not allow
|
||||
specifying a ``resource_class`` but nova will use the standard
|
||||
``SRIOV_NET_VF``, ``PCI_NETDEV`` and ``VDPA_NETDEV`` classes. This will
|
||||
not prevent type-VF and type-PF devices to be consumed via PCI alias, as the
|
||||
alias can request these standard resource classes too.
|
||||
|
||||
.. _`PCI passthrough device list`: https://docs.openstack.org/nova/latest/configuration/config.html#pci.passthrough_whitelist
|
||||
|
||||
The new Placement based PCI tracking feature won't support the ``devname`` tag
|
||||
in the ``[pci]device_spec`` configuration. Usage of this tag is already limited
|
||||
as not all PCI devices has a device name. Also ``devname`` only works
|
||||
properly if the names are kept stable across hypervisor reboots and upgrades.
|
||||
If the ``[pci]report_in_placement`` is set to ``True`` and the
|
||||
``[pci]device_spec`` has any entry with ``devname`` tag then the nova-compute
|
||||
service will refuse to start.
|
||||
|
||||
Modeling PCI devices in Placement
|
||||
----------------------------------
|
||||
|
||||
PCI device modeling in Placement will closely mirror that of vGPUs.
|
||||
Each PCI device of type ``type-PCI`` and ``type-PF`` will be modeled as a
|
||||
Placement resource provider (RP) with the name
|
||||
``<hypervisor_hostname>_<pci_address>``. The hypervisor_hostname prefix will be
|
||||
the same string as the name of the root RP. The pci_address part of the
|
||||
name will be the full PCI address in the same format of ``DDDD:BB:AA.FF``.
|
||||
|
||||
.. note::
|
||||
|
||||
The pGPU RPs are using the libvirt nodedev name but this spec is not try to
|
||||
follow that naming scheme as the libvirt nodedev names are not considered
|
||||
stable. Also nova always uses the RP UUID to identify and RP instead of its
|
||||
name. So these names are only for troubleshooting purposes.
|
||||
|
||||
Each PCI device RP will have an inventory of resource class and traits based
|
||||
on the ``[pci]device_spec`` entry matching with the given device. If the device
|
||||
has children devices (VFs) matching with any ``device_spec`` entry then the
|
||||
resource inventory and traits of the children will be reported to the parent PF
|
||||
RP too.
|
||||
|
||||
If a PCI device is matching a ``device_spec`` entry without a
|
||||
``physical_network`` tag then an inventory of 1 is reported of the
|
||||
``resource_class`` specified in the matching ``device_spec`` entry or if
|
||||
``resource_class`` is not specified there then with the generated
|
||||
``CUSTOM_PCI_<vendor_id>_<product_id>`` resource class.
|
||||
|
||||
If a ``type-VF`` device is matching a ``device_spec`` entry then the related
|
||||
resource inventory will be reported on RP representing its parent PF device.
|
||||
The PF RP will be created even if the ``type-PF`` device is not matching any
|
||||
``device_spec`` entry but in that case, only VF inventory will exist on the RP.
|
||||
|
||||
If multiple VFs from the same parent PF is matching the ``device_spec`` then
|
||||
the total resource inventory of VFs will be the total number of matching VF
|
||||
devices.
|
||||
|
||||
Each PCI device RP will have traits reported according to the ``traits`` tag
|
||||
of the matching ``device_spec`` entry. Nova might report additional traits on
|
||||
the device RP automatically for scheduling purposes.
|
||||
|
||||
Listing both the parent PF device and any of this children VF devices at the
|
||||
same time will not be support if ``[pci]report_in_placement`` is enabled. See
|
||||
`Dependent device handling`_ section for more details.
|
||||
|
||||
.. note::
|
||||
|
||||
Even though neutron-requested PCI devices are out of the scope of this spec
|
||||
the handling of ``type-PF`` and ``type-VF`` devices cannot be ignored as
|
||||
those device types can also be requested via PCI alias by setting the
|
||||
``device_type`` tag accordingly.
|
||||
|
||||
.. note::
|
||||
|
||||
The PCI alias can only request devices based on ``vendor_id`` and
|
||||
``product_id`` today and that information will be automatically included in
|
||||
the Placement inventory as the resource class.
|
||||
|
||||
.. note::
|
||||
|
||||
In the future Nova can be extended to automatically report PCI device
|
||||
capabilities as custom traits in placement. However this is out of scope of
|
||||
the current spec. If needed the deployer can add these traits via the
|
||||
``[pci]device_spec`` configuration manually.
|
||||
|
||||
|
||||
Reporting inventories from libvirt to Placement
|
||||
-----------------------------------------------
|
||||
|
||||
The resource tracker's ``update_available_resource`` periodic task calls the
|
||||
``update_provider_tree`` method on the libvirt virt driver. The
|
||||
implementation of ``update_provider_tree`` in the libvirt virt driver will be
|
||||
extended to create the relevant PF RPs, and report inventories and traits via
|
||||
the ``provider_tree`` interface to Placement.
|
||||
|
||||
When ``update_provider_tree`` is called during compute service startup (via
|
||||
init_host) the virt driver will do a reshape of the provider tree to make sure
|
||||
that existing VMs with PCI allocation will have the corresponding resource
|
||||
allocation in Placement as well.
|
||||
|
||||
.. note::
|
||||
|
||||
The compute restart logic needs to handle the case when a device is not
|
||||
present any more either due to changes in the ``[pci]device_spec`` config
|
||||
option or due to a physical device removal from the hypervisor. The driver
|
||||
needs to modify the VF resource inventory on the PF RP (when a VF is removed)
|
||||
or delete the PF RP (if the PF is removed and no children VFs matched). Nova
|
||||
cannot prevent the removal of a PCI device from the hypervisor while the
|
||||
device is allocated to a VM. Still Nova will emit a warning in such case.
|
||||
|
||||
PCI alias configuration
|
||||
-----------------------
|
||||
|
||||
The `PCI alias definition`_ in ``[pci]alias`` configuration option will be
|
||||
extended to support two new tags, ``resource_class``, ``traits``. The
|
||||
``resource_class`` tag can hold exactly one resource class name. While the
|
||||
``traits`` tag can hold a comma-separated list of trait names. Also trait names
|
||||
in ``traits`` can be prefixed with ``!`` to express a forbidden trait.
|
||||
When the ``resource_class`` is specified, the ``vendor_id`` and ``product_id``
|
||||
tags will no longer be required.
|
||||
|
||||
.. note::
|
||||
|
||||
If both ``resource_class`` and ``vendor_id`` and ``product_id`` fields are
|
||||
provided in the alias then Nova will use the ``resource_class`` for the
|
||||
Placement query but the ``vendor_id`` and ``product_id`` filtering will
|
||||
happen in the ``PciPassthroughFilter``.
|
||||
|
||||
.. note::
|
||||
|
||||
Later if more complex trait requirements are needed we can add support for
|
||||
multiple ``traits`` tag by adding a free postfix. Also later we can add
|
||||
support for ``in:`` prefix in the value of the ``traits`` tag to express
|
||||
an OR relationship. E.g.
|
||||
|
||||
.. code-block:: js
|
||||
|
||||
{
|
||||
"traits1": "T1,!T2",
|
||||
"traits2": "in:T3,T4"
|
||||
}
|
||||
|
||||
.. _`PCI alias definition`: https://docs.openstack.org/nova/latest/configuration/config.html#pci.alias
|
||||
|
||||
Requesting PCI devices
|
||||
----------------------
|
||||
|
||||
The syntax and handling of the ``pci_passthrough:alias`` `flavor extra specs`_
|
||||
will not change. Also, Nova will continue using the ``InstancePCIRequest`` to
|
||||
track the requested PCI devices for a VM.
|
||||
|
||||
Scheduling
|
||||
----------
|
||||
|
||||
A new prefilter will be added to convert ``InstancePCIRequest`` requests into
|
||||
Placement resource requests. Each PCI request will be its own Placement named
|
||||
request group. If a PCI request comes from a PCI alias and the alias does not
|
||||
have a ``resource_class`` associated with it it will be computed using the
|
||||
``vendor_id`` and ``product_id`` ``CUSTOM_PCI_<vendor_id>_<product_id>``.
|
||||
|
||||
The prefilter will be disabled by default to enable rolling
|
||||
upgrades. There will be a new config option ``[scheduler]pci_prefilter`` that
|
||||
can be used to enable the prefilter. Enabling that prefilter has a list of
|
||||
prerequisites. See the `Upgrade impact`_ section for the full upgrade
|
||||
procedure.
|
||||
|
||||
.. note::
|
||||
|
||||
For now the prefilter will only create request groups from PCI requests
|
||||
coming from the flavor. PCI requests coming from Neutron ports will be
|
||||
ignored by the prefilter and kept scheduled by the ``PciPassthroughFilter``.
|
||||
|
||||
|
||||
Dependent device handling
|
||||
-------------------------
|
||||
|
||||
Today nova allows matching both a parent PF and its children VFs in the
|
||||
configuration and these devices are tracked as separate resources. However,
|
||||
they cannot be consumed independently. When the PF is consumed its children VFs
|
||||
become unavailable. Also when a VF is consumed its parent PF becomes
|
||||
unavailable. This dynamic device type selection will be deprecated and the new
|
||||
Placement based PCI tracking will only allow configuring either the PF device
|
||||
or its children VF devices. The old PCI tracker will continue support this
|
||||
functionality but as soon as ``[pci]report_in_placement`` is set to True on a
|
||||
compute that compute will reject configurations that are enabling both the PF
|
||||
and in children VFs.
|
||||
|
||||
PCI NUMA affinity
|
||||
-----------------
|
||||
|
||||
The PCI NUMA affinity code (mostly in ``hardware.py``) will need to be modified
|
||||
to limit the PCI devices considered to just those included in the allocation
|
||||
candidate summary. Also at the same time, this code should provide information
|
||||
to the scheduler about which allocation candidate is valid from affinity
|
||||
perspective.
|
||||
|
||||
To enable this the allocation candidates will be added to the ``HostState``
|
||||
object of the filter scheduler. The ``NUMATopologyFilter`` will then need to
|
||||
pass the allocation candidates to the hardware.py functions which will need to
|
||||
remove any allocation candidates from that list that do not fulfill the NUMA
|
||||
requirements. The filter should then pop any invalid allocation candidates
|
||||
from the ``HostState`` object. At the end of the scheduling process, the filter
|
||||
scheduler will have to reconstruct the host allocation candidate set from the
|
||||
``HostState`` object.
|
||||
|
||||
By extending the ``HostState`` object with the allocation candidate we will
|
||||
enable the filters to filter not just by the host but optionally by the
|
||||
allocation candidates of the host without altering the filter API therefore
|
||||
maintaining compatibility with external filters.
|
||||
|
||||
PCI tracker
|
||||
-----------
|
||||
|
||||
The PCI tracker will have to be enhanced to support allocation aware claims.
|
||||
To do this we will need to extend the ``PciDevicePool`` object to have a unique
|
||||
identifier that can be correlated by the resource tracker to the RP in
|
||||
Placement. The suggested value is the PCI address. In the case of ``type-PF``
|
||||
and ``type-PCI`` the PCI address for the allocation will be the PCI address of
|
||||
the device to claim. In the case of ``type-VF`` it will be the address of the
|
||||
parent device.
|
||||
|
||||
Both the instance claim and the move claim need to be extended similarly.
|
||||
|
||||
|
||||
VM lifecycle operations
|
||||
-----------------------
|
||||
|
||||
The initial scheduling is very similar to the later scheduling done due to
|
||||
move operations. So, the existing implementation can be reused. Also, the
|
||||
current logic that switches the source node Placement allocation to be held by
|
||||
the migration UUID can be reused.
|
||||
|
||||
Live migration is not supported with PCI alias-based PCI devices and this will
|
||||
not be changed by the current spec.
|
||||
|
||||
Attaching and detaching PCI devices are only supported via Neutron SR-IOV ports
|
||||
and that is out of the scope of this spec.
|
||||
|
||||
|
||||
Neutron SR-IOV ports (out of scope)
|
||||
-----------------------------------
|
||||
|
||||
This is out of scope in the current spec. But certain aspects of the problem
|
||||
are already known and therefore listed here.
|
||||
|
||||
There are a list of Neutron port ``vnic_type`` (e.g. ``direct``,
|
||||
``direct-physical``,etc) where the port needs to be backed by VF or PF PCI
|
||||
devices.
|
||||
|
||||
In the simpler case when a port only requires a PCI device but does
|
||||
not require any other resources (e.g. bandwidth) then Nova needs to create
|
||||
Placement request groups for each Neutron port with the already proposed
|
||||
prefilter. See `Scheduling`_ for more details. In this case, neither the
|
||||
name of the resource class nor the vendor ID, product ID pair is known at
|
||||
scheduling time (compared to the PCI alias case) therefore the prefilter does
|
||||
not know what resource class needs to be requested in the Placement request
|
||||
group.
|
||||
|
||||
To resolve this, PCI devices that are intended to be used for Neutron-based
|
||||
SR-IOV should should not use the ``resource_class`` tag in the
|
||||
``[pci]device_spec``. Instead Nova will use standard resource classes to
|
||||
model these resource.
|
||||
|
||||
Today nova allows consuming type-PCI or type-VF for ``direct`` ports. This
|
||||
is mostly there due to historical reasons and it should be cleaned up. A
|
||||
better device categorization is suggested:
|
||||
|
||||
* A device in the ``device_spec`` will be consumable only via PCI alias
|
||||
if it does not have ``physical_network`` tag attached.
|
||||
|
||||
* A device that has ``physical_network`` tag attached will be considered a
|
||||
network device and it will be modelled as ``PCI_NETDEV`` resource.
|
||||
|
||||
* A device that has ``physical_network`` tag and also has the capability to
|
||||
provide VFs will have a trait ``HW_NIC_SRIOV`` but still use the
|
||||
``PCI_NETDEV`` resource class.
|
||||
|
||||
* A device that has ``physical_network`` tag and is a VF will be modelled
|
||||
as ``SRIOV_NET_VF`` resource.
|
||||
|
||||
This way every Neutron ``vnic_type`` can be mapped to one single resource
|
||||
class by Nova. The following ``vnic_type`` -> resource class mapping is
|
||||
suggested:
|
||||
|
||||
* ``direct``, ``macvtap``, ``virtio-forwarder``, ``remote-managed`` ->
|
||||
``SRIOV_NET_VF``
|
||||
* ``direct-physical`` -> ``PCI_NETDEV``
|
||||
* ``vdpa`` -> ``VDPA_NETDEV``
|
||||
|
||||
Nova will use these resource classes to report device inventories to
|
||||
Placement. Then the prefilter can translate the ``vnic_type`` of the ports to
|
||||
request the specific resource class during scheduling.
|
||||
|
||||
Another specialty of Neutron-based SR-IOV is that the devices listed in the
|
||||
``device_spec`` always have a ``physical_network`` tag.
|
||||
This information needs to be reported as a trait to the PF RP in Placement.
|
||||
Also, the port's requested physnet needs to be included in the Placement
|
||||
request group by the prefilter.
|
||||
|
||||
There is a more complex case when the Neutron port not only requests a PCI
|
||||
device but also requests additional resources (e.g. bandwidth) via the port
|
||||
``resource_request`` attribute. In this case, Nova already generates Placement
|
||||
request groups from the ``resource_request`` and as in the simple case will
|
||||
generate a request group from the PCI request. The resource request
|
||||
of these groups of a neutron port needs to be correlated to ensure that a port
|
||||
gets the PCI device and the bandwidth from the same physical device. However
|
||||
today the bandwidth is modeled under the Neutron RP subtree while PCI devices
|
||||
will be modeled right under the root RP. So the two RPs to allocate from are
|
||||
not within the same subtree. (Note that Placement always fulfills a named
|
||||
request group from a single RP but allows correlating such request groups
|
||||
within the same subtree.) We have multiple options here:
|
||||
|
||||
* Create a scheduler filter that removes allocation candidates where these
|
||||
request groups are fulfilled from different physical devices
|
||||
|
||||
* Report the bandwidth and the PCI device resource on the same RP. This breaks
|
||||
the clear ownership of a single RP as the bandwidth is reported by the
|
||||
neutron agent while the PCI device is reported by Nova.
|
||||
|
||||
* Move the two RPs (bandwidth and PCI dev) into the same subtree. This
|
||||
needs an agreement between Nova and Neutron devs where to move the RPs and
|
||||
needs an extra reshape to implement the move.
|
||||
|
||||
* Enhance Placement to allow sharing of resources between RPs within the same
|
||||
RP tree. By that, we could make the bandwidth RP a sharing RP that shares
|
||||
resources with the PCI device RP representing the physical device.
|
||||
|
||||
Based on the selected solution either:
|
||||
|
||||
* Neutron requests the specific resource class for the SRIOV
|
||||
port via the port ``resource_request`` field
|
||||
|
||||
* Nova can include these resources to the request when the
|
||||
``InstancePCIRequest`` objects are created based on the requested ports.
|
||||
|
||||
Alternatives
|
||||
------------
|
||||
|
||||
* We could keep using the legacy tracking with all its good and bad properties.
|
||||
|
||||
* We could track each PCI device record as a separate RP.
|
||||
This would result in each VF having its own RP allowing each VF to have
|
||||
different traits. This is not proposed as it will significantly increase the
|
||||
possible permutations of allocation candidates per host.
|
||||
|
||||
* We could keep supporting the dynamic PF or VF consumption in Placement but
|
||||
it is deemed more complex than useful. We will keep supporting it via the
|
||||
legacy code path but the new code path will not support it.
|
||||
|
||||
* We could model each PCI device under a NUMA node.
|
||||
This can be done in the future by moving the RP under a NUMA node RP instead
|
||||
of the compute node RP but it is declared out of the scope of this initial
|
||||
spec.
|
||||
|
||||
|
||||
Data model impact
|
||||
-----------------
|
||||
|
||||
``InstancePCIRequest`` object will be extended to include the required and
|
||||
forbidden traits and the resource class requested via the PCI alias in the
|
||||
flavor and defined in the PCI alias configuration.
|
||||
|
||||
``PciDevicePool`` object will be extended to store PCI address information so
|
||||
that the PCI device allocated in Placement can be correlated to the PCI device
|
||||
to be claimed by the PCI tracker.
|
||||
|
||||
REST API impact
|
||||
---------------
|
||||
|
||||
None
|
||||
|
||||
Security impact
|
||||
---------------
|
||||
|
||||
None
|
||||
|
||||
Notifications impact
|
||||
--------------------
|
||||
|
||||
None
|
||||
|
||||
Other end user impact
|
||||
---------------------
|
||||
|
||||
None
|
||||
|
||||
Performance Impact
|
||||
------------------
|
||||
|
||||
In general, this is expected to improve the scheduling performance but
|
||||
should have no runtime performance impact on guests.
|
||||
|
||||
The introduction of a new prefilter will make the computation of the placement
|
||||
query slightly longer and the resulting execution time may increase for
|
||||
instances with PCI requests but should have no effect for instances without
|
||||
PCI requests. This added complexity is expected to be offset by the removal of
|
||||
the requirement to enable the ``PciPassthroughFilter`` scheduler filter
|
||||
eventually. As a result of the offloading of the filtering to Placement and the
|
||||
removal of reschedules due to racing for the last PCI device on a host, the
|
||||
overall performance is expected to improve.
|
||||
|
||||
Other deployer impact
|
||||
---------------------
|
||||
|
||||
To utilize the new feature the operator will have to define two new config
|
||||
options. One to enable the placement prefilter and a second to enable the
|
||||
reporting of the PCI devices to Placement.
|
||||
|
||||
Developer impact
|
||||
----------------
|
||||
|
||||
Drivers, other than the libvirt virt driver, need to be adapted to use the new
|
||||
Placement based PCI device tracking.
|
||||
|
||||
Upgrade impact
|
||||
--------------
|
||||
|
||||
The new Placement based PCI tracking will be disabled by default. Deployments
|
||||
already using PCI devices can freely upgrade to the new Nova version without
|
||||
any impact. At this state the PCI device management will be done by the
|
||||
``PciPassthroughFilter`` in the scheduler and the PCI claim in the PCI device
|
||||
tracker in the compute service same as in the previous version of Nova.
|
||||
Then after the upgrade the new PCI device tracking can be enabled in two
|
||||
phases.
|
||||
|
||||
First the PCI inventory reporting needs to be enabled by
|
||||
``[pci]report_to_placement`` on each compute host. During the startup of the
|
||||
nova-compute service with ``[pci]report_to_placement = True`` config the
|
||||
service will do the reshape of the provider tree and start reporting PCI device
|
||||
inventory to Placement. Nova compute will also heal the PCI allocation of the
|
||||
existing instances in Placement. This healing will be done for new
|
||||
instances with PCI requests until a future release where the prefilter enabled
|
||||
by default. This is needed to keep the resource usage in sync in Placement
|
||||
even if the instance scheduling is done without the prefilter requesting
|
||||
PCI allocations in Placement.
|
||||
|
||||
.. note::
|
||||
|
||||
Even after we make the prefilter enabled by default in a future release the
|
||||
prefilter still need to be kept configurable as we don't know when the hyperv
|
||||
virt driver will implement PCI tracking in Placement.
|
||||
|
||||
.. note::
|
||||
|
||||
Operators are encouraged to take the opportunity to rename the
|
||||
``[pci]passthrough_whitelist`` config option to the new ``[pci]device_spec``
|
||||
option. The syntax of the two options are the same.
|
||||
|
||||
.. note::
|
||||
|
||||
The ``devname`` tag is not supported in the ``[pci]device_spec`` and in the
|
||||
``[pci]passthrough_whitelist`` any more if ``[pci]report_to_placement`` is
|
||||
enabled. We suggest to use the ``address`` tag instead.
|
||||
|
||||
.. note::
|
||||
|
||||
If the deployment is configured to rely on the dynamic dependent device
|
||||
behavior, i.e. both the PF and its children VFs are matching the
|
||||
``device_spec`` then reconfiguration will be needed as the new code patch
|
||||
will not support this and the nova-compute service will reject to start with
|
||||
such configuration. To do the reconfiguration the deployer needs to look at
|
||||
the current allocation of the PCI devices on each compute node:
|
||||
|
||||
* if neither the PF nor any of its children VFs are allocated then the
|
||||
deployer can decide which device(s) kept in the ``device_spec``.
|
||||
|
||||
* if the PF is already allocated then the PF needs to be kept in the
|
||||
``device_spec`` but all children VFs has to be removed.
|
||||
|
||||
* if any of the children VF device is allocated then the parent PF needs to
|
||||
be removed from the ``device_spec`` and at least the currently allocated
|
||||
VFs needs to be kept in the config, while other non allocated children VFs
|
||||
can be kept or removed from the ``device_spec`` at will.
|
||||
|
||||
.. note::
|
||||
|
||||
Once ``[pci]report_to_placement`` is enabled for a compute host it cannot be
|
||||
disabled any more.
|
||||
|
||||
Second, after every compute has been configured to report PCI inventories to
|
||||
Placement the scheduling prefilter needs to be enabled in the nova-scheduler
|
||||
configuration via the ``[scheduler]pci_prefilter`` configuration option.
|
||||
|
||||
|
||||
Implementation
|
||||
==============
|
||||
|
||||
Assignee(s)
|
||||
-----------
|
||||
|
||||
|
||||
Primary assignee:
|
||||
balazs-gibizer
|
||||
|
||||
|
||||
Feature Liaison
|
||||
---------------
|
||||
|
||||
|
||||
Feature liaison:
|
||||
sean-k-mooney
|
||||
|
||||
|
||||
Work Items
|
||||
----------
|
||||
* rename PCI ``passthrough_whitelist`` to ``device_spec``
|
||||
* support for adding a resource class and traits to ``device_spec``
|
||||
* introduce ``[pci]report_in_placement``
|
||||
* reject dependent devices config and ``devname`` config
|
||||
* PCI reshape and allocation healing for existing instances
|
||||
* support for adding resource class and required and forbidden traits to PCI
|
||||
alias
|
||||
* prefilter
|
||||
* extension of ``HostState`` object with an allocations candidate list
|
||||
* extension of scheduler to populate ``HostState`` object with candidates and
|
||||
then reconstruct the candidate list after filtering.
|
||||
* extension of ``hardware.py`` to consider allocation candidates when filtering
|
||||
for NUMA affinity.
|
||||
* extension of PCI manager claiming to be allocation aware.
|
||||
|
||||
Dependencies
|
||||
============
|
||||
|
||||
The unified limits feature exists in an opt-in, experimental state and will
|
||||
allow defining limits for the new PCI resources if enabled.
|
||||
|
||||
|
||||
Testing
|
||||
=======
|
||||
|
||||
As this is a PCI passthrough related feature it cannot be tested in upstream
|
||||
tempest. Testing will be primarily done via the extensive unit and functional
|
||||
test suites that exists for instances with PCI devices and NUMA topology in the
|
||||
libvirt functional tests.
|
||||
|
||||
|
||||
Documentation Impact
|
||||
====================
|
||||
|
||||
The PCI passthrough doc will have to be rewritten to document the new
|
||||
``resource_class`` and ``trait`` tags for the PCI ``device_spec`` and
|
||||
PCI alias.
|
||||
|
||||
|
||||
References
|
||||
==========
|
||||
|
||||
* _`CPU resource tracking spec`: https://specs.openstack.org/openstack/nova-specs/specs/train/implemented/cpu-resources.html
|
||||
* _`Unified Limits Integration in Nova`: https://specs.openstack.org/openstack/nova-specs/specs/ussuri/approved/unified-limits-nova.html
|
||||
* _`Support virtual GPU resources`: https://specs.openstack.org/openstack/nova-specs/specs/queens/implemented/add-support-for-vgpu.html
|
||||
|
||||
History
|
||||
=======
|
||||
|
||||
.. list-table:: Revisions
|
||||
:header-rows: 1
|
||||
|
||||
* - Release Name
|
||||
- Description
|
||||
* - Xena
|
||||
- Introduced
|
||||
* - Zed
|
||||
- Extended and re-proposed
|
Loading…