Merge "Improve the help text for hyperv options (3)"
This commit is contained in:
commit
24abc340a8
@ -285,34 +285,129 @@ Related options:
|
||||
wait_soft_reboot_seconds_opt = cfg.IntOpt('wait_soft_reboot_seconds',
|
||||
default=60,
|
||||
help="""
|
||||
Number of seconds to wait for instance to shut down after
|
||||
soft reboot request is made. We fall back to hard reboot
|
||||
if instance does not shutdown within this window.
|
||||
Wait soft reboot seconds
|
||||
|
||||
Number of seconds to wait for instance to shut down after soft
|
||||
reboot request is made. We fall back to hard reboot if instance
|
||||
does not shutdown within this window.
|
||||
|
||||
Possible values:
|
||||
|
||||
* Time in seconds (Default: 60).
|
||||
|
||||
Services which consume this:
|
||||
|
||||
* nova-compute
|
||||
|
||||
Related options:
|
||||
|
||||
* None
|
||||
""")
|
||||
|
||||
config_drive_cdrom_opt = cfg.BoolOpt('config_drive_cdrom',
|
||||
default=False,
|
||||
help="""
|
||||
Attaches the Config Drive image as a cdrom drive
|
||||
instead of a disk drive
|
||||
Configuration drive cdrom
|
||||
|
||||
OpenStack can be configured to write instance metadata to
|
||||
a configuration drive, which is then attached to the
|
||||
instance before it boots. The configuration drive can be
|
||||
attached as a disk drive (default) or as a CD drive.
|
||||
|
||||
Possible values:
|
||||
|
||||
* True: Attach the configuration drive image as a CD drive.
|
||||
* False: Attach the configuration drive image as a disk drive (Default).
|
||||
|
||||
Services which consume this:
|
||||
|
||||
* nova-compute
|
||||
|
||||
Related options:
|
||||
|
||||
* This option is meaningful with force_config_drive option set to 'True'
|
||||
or when the REST API call to create an instance will have
|
||||
'--config-drive=True' flag.
|
||||
* config_drive_format option must be set to 'iso9660' in order to use
|
||||
CD drive as the configuration drive image.
|
||||
* To use configuration drive with Hyper-V, you must set the
|
||||
mkisofs_cmd value to the full path to an mkisofs.exe installation.
|
||||
Additionally, you must set the qemu_img_cmd value to the full path
|
||||
to an qemu-img command installation.
|
||||
* You can configure the Compute service to always create a configuration
|
||||
drive by setting the force_config_drive option to 'True'.
|
||||
""")
|
||||
|
||||
config_drive_inject_password_opt = cfg.BoolOpt('config_drive_inject_password',
|
||||
default=False,
|
||||
help="""
|
||||
Sets the admin password in the config drive image
|
||||
Configuration drive inject password
|
||||
|
||||
Enables setting the admin password in the configuration drive image.
|
||||
|
||||
Possible values:
|
||||
|
||||
* True: Enables the feature.
|
||||
* False: Disables the feature (Default).
|
||||
|
||||
Services which consume this:
|
||||
|
||||
* nova-compute
|
||||
|
||||
Related options:
|
||||
|
||||
* This option is meaningful when used with other options that enable
|
||||
configuration drive usage with Hyper-V, such as force_config_drive.
|
||||
* Currently, the only accepted config_drive_format is 'iso9660'.
|
||||
""")
|
||||
|
||||
volume_attach_retry_count_opt = cfg.IntOpt('volume_attach_retry_count',
|
||||
default=10,
|
||||
help="""
|
||||
The number of times to retry to attach a volume
|
||||
Volume attach retry count
|
||||
|
||||
The number of times to retry to attach a volume. This option is used
|
||||
to avoid incorrectly returned no data when the system is under load.
|
||||
Volume attachment is retried until success or the given retry count
|
||||
is reached. To prepare the Hyper-V node to be able to attach to
|
||||
volumes provided by cinder you must first make sure the Windows iSCSI
|
||||
initiator service is running and started automatically.
|
||||
|
||||
Possible values:
|
||||
|
||||
* Positive integer values (Default: 10).
|
||||
|
||||
Services which consume this:
|
||||
|
||||
* nova-compute
|
||||
|
||||
Related options:
|
||||
|
||||
* Time interval between attachment attempts is declared with
|
||||
volume_attach_retry_interval option.
|
||||
""")
|
||||
|
||||
volume_attach_retry_interval_opt = cfg.IntOpt('volume_attach_retry_interval',
|
||||
default=5,
|
||||
help="""
|
||||
Interval between volume attachment attempts, in seconds
|
||||
Volume attach retry interval
|
||||
|
||||
Interval between volume attachment attempts, in seconds.
|
||||
|
||||
Possible values:
|
||||
|
||||
* Time in seconds (Default: 5).
|
||||
|
||||
Services which consume this:
|
||||
|
||||
* nova-compute
|
||||
|
||||
Related options:
|
||||
|
||||
* This options is meaningful when volume_attach_retry_count
|
||||
is greater than 1.
|
||||
* The retry loop runs with volume_attach_retry_count and
|
||||
volume_attach_retry_interval configuration options.
|
||||
""")
|
||||
|
||||
|
||||
|
Loading…
Reference in New Issue
Block a user