@ -26,11 +26,30 @@ from oslo_config import cfg
|
|||||||
|
|
||||||
consoleauth_topic_opt = cfg.StrOpt('consoleauth_topic',
|
consoleauth_topic_opt = cfg.StrOpt('consoleauth_topic',
|
||||||
default='consoleauth',
|
default='consoleauth',
|
||||||
help='The topic console auth proxy nodes listen on')
|
help="""
|
||||||
|
This option allows you to change the message topic used by nova-consoleauth
|
||||||
|
service when communicating via the AMQP server. Nova Console Authentication
|
||||||
|
server authenticates nova consoles. Users can then access their instances
|
||||||
|
through VNC clients. The Nova API service uses a message queue to
|
||||||
|
communicate with nova-consoleauth to get a VNC console.
|
||||||
|
|
||||||
|
Possible Values:
|
||||||
|
|
||||||
|
* 'consoleauth' (default) or Any string representing topic exchange name.
|
||||||
|
""")
|
||||||
|
|
||||||
console_token_ttl = cfg.IntOpt('console_token_ttl',
|
console_token_ttl = cfg.IntOpt('console_token_ttl',
|
||||||
default=600,
|
default=600,
|
||||||
help='How many seconds before deleting tokens')
|
help="""
|
||||||
|
This option indicates the lifetime of a console auth token. A console auth
|
||||||
|
token is used in authorizing console access for a user. Once the auth token
|
||||||
|
time to live count has elapsed, the token is considered expired. Expired
|
||||||
|
tokens are then deleted.
|
||||||
|
|
||||||
|
Possible values:
|
||||||
|
|
||||||
|
* Any positive integer. The default is 600.
|
||||||
|
""")
|
||||||
|
|
||||||
CONSOLEAUTH_OPTS = [consoleauth_topic_opt, console_token_ttl]
|
CONSOLEAUTH_OPTS = [consoleauth_topic_opt, console_token_ttl]
|
||||||
|
|
||||||
|