docs: Rework the PCI passthrough guides
Rewrite the document, making the following changes: - Remove use of bullet points in favour of more descriptive steps - Cross-reference various configuration options - Emphasise that ``[pci] alias`` must be set on both controller and compute node - Style nits, such as fixing the header style Change-Id: I2ac7df7d235f0af25f5a99bc8f6abddbae2cb3af Signed-off-by: Stephen Finucane <sfinucan@redhat.com>
This commit is contained in:
parent
38c774a8e0
commit
d5259abfe1
@ -22,48 +22,51 @@ assigned to only one guest and cannot be shared.
|
||||
|
||||
**Limitations**
|
||||
|
||||
* Attaching SR-IOV ports to existing servers is not currently supported, see
|
||||
`bug 1708433 <https://bugs.launchpad.net/nova/+bug/1708433>`_ for details.
|
||||
* Attaching SR-IOV ports to existing servers is not currently supported.
|
||||
This is now rejected by the API but previously it fail later in the
|
||||
process. See `bug 1708433 <https://bugs.launchpad.net/nova/+bug/1708433>`_
|
||||
for details.
|
||||
* Cold migration (resize) of servers with SR-IOV devices attached was not
|
||||
supported until the 14.0.0 Newton release, see
|
||||
`bug 1512800 <https://bugs.launchpad.net/nova/+bug/1512880>`_ for details.
|
||||
|
||||
To enable PCI passthrough, follow the steps below:
|
||||
|
||||
#. Configure nova-scheduler (Controller)
|
||||
|
||||
#. Configure nova-api (Controller)**
|
||||
|
||||
#. Configure a flavor (Controller)
|
||||
|
||||
#. Enable PCI passthrough (Compute)
|
||||
|
||||
#. Configure PCI devices in nova-compute (Compute)
|
||||
To enable PCI passthrough, follow the steps below.
|
||||
|
||||
.. note::
|
||||
|
||||
The PCI device with address ``0000:41:00.0`` is used as an example. This
|
||||
will differ between environments.
|
||||
The PCI device with address ``0000:41:00.0``, the vendor ID of ``8086`` and
|
||||
the product ID of ``154d`` is used as an example. This will differ between
|
||||
environments.
|
||||
|
||||
Configure nova-scheduler (Controller)
|
||||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||
|
||||
#. Configure ``nova-scheduler`` as specified in :neutron-doc:`Configure
|
||||
nova-scheduler
|
||||
<admin/config-sriov.html#configure-nova-scheduler-controller>`.
|
||||
Configure ``nova-scheduler`` (Controller)
|
||||
-----------------------------------------
|
||||
|
||||
#. Restart the ``nova-scheduler`` service.
|
||||
The :program:`nova-scheduler` service must be configured to enable the
|
||||
``PciPassthroughFilter``. To do this, add this filter to the list of filters
|
||||
specified in :oslo.config:option:`filter_scheduler.enabled_filters` and set
|
||||
:oslo.config:option:`filter_scheduler.available_filters` to the default of
|
||||
``nova.scheduler.filters.all_filters``. For example:
|
||||
|
||||
Configure nova-api (Controller)
|
||||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||
.. code-block:: ini
|
||||
|
||||
#. Specify the PCI alias for the device.
|
||||
[filter_scheduler]
|
||||
enabled_filters = ...,PciPassthroughFilter
|
||||
available_filters = nova.scheduler.filters.all_filters
|
||||
|
||||
Configure a PCI alias ``a1`` to request a PCI device with a ``vendor_id`` of
|
||||
``0x8086`` and a ``product_id`` of ``0x154d``. The ``vendor_id`` and
|
||||
``product_id`` correspond the PCI device with address ``0000:41:00.0``.
|
||||
Once done, restart the :program:`nova-scheduler` service.
|
||||
|
||||
Edit ``/etc/nova/nova.conf``:
|
||||
|
||||
.. _pci-passthrough-alias:
|
||||
|
||||
Configure ``nova-api`` (Controller)
|
||||
-----------------------------------
|
||||
|
||||
PCI devices are requested through flavor extra specs, specifically via the
|
||||
``pci_passthrough:alias`` flavor extra spec. However, the aliases themselves
|
||||
must be configured. This done via the :oslo.config:option:`pci.alias`
|
||||
configuration option. For example, to configure a PCI alias ``a1`` to request
|
||||
a PCI device with a vendor ID of ``0x8086`` and a product ID of ``0x154d``:
|
||||
|
||||
.. code-block:: ini
|
||||
|
||||
@ -72,33 +75,45 @@ Configure nova-api (Controller)
|
||||
|
||||
Refer to :oslo.config:option:`pci.alias` for syntax information.
|
||||
|
||||
#. Restart the ``nova-api`` service.
|
||||
Once configured, restart the :program:`nova-api` service.
|
||||
|
||||
Configure a flavor (Controller)
|
||||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||
.. important::
|
||||
|
||||
Configure a flavor to request two PCI devices, each with ``vendor_id`` of
|
||||
``0x8086`` and ``product_id`` of ``0x154d``:
|
||||
This option must also be configured on compute nodes. This is discussed later
|
||||
in this document.
|
||||
|
||||
|
||||
Configure a flavor (API)
|
||||
------------------------
|
||||
|
||||
Once the alias has been configured, it can be used for an flavor extra spec.
|
||||
For example, to request two of the PCI devices referenced by alias ``a1``, run:
|
||||
|
||||
.. code-block:: console
|
||||
|
||||
# openstack flavor set m1.large --property "pci_passthrough:alias"="a1:2"
|
||||
$ openstack flavor set m1.large --property "pci_passthrough:alias"="a1:2"
|
||||
|
||||
For more information about the syntax for ``pci_passthrough:alias``, refer to
|
||||
:ref:`Flavors <extra-spec-pci-passthrough>`.
|
||||
|
||||
Enable PCI passthrough (Compute)
|
||||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||
|
||||
Enable VT-d and IOMMU. For more information, refer to steps one and two in
|
||||
:neutron-doc:`Create Virtual Functions
|
||||
<admin/config-sriov.html#create-virtual-functions-compute>`.
|
||||
Configure host (Compute)
|
||||
------------------------
|
||||
|
||||
For Hyper-V compute nodes, the requirements are as follows:
|
||||
To enable PCI passthrough on an x86, Linux-based compute node, the following
|
||||
are required:
|
||||
|
||||
* Windows 10 or Windows / Hyper-V Server 2016 or newer.
|
||||
* VT-d and SR-IOV enabled on the host.
|
||||
* Assignable PCI devices.
|
||||
* VT-d enabled in the BIOS
|
||||
* IOMMU enabled on the host OS, by adding the ``intel_iommu=on`` or
|
||||
``amd_iommu=on`` parameter to the kernel parameters
|
||||
* Assignable PCIe devices
|
||||
|
||||
To enable PCI passthrough on a Hyper-V compute node, the following are
|
||||
required:
|
||||
|
||||
* Windows 10 or Windows / Hyper-V Server 2016 or newer
|
||||
* VT-d enabled on the host
|
||||
* Assignable PCI devices
|
||||
|
||||
In order to check the requirements above and if there are any assignable PCI
|
||||
devices, run the following Powershell commands:
|
||||
@ -115,40 +130,38 @@ passthrough`__.
|
||||
|
||||
.. __: https://devblogs.microsoft.com/scripting/passing-through-devices-to-hyper-v-vms-by-using-discrete-device-assignment/
|
||||
|
||||
Configure PCI devices (Compute)
|
||||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||
|
||||
#. Configure ``nova-compute`` to allow the PCI device to pass through to
|
||||
VMs. Edit ``/etc/nova/nova.conf``:
|
||||
Configure ``nova-compute`` (Compute)
|
||||
------------------------------------
|
||||
|
||||
Once PCI passthrough has been configured for the host, :program:`nova-compute`
|
||||
must be configured to allow the PCI device to pass through to VMs. This is done
|
||||
using the :oslo.config:option:`pci.passthrough_whitelist` option. For example,
|
||||
to enable passthrough of a specific device using its address:
|
||||
|
||||
.. code-block:: ini
|
||||
|
||||
[pci]
|
||||
passthrough_whitelist = { "address": "0000:41:00.0" }
|
||||
|
||||
Alternatively specify multiple PCI devices using whitelisting:
|
||||
Refer to :oslo.config:option:`pci.passthrough_whitelist` for syntax information.
|
||||
|
||||
Alternatively, to enable passthrough of all devices with the same product and
|
||||
vendor ID:
|
||||
|
||||
.. code-block:: ini
|
||||
|
||||
[pci]
|
||||
passthrough_whitelist = { "vendor_id": "8086", "product_id": "10fb" }
|
||||
passthrough_whitelist = { "vendor_id": "8086", "product_id": "154d" }
|
||||
|
||||
All PCI devices matching the ``vendor_id`` and ``product_id`` are added to
|
||||
the pool of PCI devices available for passthrough to VMs.
|
||||
If using vendor and product IDs, all PCI devices matching the ``vendor_id`` and
|
||||
``product_id`` are added to the pool of PCI devices available for passthrough
|
||||
to VMs.
|
||||
|
||||
Refer to :oslo.config:option:`pci.passthrough_whitelist` for syntax
|
||||
information.
|
||||
|
||||
#. Specify the PCI alias for the device.
|
||||
|
||||
From the Newton release, to resize guest with PCI device, configure the PCI
|
||||
alias on the compute node as well.
|
||||
|
||||
Configure a PCI alias ``a1`` to request a PCI device with a ``vendor_id`` of
|
||||
``0x8086`` and a ``product_id`` of ``0x154d``. The ``vendor_id`` and
|
||||
``product_id`` correspond the PCI device with address ``0000:41:00.0``.
|
||||
|
||||
Edit ``/etc/nova/nova.conf``:
|
||||
In addition, it is necessary to configure the :oslo.config:option:`pci.alias`
|
||||
option on the compute node too. This is required to allow resizes of guests
|
||||
with PCI devices. This should be identical to the alias configured
|
||||
:ref:`previously <pci-passthrough-alias>`. For example:
|
||||
|
||||
.. code-block:: ini
|
||||
|
||||
@ -157,14 +170,14 @@ Configure PCI devices (Compute)
|
||||
|
||||
Refer to :oslo.config:option:`pci.alias` for syntax information.
|
||||
|
||||
#. Restart the ``nova-compute`` service.
|
||||
Once configured, restart the :program:`nova-compute` service.
|
||||
|
||||
|
||||
Create instances with PCI passthrough devices
|
||||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||
---------------------------------------------
|
||||
|
||||
The ``nova-scheduler`` selects a destination host that has PCI devices
|
||||
available with the specified ``vendor_id`` and ``product_id`` that matches the
|
||||
``alias`` from the flavor.
|
||||
The :program:`nova-scheduler` service selects a destination host that has PCI
|
||||
devices available that match the ``alias`` specified in the flavor.
|
||||
|
||||
.. code-block:: console
|
||||
|
||||
|
Loading…