octavia-dashboard/octavia_dashboard/static/dashboard/project/lbaasv2/workflow/listener/listener.help.html

65 lines
1.9 KiB
HTML

<p translate>
Each port that listens for traffic on a particular load balancer is configured separately and
tied to the load balancer. Multiple listeners can be associated with the same load balancer but
each must use a unique port.
</p>
<p>
<strong translate>Protocol:</strong>
<translate>
The protocol for which the front end listens. The TERMINATED_HTTPS protocol is only available if
the key-manager service is enabled and you have authority to list certificate containers and
secrets.
</translate>
</p>
<p>
<strong translate>Port:</strong>
<translate>
The port on which the front end listens. Must be an integer from 1 to 65535.
</translate>
</p>
<p>
<strong translate>Connection Limit:</strong>
<translate>
The maximum number of connections permitted for this listener.
Default value is -1 which represents infinite connections.
</translate>
</p>
<p>
<strong translate>Default Pool ID:</strong>
<translate>
The ID of the pool used by the listener if no L7 policies match.
</translate>
</p>
<p>
<strong translate>Insert Headers:</strong>
<translate>
Additional headers insertion into HTTP header,
only "X-Forwarded-For" and "X-Forwarded-Port" are supported.
</translate>
</p>
<p>
<strong translate>Client Data Timeout:</strong>
<translate>
Frontend client inactivity timeout in milliseconds. Default: 50000.
</translate>
</p>
<p>
<strong translate>TCP Inspect Timeout:</strong>
<translate>
Time, in milliseconds, to wait for additional TCP packets for content
inspection. Default: 0.
</translate>
</p>
<p>
<strong translate>Member Connect Timeout:</strong>
<translate>
Backend member connection timeout in milliseconds. Default: 5000.
</translate>
</p>
<p>
<strong translate>Member Data Timeout:</strong>
<translate>
Backend member inactivity timeout in milliseconds. Default: 50000.
</translate>
</p>