Browse Source

Fix controller worker graceful shutdown

Fix an issue that prevents graceful shutdown of controller workers.

cotyledon.Service.terminate function is by definition the graceful
termination function and doesn't have any 'graceful' optional boolean
argument (https://cotyledon.readthedocs.io/en/latest/api.html).

Because of this error, message_listener.wait() was never called in the
consumers' termination functions, so flows could be interrupted before
completion and could leave resources such as load balancer in a
PENDING_* provisioning state.

By default cotyledon.Service terminates the server after a timeout if
the worker could not shutdown itself gracefully. The default value
for the timeout is 300 seconds (set in devstack plugin) and can be
overriden using the graceful_shutdown_timeout setting in octavia.conf
The default value will be updated to a lower value when work on
persistant taskflow will be merged.

Story: 2006603
Task: 36770

Conflicts:
	devstack/plugin.sh

Change-Id: I3f776bd018246897c9a889699a2d0ecbbfbb7098
(cherry picked from commit 215c4c2284209ff46dc62f7cc04432cb2c9bf39e)
(cherry picked from commit 0fc1ea4789eaf743e04db31d366b64a34172df15)
(cherry picked from commit 6fe5df6fd8b80e3022120f2bd74098a8e71152f7)
changes/79/695379/1
Gregory Thiemonge 4 months ago
parent
commit
1f61b1f090
7 changed files with 24 additions and 17 deletions
  1. +4
    -0
      devstack/plugin.sh
  2. +1
    -0
      doc/source/configuration/configref.rst
  3. +3
    -0
      etc/octavia.conf
  4. +5
    -5
      octavia/controller/queue/consumer.py
  5. +0
    -11
      octavia/tests/unit/controller/queue/test_consumer.py
  6. +9
    -0
      releasenotes/notes/fix-worker-graceful-shutdown-c44b6797637aa1b3.yaml
  7. +2
    -1
      tox.ini

+ 4
- 0
devstack/plugin.sh View File

@@ -307,6 +307,10 @@ function octavia_configure {
fi
fi

# set default graceful_shutdown_timeout to 300 sec (5 minutes)
# TODO(gthiemonge) update this value after persistant taskflow commits are
# merged
iniset $OCTAVIA_CONF DEFAULT graceful_shutdown_timeout 300
}

function create_mgmt_network_interface {

+ 1
- 0
doc/source/configuration/configref.rst View File

@@ -26,3 +26,4 @@ Octavia Configuration Options
oslo.db
oslo.log
oslo.messaging
cotyledon

+ 3
- 0
etc/octavia.conf View File

@@ -16,6 +16,9 @@
# transport_url = rabbit://<user>:<pass>@server01,<user>:<pass>@server02/<vhost>
# transport_url =

# How long in seconds to wait for octavia worker to exit before killing them.
# graceful_shutdown_timeout = 60

[api_settings]
# bind_host = 127.0.0.1
# bind_port = 9876

+ 5
- 5
octavia/controller/queue/consumer.py View File

@@ -46,14 +46,14 @@ class ConsumerService(cotyledon.Service):
)
self.message_listener.start()

def terminate(self, graceful=False):
def terminate(self):
if self.message_listener:
LOG.info('Stopping consumer...')
self.message_listener.stop()
if graceful:
LOG.info('Consumer successfully stopped. Waiting for final '
'messages to be processed...')
self.message_listener.wait()
LOG.info('Consumer successfully stopped. Waiting for final '
'messages to be processed...')
self.message_listener.wait()
if self.endpoints:
LOG.info('Shutting down endpoint worker executors...')
for e in self.endpoints:

+ 0
- 11
octavia/tests/unit/controller/queue/test_consumer.py View File

@@ -58,15 +58,4 @@ class TestConsumer(base.TestRpc):
cons.run()
cons.terminate()
mock_rpc_server_rv.stop.assert_called_once_with()
self.assertFalse(mock_rpc_server_rv.wait.called)

@mock.patch.object(messaging, 'get_rpc_server')
def test_consumer_graceful_terminate(self, mock_rpc_server):
mock_rpc_server_rv = mock.Mock()
mock_rpc_server.return_value = mock_rpc_server_rv

cons = consumer.ConsumerService(1, self.conf)
cons.run()
cons.terminate(graceful=True)
mock_rpc_server_rv.stop.assert_called_once_with()
mock_rpc_server_rv.wait.assert_called_once_with()

+ 9
- 0
releasenotes/notes/fix-worker-graceful-shutdown-c44b6797637aa1b3.yaml View File

@@ -0,0 +1,9 @@
---
fixes:
- |
Fix a bug that could interrupt resource creation when performing a graceful
shutdown of the controller worker and leave resources in a
PENDING_CREATE/PENDING_UPDATE/PENDING_DELETE provisioning status. If the
duration of an Octavia flow is greater than the 'graceful_shutdown_timeout'
configuration value, stopping the Octavia worker can still interrupt the
creation of resources.

+ 2
- 1
tox.ini View File

@@ -103,7 +103,8 @@ commands =
--namespace oslo.db \
--namespace oslo.log \
--namespace oslo.messaging \
--namespace keystonemiddleware.auth_token
--namespace keystonemiddleware.auth_token \
--namespace cotyledon

[testenv:genpolicy]
whitelist_externals = mkdir

Loading…