2897b340f7
Currently with Octavia, if the user specifies a health monitor of type "PING" we are still using a TCP connect to check for health. This patch fixes that to actually ping the member to validate health. Change-Id: I8a67efb7113ffa49b2805b37c3855373b17e5789 Story: 2001280 Task: 5826
18 lines
699 B
YAML
18 lines
699 B
YAML
---
|
|
issues:
|
|
- |
|
|
Amphora images with HAProxy older than 1.6 (CentOS 7, etc.) will still
|
|
use health monitor type TCP when PING is selected by the user.
|
|
upgrade:
|
|
- |
|
|
Amphora will need to be updated to a new image with this version of the
|
|
agent and ping-wrapper.sh script prior to updating the Octavia controllers.
|
|
If a load balancer is using a health monitor of type PING with an
|
|
amphora image that has not been updated, the next configuration change to
|
|
the load balancer will cause it to go into an ERROR state until it is
|
|
failed over to an updated image.
|
|
fixes:
|
|
- |
|
|
Fixed an issue where health monitors of type PING were really doing a
|
|
TCP health check.
|