be91493332
In case of DB outages when a flow is running, an exception is caught and the flow is reverted. In most of the flows, the revert function of the first task's (the last to be reverted) unlocks the load balancer by setting its provisioning status (to ERROR or ACTIVE, depending on the flow), but it fails if the DB is not reachable, leaving the LB in a PENDING_* state. This commit adds tenacity.retry to those functions, Octavia retries to set the status during ~2h45 (2000 attempts, 1 sec initial delay, 5 sec max delay). Closes-Bug: #2036952 Change-Id: I458dd6d6f5383edc24116ea0fa27e3a593044146
8 lines
314 B
YAML
8 lines
314 B
YAML
---
|
|
fixes:
|
|
- |
|
|
Fixed an issue with load balancers stuck in a ``PENDING_*`` state during
|
|
database outages. Now when a task fails in Octavia, it retries to update
|
|
the ``provisioning_status`` of the load balancer until the database is back
|
|
(or it gives up after a really long timeout - around 2h45)
|