Reduce init restart/kill times
The systemd unit 'TimeoutSec' value which controls the time between sending a SIGTERM signal and a SIGKILL signal when stopping or restarting the service has been reduced from 300 seconds to 120 seconds. This provides 2 minutes for long-lived sessions to drain while preventing new ones from starting before a restart or a stop. The 'RestartSec' value which controls the time between the service stop and start when restarting has been reduced from 150 seconds to 2 seconds to make the restart happen faster. These values can be adjusted by using the *_init_config_overrides variables which use the config_template task to change template defaults. Change-Id: I707b764758c7cc04445b4f0d6efebff8a7a7a81c
This commit is contained in:
parent
a51775e99f
commit
4294f6016b
@ -0,0 +1,23 @@
|
||||
---
|
||||
features:
|
||||
- For the ``os_octavia`` role, the systemd unit ``TimeoutSec`` value which
|
||||
controls the time between sending a SIGTERM signal and a SIGKILL signal
|
||||
when stopping or restarting the service has been reduced from 300 seconds
|
||||
to 120 seconds. This provides 2 minutes for long-lived sessions to drain
|
||||
while preventing new ones from starting before a restart or a stop. The
|
||||
``RestartSec`` value which controls the time between the service stop and
|
||||
start when restarting has been reduced from 150 seconds to 2 seconds to
|
||||
make the restart happen faster. These values can be adjusted by using the
|
||||
``octavia_*_init_overrides`` variables which use the
|
||||
``config_template`` task to change template defaults.
|
||||
upgrade:
|
||||
- For the ``os_octavia`` role, the systemd unit ``TimeoutSec`` value which
|
||||
controls the time between sending a SIGTERM signal and a SIGKILL signal
|
||||
when stopping or restarting the service has been reduced from 300 seconds
|
||||
to 120 seconds. This provides 2 minutes for long-lived sessions to drain
|
||||
while preventing new ones from starting before a restart or a stop. The
|
||||
``RestartSec`` value which controls the time between the service stop and
|
||||
start when restarting has been reduced from 150 seconds to 2 seconds to
|
||||
make the restart happen faster. These values can be adjusted by using the
|
||||
``octavia_*_init_overrides`` variables which use the
|
||||
``config_template`` task to change template defaults.
|
@ -17,9 +17,9 @@ ExecStart={{ octavia_bin }}/{{ item.value.service_name }} {{ program_config_opti
|
||||
{% endif %}
|
||||
|
||||
# Give a reasonable amount of time for the server to start up/shut down
|
||||
TimeoutSec=300
|
||||
TimeoutSec=120
|
||||
Restart=on-failure
|
||||
RestartSec=150
|
||||
RestartSec=2
|
||||
|
||||
# This creates a specific slice which all services will operate from
|
||||
# The accounting options give us the ability to see resource usage through
|
||||
|
Loading…
Reference in New Issue
Block a user