From 5952acdd9309142ec804b73b05106537d46d1ea3 Mon Sep 17 00:00:00 2001 From: "Wickersham, Brian (bw6938)" Date: Mon, 16 Mar 2020 19:47:28 +0000 Subject: [PATCH] [ceph-osd] A rack's OSDs are not marked out after down_out interval An entire rack's OSDs are not being marked out after down_out interval. This manifested itself during resiliency testing when all interfaces were brought down on a control plan host and the down_interval was surpassed. Change-Id: I6f4a69ec442c3e768feb7bd74c7d610aa9d4aa67 --- ceph-mon/values.yaml | 3 +++ ceph-osd/values.yaml | 3 +++ 2 files changed, 6 insertions(+) diff --git a/ceph-mon/values.yaml b/ceph-mon/values.yaml index 527f9f5b4..9444112a2 100644 --- a/ceph-mon/values.yaml +++ b/ceph-mon/values.yaml @@ -189,6 +189,9 @@ conf: objecter_inflight_ops: 10240 debug_ms: "0/0" mon_osd_down_out_interval: 1800 + mon_osd_down_out_subtree_limit: root + mon_osd_min_in_ratio: 0 + mon_osd_min_up_ratio: 0 mon_data_avail_warn: 15 log_file: /dev/stdout mon_cluster_log_file: /dev/stdout diff --git a/ceph-osd/values.yaml b/ceph-osd/values.yaml index 985e379cf..59ec192a2 100644 --- a/ceph-osd/values.yaml +++ b/ceph-osd/values.yaml @@ -163,6 +163,9 @@ conf: objecter_inflight_ops: 10240 debug_ms: "0/0" mon_osd_down_out_interval: 1800 + mon_osd_down_out_subtree_limit: root + mon_osd_min_in_ratio: 0 + mon_osd_min_up_ratio: 0 osd: osd_mkfs_type: xfs osd_mkfs_options_xfs: -f -i size=2048