Modify the EMC VNX Direct Driver document.

Modify the EMC VNX Direct Driver document to clarify
where to find the max_luns_per_storage_group and a few
more small changes.

Change-Id: I0ae606494f968b62227e44568e5fe65ec27afde3
This commit is contained in:
Xing Yang 2014-03-31 19:46:38 -04:00
parent 01f4660a7c
commit 37765092fd

View File

@ -165,7 +165,7 @@
<para>For the VNX iSCSI driver, add the following entries, where
<literal>10.10.61.35</literal> is the IP address
of the VNX iSCSI target, <literal>10.10.72.41</literal>
is the IP address of the VNX array,
is the IP address of the VNX array (SPA or SPB),
<systemitem>default_timeout</systemitem> is the default
time out for CLI operations in minutes, and
<systemitem>max_luns_per_storage_group</systemitem> is
@ -173,7 +173,7 @@
<programlisting language="ini">
iscsi_ip_address = 10.10.61.35
san_ip = 10.10.72.41
san_login = username
san_login = global_username
san_password = password
naviseccli_path = /opt/Navisphere/bin/naviseccli
storage_vnx_pool_name = poolname
@ -181,6 +181,12 @@ default_timeout = 10
max_luns_per_storage_group=256
volume_driver=cinder.volume.drivers.emc.emc_cli_iscsi.EMCCLIISCSIDriver
</programlisting>
<note>
<para>To find out <literal>max_luns_per_storage_group
</literal> for each VNX model, refer to the
<link xlink:href="https://support.emc.com/search/?text=White%20Paper%20Introduction%20to%20the%20VNX%20Series">EMC's support</link> web site (login is required).
</para>
</note>
<para>Restart the <systemitem class="service"
>cinder-volume</systemitem> service.</para>
</section>