Merge "[config-ref] Convert lenovo-driver to RST"
This commit is contained in:
commit
6130581338
@ -1,3 +1,170 @@
|
||||
======================================
|
||||
Lenovo Fibre Channel and iSCSI drivers
|
||||
======================================
|
||||
|
||||
The ``LenovoFCDriver`` and ``LenovoISCSIDriver`` Cinder drivers allow
|
||||
Lenovo S3200 or S2200 arrays to be used for block storage in OpenStack
|
||||
deployments.
|
||||
|
||||
System requirements
|
||||
~~~~~~~~~~~~~~~~~~~
|
||||
|
||||
To use the Lenovo drivers, the following are required:
|
||||
|
||||
- Lenovo S3200 or S2200 array with:
|
||||
|
||||
- iSCSI or FC host interfaces
|
||||
|
||||
- G22x firmware or later
|
||||
|
||||
- Network connectivity between the OpenStack host and the array
|
||||
management interfaces
|
||||
|
||||
- HTTPS or HTTP must be enabled on the array
|
||||
|
||||
Supported operations
|
||||
~~~~~~~~~~~~~~~~~~~~
|
||||
|
||||
- Create, delete, attach, and detach volumes.
|
||||
|
||||
- Create, list, and delete volume snapshots.
|
||||
|
||||
- Create a volume from a snapshot.
|
||||
|
||||
- Copy an image to a volume.
|
||||
|
||||
- Copy a volume to an image.
|
||||
|
||||
- Clone a volume.
|
||||
|
||||
- Extend a volume.
|
||||
|
||||
- Migrate a volume with back-end assistance.
|
||||
|
||||
- Retype a volume.
|
||||
|
||||
- Manage and unmanage a volume.
|
||||
|
||||
Configuring the array
|
||||
~~~~~~~~~~~~~~~~~~~~~
|
||||
|
||||
#. Verify that the array can be managed using an HTTPS connection. HTTP can
|
||||
also be used if ``lenovo_api_protocol=http`` is placed into the
|
||||
appropriate sections of the ``cinder.conf`` file.
|
||||
|
||||
Confirm that virtual pools A and B are present if you plan to use
|
||||
virtual pools for OpenStack storage.
|
||||
|
||||
#. Edit the ``cinder.conf`` file to define a storage back-end entry for
|
||||
each storage pool on the array that will be managed by OpenStack. Each
|
||||
entry consists of a unique section name, surrounded by square brackets,
|
||||
followed by options specified in ``key=value`` format.
|
||||
|
||||
- The ``lenovo_backend_name`` value specifies the name of the storage
|
||||
pool on the array.
|
||||
|
||||
- The ``volume_backend_name`` option value can be a unique value, if
|
||||
you wish to be able to assign volumes to a specific storage pool on
|
||||
the array, or a name that's shared among multiple storage pools to
|
||||
let the volume scheduler choose where new volumes are allocated.
|
||||
|
||||
- The rest of the options will be repeated for each storage pool in a
|
||||
given array: the appropriate Cinder driver name; IP address or
|
||||
hostname of the array management interface; the username and password
|
||||
of an array user account with ``manage`` privileges; and the iSCSI IP
|
||||
addresses for the array if using the iSCSI transport protocol.
|
||||
|
||||
In the examples below, two back ends are defined, one for pool A and one
|
||||
for pool B, and a common ``volume_backend_name`` is used so that a
|
||||
single volume type definition can be used to allocate volumes from both
|
||||
pools.
|
||||
|
||||
**Example: iSCSI example back-end entries**
|
||||
|
||||
.. code-block:: ini
|
||||
|
||||
[pool-a]
|
||||
lenovo_backend_name = A
|
||||
volume_backend_name = lenovo-array
|
||||
volume_driver = cinder.volume.drivers.lenovo.lenovo_iscsi.LenovoISCSIDriver
|
||||
san_ip = 10.1.2.3
|
||||
san_login = manage
|
||||
san_password = !manage
|
||||
lenovo_iscsi_ips = 10.2.3.4,10.2.3.5
|
||||
|
||||
[pool-b]
|
||||
lenovo_backend_name = B
|
||||
volume_backend_name = lenovo-array
|
||||
volume_driver = cinder.volume.drivers.lenovo.lenovo_iscsi.LenovoISCSIDriver
|
||||
san_ip = 10.1.2.3
|
||||
san_login = manage
|
||||
san_password = !manage
|
||||
lenovo_iscsi_ips = 10.2.3.4,10.2.3.5
|
||||
|
||||
**Example: Fibre Channel example back-end entries**
|
||||
|
||||
.. code-block:: ini
|
||||
|
||||
[pool-a]
|
||||
lenovo_backend_name = A
|
||||
volume_backend_name = lenovo-array
|
||||
volume_driver = cinder.volume.drivers.lenovo.lenovo_fc.LenovoFCDriver
|
||||
san_ip = 10.1.2.3
|
||||
san_login = manage
|
||||
san_password = !manage
|
||||
|
||||
[pool-b]
|
||||
lenovo_backend_name = B
|
||||
volume_backend_name = lenovo-array
|
||||
volume_driver = cinder.volume.drivers.lenovo.lenovo_fc.LenovoFCDriver
|
||||
san_ip = 10.1.2.3
|
||||
san_login = manage
|
||||
san_password = !manage
|
||||
|
||||
#. If HTTPS is not enabled in the array, include
|
||||
``lenovo_api_protocol = http`` in each of the back-end definitions.
|
||||
|
||||
#. If HTTPS is enabled, you can enable certificate verification with the
|
||||
option ``lenovo_verify_certificate=True``. You may also use the
|
||||
``lenovo_verify_certificate_path`` parameter to specify the path to a
|
||||
CA_BUNDLE file containing CAs other than those in the default list.
|
||||
|
||||
#. Modify the ``[DEFAULT]`` section of the ``cinder.conf`` file to add an
|
||||
``enabled_backends`` parameter specifying the back-end entries you added,
|
||||
and a ``default_volume_type`` parameter specifying the name of a volume
|
||||
type that you will create in the next step.
|
||||
|
||||
**Example: [DEFAULT] section changes**
|
||||
|
||||
.. code-block:: ini
|
||||
|
||||
[DEFAULT]
|
||||
...
|
||||
enabled_backends = pool-a,pool-b
|
||||
default_volume_type = lenovo
|
||||
...
|
||||
|
||||
#. Create a new volume type for each distinct ``volume_backend_name`` value
|
||||
that you added to the ``cinder.conf`` file. The example below
|
||||
assumes that the same ``volume_backend_name=lenovo-array``
|
||||
option was specified in all of the
|
||||
entries, and specifies that the volume type ``lenovo`` can be used to
|
||||
allocate volumes from any of them.
|
||||
|
||||
**Example: Creating a volume type**
|
||||
|
||||
.. code-block:: console
|
||||
|
||||
$ cinder type-create lenovo
|
||||
$ cinder type-key lenovo set volume_backend_name=lenovo-array
|
||||
|
||||
#. After modifying the ``cinder.conf`` file,
|
||||
restart the ``cinder-volume`` service.
|
||||
|
||||
Driver-specific options
|
||||
~~~~~~~~~~~~~~~~~~~~~~~
|
||||
|
||||
The following table contains the configuration options that are specific
|
||||
to the Lenovo drivers.
|
||||
|
||||
.. include:: ../../tables/cinder-lenovo.rst
|
||||
|