Update Fibre Channel Zone Manager config documentation
This patch updates block storage config reference documentation by adding a section describing Fibre Channel Zone Manager and Brocade Fibre Channel Zone Driver configuration details. Change-Id: I315b92f10b7b6cb63046fa9c377cdce191450cea Closes-Bug: #1284993
This commit is contained in:
parent
f4b31857e0
commit
64f0daaf56
70
doc/config-reference/block-storage/section_fc-zoning.xml
Normal file
70
doc/config-reference/block-storage/section_fc-zoning.xml
Normal file
@ -0,0 +1,70 @@
|
||||
<section xml:id="section_fc-zoning" xmlns="http://docbook.org/ns/docbook"
|
||||
xmlns:xi="http://www.w3.org/2001/XInclude"
|
||||
xmlns:xlink="http://www.w3.org/1999/xlink" version="5.0">
|
||||
<title>Fibre Channel Zone Manager</title>
|
||||
<para>The Fibre Channel Zone Manager allows FC SAN Zone/Access
|
||||
control management in conjunction with Fibre Channel block
|
||||
storage. The configuration of Fibre Channel Zone Manager and
|
||||
various zone drivers are described in this section.</para>
|
||||
<section xml:id="enable-fc-zone-manager">
|
||||
<title>Configure Block Storage to use Fibre Channel Zone Manager
|
||||
</title>
|
||||
<para>If Block Storage is configured to use a Fibre Channel volume
|
||||
driver that supports Zone Manager, update
|
||||
<filename>cinder.conf</filename> to add the following
|
||||
configuration options to enable Fibre Channel Zone Manager.
|
||||
</para>
|
||||
<para>Make the following changes in the
|
||||
<filename>/etc/cinder/cinder.conf</filename>
|
||||
file.</para>
|
||||
<xi:include href="../../common/tables/cinder-zoning.xml"/>
|
||||
<para>To use different Fibre Channel Zone Drivers, use the
|
||||
parameters described in this section.</para>
|
||||
<note>
|
||||
<para>When multi backend configuration is used, provide
|
||||
the <option>zoning_mode</option> configuration option as
|
||||
part of the volume driver configuration where
|
||||
<option>volume_driver</option> option is specified.</para>
|
||||
</note>
|
||||
<note>
|
||||
<para>Default value of <option>zoning_mode</option> is
|
||||
<literal>None</literal> and this needs to be changed to
|
||||
<literal>fabric</literal> to allow fabric zoning.</para>
|
||||
</note>
|
||||
<note>
|
||||
<para><option>zoning_policy</option> can be configured as
|
||||
<literal>initiator-target</literal> or
|
||||
<literal>initiator</literal>
|
||||
</para>
|
||||
</note>
|
||||
</section>
|
||||
<section xml:id="brcd-fc-zone-driver">
|
||||
<title>Brocade Fibre Channel Zone Driver</title>
|
||||
<para>Brocade Fibre Channel Zone Driver performs zoning operations
|
||||
via SSH. Configure Brocade Zone Driver and lookup service by
|
||||
specifying the following parameters:</para>
|
||||
<xi:include href="../../common/tables/cinder-zoning_manager.xml"/>
|
||||
<para>Configure SAN fabric parameters in the form of fabric
|
||||
groups as described in the example below:</para>
|
||||
<xi:include href="../../common/tables/cinder-zoning_fabric.xml"/>
|
||||
<note>
|
||||
<para>Define a fabric group for each fabric using the fabric names
|
||||
used in <option>fc_fabric_names</option> configuration option
|
||||
as group name.
|
||||
</para>
|
||||
</note>
|
||||
<section xml:id="brcd-zone-driver-sys-reqs">
|
||||
<title>System requirements</title>
|
||||
<para>Brocade Fibre Channel Zone Driver requires firmware version
|
||||
FOS v6.4 or higher.</para>
|
||||
<para>As a best practice for zone management, use a user account
|
||||
with <literal>zoneadmin</literal> role.
|
||||
Users with <literal>admin</literal> role (including the default
|
||||
<literal>admin</literal> user account) are limited to a maximum
|
||||
of two concurrent SSH sessions.
|
||||
</para>
|
||||
<para>For information about how to manage Brocade Fibre Channel
|
||||
switches, see the Brocade Fabric OS user documentation.</para>
|
||||
</section>
|
||||
</section>
|
||||
</section>
|
@ -25,4 +25,5 @@
|
||||
<xi:include href="block-storage/section_backup-drivers.xml"/>
|
||||
<xi:include href="block-storage/section_block-storage-sample-configuration-files.xml" />
|
||||
<xi:include href="block-storage/section_cinder-log-files.xml"/>
|
||||
<xi:include href="block-storage/section_fc-zoning.xml"/>
|
||||
</chapter>
|
||||
|