Data collection
|
||||
===============
|
||||
|
||||
The main responsibility of Telemetry in OpenStack is to collect
|
||||
information about the system that can be used by billing systems or
|
||||
interpreted by analytic tooling. The original focus, regarding to the
|
||||
collected data, was on the counters that can be used for billing, but
|
||||
the range is getting wider continuously.
|
||||
|
||||
Collected data can be stored in the form of samples or events in the
|
||||
supported databases, listed in :ref:`telemetry-supported-databases`.
|
||||
|
||||
Samples can have various sources regarding to the needs and
|
||||
configuration of Telemetry, which requires multiple methods to collect
|
||||
data.
|
||||
|
||||
The available data collection mechanisms are:
|
||||
|
||||
Notifications
|
||||
Processing notifications from other OpenStack services, by consuming
|
||||
messages from the configured message queue system.
|
||||
|
||||
Polling
|
||||
Retrieve information directly from the hypervisor or from the host
|
||||
machine using SNMP, or by using the APIs of other OpenStack
|
||||
services.
|
||||
|
||||
RESTful API
|
||||
Pushing samples via the RESTful API of Telemetry.
|
||||
|
||||
Notifications
|
||||
~~~~~~~~~~~~~
|
||||
All the services send notifications about the executed operations or
|
||||
system state in OpenStack. Several notifications carry information that
|
||||
can be metered, like the CPU time of a VM instance created by OpenStack
|
||||
Compute service.
|
||||
|
||||
The Telemetry module has a separate agent that is responsible for
|
||||
consuming notifications, namely the notification agent. This component
|
||||
is responsible for consuming from the message bus and transforming
|
||||
notifications into events and measurement samples.
|
||||
|
||||
The different OpenStack services emit several notifications about the
|
||||
various types of events that happen in the system during normal
|
||||
operation. Not all these notifications are consumed by the Telemetry
|
||||
module, as the intention is only to capture the billable events and
|
||||
notifications that can be used for monitoring or profiling purposes. The
|
||||
notification agent filters by the event type, that is contained by each
|
||||
notification message. The following table contains the event types by
|
||||
each OpenStack service that are transformed to samples by Telemetry.
|
||||
|
||||
+--------------------+------------------------+-------------------------------+
|
||||
| OpenStack service | Event types | Note |
|
||||
+====================+========================+===============================+
|
||||
| OpenStack Compute | scheduler.run\_insta\ | For a more detailed list of |
|
||||
| | nce.scheduled | Compute notifications please |
|
||||
| | | check the `System Usage Data |
|
||||
| | scheduler.select\_\ | Data wiki page <https://wiki |
|
||||
| | destinations | .openstack.org/wiki/ |
|
||||
| | | SystemUsageData>`__. |
|
||||
| | compute.instance.\* | |
|
||||
+--------------------+------------------------+-------------------------------+
|
||||
| Bare metal service | hardware.ipmi.\* | |
|
||||
+--------------------+------------------------+-------------------------------+
|
||||
| OpenStack Image | image.update | The required configuration |
|
||||
| service | | for Image service can be |
|
||||
| | image.upload | found in `Configure the Image |
|
||||
| | | service for Telemetry section |
|
||||
| | image.delete | <http://docs.openstack.org |
|
||||
| | | /kilo/install-guide/install |
|
||||
| | image.send | /apt/content/ceilometer- |
|
||||
| | | glance.html>`__ section in |
|
||||
| | | the OpenStack Installation |
|
||||
| | | Guide. |
|
||||
+--------------------+------------------------+-------------------------------+
|
||||
| OpenStack | floatingip.create.end | |
|
||||
| Networking | | |
|
||||
| | floatingip.update.\* | |
|
||||
| | | |
|
||||
| | floatingip.exists | |
|
||||
| | | |
|
||||
| | network.create.end | |
|
||||
| | | |
|
||||
| | network.update.\* | |
|
||||
| | | |
|
||||
| | network.exists | |
|
||||
| | | |
|
||||
| | port.create.end | |
|
||||
| | | |
|
||||
| | port.update.\* | |
|
||||
| | | |
|
||||
| | port.exists | |
|
||||
| | | |
|
||||
| | router.create.end | |
|
||||
| | | |
|
||||
| | router.update.\* | |
|
||||
| | | |
|
||||
| | router.exists | |
|
||||
| | | |
|
||||
| | subnet.create.end | |
|
||||
| | | |
|
||||
| | subnet.update.\* | |
|
||||
| | | |
|
||||
| | subnet.exists | |
|
||||
| | | |
|
||||
| | l3.meter | |
|
||||
+--------------------+------------------------+-------------------------------+
|
||||
| Orchestration | orchestration.stack\ | |
|
||||
| module | .create.end | |
|
||||
| | | |
|
||||
| | orchestration.stack\ | |
|
||||
| | .update.end | |
|
||||
| | | |
|
||||
| | orchestration.stack\ | |
|
||||
| | .delete.end | |
|
||||
| | | |
|
||||
| | orchestration.stack\ | |
|
||||
| | .resume.end | |
|
||||
| | | |
|
||||
| | orchestration.stack\ | |
|
||||
| | .suspend.end | |
|
||||
+--------------------+------------------------+-------------------------------+
|
||||
| OpenStack Block | volume.exists | The required configuration |
|
||||
| Storage | | for Block Storage service can |
|
||||
| | volume.create.\* | be found in the `Add the |
|
||||
| | | Block Storage service agent |
|
||||
| | volume.delete.\* | for Telemetry section <http: |
|
||||
| | | //docs.openstack.org/kilo/ |
|
||||
| | volume.update.\* | install-guide/install/apt/ |
|
||||
| | | content/ceilometer-cinder |
|
||||
| | volume.resize.\* | .html>`__ section in the |
|
||||
| | | OpenStack Installation Guide. |
|
||||
| | volume.attach.\* | |
|
||||
| | | |
|
||||
| | volume.detach.\* | |
|
||||
| | | |
|
||||
| | snapshot.exists | |
|
||||
| | | |
|
||||
| | snapshot.create.\* | |
|
||||
| | | |
|
||||
| | snapshot.delete.\* | |
|
||||
| | | |
|
||||
| | snapshot.update.\* | |
|
||||
+--------------------+------------------------+-------------------------------+
|
||||
|
||||
.. note::
|
||||
|
||||
Some services require additional configuration to emit the
|
||||
notifications using the correct control exchange on the message
|
||||
queue and so forth. These configuration needs are referred in the
|
||||
above table for each OpenStack service that needs it.
|
||||
|
||||
.. note::
|
||||
|
||||
When the ``store_events`` option is set to True in
|
||||
:file:`ceilometer.conf`, the notification agent needs database access in
|
||||
order to work properly.
|
||||
|
||||
Middleware for the OpenStack Object Storage service
|
||||
---------------------------------------------------
|
||||
A subset of Object Store statistics requires additional middleware to
|
||||
be installed behind the proxy of Object Store. This additional component
|
||||
emits notifications containing data-flow-oriented meters, namely the
|
||||
``storage.objects.(incoming|outgoing).bytes values``. The list of these
|
||||
meters are listed in :ref:`telemetry-object-storage-meter`, marked with
|
||||
``notification`` as origin.
|
||||
|
||||
The instructions on how to install this middleware can be found in
|
||||
`Configure the Object Storage service for Telemetry
|
||||
<http://docs.openstack.org/kilo/install-guide/install/apt/content/ceilometer-swift.html>`__
|
||||
section in the OpenStack Installation Guide.
|
||||
|
||||
Telemetry middleware
|
||||
--------------------
|
||||
Telemetry provides the capability of counting the HTTP requests and
|
||||
responses for each API endpoint in OpenStack. This is achieved by
|
||||
storing a sample for each event marked as ``audit.http.request``,
|
||||
``audit.http.response``, ``http.request`` or ``http.response``.
|
||||
|
||||
It is recommended that these notifications be consumed as events rather
|
||||
than samples to better index the appropriate values and avoid massive
|
||||
load on the Metering database. If preferred, Telemetry can consume these
|
||||
events as samples if the services are configured to emit ``http.*``
|
||||
notifications.
|
||||
|
||||
Polling
|
||||
~~~~~~~
|
||||
The Telemetry module is intended to store a complex picture of the
|
||||
infrastructure. This goal requires additional information than what is
|
||||
provided by the events and notifications published by each service. Some
|
||||
information is not emitted directly, like resource usage of the VM
|
||||
instances.
|
||||
|
||||
Therefore Telemetry uses another method to gather this data by polling
|
||||
the infrastructure including the APIs of the different OpenStack
|
||||
services and other assets, like hypervisors. The latter case requires
|
||||
closer interaction with the compute hosts. To solve this issue,
|
||||
Telemetry uses an agent based architecture to fulfill the requirements
|
||||
against the data collection.
|
||||
|
||||
There are three types of agents supporting the polling mechanism, the
|
||||
compute agent, the central agent, and the IPMI agent. Under the hood,
|
||||
all the types of polling agents are the same ``ceilometer-polling`` agent,
|
||||
except that they load different polling plug-ins (pollsters) from
|
||||
differernt namespaces to gather data. The following subsections give
|
||||
further information regarding the architectural and configuration
|
||||
details of these components.
|
||||
|
||||
Running ceilometer-agent-compute is exactly the same as::
|
||||
|
||||
$ ceilometer-polling --polling-namespaces compute
|
||||
|
||||
|
||||
Running ceilometer-agent-central is exactly the same as::
|
||||
|
||||
$ ceilometer-polling --polling-namespaces central
|
||||
|
||||
|
||||
Running ceilometer-agent-ipmi is exactly the same as::
|
||||
|
||||
$ ceilometer-polling --polling-namespaces ipmi
|
||||
|
||||
|
||||
In addition to loading all the polling plug-ins registered in the
|
||||
specified namespaces, the ceilometer-polling agent can also specify the
|
||||
polling plug-ins to be loaded by using the ``pollster-list`` option::
|
||||
|
||||
$ ceilometer-polling --polling-namespaces central \
|
||||
--pollster-list image image.size storage.*
|
||||
|
||||
.. note::
|
||||
|
||||
HA deployment is NOT supported if the ``pollster-list`` option is
|
||||
used.
|
||||
|
||||
.. note::
|
||||
|
||||
The ceilometer-polling service is available since Kilo release.
|
||||
|
||||
Central agent
|
||||
-------------
|
||||
As the name of this agent shows, it is a central component in the
|
||||
Telemetry architecture. This agent is responsible for polling public
|
||||
REST APIs to retrieve additional information on OpenStack resources not
|
||||
already surfaced via notifications, and also for polling hardware
|
||||
resources over SNMP.
|
||||
|
||||
The following services can be polled with this agent:
|
||||
|
||||
- OpenStack Networking
|
||||
|
||||
- OpenStack Object Storage
|
||||
|
||||
- OpenStack Block Storage
|
||||
|
||||
- Hardware resources via SNMP
|
||||
|
||||
- Energy consumption meters via `Kwapi <https://launchpad.net/kwapi>`__
|
||||
framework
|
||||
|
||||
To install and configure this service use the `Install the Telemetry module
|
||||
<http://docs.openstack.org/kilo/install-guide/install/apt/content/ch_ceilometer.html>`__
|
||||
section in the OpenStack Installation Guide.
|
||||
|
||||
The central agent does not need direct database connection. The samples
|
||||
collected by this agent are sent via AMQP to the collector service or
|
||||
any external service, which is responsible for persisting the data into
|
||||
the configured database back end.
|
||||
|
||||
Compute agent
|
||||
-------------
|
||||
This agent is responsible for collecting resource usage data of VM
|
||||
instances on individual compute nodes within an OpenStack deployment.
|
||||
This mechanism requires a closer interaction with the hypervisor,
|
||||
therefore a separate agent type fulfills the collection of the related
|
||||
meters, which is placed on the host machines to locally retrieve this
|
||||
information.
|
||||
|
||||
A compute agent instance has to be installed on each and every compute
|
||||
node, installation instructions can be found in the `Install the Compute
|
||||
agent for Telemetry
|
||||
<http://docs.openstack.org/kilo/config-reference/content/ch_configuring-openstack-telemetry.html>`__
|
||||
section in the OpenStack Installation Guide.
|
||||
|
||||
Just like the central agent, this component also does not need a direct
|
||||
database connection. The samples are sent via AMQP to the collector.
|
||||
|
||||
The list of supported hypervisors can be found in
|
||||
:ref:`telemetry-supported-hypervisors`. The compute agent uses the API of the
|
||||
hypervisor installed on the compute hosts. Therefore the supported meters may
|
||||
be different in case of each virtualization back end, as each inspection tool
|
||||
provides a different set of meters.
|
||||
|
||||
The list of collected meters can be found in :ref:`telemetry-compute-meters`.
|
||||
The support column provides the information that which meter is available for
|
||||
each hypervisor supported by the Telemetry module.
|
||||
|
||||
.. note::
|
||||
|
||||
Telemetry supports Libvirt, which hides the hypervisor under it.
|
||||
|
||||
Support for HA deployment of the central and compute agent services
|
||||
-------------------------------------------------------------------
|
||||
Both the central and the compute agent can run in an HA deployment,
|
||||
which means that multiple instances of these services can run in
|
||||
parallel with workload partitioning among these running instances.
|
||||
|
||||
The `Tooz <https://pypi.python.org/pypi/tooz>`__ library provides the
|
||||
coordination within the groups of service instances. It provides an API
|
||||
above several back ends that can be used for building distributed
|
||||
applications.
|
||||
|
||||
Tooz supports `various
|
||||
drivers <http://docs.openstack.org/developer/tooz/drivers.html>`__
|
||||
including the following back end solutions:
|
||||
|
||||
- `Zookeeper <http://zookeeper.apache.org/>`__. Recommended solution by
|
||||
the Tooz project.
|
||||
|
||||
- `Redis <http://redis.io/>`__. Recommended solution by the Tooz
|
||||
project.
|
||||
|
||||
- `Memcached <http://memcached.org/>`__. Recommended for testing.
|
||||
|
||||
You must configure a supported Tooz driver for the HA deployment of the
|
||||
Telemetry services.
|
||||
|
||||
For information about the required configuration options that have to be
|
||||
set in the :file:`ceilometer.conf` configuration file for both the central
|
||||
and compute agents, see the `Coordination section
|
||||
<http://docs.openstack.org/kilo/config-reference/content/ch_configuring-openstack-telemetry.html>`__
|
||||
in the OpenStack Configuration Reference.
|
||||
|
||||
.. note::
|
||||
|
||||
Without the ``backend_url`` option being set only one instance of
|
||||
both the central and compute agent service is able to run and
|
||||
function correctly.
|
||||
|
||||
The availability check of the instances is provided by heartbeat
|
||||
messages. When the connection with an instance is lost, the workload
|
||||
will be reassigned within the remained instances in the next polling
|
||||
cycle.
|
||||
|
||||
.. note::
|
||||
|
||||
``Memcached`` uses a ``timeout`` value, which should always be set
|
||||
to a value that is higher than the ``heartbeat`` value set for
|
||||
Telemetry.
|
||||
|
||||
For backward compatibility and supporting existing deployments, the
|
||||
central agent configuration also supports using different configuration
|
||||
files for groups of service instances of this type that are running in
|
||||
parallel. For enabling this configuration set a value for the
|
||||
``partitioning_group_prefix`` option in the `Central section
|
||||
<http://docs.openstack.org/kilo/config-reference/content/ch_configuring-openstack-telemetry.html>`__
|
||||
in the OpenStack Configuration Reference.
|
||||
|
||||
.. warning::
|
||||
|
||||
For each sub-group of the central agent pool with the same
|
||||
``partitioning_group_prefix`` a disjoint subset of meters must be
|
||||
polled, otherwise samples may be missing or duplicated. The list of
|
||||
meters to poll can be set in the :file:`/etc/ceilometer/pipeline.yaml`
|
||||
configuration file. For more information about pipelines see
|
||||
:ref:`data-collection-and-processing`.
|
||||
|
||||
To enable the compute agent to run multiple instances simultaneously
|
||||
with workload partitioning, the ``workload_partitioning`` option has to
|
||||
be set to ``True`` under the `Compute section
|
||||
<http://docs.openstack.org/kilo/config-reference/content/ch_configuring-openstack-telemetry.html>`__
|
||||
in the :file:`ceilometer.conf` configuration file.
|
||||
|
||||
.. _telemetry-ipmi-agent:
|
||||
|
||||
IPMI agent
|
||||
----------
|
||||
This agent is responsible for collecting IPMI sensor data and Intel Node
|
||||
Manager data on individual compute nodes within an OpenStack deployment.
|
||||
This agent requires an IPMI capable node with the ipmitool utility installed,
|
||||
which is commonly used for IPMI control on various Linux distributions.
|
||||
|
||||
An IPMI agent instance could be installed on each and every compute node
|
||||
with IPMI support, except when the node is managed by the Bare metal
|
||||
service and the ``conductor.send_sensor_data`` option is set to ``true``
|
||||
in the Bare metal service. It is no harm to install this agent on a
|
||||
compute node without IPMI or Intel Node Manager support, as the agent
|
||||
checks for the hardware and if none is available, returns empty data. It
|
||||
is suggested that you install the IPMI agent only on an IPMI capable
|
||||
node for performance reasons.
|
||||
|
||||
Just like the central agent, this component also does not need direct
|
||||
database access. The samples are sent via AMQP to the collector.
|
||||
|
||||
The list of collected meters can be found in
|
||||
:ref:`telemetry-bare-metal-service`.
|
||||
|
||||
.. note::
|
||||
|
||||
Do not deploy both the IPMI agent and the Bare metal service on one
|
||||
compute node. If ``conductor.send_sensor_data`` is set, this
|
||||
misconfiguration causes duplicated IPMI sensor samples.
|
||||
|
||||
Send samples to Telemetry
|
||||
~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||
While most parts of the data collection in the Telemetry module are
|
||||
automated, Telemetry provides the possibility to submit samples via the
|
||||
REST API to allow users to send custom samples into this module.
|
||||
|
||||
This option makes it possible to send any kind of samples without the
|
||||
need of writing extra code lines or making configuration changes.
|
||||
|
||||
The samples that can be sent to Telemetry are not limited to the actual
|
||||
existing meters. There is a possibility to provide data for any new,
|
||||
customer defined counter by filling out all the required fields of the
|
||||
POST request.
|
||||
|
||||
If the sample corresponds to an existing meter, then the fields like
|
||||
``meter-type`` and meter name should be matched accordingly.
|
||||
|
||||
The required fields for sending a sample using the command line client
|
||||
are:
|
||||
|
||||
- ID of the corresponding resource. (``--resource-id``)
|
||||
|
||||
- Name of meter. (``--meter-name``)
|
||||
|
||||
- Type of meter. (``--meter-type``)
|
||||
|
||||
Predefined meter types:
|
||||
|
||||
- Gauge
|
||||
|
||||
- Delta
|
||||
|
||||
- Cumulative
|
||||
|
||||
- Unit of meter. (``--meter-unit``)
|
||||
|
||||
- Volume of sample. (``--sample-volume``)
|
||||
|
||||
To send samples to Telemetry using the command line client, the
|
||||
following command should be invoked::
|
||||
|
||||
$ ceilometer sample-create -r 37128ad6-daaa-4d22-9509-b7e1c6b08697 \
|
||||
-m memory.usage --meter-type gauge --meter-unit MB --sample-volume 48
|
||||
+-------------------+--------------------------------------------+
|
||||
| Property | Value |
|
||||
+-------------------+--------------------------------------------+
|
||||
| message_id | 6118820c-2137-11e4-a429-08002715c7fb |
|
||||
| name | memory.usage |
|
||||
| project_id | e34eaa91d52a4402b4cb8bc9bbd308c1 |
|
||||
| resource_id | 37128ad6-daaa-4d22-9509-b7e1c6b08697 |
|
||||
| resource_metadata | {} |
|
||||
| source | e34eaa91d52a4402b4cb8bc9bbd308c1:openstack |
|
||||
| timestamp | 2014-08-11T09:10:46.358926 |
|
||||
| type | gauge |
|
||||
| unit | MB |
|
||||
| user_id | 679b0499e7a34ccb9d90b64208401f8e |
|
||||
| volume | 48.0 |
|
||||
+-------------------+--------------------------------------------+
|
||||
|
||||
.. _data-collection-and-processing:
|
||||
|
||||
Data collection and processing
|
||||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||
The mechanism by which data is collected and processed is called a
|
||||
pipeline. Pipelines, at the configuration level, describe a coupling
|
||||
between sources of data and the corresponding sinks for transformation
|
||||
and publication of data.
|
||||
|
||||
A source is a producer of data: samples or events. In effect, it is a
|
||||
set of pollsters or notification handlers emitting datapoints for a set
|
||||
of matching meters and event types.
|
||||
|
||||
Each source configuration encapsulates name matching, polling interval
|
||||
determination, optional resource enumeration or discovery, and mapping
|
||||
to one or more sinks for publication.
|
||||
|
||||
Data gathered can be used for different purposes, which can impact how
|
||||
frequently it needs to be published. Typically, a meter published for
|
||||
billing purposes needs to be updated every 30 minutes while the same
|
||||
meter may be needed for performance tuning every minute.
|
||||
|
||||
.. warning::
|
||||
|
||||
Rapid polling cadences should be avoided, as it results in a huge
|
||||
amount of data in a short time frame, which may negatively affect
|
||||
the performance of both Telemetry and the underlying database back
|
||||
end. We therefore strongly recommend you do not use small
|
||||
granularity values like 10 seconds.
|
||||
|
||||
A sink, on the other hand, is a consumer of data, providing logic for
|
||||
the transformation and publication of data emitted from related sources.
|
||||
|
||||
In effect, a sink describes a chain of handlers. The chain starts with
|
||||
zero or more transformers and ends with one or more publishers. The
|
||||
first transformer in the chain is passed data from the corresponding
|
||||
source, takes some action such as deriving rate of change, performing
|
||||
unit conversion, or aggregating, before passing the modified data to the
|
||||
next step that is described in :ref:`telemetry-publishers`.
|
||||
|
||||
.. _telemetry-pipeline-configuration:
|
||||
|
||||
Pipeline configuration
|
||||
----------------------
|
||||
Pipeline configuration by default, is stored in separate configuration
|
||||
files, called :file:`pipeline.yaml` and :file:`event_pipeline.yaml`, next to
|
||||
the :file:`ceilometer.conf` file. The meter pipeline and event pipeline
|
||||
configuration files can be set by the ``pipeline_cfg_file`` and
|
||||
``event_pipeline_cfg_file`` options listed in the `Description of
|
||||
configuration options for api table
|
||||
<http://docs.openstack.org/kilo/config-reference/content/ch_configuring-openstack-telemetry.html>`__
|
||||
section in the OpenStack Configuration Reference respectively. Multiple
|
||||
pipelines can be defined in one pipeline configuration file.
|
||||
|
||||
The meter pipeline definition looks like the following::
|
||||
|
||||
---
|
||||
sources:
|
||||
- name: 'source name'
|
||||
interval: 'how often should the samples be injected into the pipeline'
|
||||
meters:
|
||||
- 'meter filter'
|
||||
resources:
|
||||
- 'list of resource URLs'
|
||||
sinks
|
||||
- 'sink name'
|
||||
sinks:
|
||||
- name: 'sink name'
|
||||
transformers: 'definition of transformers'
|
||||
publishers:
|
||||
- 'list of publishers'
|
||||
|
||||
The interval parameter in the sources section should be defined in
|
||||
seconds. It determines the polling cadence of sample injection into the
|
||||
pipeline, where samples are produced under the direct control of an
|
||||
agent.
|
||||
|
||||
There are several ways to define the list of meters for a pipeline
|
||||
source. The list of valid meters can be found in :ref:`telemetry-measurements`.
|
||||
There is a possibility to define all the meters, or just included or excluded
|
||||
meters, with which a source should operate:
|
||||
|
||||
- To include all meters, use the ``*`` wildcard symbol. It is highly
|
||||
advisable to select only the meters that you intend on using to avoid
|
||||
flooding the metering database with unused data.
|
||||
|
||||
- To define the list of meters, use either of the following:
|
||||
|
||||
- To define the list of included meters, use the ``meter_name``
|
||||
syntax.
|
||||
|
||||
- To define the list of excluded meters, use the ``!meter_name``
|
||||
syntax.
|
||||
|
||||
- For meters, which have variants identified by a complex name
|
||||
field, use the wildcard symbol to select all, e.g. for
|
||||
"instance:m1.tiny", use "instance:\*".
|
||||
|
||||
.. note::
|
||||
|
||||
Please be aware that we do not have any duplication check between
|
||||
pipelines and if you add a meter to multiple pipelines then it is
|
||||
assumed the duplication is intentional and may be stored multiple
|
||||
times according to the specified sinks.
|
||||
|
||||
The above definition methods can be used in the following combinations:
|
||||
|
||||
- Use only the wildcard symbol.
|
||||
|
||||
- Use the list of included meters.
|
||||
|
||||
- Use the list of excluded meters.
|
||||
|
||||
- Use wildcard symbol with the list of excluded meters.
|
||||
|
||||
.. note::
|
||||
|
||||
At least one of the above variations should be included in the
|
||||
meters section. Included and excluded meters cannot co-exist in the
|
||||
same pipeline. Wildcard and included meters cannot co-exist in the
|
||||
same pipeline definition section.
|
||||
|
||||
The optional resources section of a pipeline source allows a static list
|
||||
of resource URLs to be configured for polling.
|
||||
|
||||
The transformers section of a pipeline sink provides the possibility to
|
||||
add a list of transformer definitions. The available transformers are:
|
||||
|
||||
+-----------------------+------------------------------------+
|
||||
| Name of transformer | Reference name for configuration |
|
||||
+=======================+====================================+
|
||||
| Accumulator | accumulator |
|
||||
+-----------------------+------------------------------------+
|
||||
| Aggregator | aggregator |
|
||||
+-----------------------+------------------------------------+
|
||||
| Arithmetic | arithmetic |
|
||||
+-----------------------+------------------------------------+
|
||||
| Rate of change | rate\_of\_change |
|
||||
+-----------------------+------------------------------------+
|
||||
| Unit conversion | unit\_conversion |
|
||||
+-----------------------+------------------------------------+
|
||||
|
||||
The publishers section contains the list of publishers, where the
|
||||
samples data should be sent after the possible transformations.
|
||||
|
||||
Similarly, the event pipeline definition looks like the following::
|
||||
|
||||
---
|
||||
sources:
|
||||
- name: 'source name'
|
||||
events:
|
||||
- 'event filter'
|
||||
sinks
|
||||
- 'sink name'
|
||||
sinks:
|
||||
- name: 'sink name'
|
||||
publishers:
|
||||
- 'list of publishers'
|
||||
|
||||
The event filter uses the same filtering logic as the meter pipeline.
|
||||
|
||||
.. _telemetry-transformers:
|
||||
|
||||
Transformers
|
||||
^^^^^^^^^^^^
|
||||
|
||||
The definition of transformers can contain the following fields:
|
||||
|
||||
name
|
||||
Name of the transformer.
|
||||
|
||||
parameters
|
||||
Parameters of the transformer.
|
||||
|
||||
The parameters section can contain transformer specific fields, like
|
||||
source and target fields with different subfields in case of the rate of
|
||||
change, which depends on the implementation of the transformer.
|
||||
|
||||
In the case of the transformer that creates the ``cpu_util`` meter, the
|
||||
definition looks like the following::
|
||||
|
||||
transformers:
|
||||
- name: "rate_of_change"
|
||||
parameters:
|
||||
target:
|
||||
name: "cpu_util"
|
||||
unit: "%"
|
||||
type: "gauge"
|
||||
scale: "100.0 / (10**9 * (resource_metadata.cpu_number or 1))"
|
||||
|
||||
The rate of change the transformer generates is the ``cpu_util`` meter
|
||||
from the sample values of the ``cpu`` counter, which represents
|
||||
cumulative CPU time in nanoseconds. The transformer definition above
|
||||
defines a scale factor (for nanoseconds and multiple CPUs), which is
|
||||
applied before the transformation derives a sequence of gauge samples
|
||||
with unit '%', from sequential values of the ``cpu`` meter.
|
||||
|
||||
The definition for the disk I/O rate, which is also generated by the
|
||||
rate of change transformer::
|
||||
|
||||
transformers:
|
||||
- name: "rate_of_change"
|
||||
parameters:
|
||||
source:
|
||||
map_from:
|
||||
name: "disk\\.(read|write)\\.(bytes|requests)"
|
||||
unit: "(B|request)"
|
||||
target:
|
||||
map_to:
|
||||
name: "disk.\\1.\\2.rate"
|
||||
unit: "\\1/s"
|
||||
type: "gauge"
|
||||
|
||||
**Unit conversion transformer**
|
||||
|
||||
Transformer to apply a unit conversion. It takes the volume of the meter
|
||||
and multiplies it with the given ``scale`` expression. Also supports
|
||||
``map_from`` and ``map_to`` like the rate of change transformer.
|
||||
|
||||
Sample configuration::
|
||||
|
||||
transformers:
|
||||
- name: "unit_conversion"
|
||||
parameters:
|
||||
target:
|
||||
name: "disk.kilobytes"
|
||||
unit: "KB"
|
||||
scale: "1.0 / 1024.0"
|
||||
|
||||
With ``map_from`` and ``map_to`` ::
|
||||
|
||||
transformers:
|
||||
- name: "unit_conversion"
|
||||
parameters:
|
||||
source:
|
||||
map_from:
|
||||
name: "disk\\.(read|write)\\.bytes"
|
||||
target:
|
||||
map_to:
|
||||
name: "disk.\\1.kilobytes"
|
||||
scale: "1.0 / 1024.0"
|
||||
unit: "KB"
|
||||
|
||||
**Aggregator transformer**
|
||||
|
||||
A transformer that sums up the incoming samples until enough samples
|
||||
have come in or a timeout has been reached.
|
||||
|
||||
Timeout can be specified with the ``retention_time`` option. If we want
|
||||
to flush the aggregation after a set number of samples have been
|
||||
aggregated, we can specify the size parameter.
|
||||
|
||||
The volume of the created sample is the sum of the volumes of samples
|
||||
that came into the transformer. Samples can be aggregated by the
|
||||
attributes ``project_id``, ``user_id`` and ``resource_metadata``. To aggregate
|
||||
by the chosen attributes, specify them in the configuration and set which
|
||||
value of the attribute to take for the new sample (first to take the
|
||||
first sample's attribute, last to take the last sample's attribute, and
|
||||
drop to discard the attribute).
|
||||
|
||||
To aggregate 60s worth of samples by ``resource_metadata`` and keep the
|
||||
``resource_metadata`` of the latest received sample::
|
||||
|
||||
transformers:
|
||||
- name: "aggregator"
|
||||
parameters:
|
||||
retention_time: 60
|
||||
resource_metadata: last
|
||||
|
||||
To aggregate each 15 samples by ``user_id`` and ``resource_metadata`` and keep
|
||||
the ``user_id`` of the first received sample and drop the
|
||||
``resource_metadata``::
|
||||
|
||||
transformers:
|
||||
- name: "aggregator"
|
||||
parameters:
|
||||
size: 15
|
||||
user_id: first
|
||||
resource_metadata: drop
|
||||
|
||||
**Accumulator transformer**
|
||||
|
||||
This transformer simply caches the samples until enough samples have
|
||||
arrived and then flushes them all down the pipeline at once::
|
||||
|
||||
transformers:
|
||||
- name: "accumulator"
|
||||
parameters:
|
||||
size: 15
|
||||
|
||||
**Muli meter arithmetic transformer**
|
||||
|
||||
This transformer enables us to perform arithmetic calculations over one
|
||||
or more meters and/or their metadata, for example::
|
||||
|
||||
memory_util = 100 * memory.usage / memory
|
||||
|
||||
A new sample is created with the properties described in the ``target``
|
||||
section of the transformer's configuration. The sample's
|
||||
volume is the result of the provided expression. The calculation is
|
||||
performed on samples from the same resource.
|
||||
|
||||
.. note::
|
||||
|
||||
The calculation is limited to meters with the same interval.
|
||||
|
||||
Example configuration::
|
||||
|
||||
transformers:
|
||||
- name: "arithmetic"
|
||||
parameters:
|
||||
target:
|
||||
name: "memory_util"
|
||||
unit: "%"
|
||||
type: "gauge"
|
||||
expr: "100 * $(memory.usage) / $(memory)"
|
||||
|
||||
To demonstrate the use of metadata, here is the implementation of a
|
||||
silly meter that shows average CPU time per core::
|
||||
|
||||
transformers:
|
||||
- name: "arithmetic"
|
||||
parameters:
|
||||
target:
|
||||
name: "avg_cpu_per_core"
|
||||
unit: "ns"
|
||||
type: "cumulative"
|
||||
expr: "$(cpu) / ($(cpu).resource_metadata.cpu_number or 1)"
|
||||
|
||||
.. note::
|
||||
|
||||
Expression evaluation gracefully handles NaNs and exceptions. In
|
||||
such a case it does not create a new sample but only logs a warning.
|
||||
|
||||
Block Storage audit script setup to get notifications
|
||||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||
If you want to collect OpenStack Block Storage notification on demand,
|
||||
you can use ``cinder-volume-usage-audit`` from OpenStack Block Storage.
|
||||
This script becomes available when you install OpenStack Block Storage,
|
||||
so you can use it without any specific settings and you don't need to
|
||||
authenticate to access the data. To use it, you must run this command in
|
||||
the following format::
|
||||
|
||||
$ cinder-volume-usage-audit \
|
||||
--start_time='YYYY-MM-DD HH:MM:SS' --end_time='YYYY-MM-DD HH:MM:SS' --send_actions
|
||||
|
||||
This script outputs what volumes or snapshots were created, deleted, or
|
||||
exists in a given period of time and some information about these
|
||||
volumes or snapshots. Information about the existence and size of
|
||||
volumes and snapshots is store in the Telemetry module. This data is
|
||||
also stored as an event which is the recommended usage as it provides
|
||||
better indexing of data.
|
||||
|
||||
Using this script via cron you can get notifications periodically, for
|
||||
example, every 5 minutes::
|
||||
|
||||
*/5 * * * * /path/to/cinder-volume-usage-audit --send_actions
|
||||
|
||||
.. _telemetry-storing-samples:
|
||||
|
||||
Storing samples
|
||||
~~~~~~~~~~~~~~~
|
||||
The Telemetry module has a separate service that is responsible for
|
||||
persisting the data that comes from the pollsters or is received as
|
||||
notifications. The data can be stored in a file or a database back end,
|
||||
for which the list of supported databases can be found in
|
||||
:ref:`telemetry-supported-databases`. The data can also be sent to an external
|
||||
data store by using an HTTP dispatcher.
|
||||
|
||||
The ``ceilometer-collector`` service receives the data as messages from the
|
||||
message bus of the configured AMQP service. It sends these datapoints
|
||||
without any modification to the configured target. The service has to
|
||||
run on a host machine from which it has access to the configured
|
||||
dispatcher.
|
||||
|
||||
.. note::
|
||||
|
||||
Multiple dispatchers can be configured for Telemetry at one time.
|
||||
|
||||
Multiple ``ceilometer-collector`` processes can be run at a time. It is also
|
||||
supported to start multiple worker threads per collector process. The
|
||||
``collector_workers`` configuration option has to be modified in the
|
||||
`Collector section
|
||||
<http://docs.openstack.org/kilo/config-reference/content/ch_configuring-openstack-telemetry.html>`__
|
||||
of the :file:`ceilometer.conf` configuration file.
|
||||
|
||||
.. note::
|
||||
|
||||
Prior to the Juno release, it is not recommended to use multiple
|
||||
workers per collector process when using PostgreSQL as the database
|
||||
back end.
|
||||
|
||||
Database dispatcher
|
||||
-------------------
|
||||
When the database dispatcher is configured as data store, you have the
|
||||
option to set a ``time_to_live`` option (ttl) for samples. By default
|
||||
the time to live value for samples is set to -1, which means that they
|
||||
are kept in the database forever.
|
||||
|
||||
The time to live value is specified in seconds. Each sample has a time
|
||||
stamp, and the ``ttl`` value indicates that a sample will be deleted
|
||||
from the database when the number of seconds has elapsed since that
|
||||
sample reading was stamped. For example, if the time to live is set to
|
||||
600, all samples older than 600 seconds will be purged from the
|
||||
database.
|
||||
|
||||
Certain databases support native TTL expiration. In cases where this is
|
||||
not possible, a command-line script, which you can use for this purpose
|
||||
is ceilometer-expirer. You can run it in a cron job, which helps to keep
|
||||
your database in a consistent state.
|
||||
|
||||
The level of support differs in case of the configured back end:
|
||||
|
||||
+--------------------+-------------------+------------------------------------+
|
||||
| Database | TTL value support | Note |
|
||||
+====================+===================+====================================+
|
||||
| MongoDB | Yes | MongoDB has native TTL support for |
|
||||
| | | deleting samples that are older |
|
||||
| | | than the configured ttl value. |
|
||||
+--------------------+-------------------+------------------------------------+
|
||||
| SQL-based back | Yes | ceilometer-expirer has to be used |
|
||||
| ends | | for deleting samples and its |
|
||||
| | | related data from the database. |
|
||||
+--------------------+-------------------+------------------------------------+
|
||||
| HBase | No | Telemetry's HBase support does not |
|
||||
| | | include native TTL nor |
|
||||
| | | ceilometer-expirer support. |
|
||||
+--------------------+-------------------+------------------------------------+
|
||||
| DB2 NoSQL | No | DB2 NoSQL does not have native TTL |
|
||||
| | | nor ceilometer-expirer support. |
|
||||
+--------------------+-------------------+------------------------------------+
|
||||
|
||||
HTTP dispatcher
|
||||
---------------
|
||||
The Telemetry module supports sending samples to an external HTTP
|
||||
target. The samples are sent without any modification. To set this
|
||||
option as the collector's target, the ``dispatcher`` has to be changed
|
||||
to ``http`` in the :file:`ceilometer.conf` configuration file. For the list
|
||||
of options that you need to set, see the see the `dispatcher_http
|
||||
section <http://docs.openstack.org/kilo/config-reference/content/ch_configuring-openstack-telemetry.html>`__
|
||||
in the OpenStack Configuration Reference.
|
||||
|
||||
File dispatcher
|
||||
---------------
|
||||
You can store samples in a file by setting the ``dispatcher`` option in the
|
||||
:file:`ceilometer.conf` file. For the list of configuration options,
|
||||
see the `dispatcher_file section
|
||||
<http://docs.openstack.org/kilo/config-reference/content/ch_configuring-openstack-telemetry.html>`__
|
||||
in the OpenStack Configuration Reference.
|
497
doc/admin-guide-cloud-rst/source/telemetry-data-retrieval.rst
Normal file
497
doc/admin-guide-cloud-rst/source/telemetry-data-retrieval.rst
Normal file
@ -0,0 +1,497 @@
|
||||
==============
|
||||
Data retrieval
|
||||
==============
|
||||
|
||||
The Telemetry module offers several mechanisms from which the persisted
|
||||
data can be accessed. As described in :ref:`telemetry-system-architecture` and
|
||||
in :ref:`telemetry-data-collection`, the collected information can be stored in
|
||||
one or more database back ends, which are hidden by the Telemetry RESTful API.
|
||||
|
||||
.. note::
|
||||
|
||||
It is highly recommended not to access directly the database and
|
||||
read or modify any data in it. The API layer hides all the changes
|
||||
in the actual database schema and provides a standard interface to
|
||||
expose the samples, alarms and so forth.
|
||||
|
||||
Telemetry v2 API
|
||||
~~~~~~~~~~~~~~~~
|
||||
The Telemetry module provides a RESTful API, from which the collected
|
||||
samples and all the related information can be retrieved, like the list
|
||||
of meters, alarm definitions and so forth.
|
||||
|
||||
The Telemetry API URL can be retrieved from the service catalog provided
|
||||
by OpenStack Identity, which is populated during the installation
|
||||
process. The API access needs a valid token and proper permission to
|
||||
retrieve data, as described in :ref:`telemetry-users-roles-tenants`.
|
||||
|
||||
Further information about the available API endpoints can be found in
|
||||
the `Telemetry API Reference
|
||||
<http://developer.openstack.org/api-ref-telemetry-v2.html>`__.
|
||||
|
||||
Query
|
||||
-----
|
||||
The API provides some additional functionalities, like querying the
|
||||
collected data set. For the samples and alarms API endpoints, both
|
||||
simple and complex query styles are available, whereas for the other
|
||||
endpoints only simple queries are supported.
|
||||
|
||||
After validating the query parameters, the processing is done on the
|
||||
database side in the case of most database back ends in order to achieve
|
||||
better performance.
|
||||
|
||||
**Simple query**
|
||||
|
||||
Many of the API endpoints accept a query filter argument, which should
|
||||
be a list of data structures that consist of the following items:
|
||||
|
||||
- ``field``
|
||||
|
||||
- ``op``
|
||||
|
||||
- ``value``
|
||||
|
||||
- ``type``
|
||||
|
||||
Regardless of the endpoint on which the filter is applied on, it will
|
||||
always target the fields of the `Sample type
|
||||
<http://docs.openstack.org/developer/ceilometer/webapi/v2.html#Sample>`__.
|
||||
|
||||
Several fields of the API endpoints accept shorter names than the ones
|
||||
defined in the reference. The API will do the transformation internally
|
||||
and return the output with the fields that are listed in the `API reference
|
||||
<http://docs.openstack.org/developer/ceilometer/webapi/v2.html>`__.
|
||||
The fields are the following:
|
||||
|
||||
- ``project_id``: project
|
||||
|
||||
- ``resource_id``: resource
|
||||
|
||||
- ``user_id``: user
|
||||
|
||||
When a filter argument contains multiple constraints of the above form,
|
||||
a logical ``AND`` relation between them is implied.
|
||||
|
||||
.. _complex-query:
|
||||
|
||||
**Complex query**
|
||||
|
||||
The filter expressions of the complex query feature operate on the
|
||||
fields of ``Sample``, ``Alarm`` and ``AlarmChange`` types. The following
|
||||
comparison operators are supported:
|
||||
|
||||
- ``=``
|
||||
|
||||
- ``!=``
|
||||
|
||||
- ``<``
|
||||
|
||||
- ``<=``
|
||||
|
||||
- ``>``
|
||||
|
||||
- ``>=``
|
||||
|
||||
The following logical operators can be used:
|
||||
|
||||
- ``and``
|
||||
|
||||
- ``or``
|
||||
|
||||
- ``not``
|
||||
|
||||
.. note::
|
||||
|
||||
The ``not`` operator has different behavior in MongoDB and in the
|
||||
SQLAlchemy-based database engines. If the ``not`` operator is
|
||||
applied on a non existent metadata field then the result depends on
|
||||
the database engine. In case of MongoDB, it will return every sample
|
||||
as the ``not`` operator is evaluated true for every sample where the
|
||||
given field does not exist. On the other hand the SQL-based database
|
||||
engine will return an empty result because of the underlying
|
||||
``join`` operation.
|
||||
|
||||
Complex query supports specifying a list of ``orderby`` expressions.
|
||||
This means that the result of the query can be ordered based on the
|
||||
field names provided in this list. When multiple keys are defined for
|
||||
the ordering, these will be applied sequentially in the order of the
|
||||
specification. The second expression will be applied on the groups for
|
||||
which the values of the first expression are the same. The ordering can
|
||||
be ascending or descending.
|
||||
|
||||
The number of returned items can be bounded using the ``limit`` option.
|
||||
|
||||
The ``filter``, ``orderby`` and ``limit`` fields are optional.
|
||||
|
||||
.. note::
|
||||
|
||||
As opposed to the simple query, complex query is available via a
|
||||
separate API endpoint. For more information see the `Telemetry v2 Web API
|
||||
Reference <http://docs.openstack.org/developer/ceilometer/webapi/v2.html#v2-web-api>`__.
|
||||
|
||||
Statistics
|
||||
----------
|
||||
The sample data can be used in various ways for several purposes, like
|
||||
billing or profiling. In external systems the data is often used in the
|
||||
form of aggregated statistics. The Telemetry API provides several
|
||||
built-in functions to make some basic calculations available without any
|
||||
additional coding.
|
||||
|
||||
Telemetry supports the following statistics and aggregation functions:
|
||||
|
||||
``avg``
|
||||
Average of the sample volumes over each period.
|
||||
|
||||
``cardinality``
|
||||
Count of distinct values in each period identified by a key
|
||||
specified as the parameter of this aggregate function. The supported
|
||||
parameter values are:
|
||||
|
||||
- ``project_id``
|
||||
|
||||
- ``resource_id``
|
||||
|
||||
- ``user_id``
|
||||
|
||||
.. note::
|
||||
|
||||
The ``aggregate.param`` option is required.
|
||||
|
||||
``count``
|
||||
Number of samples in each period.
|
||||
|
||||
``max``
|
||||
Maximum of the sample volumes in each period.
|
||||
|
||||
``min``
|
||||
Minimum of the sample volumes in each period.
|
||||
|
||||
``stddev``
|
||||
Standard deviation of the sample volumes in each period.
|
||||
|
||||
``sum``
|
||||
Sum of the sample volumes over each period.
|
||||
|
||||
The simple query and the statistics functionality can be used together
|
||||
in a single API request.
|
||||
|
||||
Telemetry command line client and SDK
|
||||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||
The Telemetry module provides a command line client, with which the
|
||||
collected data is available just as the alarm definition and retrieval
|
||||
options. The client uses the Telemetry RESTful API in order to execute
|
||||
the requested operations.
|
||||
|
||||
To be able to use the ``ceilometer`` command, the
|
||||
python-ceilometerclient package needs to be installed and configured
|
||||
properly. For details about the installation process, see the `Telemetry
|
||||
chapter <http://docs.openstack.org/kilo/install-guide/install/apt/content/ch_ceilometer.html>`__
|
||||
in the OpenStack Installation Guide.
|
||||
|
||||
.. note::
|
||||
|
||||
The Telemetry module captures the user-visible resource usage data.
|
||||
Therefore the database will not contain any data without the
|
||||
existence of these resources, like VM images in the OpenStack Image
|
||||
service.
|
||||
|
||||
Similarly to other OpenStack command line clients, the ``ceilometer``
|
||||
client uses OpenStack Identity for authentication. The proper
|
||||
credentials and ``--auth_url`` parameter have to be defined via command
|
||||
line parameters or environment variables.
|
||||
|
||||
This section provides some examples without the aim of completeness.
|
||||
These commands can be used for instance for validating an installation
|
||||
of Telemetry.
|
||||
|
||||
To retrieve the list of collected meters, the following command should
|
||||
be used::
|
||||
|
||||
$ ceilometer meter-list
|
||||
+------------------------+------------+------+------------------------------------------+----------------------------------+----------------------------------+
|
||||
| Name | Type | Unit | Resource ID | User ID | Project ID |
|
||||
+------------------------+------------+------+------------------------------------------+----------------------------------+----------------------------------+
|
||||
| cpu | cumulative | ns | bb52e52b-1e42-4751-b3ac-45c52d83ba07 | b6e62aad26174382bc3781c12fe413c8 | cbfa8e3dfab64a27a87c8e24ecd5c60f |
|
||||
| cpu | cumulative | ns | c8d2e153-a48f-4cec-9e93-86e7ac6d4b0b | b6e62aad26174382bc3781c12fe413c8 | cbfa8e3dfab64a27a87c8e24ecd5c60f |
|
||||
| cpu_util | gauge | % | bb52e52b-1e42-4751-b3ac-45c52d83ba07 | b6e62aad26174382bc3781c12fe413c8 | cbfa8e3dfab64a27a87c8e24ecd5c60f |
|
||||
| cpu_util | gauge | % | c8d2e153-a48f-4cec-9e93-86e7ac6d4b0b | b6e62aad26174382bc3781c12fe413c8 | cbfa8e3dfab64a27a87c8e24ecd5c60f |
|
||||
| disk.device.read.bytes | cumulative | B | bb52e52b-1e42-4751-b3ac-45c52d83ba07-hdd | b6e62aad26174382bc3781c12fe413c8 | cbfa8e3dfab64a27a87c8e24ecd5c60f |
|
||||
| disk.device.read.bytes | cumulative | B | bb52e52b-1e42-4751-b3ac-45c52d83ba07-vda | b6e62aad26174382bc3781c12fe413c8 | cbfa8e3dfab64a27a87c8e24ecd5c60f |
|
||||
| disk.device.read.bytes | cumulative | B | c8d2e153-a48f-4cec-9e93-86e7ac6d4b0b-hdd | b6e62aad26174382bc3781c12fe413c8 | cbfa8e3dfab64a27a87c8e24ecd5c60f |
|
||||
| disk.device.read.bytes | cumulative | B | c8d2e153-a48f-4cec-9e93-86e7ac6d4b0b-vda | b6e62aad26174382bc3781c12fe413c8 | cbfa8e3dfab64a27a87c8e24ecd5c60f |
|
||||
| ... |
|
||||
+------------------------+------------+------+------------------------------------------+----------------------------------+----------------------------------+
|
||||
|
||||
The ``ceilometer`` command was run with ``admin`` rights, which means
|
||||
that all the data is accessible in the database. For more information
|
||||
about access right see :ref:`telemetry-users-roles-tenants`. As it can be seen
|
||||
in the above example, there are two VM instances existing in the system, as
|
||||
there are VM instance related meters on the top of the result list. The
|
||||
existence of these meters does not indicate that these instances are running at
|
||||
the time of the request. The result contains the currently collected meters per
|
||||
resource, in an ascending order based on the name of the meter.
|
||||
|
||||
Samples are collected for each meter that is present in the list of
|
||||
meters, except in case of instances that are not running or deleted from
|
||||
the OpenStack Compute database. If an instance is no more existing and
|
||||
there is ``time_to_live`` value is set in the :file:`ceilometer.conf`
|
||||
configuration file, then a group of samples are deleted in each
|
||||
expiration cycle. When the last sample is deleted for a meter, the
|
||||
database can be cleaned up by running ceilometer-expirer and the meter
|
||||
will not be present in the list above anymore. For more information
|
||||
about the expiration procedure see :ref:`telemetry-storing-samples`.
|
||||
|
||||
The Telemetry API supports simple query on the meter endpoint. The query
|
||||
functionality has the following syntax::
|
||||
|
||||
--query <field1><operator1><value1>;...;<field_n><operator_n><value_n>
|
||||
|
||||
The following command needs to be invoked to request the meters of one
|
||||
VM instance::
|
||||
|
||||
$ ceilometer meter-list --query resource=bb52e52b-1e42-4751-b3ac-45c52d83ba07
|
||||
+-------------------------+------------+-----------+--------------------------------------+----------------------------------+----------------------------------+
|
||||
| Name | Type | Unit | Resource ID | User ID | Project ID |
|
||||
+-------------------------+------------+-----------+--------------------------------------+----------------------------------+----------------------------------+
|
||||
| cpu | cumulative | ns | bb52e52b-1e42-4751-b3ac-45c52d83ba07 | b6e62aad26174382bc3781c12fe413c8 | cbfa8e3dfab64a27a87c8e24ecd5c60f |
|
||||
| cpu_util | gauge | % | bb52e52b-1e42-4751-b3ac-45c52d83ba07 | b6e62aad26174382bc3781c12fe413c8 | cbfa8e3dfab64a27a87c8e24ecd5c60f |
|
||||
| disk.ephemeral.size | gauge | GB | bb52e52b-1e42-4751-b3ac-45c52d83ba07 | b6e62aad26174382bc3781c12fe413c8 | cbfa8e3dfab64a27a87c8e24ecd5c60f |
|
||||
| disk.read.bytes | cumulative | B | bb52e52b-1e42-4751-b3ac-45c52d83ba07 | b6e62aad26174382bc3781c12fe413c8 | cbfa8e3dfab64a27a87c8e24ecd5c60f |
|
||||
| disk.read.bytes.rate | gauge | B/s | bb52e52b-1e42-4751-b3ac-45c52d83ba07 | b6e62aad26174382bc3781c12fe413c8 | cbfa8e3dfab64a27a87c8e24ecd5c60f |
|
||||
| disk.read.requests | cumulative | request | bb52e52b-1e42-4751-b3ac-45c52d83ba07 | b6e62aad26174382bc3781c12fe413c8 | cbfa8e3dfab64a27a87c8e24ecd5c60f |
|
||||
| disk.read.requests.rate | gauge | request/s | bb52e52b-1e42-4751-b3ac-45c52d83ba07 | b6e62aad26174382bc3781c12fe413c8 | cbfa8e3dfab64a27a87c8e24ecd5c60f |
|
||||
| disk.root.size | gauge | GB | bb52e52b-1e42-4751-b3ac-45c52d83ba07 | b6e62aad26174382bc3781c12fe413c8 | cbfa8e3dfab64a27a87c8e24ecd5c60f |
|
||||
| disk.write.bytes | cumulative | B | bb52e52b-1e42-4751-b3ac-45c52d83ba07 | b6e62aad26174382bc3781c12fe413c8 | cbfa8e3dfab64a27a87c8e24ecd5c60f |
|
||||
| disk.write.bytes.rate | gauge | B/s | bb52e52b-1e42-4751-b3ac-45c52d83ba07 | b6e62aad26174382bc3781c12fe413c8 | cbfa8e3dfab64a27a87c8e24ecd5c60f |
|
||||
| disk.write.requests | cumulative | request | bb52e52b-1e42-4751-b3ac-45c52d83ba07 | b6e62aad26174382bc3781c12fe413c8 | cbfa8e3dfab64a27a87c8e24ecd5c60f |
|
||||
| disk.write.requests.rate| gauge | request/s | bb52e52b-1e42-4751-b3ac-45c52d83ba07 | b6e62aad26174382bc3781c12fe413c8 | cbfa8e3dfab64a27a87c8e24ecd5c60f |
|
||||
| instance | gauge | instance | bb52e52b-1e42-4751-b3ac-45c52d83ba07 | b6e62aad26174382bc3781c12fe413c8 | cbfa8e3dfab64a27a87c8e24ecd5c60f |
|
||||
| instance:m1.tiny | gauge | instance | bb52e52b-1e42-4751-b3ac-45c52d83ba07 | b6e62aad26174382bc3781c12fe413c8 | cbfa8e3dfab64a27a87c8e24ecd5c60f |
|
||||
| memory | gauge | MB | bb52e52b-1e42-4751-b3ac-45c52d83ba07 | b6e62aad26174382bc3781c12fe413c8 | cbfa8e3dfab64a27a87c8e24ecd5c60f |
|
||||
| vcpus | gauge | vcpu | bb52e52b-1e42-4751-b3ac-45c52d83ba07 | b6e62aad26174382bc3781c12fe413c8 | cbfa8e3dfab64a27a87c8e24ecd5c60f |
|
||||
+-------------------------+------------+-----------+--------------------------------------+----------------------------------+----------------------------------+
|
||||
|
||||
As it was described above, the whole set of samples can be retrieved
|
||||
that are stored for a meter or filtering the result set by using one of
|
||||
the available query types. The request for all the samples of the
|
||||
``cpu`` meter without any additional filtering looks like the following::
|
||||
|
||||
$ ceilometer sample-list --meter cpu
|
||||
+--------------------------------------+-------+------------+------------+------+---------------------+
|
||||
| Resource ID | Meter | Type | Volume | Unit | Timestamp |
|
||||
+--------------------------------------+-------+------------+------------+------+---------------------+
|
||||
| c8d2e153-a48f-4cec-9e93-86e7ac6d4b0b | cpu | cumulative | 5.4863e+11 | ns | 2014-08-31T11:17:03 |
|
||||
| bb52e52b-1e42-4751-b3ac-45c52d83ba07 | cpu | cumulative | 5.7848e+11 | ns | 2014-08-31T11:17:03 |
|
||||
| c8d2e153-a48f-4cec-9e93-86e7ac6d4b0b | cpu | cumulative | 5.4811e+11 | ns | 2014-08-31T11:07:05 |
|
||||
| bb52e52b-1e42-4751-b3ac-45c52d83ba07 | cpu | cumulative | 5.7797e+11 | ns | 2014-08-31T11:07:05 |
|
||||
| c8d2e153-a48f-4cec-9e93-86e7ac6d4b0b | cpu | cumulative | 5.3589e+11 | ns | 2014-08-31T10:27:19 |
|
||||
| bb52e52b-1e42-4751-b3ac-45c52d83ba07 | cpu | cumulative | 5.6397e+11 | ns | 2014-08-31T10:27:19 |
|
||||
| ... |
|
||||
+--------------------------------------+-------+------------+------------+------+---------------------+
|
||||
|
||||
The result set of the request contains the samples for both instances
|
||||
ordered by the timestamp field in the default descending order.
|
||||
|
||||
The simple query makes it possible to retrieve only a subset of the
|
||||
collected samples. The following command can be executed to request the
|
||||
``cpu`` samples of only one of the VM instances::
|
||||
|
||||
$ ceilometer sample-list --meter cpu --query resource=bb52e52b-1e42-4751-
|
||||
b3ac-45c52d83ba07
|
||||
+--------------------------------------+------+------------+------------+------+---------------------+
|
||||
| Resource ID | Name | Type | Volume | Unit | Timestamp |
|
||||
+--------------------------------------+------+------------+------------+------+---------------------+
|
||||
| bb52e52b-1e42-4751-b3ac-45c52d83ba07 | cpu | cumulative | 5.7906e+11 | ns | 2014-08-31T11:27:08 |
|
||||
| bb52e52b-1e42-4751-b3ac-45c52d83ba07 | cpu | cumulative | 5.7848e+11 | ns | 2014-08-31T11:17:03 |
|
||||
| bb52e52b-1e42-4751-b3ac-45c52d83ba07 | cpu | cumulative | 5.7797e+11 | ns | 2014-08-31T11:07:05 |
|
||||
| bb52e52b-1e42-4751-b3ac-45c52d83ba07 | cpu | cumulative | 5.6397e+11 | ns | 2014-08-31T10:27:19 |
|
||||
| bb52e52b-1e42-4751-b3ac-45c52d83ba07 | cpu | cumulative | 5.6207e+11 | ns | 2014-08-31T10:17:03 |
|
||||
| bb52e52b-1e42-4751-b3ac-45c52d83ba07 | cpu | cumulative | 5.3831e+11 | ns | 2014-08-31T08:41:57 |
|
||||
| ... |
|
||||
+--------------------------------------+------+------------+------------+------+---------------------+
|
||||
|
||||
As it can be seen on the output above, the result set contains samples
|
||||
for only one instance of the two.
|
||||
|
||||
The ``ceilometer query-samples`` command is used to execute rich
|
||||
queries. This command accepts the following parameters:
|
||||
|
||||
``--filter``
|
||||
Contains the filter expression for the query in the form of:
|
||||
``{complex_op: [{simple_op: {field_name: value}}]}``.
|
||||
|
||||
``--orderby``
|
||||
Contains the list of ``orderby`` expressions in the form of:
|
||||
``[{field_name: direction}, {field_name: direction}]``.
|
||||
|
||||
``--limit``
|
||||
Specifies the maximum number of samples to return.
|
||||
|
||||
For more information about complex queries see
|
||||
:ref:`Complex query <complex-query>`.
|
||||
|
||||
As the complex query functionality provides the possibility of using
|
||||
complex operators, it is possible to retrieve a subset of samples for a
|
||||
given VM instance. To request for the first six samples for the ``cpu``
|
||||
and ``disk.read.bytes`` meters, the following command should be invoked::
|
||||
|
||||
$ ceilometer query-samples --filter '{"and": \
|
||||
[{"=":{"resource":"bb52e52b-1e42-4751-b3ac-45c52d83ba07"}},{"or":[{"=":{"counter_name":"cpu"}}, \
|
||||
{"=":{"counter_name":"disk.read.bytes"}}]}]}' --orderby '[{"timestamp":"asc"}]' --limit 6
|
||||
+--------------------------------------+-----------------+------------+------------+------+---------------------+
|
||||
| Resource ID | Meter | Type | Volume | Unit | Timestamp |
|
||||
+--------------------------------------+-----------------+------------+------------+------+---------------------+
|
||||
| bb52e52b-1e42-4751-b3ac-45c52d83ba07 | disk.read.bytes | cumulative | 385334.0 | B | 2014-08-30T13:00:46 |
|
||||
| bb52e52b-1e42-4751-b3ac-45c52d83ba07 | cpu | cumulative | 1.2132e+11 | ns | 2014-08-30T13:00:47 |
|
||||
| bb52e52b-1e42-4751-b3ac-45c52d83ba07 | cpu | cumulative | 1.4295e+11 | ns | 2014-08-30T13:10:51 |
|
||||
| bb52e52b-1e42-4751-b3ac-45c52d83ba07 | disk.read.bytes | cumulative | 601438.0 | B | 2014-08-30T13:10:51 |
|
||||
| bb52e52b-1e42-4751-b3ac-45c52d83ba07 | disk.read.bytes | cumulative | 601438.0 | B | 2014-08-30T13:20:33 |
|
||||
| bb52e52b-1e42-4751-b3ac-45c52d83ba07 | cpu | cumulative | 1.4795e+11 | ns | 2014-08-30T13:20:34 |
|
||||
+--------------------------------------+-----------------+------------+------------+------+---------------------+
|
||||
|
||||
Telemetry python bindings
|
||||
-------------------------
|
||||
The command line client library provides python bindings in order to use
|
||||
the Telemetry Python API directly from python programs.
|
||||
|
||||
The first step in setting up the client is to create a client instance
|
||||
with the proper credentials::
|
||||
|
||||
>>> import ceilometerclient.client
|
||||
>>> cclient = ceilometerclient.client.get_client(VERSION, username=USERNAME, password=PASSWORD, tenant_name=PROJECT_NAME, auth_url=AUTH_URL)
|
||||
|
||||
The ``VERSION`` parameter can be ``1`` or ``2``, specifying the API
|
||||
version to be used.
|
||||
|
||||
The method calls look like the following::
|
||||
|
||||
>>> cclient.meters.list()
|
||||
[<Meter ...>, ...]
|
||||
|
||||
>>> cclient.samples.list()
|
||||
[<Sample ...>, ...]
|
||||
|
||||
For further details about the python-ceilometerclient package, see the
|
||||
`Python bindings to the OpenStack Ceilometer
|
||||
API <http://docs.openstack.org/developer/python-ceilometerclient/>`__
|
||||
reference.
|
||||
|
||||
.. _telemetry-publishers:
|
||||
|
||||
Publishers
|
||||
~~~~~~~~~~
|
||||
The Telemetry module provides several transport methods to forward the
|
||||
data collected to the ceilometer-collector service or to an external
|
||||
system. The consumers of this data are widely different, like monitoring
|
||||
systems, for which data loss is acceptable and billing systems, which
|
||||
require reliable data transportation. Telemetry provides methods to
|
||||
fulfill the requirements of both kind of systems, as it is described
|
||||
below.
|
||||
|
||||
The publisher component makes it possible to persist the data into
|
||||
storage through the message bus or to send it to one or more external
|
||||
consumers. One chain can contain multiple publishers.
|
||||
|
||||
To solve the above mentioned problem, the notion of multi-publisher can
|
||||
be configured for each datapoint within the Telemetry module, allowing
|
||||
the same technical meter or event to be published multiple times to
|
||||
multiple destinations, each potentially using a different transport.
|
||||
|
||||
Publishers can be specified in the ``publishers`` section for each
|
||||
pipeline (for further details about pipelines see
|
||||
:ref:`data-collection-and-processing`) that is defined in
|
||||
the `pipeline.yaml
|
||||
<https://git.openstack.org/cgit/openstack/ceilometer/plain/etc/ceilometer/pipeline.yaml>`__
|
||||
file.
|
||||
|
||||
The following publisher types are supported:
|
||||
|
||||
notifier
|
||||
It can be specified in the form of
|
||||
``notifier://?option1=value1&option2=value2``. It emits data over
|
||||
AMQP using oslo.messaging. This is the recommended method of
|
||||
publishing.
|
||||
|
||||
rpc
|
||||
It can be specified in the form of
|
||||
``rpc://?option1=value1&option2=value2``. It emits metering data
|
||||
over lossy AMQP. This method is synchronous and may experience
|
||||
performance issues.
|
||||
|
||||
udp
|
||||
It can be specified in the form of ``udp://<host>:<port>/``. It emits
|
||||
metering data for over UDP.
|
||||
|
||||
file
|
||||
It can be specified in the form of
|
||||
``file://path?option1=value1&option2=value2``. This publisher
|
||||
records metering data into a file.
|
||||
|
||||
.. note::
|
||||
|
||||
If a file name and location is not specified, this publisher
|
||||
does not log any meters, instead it logs a warning message in
|
||||
the configured log file for Telemetry.
|
||||
|
||||
kafka
|
||||
It can be specified in the form of:
|
||||
``kafka://kafka_broker_ip: kafka_broker_port?topic=kafka_topic
|
||||
&option1=value1``.
|
||||
|
||||
This publisher sends metering data to a kafka broker.
|
||||
|
||||
.. note::
|
||||
|
||||
If the topic parameter is missing, this publisher brings out
|
||||
metering data under a topic name, ``ceilometer``. When the port
|
||||
number is not specified, this publisher uses 9092 as the
|
||||
broker's port.
|
||||
|
||||
The following options are available for ``rpc`` and ``notifier``. The
|
||||
policy option can be used by ``kafka`` publisher:
|
||||
|
||||
``per_meter_topic``
|
||||
The value of it is 1. It is used for publishing the samples on
|
||||
additional ``metering_topic.sample_name`` topic queue besides the
|
||||
default ``metering_topic`` queue.
|
||||
|
||||
``policy``
|
||||
It is used for configuring the behavior for the case, when the
|
||||
publisher fails to send the samples, where the possible predefined
|
||||
values are the following:
|
||||
|
||||
default
|
||||
Used for waiting and blocking until the samples have been sent.
|
||||
|
||||
drop
|
||||
Used for dropping the samples which are failed to be sent.
|
||||
|
||||
queue
|
||||
Used for creating an in-memory queue and retrying to send the
|
||||
samples on the queue on the next samples publishing period (the
|
||||
queue length can be configured with ``max_queue_length``, where
|
||||
1024 is the default value).
|
||||
|
||||
The following options are available for the ``file`` publisher:
|
||||
|
||||
``max_bytes``
|
||||
When this option is greater than zero, it will cause a rollover.
|
||||
When the size is about to be exceeded, the file is closed and a new
|
||||
file is silently opened for output. If its value is zero, rollover
|
||||
never occurs.
|
||||
|
||||
``backup_count``
|
||||
If this value is non-zero, an extension will be appended to the
|
||||
filename of the old log, as '.1', '.2', and so forth until the
|
||||
specified value is reached. The file that is written and contains
|
||||
the newest data is always the one that is specified without any
|
||||
extensions.
|
||||
|
||||
The default publisher is ``notifier``, without any additional options
|
||||
specified. A sample ``publishers`` section in the
|
||||
:file:`/etc/ceilometer/pipeline.yaml` looks like the following::
|
||||
|
||||
publishers:
|
||||
- udp://10.0.0.2:1234
|
||||
- rpc://?per_meter_topic=1
|
||||
- notifier://?policy=drop&max_queue_length=512
|
153
doc/admin-guide-cloud-rst/source/telemetry-events.rst
Normal file
153
doc/admin-guide-cloud-rst/source/telemetry-events.rst
Normal file
@ -0,0 +1,153 @@
|
||||
======
|
||||
Events
|
||||
======
|
||||
|
||||
In addition to meters, the Telemetry module collects events triggered
|
||||
within an OpenStack environment. This section provides a brief summary
|
||||
of the events format in the Telemetry module.
|
||||
|
||||
While a sample represents a single, numeric datapoint within a
|
||||
time-series, an event is a broader concept that represents the state of
|
||||
a resource at a point in time. The state may be described using various
|
||||
data types including non-numeric data such as an instance's flavor. In
|
||||
general, events represent any action made in the OpenStack system.
|
||||
|
||||
Event configuration
|
||||
~~~~~~~~~~~~~~~~~~~
|
||||
To enable the creation and storage of events in the Telemetry module
|
||||
``store_events`` option needs to be set to ``True``. For further configuration
|
||||
options, see the event section in the `OpenStack Configuration Reference
|
||||
<http://docs.openstack.org/kilo/config-reference/content/ch_configuring-openstack-telemetry.html>`__.
|
||||
|
||||
.. note::
|
||||
|
||||
It is advisable to set ``disable_non_metric_meters`` to ``True``
|
||||
when enabling events in the Telemetry module. The Telemetry module
|
||||
historically represented events as metering data, which may create
|
||||
duplication of data if both events and non-metric meters are
|
||||
enabled.
|
||||
|
||||
Event structure
|
||||
~~~~~~~~~~~~~~~
|
||||
Events captured by the Telemetry module are represented by five key
|
||||
attributes:
|
||||
|
||||
event\_type
|
||||
A dotted string defining what event occurred such as
|
||||
``"compute.instance.resize.start"``.
|
||||
|
||||
message\_id
|
||||
A UUID for the event.
|
||||
|
||||
generated
|
||||
A timestamp of when the event occurred in the system.
|
||||
|
||||
traits
|
||||
A flat mapping of key-value pairs which describe the event. The
|
||||
event's traits contain most of the details of the event. Traits are
|
||||
typed, and can be strings, integers, floats, or datetimes.
|
||||
|
||||
raw
|
||||
Mainly for auditing purpose, the full event message can be stored
|
||||
(unindexed) for future evaluation.
|
||||
|
||||
Event indexing
|
||||
~~~~~~~~~~~~~~
|
||||
The general philosophy of notifications in OpenStack is to emit any and
|
||||
all data someone might need, and let the consumer filter out what they
|
||||
are not interested in. In order to make processing simpler and more
|
||||
efficient, the notifications are stored and processed within Ceilometer
|
||||
as events. The notification payload, which can be an arbitrarily complex
|
||||
JSON data structure, is converted to a flat set of key-value pairs. This
|
||||
conversion is specified by a config file.
|
||||
|
||||
.. note::
|
||||
|
||||
The event format is meant for efficient processing and querying.
|
||||
Storage of complete notifications for auditing purposes can be
|
||||
enabled by configuring ``store_raw`` option.
|
||||
|
||||
Event conversion
|
||||
----------------
|
||||
The conversion from notifications to events is driven by a configuration
|
||||
file defined by the ``definitions_cfg_file`` in the :file:`ceilometer.conf`
|
||||
configuration file.
|
||||
|
||||
This includes descriptions of how to map fields in the notification body
|
||||
to Traits, and optional plug-ins for doing any programmatic translations
|
||||
(splitting a string, forcing case).
|
||||
|
||||
The mapping of notifications to events is defined per event\_type, which
|
||||
can be wildcarded. Traits are added to events if the corresponding
|
||||
fields in the notification exist and are non-null.
|
||||
|
||||
.. note::
|
||||
|
||||
The default definition file included with the Telemetry module
|
||||
contains a list of known notifications and useful traits. The
|
||||
mappings provided can be modified to include more or less data
|
||||
according to user requirements.
|
||||
|
||||
If the definitions file is not present, a warning will be logged, but an
|
||||
empty set of definitions will be assumed. By default, any notifications
|
||||
that do not have a corresponding event definition in the definitions
|
||||
file will be converted to events with a set of minimal traits. This can
|
||||
be changed by setting the option ``drop_unmatched_notifications`` in the
|
||||
:file:`ceilometer.conf` file. If this is set to True, any unmapped
|
||||
notifications will be dropped.
|
||||
|
||||
The basic set of traits (all are TEXT type) that will be added to all
|
||||
events if the notification has the relevant data are: service
|
||||
(notification's publisher), tenant\_id, and request\_id. These do not
|
||||
have to be specified in the event definition, they are automatically
|
||||
added, but their definitions can be overridden for a given event\_type.
|
||||
|
||||
Event definitions format
|
||||
------------------------
|
||||
The event definitions file is in YAML format. It consists of a list of
|
||||
event definitions, which are mappings. Order is significant, the list of
|
||||
definitions is scanned in reverse order to find a definition which
|
||||
matches the notification's event\_type. That definition will be used to
|
||||
generate the event. The reverse ordering is done because it is common to
|
||||
want to have a more general wildcarded definition (such as
|
||||
``compute.instance.*``) with a set of traits common to all of those
|
||||
events, with a few more specific event definitions afterwards that have
|
||||
all of the above traits, plus a few more.
|
||||
|
||||
Each event definition is a mapping with two keys:
|
||||
|
||||
event\_type
|
||||
This is a list (or a string, which will be taken as a 1 element
|
||||
list) of event\_types this definition will handle. These can be
|
||||
wildcarded with unix shell glob syntax. An exclusion listing
|
||||
(starting with a ``!``) will exclude any types listed from matching.
|
||||
If only exclusions are listed, the definition will match anything
|
||||
not matching the exclusions.
|
||||
|
||||
traits
|
||||
This is a mapping, the keys are the trait names, and the values are
|
||||
trait definitions.
|
||||
|
||||
Each trait definition is a mapping with the following keys:
|
||||
|
||||
fields
|
||||
A path specification for the field(s) in the notification you wish
|
||||
to extract for this trait. Specifications can be written to match
|
||||
multiple possible fields. By default the value will be the first
|
||||
such field. The paths can be specified with a dot syntax
|
||||
(``payload.host``). Square bracket syntax (``payload[host]``) is
|
||||
also supported. In either case, if the key for the field you are
|
||||
looking for contains special characters, like ``.``, it will need to
|
||||
be quoted (with double or single quotes):
|
||||
``payload.image_meta.’org.openstack__1__architecture’``. The syntax
|
||||
used for the field specification is a variant of
|
||||
`JSONPath <https://github.com/kennknowles/python-jsonpath-rw>`__
|
||||
|
||||
type
|
||||
(Optional) The data type for this trait. Valid options are:
|
||||
``text``, ``int``, ``float``, and ``datetime``. Defaults to ``text``
|
||||
if not specified.
|
||||
|
||||
plugin
|
||||
(Optional) Used to execute simple programmatic conversions on the
|
||||
value in a notification field.
|
1302
doc/admin-guide-cloud-rst/source/telemetry-measurements.rst
Normal file
1302
doc/admin-guide-cloud-rst/source/telemetry-measurements.rst
Normal file
File diff suppressed because it is too large
Load Diff
@ -1,5 +1,8 @@
|
||||
.. _telemetry-system-architecture:
|
||||
|
||||
===================
|
||||
System architecture
|
||||
~~~~~~~~~~~~~~~~~~~
|
||||
===================
|
||||
|
||||
The Telemetry module uses an agent-based architecture. Several modules
|
||||
combine their responsibilities to collect data, store samples in a
|
||||
@ -61,8 +64,10 @@ communication.
|
||||
|
||||
|
|
||||
|
||||
.. _telemetry-supported-databases:
|
||||
|
||||
Supported databases
|
||||
-------------------
|
||||
~~~~~~~~~~~~~~~~~~~
|
||||
|
||||
The other key external component of Telemetry is the database, where
|
||||
events, samples, alarm definitions and alarms are stored.
|
||||
@ -88,8 +93,10 @@ The list of supported database back ends:
|
||||
|
||||
|
|
||||
|
||||
.. _telemetry-supported-hypervisors:
|
||||
|
||||
Supported hypervisors
|
||||
---------------------
|
||||
~~~~~~~~~~~~~~~~~~~~~
|
||||
|
||||
The Telemetry module collects information about the virtual machines,
|
||||
which requires close connection to the hypervisor that runs on the
|
||||
@ -125,7 +132,7 @@ The list of supported hypervisors is:
|
||||
|
|
||||
|
||||
Supported networking services
|
||||
-----------------------------
|
||||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||
|
||||
Telemetry is able to retrieve information from OpenStack Networking and
|
||||
external networking services:
|
||||
@ -148,8 +155,10 @@ external networking services:
|
||||
|
||||
|
|
||||
|
||||
.. _telemetry-users-roles-tenants:
|
||||
|
||||
Users, roles and tenants
|
||||
------------------------
|
||||
~~~~~~~~~~~~~~~~~~~~~~~~
|
||||
|
||||
This module of OpenStack uses OpenStack Identity for authenticating and
|
||||
authorizing users. The required configuration options are listed in the
|
||||
@ -157,10 +166,9 @@ authorizing users. The required configuration options are listed in the
|
||||
section <http://docs.openstack.org/kilo/config-reference/content/ch_configuring-openstack-telemetry.html>`__
|
||||
in the *OpenStack Configuration Reference*.
|
||||
|
||||
Two roles are used in the system basically, which are the 'admin' and
|
||||
'non-admin'. The authorization happens before processing each API
|
||||
request. The amount of returned data depends on the role the requestor
|
||||
owns.
|
||||
The system uses two roles:`admin` and `non-admin`. The authorization happens
|
||||
before processing each API request. The amount of returned data depends on the
|
||||
role the requestor owns.
|
||||
|
||||
The creation of alarm definitions also highly depends on the role of the
|
||||
user, who initiated the action. Further details about alarm handling can
|
||||
|
@ -4,9 +4,6 @@
|
||||
Telemetry
|
||||
=========
|
||||
|
||||
Introduction
|
||||
~~~~~~~~~~~~
|
||||
|
||||
Even in the cloud industry, providers must use a multi-step process
|
||||
for billing. The required steps to bill for usage in a cloud
|
||||
environment are metering, rating, and billing. Because the provider's
|
||||
@ -46,22 +43,17 @@ You can retrieve the collected samples in three different ways: with
|
||||
the REST API, with the command line interface, or with the Metering
|
||||
tab on an OpenStack dashboard.
|
||||
|
||||
.. include:: telemetry-system-architecture.rst
|
||||
.. include:: telemetry-troubleshooting-guide.rst
|
||||
.. include:: telemetry-best-practices.rst
|
||||
|
||||
|
||||
.. toctree::
|
||||
:hidden:
|
||||
:maxdepth: 2
|
||||
|
||||
telemetry-system-architecture.rst
|
||||
telemetry-data-collection.rst
|
||||
telemetry-data-retrieval.rst
|
||||
telemetry-measurements.rst
|
||||
telemetry-events.rst
|
||||
telemetry-troubleshooting-guide.rst
|
||||
telemetry-best-practices.rst
|
||||
|
||||
|
||||
.. TODO (OL) Translate and add the below files with new name
|
||||
include: telemetry/section_telemetry-data-collection.xml
|
||||
include: telemetry/section_telemetry-data-retrieval.xml
|
||||
include: telemetry/section_telemetry-alarms.xml
|
||||
include: telemetry/section_telemetry-measurements.xml
|
||||
include: telemetry/section_telemetry-events.xml
|
||||
|
Loading…
Reference in New Issue
Block a user