[config-ref] Fix minor issues with IBM FlashSystem
Fixes some minor formatting issues with the IBM FlashSystem volume driver RST conversion. Change-Id: Ie99b48ff8b20fa6e53c4c65d1c9602f0e7e12469 Implements: blueprint config-ref-rst
This commit is contained in:
parent
938325d847
commit
9b5502664b
@ -47,12 +47,12 @@ Data Path configuration
|
||||
|
||||
Using Fiber Channel (FC), each FlashSystem node should have at least one
|
||||
WWPN port configured. If the ``flashsystem_multipath_enabled`` flag is
|
||||
set to ``True`` in the Cinder configuration file, the driver uses all
|
||||
available WWPNs to attach the volume to the instance. If the flag is not set,
|
||||
the driver uses the WWPN associated with the volume's preferred node (if
|
||||
available). Otherwise, it uses the first available WWPN of the system.
|
||||
The driver obtains the WWPNs directly from the storage system. You do
|
||||
not need to provide these WWPNs to the driver.
|
||||
set to ``True`` in the Block Storage service configuration file, the driver
|
||||
uses all available WWPNs to attach the volume to the instance. If the flag is
|
||||
not set, the driver uses the WWPN associated with the volume's preferred node
|
||||
(if available). Otherwise, it uses the first available WWPN of the system. The
|
||||
driver obtains the WWPNs directly from the storage system. You do not need to
|
||||
provide these WWPNs to the driver.
|
||||
|
||||
.. note::
|
||||
|
||||
@ -108,7 +108,7 @@ To enable the IBM FlashSystem FC driver, configure the following options in the
|
||||
- Enable multipath for FC connections
|
||||
* - ``flashsystem_multihost_enabled``
|
||||
- Optional
|
||||
- True
|
||||
- ``True``
|
||||
- Enable mapping vdisks to multiple hosts [1]_
|
||||
|
||||
.. [1]
|
||||
@ -181,7 +181,7 @@ in the ``cinder.conf`` configuration file:
|
||||
- Connection protocol should be set to ``iSCSI``
|
||||
* - ``flashsystem_multihost_enabled``
|
||||
- Optional
|
||||
- True
|
||||
- ``True``
|
||||
- Enable mapping vdisks to multiple hosts [2]_
|
||||
* - ``iscsi_ip_address``
|
||||
- Required
|
||||
@ -190,7 +190,7 @@ in the ``cinder.conf`` configuration file:
|
||||
* - ``flashsystem_iscsi_portid``
|
||||
- Required
|
||||
-
|
||||
- Set to the id of the iscsi_ip_address obtained by FlashSystem GUI or CLI [4]_
|
||||
- Set to the id of the ``iscsi_ip_address`` obtained by FlashSystem GUI or CLI [4]_
|
||||
|
||||
.. [2]
|
||||
This option allows the driver to map a vdisk to more than one host at
|
||||
@ -201,7 +201,7 @@ in the ``cinder.conf`` configuration file:
|
||||
``False`` will provide added safety.
|
||||
|
||||
.. [3]
|
||||
On the cluster of the FlashSystem, the iSCSI IP address column is the
|
||||
On the cluster of the FlashSystem, the ``iscsi_ip_address`` column is the
|
||||
seventh column ``IP_address`` of the output of ``lsportip``.
|
||||
|
||||
.. [4]
|
||||
@ -209,8 +209,8 @@ in the ``cinder.conf`` configuration file:
|
||||
column ``id`` of the output of ``lsportip``,
|
||||
not the sixth column ``port_id``.
|
||||
|
||||
Limitation and known issues
|
||||
~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||
Limitations and known issues
|
||||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||
|
||||
IBM FlashSystem only works when:
|
||||
|
||||
|
Loading…
Reference in New Issue
Block a user